Home

Faronics Power Save User Guide

image

Contents

1. Faronics Power Save User Guide Definition of Terms Term Definition Local Wakeup Computers in Standby or Hibernate mode can be locally woken up by the Local Wakeup feature without using Wake on LAN technology or without a network connection MSI Microsoft An msi file is an Windows standard installation package One is used to Installer install the Power Save workstation file Power Schedule A Power Schedule can consist of one or more Power Save Configurations This also includes a schedule to apply the configuration on one or more computers Power A Power Configuration consists of a e Inactivity Timeout Actions defines whether Power Save must turn off monitors hard disks and shut down the computer after a predefined interval e Inactivity Definitions defines whether Power Save must manage power on the computer when the hard disk CPU or network activities are below the specified levels Power Save A software library that extends the basic functionality of Faronics Core with Loadin Power Save specific commands and status Scheduling A process used to determine when a task will execute based on Windows Scheduling Defer Mode Ensures that Power Save does not manage power on the computer for the specified duration Task A Power Save action applied to one or more workstations such as applying new settings shutting down or waking up Power Save workstations Wake on LAN A hardware enab
2. This chapter explains the Power Save reports in detail Full Operation Report Audit Only Report Exporting Printing and Emailing Power Save Reports Faronics Power Save User Guide 52 Power Save Reports Generating Power Save Reports Power Save provides the following reports e Full Operation Report e Audit Only Report e System Activity Report Faronics Power Save User Guide Full Operation Report 53 Full Operation Report The Full Operation Report displays the Energy Consumption Profiles the savings for each profile and total savings This report includes the Detailed Power Save Performance Report that displays the savings for each computer on the network and the total savings To generate the Full Operation Report complete the following steps 1 Right click on a workstation and select Generate Report gt Full Operation Report 2 The Full Operation Report dialog is displayed 45 Full Operation Report Report Name 12010 02 11 Full Operation Report Type Savings by Energy Consumption Profiles gt From To e a Februay 2010 gt February PE A PES aes AE Su Mo TuWe Th Fr Su Mo TuWe Th Fr Sa 7 8 9 1011 12 13 7 8 9 1011 12 13 14 15 16 17 18 19 20 14 15 16 17 18 19 20 21 22 23 24 25 26 27 21 22 23 24 25 26 27 28 28 C Report on events between Start Time End Time Su Mo Tu We Th Fr Sa On these days CO Include Detailed Performance Report C Open in default
3. Loadin cee 17 Faronics Core User Interface Components saasaa aeaa a a 20 Installing or Upgrading Power Save on a Workstation via Core Console o 22 Installing Power Save Manually on a Workstation assau ee 23 Suppress Reboot ses staci bee a Rae pa RE a eee 25 Applying Power Save License via Core Console auaa aaa es 26 Accessing Power Save cece eee eee 27 OVERVIEW s tea ea ee Nae A RRA ad bao eA Sa Rh RS A ale hae de ee as 28 Accessing Power Save via Core Console 1 0 e a a 29 Core Console Actions Pane sie cocoa cai ee 29 Accessing Power Save on a Workstation aa saa aaa a 30 Configuring Power Save 00 0c eee eee ee 31 OVERVIEW diese ams aa aed Gla a eo awe al ha RO RE ee aa 32 Power Save Policy ssi ta 22 eek eee ae eae ee e ae PORE Se ee ae A ee 33 Add or Modify a Power Schedule 2 0 a 41 Power Save Alers c 20 du es wales GA tla whe DR ee ae a OSS a a Glee wea 45 Configuring Power Save Manually on a Workstation naasa saaa aa e 46 Configuring a Power Schedule ee 49 Advanced Options sy vivi sit Seve we eet dee Malas Rew Re Be Rw Me he he ee 50 Dynamic Custom Workstation GroupS aaa aaa a 50 Wake on LAN Across SubnetS saasaa aaa ee 50 Wake on LAN Web Interface 2 2 ee 50 Faronics Power Save User Guide 4 Contents Power Save Reports 000 ce eee 51 Generating Power Save ReportS aaua saaa aaa a es 52 Full Operation Report sesa sa
4. The following events are associated with the current policy Windows Power Options ae Mo lu Wih lr Ss S Nate Hardware Settings User Experience Administration Settings Energy Costs Work Day Policy Patch Policy Select an event to modify its properties Cox 3 Configure the following options in Add Power Event dialog Faronics Power Save User Guide 42 Configuring Power Save Faronics Power Save User Guide Start Time 08 00 AM v Mo Tu We Th Fr Sa Su Days Y MAwMeoa A E Wake up client for this event to take effect wake up from hibemate or standby mode only Shutdown Dynamic Configuration 9 Advanced Settings Begin Power Management on computer startup after first keyboard mouse activity Running on Batteries 2 Tum off monitor if Keybord Mouse are inactive for i Minutes E Tum off hard disk if Keybord Mouse are inactive for i Minutes T PC if Keyboard Mouse are inactive for i Minutes V Shutdown f sleep state is not supported Show Additional Inactivity Definitions Disk activity is less than gt Sample every second s 4 CPU activity is less than Sample every second s E Network activity is less than 25 Sample every 20 second s Gs Note edit the name of the event as required Start time select the start time from the drop down Days select the days when this event will occur Wake up client fo
5. basis If there is more than one Loadin installed the right click contextual menu for A Power Save can be accessed by right clicking a workstation selecting Power Save and then selecting the particular action Core Console Actions Pane Along with right click functionality several Power Save commands can be accessed via the Core Console Actions pane located on the right side of the Core Console window The Actions pane lists these tasks once a workstation has been selected from the list Faronics Power Save User Guide 30 Accessing Power Save Accessing Power Save on a Workstation Limited Power Save features can be accessed by right clicking the Power Save icon in the Windows System Tray Faronics Power Save User Guide Topics 31 Configuring Power Save Power Save can be used to manage various power settings on your network This chapter explains how to administer and configure Power Save Overview Power Save Policy Add or Modify a Power Schedule Advanced Options Faronics Power Save User Guide 32 Configuring Power Save Overview Power Event Power Schedule Power Policy Faronics Power Save User Guide Power Save consists of the following concepts A Power Save Configuration consists of Inactivity Timeout Actions defines whether Power Save must turn off monitors hard disks and shut down the computer after a predefined interval e Inactivity Definitions defines whether
6. is done by the Core Server Faronics Core Faronics Core consists of the Core Server Core Console Core Database and the Core Agent Inactivity The definition of what makes a workstation inactive keyboard and mouse Definitions inactivity and one of the following parameters e Disk Utilization user defined measurement of disk hard drive utilization if the disk utilization is lower than this defined level the workstation is considered inactive and power saving actions will occur e CPU utilization user defined measurement of CPU utilization if the CPU utilization is lower than this defined level the workstation is considered inactive and power saving actions will occur e Network activity user defined measurement of network activity if the network activity is lower than this defined level the workstation is considered inactive and power saving actions will occur e Applications running user defined list of applications if no application from a user defined list is running the workstation is considered inactive and power saving actions will occur Inactivity Actions that Power Save can perform when a workstation becomes inactive Timeout which are Actions Turn off monitor e Standby a mode in which the operating system is suspended and stored in memory before shut down e Hibernate a mode in which the operating system is suspended by storing memory on the hard disk before powering down e Shut down
