Contents

1. or straight connecting parts perma tec GmbH amp Co KG perma PRO PRO C MP 2 Determine Discharge Period Check the lubrication specifications of your application for the correct discharge amount and times per lubrication point that the PRO PRO C MP 2 distributor outlet should discharge If necessary calculate this amount in cc per 100 operating hours Double this figure to get the total lubricant amount in cc for 100 operating hours two lubrication points receive the same amount of lubricant Go to the chart in the PRO PRO C operating manual chapt 6 7 Find your previously determined total lubricant amount in the chart The chart will tell you the correct lubricator setting depending on the size of the PRO LC unit Calculation example Lubrication data listed on the specification plate of an electric motor 150 cc 4000 h lubricant per bearing 2 bearings This amounts to 3 75 cc per 100 operating hours 1 Each outlet of the distributor PRO PRO C MP 2 must discharge 3 75 cc per 100 hours Total discharge amount that the lubrication system must discharge 7 5 cc per 100 operating hours 3 75 cc times 2 outlets 100 h 2 The chart on chapt 6 7 of the PRO PRO C operating manual shows the following setting 20 weeks discharge with lubricant cartridge PRO LC 250 or 3 9 months discharge with cartridge PRO LC 500 Conformity Declaration 1 2 The World of Automatic Lubrication 08 12 15 EC declaration of conf
2. ives referred to but it is not a warranty of qualities The safety instructions of the operating manual are to be observed Directive 98 37 EC is valid until and including the 28 of December 2009 Directive 2006 42 EC is valid as of 29 December 2009
3. ormity according to the Machinery Directive 98 37 EC and to EMV Electromagnetic Compatibility Directive 2004 108 EC according to the Machinery Directive 2006 42 EC and to EMV Electromagnetic Compatibility Directive 2004 108 EC The manufacturer perma tec GmbH amp Co KG Hammelburger Strake 21 D 97717 Euerdorf hereby declares that the product as described in the given statement conforms to the regulations appertaining to the directives referred to above including any amendments thereto which are in force at the time of the declaration Product description Automatic lubrication system Product name Lubrication system perma PRO MP 2 or perma PRO C MP 2 Type perma PRO 250 MP 2 or perma PRO C 250 MP 2 perma PRO 500 MP 2 or perma PRO C 500 MP 2 The following harmonized standards were applied EN ISO 12100 1 2003 Safety of machinery basic concepts general terms of reference as regards design and construction Section 1 Basic Terminology Methodology EN ISO 12100 2 2003 Safety of machinery basic concepts general terms of reference as regards design and construction Section 2 Technical terms of reference EN 60204 1 2006 Machinery s electrical equipment Euerdorf 15 December 2008 perma tec GmbH amp Co KG Walter Graf Managing Director Egon Eisenbacher Technical Management and authorized documentation representative see manufacturer address This declaration certifies conformity to the direct
4. perma tec GmbH amp Co KG perma PRO PRO C MP 2 Translation of the Original Operating Instructions perma PRO PRO C MP 2 The World of Automatic Lubrication perma tec GmbH amp Co KG The perma PRO PRO C MP 2 lubrication system supplies 2 lubrication points with the same amount of lubricant It is mainly used for lubrication on motors fans and pumps Please note that this perma PRO PRO C MP 2 operating manual must always be used together with the operating manual for perma PRO PRO C The basic function of perma PRO PRO C does not change The only difference is that the lubri cant amount is distributed evenly between two lubrication points The perma PRO PRO C operating manual remains valid Any differences of the 2 point distribution are covered in this ope rating manual which should be used in addition to the perma PRO PRO C operating manual ATTENTION rN The lubrication system perma PRO PRO C MP 2 only functions with the distributor PRO PRO C MP 2 If the distributor is disconnected the lubrication system does not work Technical Data dL pera PROT PROC MP2 Distributor OO Connection thread for grease line G1 8 inside Diameter of grease line 8x1 5 Inside 5mm eaeh ohe are ceine admissible total length per line up to 5 m For details please regard g g operating manual PRO PRO C chapter 3 page 7 Emission sound pressure level lt 70 dB A Storage conditions Dry dust free at temperature
5. s of 20 C 5 C 68 F 9 F ATTENTION VAN Never close an outlet and never connect a grease line with more than 25 bar counter pressure Doing so will cause a system malfunction Delivery content Amount Partname o O Ordernumber Part PRO MP 2 Basic system 2290 008 690 1 PRO Drive with PRO MP 2 Distributor PRO MP 2 Accessory Box 2 Tube Connector G1 8a for tube a 8 mm 90 2 Tube Connector G1 8a for tube a 8 mm straight 1 PRO Mounting Device 1 PRO Battery B PRO C MP 2 Basic system 1 PRO C Drive with PRO MP 2 Distributor PRO MP 2 Accessory Box 2 Tube Connector G1 8a for tube a 8 mm 90 2 Tube Connector G1 8a for tube a 8 mm straight 1 PRO Mounting Device 1 PRO C M12 Cable 5 m Following parts must also be ordered for a complete system XXXX grease number 1 PRO LC 250 PRO LC 500 222 XXXX 608 223 XXXX 609 1 PRO Cover for LC 250 PRO Cover for LC 500 2299 101 000 2299 102 000 PRO tube 8 x 1 5 per meter a please state desired length on your order ey 009 093 o The World of Automatic Lubrication perma PRO PRO C MP 2 Lubrication system perma PRO PRO C MP 2 Installation dimensions lt 102 mm 92mm 270 mm for lubricators with LC 250 321 mm for lubricators with LC 500 DO NOT disconnect distributor ATTENTION A DO NOT loosen lt 67 mm distributor assembly Screws 49 mm gt Assembly 2 connection threads G1 8 for angled