7. select the Save As type as required and click Save To print a Power Save report click the Print icon at the top right corner of the Power Save Report Select the printer in the Print dialog and click Print To Email a Power Save report right click the report and select Email Report The default Email client is launched with the Power Save Report attached Send to Faronics The System Activity report can be sent to Faronics Technical Support via the Send to Faronics feature This feature allows you to send the events generated by Power Save Faronics Core and Windows to Faronics Technical Support In the Console Tree pane right click on the report and select Send to Faronics Specify values for the following fields and click Send e Name e Email Address Ticket Number e Phone Number e Comments Faronics Power Save User Guide 60 Power Save Reports Faronics Power Save User Guide Topics Command Line Control This chapter explains the command line options available to manage Power Save Command Line Control Command Line Errors Faronics Power Save User Guide 61 62 Command Line Control Command Line Control Power Save command line control offers network administrators increased flexibility in managing Power Save workstations by allowing for control of Power Save via third party management tools and or central management solutions The following commands are available Functio
8. web browser 3 Specify values for the following fields e Report Name specify a name for the report e Report Type select the report type from the drop down Savings by Energy Consumption Profiles Savings by Custom Workstation Groups Savings by Custom Power Policy Top 25 Energy Savers Bottom 25 Energy Savers e From select the date e To select the date Report on events between select the Start time and End time e On these days select the days Faronics Power Save User Guide 54 Power Save Reports e Include Detailed Performance Report select any of the following check boxes Include Workstation Name Include Workstation IP Address Include MAC Address e Open in default Web Browser select the check box to open the report in the default web browser 4 Click Generate The report name appears in the left pane under the Reports node and it is launched in the default web browser if Open in default Web Browser was selected Click on the name of the report and the details are displayed in the main screen of the console The value of the report is an estimate however the more accurate the values A entered in the Energy Consumption Profile the more accurate the report will be Faronics Power Save User Guide Audit Only Report 55 Audit Only Report The Audit Only Report displays the Potential Energy saved by the computer s on the network if it was m
9. you recently purchased an upgraded version of Power Save you can apply the license via Core Console after installing it on the workstation Complete the following steps to apply the Power Save license 1 Right click on Core Server Name in the Console Tree pane select Properties 2 Click the Power Save tab Click Edit and enter the License Key in the License Key field Click Apply Click OK 4 The License Key is applied to all the workstations running Power Save Faronics Power Save User Guide Topics Accessing Power Save Overview Accessing Power Save via Core Console Accessing Power Save on a Workstation Faronics Power Save User Guide 27 28 Accessing Power Save Overview Power Save can be accessed via Core Console on the Core Server or directly from the workstation where it is deployed Faronics Power Save User Guide Accessing Power Save via Core Console 29 Accessing Power Save via Core Console Power Save can be accessed through Core Console by selecting one or more workstation s from the Workstations list in Core Console and going to Power Save Loadin gt Policy_Name gt View Policy Details Multiple workstations can be selected at one time Hold down the Shift key to select a contiguous range of workstations or Ctrl to select any number of non contiguous workstations Changes made will be applied to all selected workstations Workstation status can only be retrieved on an individual
10. E Shutdown Send Message El Make Note m AX Remote Launch Faronics Core User Interface Components Core Console is the User Interface for the Core Server The following User Interface components are displayed on Core Console Console Tree Pane The Core Console node can have multiple Core Server nodes Under the Core Server node there are three main nodes These are Workstations Tasks and Reports Clicking on one of these nodes changes the information displayed in the Results pane Action Pane Actions in the Action pane are applied to selected workstations and are only shown when one or more workstation have been selected This Action pane is a duplication of the right click context menu Core Console Properties Dialog The Core Console Properties dialog is accessed by right clicking on the Core Console icon in the Console Tree pane and selecting Properties Faronics Power Save User Guide Installing Power Save Loadin 21 Core Server Properties Dialog The Core Server dialog is accessed by right clicking on the Core Server connection icon in the Console Tree pane and selecting Properties This dialog displays the Loadin specific tabs Console Tree Pane LDAP Groups The Console Tree pane has the following nodes e Core Console this is the root node e Core Server there can be multiple server nodes The management of workstations processing of tasks and communication betw
11. Far onIics AAA SHME AUTOMATED Energy Conservation User Guide Fofoncs Control www faronics com Last modified November 2012 1999 2012 Faronics Corporation All rights reserved Faronics Deep Freeze Faronics Core Console Faronics Anti Executable Faronics Anti Virus Faronics Data Igloo Faronics Device Filter Faronics Power Save Faronics Insight Faronics System Profiler and WINSelect are trademarks and or registered trademarks of Faronics Corporation All other company and product names are trademarks of their respective owners Faronics Power Save User Guide Contents Power Sav cias aa a a a a a Sm a aaa eee 5 Important Informationin ss cee ena a ea a a ek 6 ADOUE FaAnOMICS am iuei esd ew ea ad Snel a ae Pe dee eS 6 Product Documentation 0 cc es 6 Technical SUppot rsrs enivrer ina AAA a ee AA A A A 7 Contact Information 1 eiom iae Ee ea e e ea 7 Definition of TEMS a sce sha ca a Aa a a a a A Ee AA 8 Introduction ooo 11 Power Save OVervieW osos ead ea wiege a a a A 12 About Power Save 12 About Faronics Cores a crecen A 12 System Requirements ics 0608 sees eae eae aaa RS RES HA a ae 13 Power Save Requirements auauua aaa aa a 13 Faronics Core Requirements sesan stase E a e a a a a a E E a 13 Installing Power Save ssssasssssssssssnnsssnnnssnnnssnnnnnnnnn 15 Installation Overview 2 16 Installing Faronics Core swe kerk ee On ee Mae a he a 16 Installing Power Save
12. Power Save must manage power on the computer when the hard disk CPU or network activities are below the specified levels A Power Schedule consists of e One or more Power Events A Power Policy consists of e Power Schedule e Configuration Settings e Energy Cost Power Save Policy 33 Power Save Policy A Policy is a group of settings A Power Save Policy can be created and applied to multiple workstations Multiple Policies can be created as per the requirement Complete the following steps to create a Power Save Policy 1 Right click on the Power Save Loadin and select New Policy 2 The New Policy dialog is displayed Specify the name of the policy and click OK New Policy a Policy Name 3 Right click on the policy and select Policy Details The Power Schedule is displayed that is a Configuration and a schedule Complete the following settings Power Schedule The following events are associated with the current policy Select an event to modify its properties Remove e Click Add to add a new Power Event e Select a configuration and click Edit to edit a Power Event e Select a configuration and click Remove to remove a Power Event For more information on creating a Power Event see Add or Modify a Power Schedule Faronics Power Save User Guide 34 Configuring Power Save 4 Click Configuration Settings A Power Schedule orfiguration Sett
13. Save Select Ignore all activity contributed by the following checked applications Browse to select the Application Name and click Add Select an entry and click Remove to remove an application 6 Click Windows Power Options Policy Details Test ES Power Schedule E Configuration Settings Application Control Windows Power Options 1 Override Windows Power Options Windows Power Options Hardware Settings Prevent the Windows operating system Power Options from interfering with Faronics Power Save s power User Experience management Administration Settings Resume From Standby Password Challenge Energy Costs Require the user to enter their Windows password when the computer resumes from standby or hibemate Logoff Before Powering Down Computer Logoff the user before placing the computer in standby or hibemate state ok J _Caca Apply Select the following options Override Windows Power Options select this option if you want Power Save to override the Windows Power Options This option is selected by default If this option is selected the Windows Power Options are ignored and Power Save settings take precedence Resume from Standby Password Challenge select this option to require users to enter their Windows password when the computer resumes from standby or hibernate Logoff Before Powering Down Computer select this option to logoff the user before poweri
14. a cee ee eee ee ee ee a ee 53 Audit Only Report woe ko bk eae ee eR Ree OR ee ee Ra eRe Re a OE eR ea ee eS 55 system Activity Report o 004 6 Bhai ha ee ee ae I ee we Blew ee kee 57 Exporting Printing and Emailing Power Save Reports asas aaa a a ees 59 EXPOrinG as esa wedi a Caw eee ew ee Hae Bie Bw Eee Re ew Raw o ea Ses 59 Printing a 0k 4 ee a a ee ae ee ee We AAA 59 Email odiada ee Gok why tee ae diy ea A ds eg na ew ey ES BE r ees 59 Send to FarOnics 4 4 4 o 00 a A A A ee we ee de a ee 59 Command Line Control ar s sessin ee 61 Command Line Control secre sesira a a a Re a A a Pe ae ae eS 62 Example Command Line 2 222 44 06222 ba caca irarri ratna cineda a 62 Installing Using Command Line Parameters 000 cet es 62 Command Vine Enrors sgia eek ae di en a ee Paes a A aa Oa hare did 63 Uninstalling Power Save 000 cee ee 65 Uninstalling the Power Save Loadin via Add or Remove Programs 20000000 5 66 Uninstalling Power Save on a Workstation via Core Console o ooooooooo ooo 67 Uninstalling on a Workstation using the Uninstall Wizard o o ooooooooooo 68 Uninstalling Power Save on a Workstation Using Command Line o ooooooo 70 Faronics Power Save User Guide Topics Power Save Power Save uses intelligent energy management to ensure workstations are available when system resources are required but conserving power during productivity downtimes Important Inform
15. anaged by Power Save To generate the Audit Only Report complete the following steps 1 Right click on a workstation and select Generate Report gt Audit Only Report 2 The Audit Only Report dialog is displayed Audit Only Report Today Thursday February 11 2010 Report Name 2010 02 11 Audit Onl Report Type 14 15 16 17 18 19 20 14 15 16 17 18 19 20 21 22 23 24 25 26 27 21 22 23 24 25 26 27 28 28 6 13 C Report on events between Start Time M End Time Su Mo Tu We Th Fr Sa On these days Include Detailed Performance Report C Open in default web browser Generate Cancel 3 Specify values for the following fields e Report Name specify a name for the report e Report Type select the report type from the drop down Savings by Energy Consumption Profiles Savings by Custom Workstation Groups Savings by Custom Power Policy Top 25 Potential Energy Savers Bottom 25 Potential Energy Savers e From select the date e To select the date e Report on events between select the Start time and End time e On these days select the days Faronics Power Save User Guide 56 Power Save Reports e Include Detailed Performance Report select any of the following check boxes Include Workstation Name Include Workstation IP Address Include MAC Address e Open in default Web Browser select the check box to open the report in the default we
16. ation Technical Support Definition of Terms Faronics Power Save User Guide 6 Power Save Important Information This section contains important information about your Faronics Product About Faronics Faronics delivers market leading solutions that help manage simplify and secure complex IT environments Our products ensure 100 machine availability and have dramatically impacted the day to day lives of thousands of information technology professionals Fueled by a market centric focus Faronics technology innovations benefit educational institutions health care facilities libraries government organizations and corporations Product Documentation The following documents form the Faronics Power Save documentation set e Faronics Power Save User Guide This document guides you how to use the product Faronics Power Save Release Notes This document lists the new features and known issues and closed issues e Faronics Power Save readme txt This document guides you through the installation process e Faronics Power Save Dashboard Technical Paper The Faronics Power Save Dashboard works with Faronics Power Save to provide on demand web based reporting of energy saved and potential energy savings This document explains how to install configure and use the Faronics Power Save Dashboard Faronics Power Save User Guide Technical Support Technical Support Every effort has been made to design th
17. ation or a Full version e Validation displays when Power Save expires Faronics Power Save User Guide 47 48 Configuring Power Save Adjust Settings for Dynamic Configuration If Dynamic Configuration is selected in Power Event configuration the user can request the administrator to adjust the settings There are two options available by double clicking the Power Save icon in the System Tray e Increase my power savings e Give me more time before taking power savings actions Select one of the options and click Submit Faronics Power Save User Guide Configuring a Power Schedule Configuring a Power Schedule 49 Power Save consists of the following concepts Power Save Configuration A Power Save Configuration consists of Power Schedule A Power Schedule consists of e One or more Power Save Configurations Power Policy A Power Policy consists of e Power Schedule e Configuration Settings e Energy Cost Faronics Power Save User Guide 50 Configuring Power Save Advanced Options The following advanced options can be used with Power Save e Dynamic Custom Workstation Groups e Wake on LAN Across Subnets e Wake on LAN Web Interface Dynamic Custom Workstation Groups In a scenario where you have multiple managed workstations Faronics Core provides a feature to create Dynamic Custom Workstation Groups This feature allows you to create workstation groups and dynamically update t
18. b browser 4 Click Generate The report name appears in the left pane under the Reports node and it is launched in the default web browser if Open in default Web Browser was selected Click on the name of the report and the details are displayed in the main screen of the console The value of the report is an estimate however the more accurate the values A entered in the Energy Consumption Profile the more accurate the report will be Faronics Power Save User Guide System Activity Report 57 System Activity Report The System Activity Report displays the system activity for the computer if it is managed by Power Save This report also displays the activity by Windows and Faronics Core The System Activity Report can be generated for a single workstation at a time To generate the System Activity Report complete the following steps 1 Right click on a workstation and select Generate Report gt System Activity Report 2 The System Activity Report dialog is displayed 45 System Activity Report Today Monday August 09 2010 Report Name 2010 08 09 System Activity Report From To A A a A E ea Su Mo Tu We Th Fr Sa Su Mo Tu We Th Fr Sa 1 J 1 m2345 6 m2345 6 8 Bg 10 11 12 131 8 3 10 11 12 13 14 15 16 17 18 19 20 21 15 16 17 18 19 20 21 22 23 24 25 26 27 28 22 23 24 25 26 27 28 29 30 31 29 30 31 4 O Report on events between Start Time M End Time Su Mo Tu We Th Fr Sa On these days Includ
19. cify if Keyboard Mo hard disk after the eee if it is minutes or ere it is minutes or use are specified time seconds when seconds when the inactive for interval plugged in computer is running on batteries Shutdown Select the check x minutes Selectthenumeric x minutes Select the numeric box to value and specify value and specify if Standby Shutdown Standby Seconas if it is minutes or seconas it is eee a Hibernate PC Hibernate the seconds when seconds when the after computer after the plugged in computer is specified time running on interval batteries Shutdown if Select the check sleep state is box to shutdown not supported the computer if Standby or Hibernate actions are not supported Faronics Power Save User Guide 44 Configuring Power Save Description When plugged in Description When running on Description Sample every Select the check box to manage power when the disk activity is less than the specified value Disk activity is less than x percent Select the value in percent Batteries x percentage Select the value in percent Select the duration for sampling the activity to check if it is less than the selected value For example if the is set to 50 and sample every is set to 10 seconds the program will check for disk utilization every 10 seconds to determine if the utilization is below 50 Select the check box to manage power when the CPU act
20. din in Core Console The Wakeup will be cancelled when the workstation is in Audit mode even if it was scheduled This option is available only if the Allow users to schedule a local wakeup and View Auto Saved Files This options displays the files that were Auto Saved by Power Save Faronics Power Save User Guide Configuring Power Save Manually on a Workstation 1 Right click and select View Auto Saved files 2 The Automatically Saved Files dialog is displayed Faronics Power Save Automatically Saved Files Items in red indicate the Saved By User file is newer than the Saved By Power Save file Name Saved By User Saved By Power Save Size Location Viewd the Saved By User file and Saved By Power Save file Select a location to store the Saved By PowerSave File Delete the Saved By Power Save file and clear it From dialog 3 Select any of the following actions e Click Open to open the file e Click Save to save the file to another location Close e Click Discard to delete the file from the dialog and from the computer e Click Close to close the dialog About This option displays information about Power Save eS Faronics Power Save 45 POWER Product Faronics Power Save Version 4 10 3220 637 Evaluation Validation Valid Until February 06 2010 e Product name of the product e Version displays the version number and specifies if the product is an Evalu
21. e Workstation Name Include Workstation IP Address Include Workstation MAC Address C Open in default web browser Generate Cancel 3 Specify values for the following fields e Report Name specify a name for the report e From select the date e To select the date e Report on events between select the Start Time and End Time e On these days select the days e Include Detailed Performance Report select any of the following check boxes Include Workstation Name Include Workstation IP Address Include MAC Address e Open in default Web Browser select the check box to open the report in the default web browser Faronics Power Save User Guide 58 Power Save Reports 4 Click Generate The report name appears in the left pane under the Reports node and it is launched in the default web browser if Open in default Web Browser was selected Click on the name of the report and the details are displayed in the main screen of the console Faronics Power Save User Guide Exporting Printing and Emailing Power Save Reports 59 Exporting Printing and Emailing Power Save Reports Exporting Printing Email Power Save Reports can be exported to various formats printed or sent via e mail The reports can be exported to a txt csv xml or html file To export a report right click on the report and select Export Report In the Save As dialog that appears specify the File name
22. een Core Console and workstations is done by the Core Server There is one Core Server node for each connection between Core Console and a Core Server Workstations one for each Core Server Under the Workstations node are three sub nodes Managed Workstations Discovered Workstations and Custom Workstation Groups node where custom groups of workstations can be created and populated e Tasks one for each Core Server The Tasks node displays the current state of all Server tasks A task is defined as an action applied to one or more workstations Expanding the Tasks node displays three sub nodes for the states of a Task The Scheduled node displays tasks that are scheduled to run in the future The Active node displays tasks currently being processed The History node displays tasks that have already been completed Tasks older than a certain date are automatically deleted This can be configured through the Server tab of the Core Server Properties dialog e Reports under the root node Core Console displays reports created by Product Loadins If no Loadins are installed no reports can be generated Itis possible to use groups of workstations that already have been defined on a directory server Once the Core Agent has been installed on workstations discovered through LDAP those workstations can be managed directly through the LDAP groups node These workstations can also be added to custom groups Custom Workstation Gro
23. he workstation list based on predefined parameters Dynamic Custom Workstation Groups can be created based on the different departments in your organization physical locations and user groups For more information on Dynamic Custom Workstation Groups refer to the Faronics Core User Guide available at http www faronics com library Wake on LAN Across Subnets In a scenario where Wake on LAN WOL broadcast packets cannot always cross routers and other networking equipment and therefore cannot always wake up workstations on remote subnets it is possible to designate one or more workstations as WOL relays When Core Console attempts to wake up a workstation on a remote subnet it contacts a WOL relay on that subnet using it to re broadcast the wake up message on the target subnet For more information on Wake on LAN Across Subnets refer to the Faronics Core User Guide available at http www faronics com library Wake on LAN Web Interface In a scenario where Power Save is managing power on workstation s the Wake on LAN Web Interface allows you to wake up the workstations The workstation s can be woken up remotely after logging on to the corporate Virtual Private Network VPN For more information on Wake on LAN Web Interface refer to the Faronics Core User Guide available at http www faronics com library Faronics Power Save User Guide Topics 51 Power Save Reports Power Save provides various reporting features
24. ination Folder EN Clic o install to the default folder or click Browse to choose another Install Faronics Power Save Workstation to C Program Files Faronics Power Save Workstation 5 Click Install to complete the installation Faronics Power Save User Guide Installing Power Save Manually on a Workstation 25 i Faronics Power Save Workstation Setup Ready to install Faronics Power Save Workstation Click Install to begin the installation Click Back to review or change any of your installation settings Click Cancel to exit the wizard Suppress Reboot You can use the msi files to install Power Save on your network through a Server Group Policy Installing Power Save using the msi files will reboot the workstation after installation To prevent the reboot of workstations after installing Power Save you can use the mst with the suppress reboot option Associate the mst files with the msi files while creating an install package through your Server Group Policy The mst files are unpacked in the C Program Files Faronics Faronics Core Loadins Power Save directory Use Suppress_Reboot_32 bit mst for a 32 bit operating system and Suppress_Reboot_64 bit mst for a 64 bit operating system Faronics Power Save User Guide 26 Installing Power Save Applying Power Save License via Core Console If you are using the evaluation version of Power Save you can apply the license and convert it to a full version If
25. ings Application Control Windows Power Options Hardware Settings User Experience Administration Settings Energy Costs Configuration Settings Application Control Windows Power Options Hardware Settings Ver Gnas Administration Settings 5 Click Application Control A Power Schedule E Configuration Settings Application Control Windows Power Options Hardware Settings User Experience Administration Settings Energy Costs Application Control Y Do not manage power if the following applications are running Application Power Manage on Monitor E Ignore all activity contributed by the following checked application s I Application Application Name Do not manage power if the following applications are running this feature is useful when an important program is running for example a Power Point presentation Power Save can be Faronics Power Save User Guide Power Save Policy 35 instructed to avoid saving power when important programs are running and avoid interruptions for the user Select Do not manage power if the following applications are running Browse to select the Application Name and click Add Select an entry and click Remove to remove an application Ignore all activity contributed by the following checked applications this feature is useful when applications like anti virus programs run in the background and can be ignored by Power
26. installing Power Save Uninstalling Power Save on a Workstation Using Command Line 71 Faronics Power Save User Guide 72 Uninstalling Power Save Faronics Power Save User Guide
27. is software for ease of use and to be problem free If problems are encountered contact Technical Support Email support faronics com Phone 800 943 6422 or 1 604 637 3333 Hours 7 00am to 5 00pm Pacific Time Contact Information e Web www faronics com e Email sales faronics com Phone 800 943 6422 or 1 604 637 3333 e Fax 800 943 6488 or 1 604 637 8188 Hours 7 00am to 5 00pm Pacific Time e Address Faronics Technologies USA Inc 2411 Old Crow Canyon Road Suite 170 San Ramon CA 94583 USA Faronics Corporation 609 Granville St Suite 620 Vancouver BC V7Y 1G5 Canada Faronics Corporation Europe Siena Court The Broadway Maidenhead Berkshire SL6 1NJ UK Faronics Power Save User Guide 7 8 Power Save Definition of Terms Term Definition Actions Pane A part of the Core Console that displays actions such as configuring workstation options shutdowns Wake on LAN etc Console Tree Display Core Console properties workstations and groups scheduled tasks Pane and generated reports Context menu Power Save features are available by selecting one or more workstations and using the right click contextual menu Core Console The user interface used to manage and monitor Core Servers and workstations Core Database The database stores the workstation list Core Server The management of workstations processing of tasks and communication between Core Console and workstations
28. ivity is less than the specified value CPU activity is less than x percent Select the value in percent x percentage Select the value in percent Select the duration for sampling the activity to check if it is less than the selected value For example if the is set to 25 and sampling once every is set to 10 seconds the program will check for CPU activity every 10 seconds to determine if the utilization is below 25 Network Select the check activity is box to manage less than power when the network activity is less than the specified value x percent Select the value in percent x percentage Select the value in percent Select the duration for sampling the activity to check if it is less than the selected value For example if the is set to 25 and sampling once every is set to 10 seconds the program will check for Network activity every 10 seconds to determine if the utilization is below 25 4 Click OK Faronics Power Save User Guide Power Save Alerts 45 Power Save Alerts Administrators can configure Power Save to send alerts to specified users via email 1 2 Go to Console Tree Pane and click Alerts Specify the email ID of the user who should be notified notified in case of the following conditions License Expired or will expire in 30 days Workstation Running Older Version of Power Save Policy Adjustment Request when the user req
29. lShield Wizard License Agreement Please read the following license agreement carefully Power Save Loadin License Faronics Corporation Copyright 1999 2012 All Rights Reserved Master Software License Agreement LICENSE GRANT Faronics hereby grants the Licensee a limited non exclusive license to install use access display run or otherwise interact with Use the Product on a computer In no circumstances shall the Licensee be permitted to Use the Product on a mumbar nf sammntarn awaanding tha numbar af Iinnnnad ammutan nat and han 9 I accept the terms in the license agreement I do not accept the terms in the license agreement Version 4 50 3220 767 InstallShield 3 Enter the User Name Organization and the License Key If you do not have a License Key select the Use Evaluation check box The evaluation version of Power Save will stop functioning on the workstation after 30 days If you have already purchased Power Save you can get the License Key by logging into www faronicslabs com Click Next to continue Faronics Power Save User Guide 18 Installing Power Save JE Faronics Power Save Loadin InstallShield Wizard q Customer Information Please enter your information m Use Evaluation 30 days Version 4 50 3220 767 j Next gt cancel InstallShield 4 The default location is C Program Files Faronics Faronics Core 3 Loadins Power Save Click Next JE Faronics P
30. led feature that allows remote activation of the workstation Workstation The list of all workstations that have reported to Core Server This list is List displayed via Core Console This list also displays columns regarding workstation specific information Faronics Power Save User Guide 9 10 Power Save Faronics Power Save User Guide Topics Introduction This chapter introduces Faronics Power Save and specifies the system requirements Power Save Overview System Requirements Faronics Power Save User Guide 11 12 Introduction Power Save Overview About Power Save Faronics Power Save delivers PC power management that does not interfere with user or IT needs Power Save keeps computers running when users need them accurately determines when computers are inactive so they can be powered down and can prove its rapid return on investment through network wide power consumption and savings reports Power Save s non disruptive PC power management analyzes CPU disk keyboard mouse and network activity as well as application status before taking computer power management actions It is also available for both Windows and Mac computers With an average savings of 50 per computer per year for every computer deployed Power Save is the ultimate PC power management software solution for desktop and laptop computers About Faronics Core Faronics Power Save User Guide Faronics Core is a ligh
31. ll Power Save perform the following steps 1 Open Core Console 2 Click on the workstation icon in the left pane of the Console 3 Right click on the workstation s from which Power Save will be removed 4 Click on Configure workstations gt Advanced gt Uninstall Power Save Client Faronics Power Save User Guide 68 Uninstalling Power Save Uninstalling on a Workstation using the Uninstall Wizard Faronics Power Save User Guide When you install the Power Save Loadin the Power Save workstation installer files are unpacked in the C Program Files Faronics Faronics Core 3 Loadins Power Save Workstation Installer directory If the Enable workstation password protection option was selected in the during A installation specify the same password while uninstalling Power Save To uninstall Power Save double click PowerSave_Ent_32 bit msi on a 32 bit operating system and PowerSave_Ent_64 bit msi on a 64 bit operating system The Setup Wizard appears 1 Click Next to begin the uninstall 18 Faronics Power Save Workstation Setup Welcome to the Faronics Power Save Workstation Setup Wizard ent The Setup Wizard allows you to change the way Faronics POWER Power Save Workstation features are installed on your computer or to remove it from your computer Click Next to continue or Cancel to exit the Setup Wizard WwWw faronics com 2 Click Remove followed by Next Uninstalling on a Workstation using the Uni
32. n Command Mode Full or path PowerSaveConfig NoGui Mode full auditOnly Audit Only Display usage path PowerSaveConfig and syntax path PowerSaveConfig Help information Display Power path PowerSaveConfig NoGui v Save version path PowerSaveConfig NoGui Version Apply License PowerSaveConfig NoGui License License Key Key optional user input lt mandatory user input gt path location of the Power Save executable lt xmlConfigFile gt configuration file created by Power Save Example Command Line path PowerSaveConfig NoGui Version In the example above the Power Save version is displayed Installing Using Command Line Parameters Faronics Power Save User Guide Use the following command line parameters to install upgrade Power Save on a workstation To install Power Save on a 32 bit operating system msiexec q i path PowerSave Ent_32 bit msi To install Power Save on a 64 bit operating system msiexec q i path PowerSave Ent 64 bit msi path location of the Power Save executable Command Line Errors 63 Command Line Errors The command line displays the following unique error codes Error Description 0 Success 1 License Expired 2 Unrecognized Command 3 Invalid Parameter when parameter is not understood by Power Save 4 Operation not permitted in Current State 5 File not found 6 File permission error 7 Unrecognized file format 8 I
33. nconsistent configuration settings Faronics Power Save User Guide 64 Command Line Control Faronics Power Save User Guide Topics 65 Uninstalling Power Save Uninstalling the Power Save Loadin via Add or Remove Programs Uninstalling Power Save on a Workstation via Core Console Uninstalling on a Workstation using the Uninstall Wizard Faronics Power Save User Guide 66 Uninstalling Power Save Uninstalling the Power Save Loadin via Add or Remove Programs The Power Save Loadin can be uninstalled through Add Remove programs To do so click on Start gt Control Panel gt Add Remove Programs gt Faronics Power Save Loadin gt Remove Uninstalling the Power Save Loadin on the Core Server will remove it from the Core Server and Core Console on that computer All Power Save management capabilities with be removed from the Core Server Power Save will not be uninstalled automatically from multiple Core Consoles connecting to the same Core Server Uninstall manually from each computer where Core Console is installed with the Power Save Loadin Power Save will not be uninstalled automatically from the individual workstations Uninstall manually from individual workstations Faronics Power Save User Guide Uninstalling Power Save on a Workstation via Core Console 67 Uninstalling Power Save on a Workstation via Core Console Power Save can be removed from a workstation using Core Console To uninsta
34. new Energy Cost e Cost per KwH specify the cost in your area e Start Time select the time to start calculating Energy Cost e Days select the days to calculate Energy Cost r Add Energy Cost 12 Click Look up Energy Cost Select the Energy Cost and click OK This step is optional Faronics Power Save User Guide 40 Configuring Power Save r amp Look up Energy Cost Look up Energy Cost Power Save can provide estimated energy costs based on your location Contact your facility manager to get a more precise energy cost Country region Choose y Estimated power cost Note 1 Values provided are solely estimates based on third party data 2 To ensure accurate reporting please verify that your Core Console locale matches your Core Server locale 13 The Energy Costs are applied Click Apply Click OK Energy Costs The following costs are associated with the current policy Mo Tu We Th Fr Sa Su _ Cost yv vv v 9 yvy vyv vyv vo v vo Faronics Power Save User Guide Add or Modify a Power Schedule 41 Add or Modify a Power Schedule Complete the following steps to create a Power Schedule 1 Right click on the policy and select Policy Details 2 Click the Power Schedule Node Click Add F Policy Details Test Le kes Power Schedule H j E Configuration Settings P rS ule Application Control
35. ng down the computer This closes down all open network connections thereby preventing unauthorized users from misusing the open network connections Faronics Power Save User Guide 36 Configuring Power Save Faronics Power Save User Guide 7 Click Hardware Settings node 8 Policy Details Test ES Power Schedule j EJ Configuration Settings Ha S Settings Application Control Wake By Device o Allow the following checked devices to wake the computer jardware Settings me User Experience Y Keyboard Administration Settings Z Mouse Energy Costs Y Network Interface Card NIC Do not sleep standby if computer is designated as a WOL Relay E Do not manage power if the workstation is on a wireless network connection ok _ canca Apy Wake By Device select an input device that can wake up the computer Keyboard Mouse Network Interface Card Select Do not sleep standby if computer is designated as a WOL Relay This ensures that the computer will never go to sleep standby mode if it is designated as a WOL Relay This option keeps the computer running to wake other computers on the network Select Do not manage power if the workstation is on a wireless network connection This ensures that the computer will not go to sleep and disconnect wireless when connected to a wireless network Power Save Policy 37 8 Click User Experience node E odiar Salas U
36. nstall Wizard 69 18 Faronics Power Save Workstation Setup Change repair or remove installation Select the operation you wish to perform Chang Faronics Power Save Workstation has no independently selectable features Repairs errors in the most recent installation by fixing missing and corrupt files shortcuts and registry entries Remove Removes Faronics Power Save Workstation from your computer 3 Click Remove i Faronics Power Save Workstation Setup Ready to remove Faronics Power Save Workstation Click Remove to remove Faronics Power Save Workstation from your computer Click Back to review or change any of your installation settings Click Cancel to exit the wizard 4 Click Finish to complete the uninstall An immediate workstation restart is recommended following uninstall Faronics Power Save User Guide 70 Uninstalling Power Save Uninstalling Power Save on a Workstation Using Command Line Faronics Power Save User Guide Use the following command line parameters to uninstall Power Save on a workstation To uninstall Power Save on a 32 bit operating system msiexec q x path PowerSave Ent _32 bit msi To uninstall Power Save on a 64 bit operating system msiexec q x path PowerSave_ Ent 64 bit msi path location of the Power Save executable If the Enable workstation password protection option was selected in the during A installation specify the same password while un
37. om 2 Read and accept the License Agreement Click Next to continue 18 Faronics Power Save Workstation Setup End User License Agreement Please read the following license agreement carefully Power Save Workstation License Faronics Corporation Copyright 1999 2009 All Rights Reserved Master Software License Agreement LICENSE GRANT Faronics hereby grants the Licensee a limited non exclusive license to install use access display run or otherwise interact with Use the Product on a computer In no circumstances shall the Licensee be permitted to Use the Product on a number of computers exceeding the number of Licensed Computers set out above y I accept the terms in the License Agreement 3 Enterthe User Name Organization and the License Key If you do not have a License Key select the Use Evaluation check box The evaluation version of Power Save will stop Faronics Power Save User Guide 24 Installing Power Save functioning after 30 days If you have already purchased Power Save you can get the License Key by logging into www faronicslabs com Click Next to continue 18 Faronics Power Save Workstation Setup Customer Information Please enter your customer information User Name Faronics Organization Faronics Use Evaluation 4 Specify the install location The default is C Program Files Faronics Power Save Workstation Click Next 18 Faronics Power Save Workstation Setup Dest
38. om Version 4 50 3220 767 Once the Loadin has been successfully installed Core Console displays a list of Power Save specific features in the Actions pane when one or more workstations have been selected Power Save features are also available by selecting one or more workstations and using the right click contextual menu Faronics Power Save User Guide 20 Installing Power Save d The following screenshot displays the Power Save Loadin installed Q Faronics Core Console Faronics Core Console localhost FaronicsCoreAdmin Workstations Managed Workstations File Action View Help 69 25 Faronics Core Console Managed Workstations 1 workstation Faronics Core Server selected Actions localhost Fi icsCoreAdi n a ao concen Workstation Status Active Task Version Agent Note LastLogoffTime Curren Managed Workstations ooon n Al F Esi Workstations WIN OGAI42RTQJ 3 70 2100 3879 31 El Task Activity 3 Power Save Wakeup BE Discovered Workstations Custom Workstation Groups Tasks A Alerts al Reports Restart Shutdown Send Message Make Note Remote Launch Update Windows Faronics Core m Y oy Power Save Mode 600404a4a Reassign Policy fte Apply Energy Consumption Profile Install Upgrade Power Save Client b Uninstall Power Save Client fa Generate Report View G Refresh B Export List H Hep o Task Activity ha i 12 Wakeup E Restart
39. ower Save Loadin InstallShield Wizard Destination Folder Click Next to install to this folde Install Faronics Power Save Loadin to C Program Files Faronics Faronics Core 3 Loadins Power Save InstallShield 5 Click Install to begin the installation Faronics Power Save User Guide Installing Power Save Loadin 19 JE Faronics Power Save Loadin InstallShield Wizard Ready to Install the Program he wizard is ready to begin installation rt Click Install to begin the installation If you want to review or change any of your installation settings dick Back Click Cancel to exit the wizard InstallShield 6 Click Yes to restart the Faronics Core Server Click No to restart the Faronics Core Server later 4H Faronics Power Save Loadin InstallShield Wizard The Faronics Core Server service must be restarted in order to complete the installation successfully Restarting the Faronics Core Server service will disconnect all active sessions Would you like to do this now Select Yes to restart the Faronics Core Server service now Select No if you want to manually restart the Faronics Core Server service later InstallShield 7 Click Finish to complete the installation 4B Faronics Power Save Loadin InstallShield Wizard The InstallShield Wizard has successfully installed Faronics Power Save Loadin Click Finish to exit the wizard www faronics c
40. pplying Power Save License via Core Console Faronics Power Save User Guide 16 Installing Power Save Installation Overview Installation and configuration of Power Save involves the following stages e Installing Faronics Core and generating deploying the workstation Agent installer e Installing the Power Save Loadin e Deploying Power Save Installing Faronics Core For information on installing Faronics Core and generating and deploying the Core Agent refer to the Faronics Core user guide The latest user guide is available at http www faronics com library Faronics Power Save User Guide Installing Power Save Loadin 17 Installing Power Save Loadin The Power Save Loadin is installed on the Core Server using the PowerSaveLoadin exe file The Power Save Loadin cannot be installed on a system that does not already have Faronics Core installed To install the Power Save Loadin complete the following steps 1 Double click the PowerSaveLoadin exe file to begin the installation process Click Next to continue 18 Faronics Power Save Loadin InstallShield Wizard Welcome to the InstallShield Wizard for Faronics Power Save Loadin The InstallShield R Wizard will install Faronics Power Save Loadin on your computer To continue dick Next WARNING This program is protected by copyright law and international treaties Wwnw faronics com Version 4 50 3220 767 18 Faronics Power Save Loadin Instal
41. r this event to take effect wake up from hibernate or standby mode only select this option if you want Power Save to wake up the workstation Shutdown select this option if you want to create an event to shutdown the computer at a predefined time Dynamic Configuration select this option to set a dynamic configuration Select the option from the slider The options extend from Lower User Disruption to Increased Power Saving Dynamic Configuration starts by default from computer startup Advanced Settings select the following options that appear on selecting Advanced Settings Begin Power Management select on computer startup to begin power management as soon as the computer starts Alternatively select after first keyboard mouse activity Complete the following options for inactivity timeout Description Description When running on Add or Modify a Power Schedule 43 Description Batteries Turn off Select the check x minutes Selectthenumeric x minutes Select the numeric monitor if box to turn off the d value and specify d value and specify if Keyboard Mo monitor after the Sener ifitisminutesor O7S it is minutes or use are specified time seconds when seconds when the inactive for interval plugged in computer is running on batteries Turn offhard Select the check x minutes Selectthenumeric x minutes Select the numeric disk if box to turn off the d value and specify d value and spe
42. ser Experience Application Control User Notification a a Y Notify user of Power Save actions 30 a Energy Costs Faronics Power Save will now take power saving action on this machine Stealth Mode Stealth Mode hides elements of the Faronics Power Save interface from the user Hide taskbar notification area icon Hide Eco Facts message User Input Allow users to temporarily defer workstation power management for 2 y hours Allow users to schedule local wake up and defer power management up to 4 3 hour s From Standby and Hibemate only ok cae _ ao e Select Notify user of Power Save actions x seconds in advance You can customize the message by editing the Notification Message e Stealth Mode select the following options to hide user interface elements of Power Save from the user Hide taskbar notification area icon Hide Eco Facts message e User Input select the following options e Allow users to temporarily defer workstation power management for x hours This allows users to defer workstation power management for a predefined interval e Allow users to schedule local wake up and defer power management up to x hours This allows usres to schedule a local wake up and defer power management for a predefined interval Faronics Power Save User Guide 38 Configuring Power Save 9 Click Administration Settings Policy Details Te
43. st a Power Schedule Ini a eis Administration Settings Application Control Windows Power Options Save Open Documents Hardware Settings User Experience Y Attempt to save a copy of any open document s in the following location Administration Settings UserProfile My Documents Files Saved by Power Save Y Notify user if a copy of the document was saved Password Protection E Enable command line control password The Faronics Power Save client can be deployed and managed via command line control For greater security you may wish to enable a password ok Cancel Anny e Select Attempt to save a copy of any open document s in the following location Specify the path The default path is User Profile My Documents Files Saved by Power Save Select Notify user if a copy of the document was saved to inform the user of this action e Select Enable command line control password to ensure security while managing Power Save via command line Faronics Power Save User Guide Power Save Policy 39 10 Click Energy Costs E Policy Details Test a Power Schedule E Configuration Settings Application Control The following events are associated with the current policy Windows Power Options Hardware Settings User Experience Administration Settings Energy Costs Energy Costs Select an event to modify its properties 11 Click Add to add a
44. tions in the right pane and select Install Upgrade Power Save Client option to Suppress Reboot If you Suppress Reboot Power Save will not work The workstation reboots after a successful install Power Save will give you an until the workstation reboots Power Save can be accessed by right clicking a workstation selecting Power Save i If there is more than one Loadin installed the right click contextual menu for and then selecting the particular action Faronics Power Save User Guide Installing Power Save Manually on a Workstation 23 Installing Power Save Manually on a Workstation When you install the Power Save Loadin the Power Save workstation installer files are unpacked in the C Program Files Faronics Faronics Corel Loadins Power Save directory To install Power Save on a workstation double click PowerSave_Ent_32 bit msi on a 32 bit operating system and PowerSave_Ent_64 bit msi on a 64 bit operating system Repeat the process for each workstation that will be managed with Power Save To install Power Save on a workstation manually do the following 1 Double click on the msi file to begin the installation process Click Next to continue 18 Faronics Power Save Workstation Setup Welcome to the Faronics Power Save ES Workstation Setup Wizard patie The Setup Wizard will install Faronics Power Save POWER Workstation on your computer Click Next to continue or Cancel to exit the Setup Wizard www faronics c
45. tweight high performance secure easy to learn and integrated framework for the management of multiple Faronics products It provides a consistent and reliable method of displaying managing installing updating and protecting workstations and servers from a single console allowing your organization to increase efficiency with a complete management solution for Faronics products System Requirements 13 System Requirements Power Save Requirements The Power Save Loadin requires Faronics Core Power Save on the workstation computer requires any of the following operating systems e Windows XP SP3 32 bit or Windows XP SP2 64 bit e Windows Vista 32 bit or 64 bit e Windows 7 32 bit or 64 bit e Windows 8 32 bit or 64 bit It is highly recommended that all components be installed using a Windows Administrator account Faronics Core Requirements Faronics Core 3 2 or higher is required Information on Faronics Core system requirements can be found in the Faronics Core user s guide The latest user guide is available at http www faronics com library Faronics Power Save User Guide 14 Introduction Faronics Power Save User Guide Topics 15 Installing Power Save This chapter describes the installation process of Power Save Installation Overview Installing Power Save Loadin Installing or Upgrading Power Save on a Workstation via Core Console Installing Power Save Manually on a Workstation A
46. uest power policy adjustment to decrease or increase sensitivity Faronics Power Save User Guide 46 Configuring Power Save Configuring Power Save Manually on a Workstation The following features are accessible by right clicking the Power Save Icon in the Windows System Tray Stay Awake e Select Stay Awake gt Enable for gt x hours for to keep computers awake by temporarily disabling workstation power management Select a value for x from the menu e Select Resume Power Management to enable power management by Power Save up to x hours check box is selected in Administrator gt Workstation Options This option is available only if the Allow users to keep their computers awake for sub node via the Power Save Loadin in Core Console Schedule Computer Wakeup Select the following options to schedule the computer to wakeup at a particular time Schedule Computer Wakeup Faronics Power Save can schedule a local wakeup on this computer if it is in Standby or Hibernate mode Wakeup this computer at Time 08 00 AM Frequency MAME Y Defer power management for up to 1 ov hour s after wakeup e Select Schedule Computer Wakeup e Select Wakeup this computer at and select the Time and Frequency e Select Defer power management for up to x hour s after wakeup to defer power management defer power management to for up to x hours check box is selected in the Power Save Policy via the Power Save Loa
47. ups Workstations can be added to a custom group by standard Windows clipboard functionality Cut copy or paste along with drag and drop a workstation into a group To create a group right click on the Custom Workstation Groups icon and select Create Subgroup You can also add or edit Dynamic Filters and perform Group Actions The Workstation List and Tasks are stored on the Core Server whereas the A Reports are stored locally on the computer where Core Console is installed Information on Faronics Core system requirements can be found in the Faronics Core user s guide The latest user guide is available at http www faronics com library Faronics Power Save User Guide 22 Installing Power Save Installing or Upgrading Power Save on a Workstation via Core Console Power Save can be deployed by Installing or Upgrading Power Save via the Core Console The Core Agent which is part of Faronics Core must be installed on each workstation that will be managed by Power Save For more information on installing the Workstation Agent Installer refer to the Faronics Core user guide The latest user guide is available at http www faronics com library Once the Core Agent is installed the workstations are detected on the network and visible in Core Console You can now Install or Upgrade Power Save on the workstations To install or upgrade Power Save select a single workstation or multiple workstations click Configure Worksta