        INSTALLATION MANUAL
         Contents
1.            Z  CAUTION    Min  allowable length    3  Ea    PE  a    Right back piping    T    75 Right bottom piping   lt  gt            Left right piping           45                  The suggested shortest pipe length is 2 5m  in order to avoid noise from the outdoor unit and vibration      Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used      e See the installation manual for the outdoor unit for the maximum pipe length      For multi connections  see the installation manual for the multi outdoor unit                 Refrigerant pipe                               2  Boring a wall hole and installing wall embedded pipe    e For walls containing metal frame or metal board  be sure to use a    wall embedded pipe and wall cover in the feed through hole to  prevent possible heat  electrical shock  or fire     e Be sure to caulk the gaps around the pipes with caulking material    to prevent water leakage     1  Bore a feed through hole of 65mm in the wall so it has a down    slope toward the outside     2  Insert a wall pipe into the hole   3  Insert a wall cover into wall pipe     4  After completing refrigerant piping  wiring  and drain piping     caulk pipe hole gap with putty     Inside  lt  gt  Outside  Wall embedded pipe     Field supply            Wall hole cover   Field supply        Caulking         65     __ Wall embedded pipe   Field supply     3  Drain piping    1  Use commercial rigid polyvinyl c
2.         Flaring       Set exactly at the position shown below     Y A Flare tool for R410A Conventional flare tool   Cut exactly 7  AR a 5  at right Remove i Clutch type Clutch type  Rigid type    Wing nut type  Imperial type   angles   burrs   Die    A 0 0 5mm 1 0 1 5mm 1 5 2 0mm             Make sure that the  flare nut is fitted                                      7 English    6  Connecting the refrigerant pipe  Z  CAUTION    1  Use the flare nut fixed to the main unit   To prevent cracking of the flare nut by aged deterioration    2  To prevent gas leakage  apply refrigeration oil only to the inner surface of the flare   Use refrigeration oil for R410A    3  Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage     Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand  Then tighten them fully with the torque wrenches      Apply oil     Apply refrigeration oil to  the inner surface of the  flare  uf     Tighten     Do not apply refrigeration  oil to the outer surface     Torque wrench             Flare nut    Spanner          Piping union  Do not apply refrigeration  oil to the flare nut avoid    Flare nut    tightening with over torque                                Flare nut tightening torque  Gas side Liquid side  25 35 class 50 class 25 35 50 class  3 8 inch 1 2 inch 1 4 inch  32 7 39 9N m 49 5 60 3N m 14 2 17 2N m   333 407kgf cm   505 615kgf cm   144 175kgf cm                                
3.       6 1  Caution on piping handling Tn Wall        i i   i Be sure to  1  Protect the open end of the pipe against dust and moisture    place a cap   2  All pipe bends should be as gentle as possible  Use a pipe bender Rain If no flare cap is a  for bending  CA he  mathe  Ne wi h tape to keep  gt    6 2  Selection of copper and heat insulation    ee  materials    When using commercial copper pipes and fittings  observe the following  Papa  1  Insulation material  Polyethylene foam wiring  Heat transfer rate  0 041 to 0 052W mK  0 035 to 0 045kcal  mh C   Ses pibe Liquid pipe  Refrigerant gas pipe s surface temperature reaches 110  C max  A    Choose heat insulation materials that will withstand this temperature   O O   Gas pipe Liquid pipe  insulation  Finising tape insulation    2  Be sure to insulate both the gas and liquid piping and to provide insulation dimensions as below                                   Gas side Gas pipe thermal insulation Liquid pipe  25 35 class 50 class Piquid side  lao class 50 class cine  insulation  O D  9 5mm   O D  12 7mm   O D 6 4mm_   I D  12 15mm   I D  14 16mm   1 D  8 10mm  Minimum bend radius Thickness 10mm Min   30mm or more   40mm or more   30mm or more                Thickness 0 8mm  C1220T O        3  Use separate thermal insulation pipes for gas and liquid refrigerant pipes     English    Indoor Unit Installation  1     7  Checking for gas leakage    1  Check for leakage of gas after air purging    2  See the sections on air purge
4.  E For Moldings    e Remove the pillars   Remove the slit portions on the bottom  frame using nippers      Z 2  Upper casing    E For Side Piping    a     Remove the pillars   1  Remove the 7 screws  Ly  2  Remove the upper casing  2 tabs   ge  3  Remove the left and right casings  2 tabs on each side      4  Remove the slit portions on the bottom frame and casings 3  Side casings   1a   using nippers  a   5  Return by following the steps in reverse order  3  gt  2  gt  1   Ree Serews     IN    3  Side  casings                                                                            Remove the pillar     For Moldings       For Side Piping      TF     Casing IL Casing    Bottom frame       Remove the pillar        Remove the pillar     SSE                                                    English 6       Indoor Unit Installation  1     4 2  Installation  e Secure using 6 screws for floor installations   Do not forget to secure to the rear wall    e For wall installations  secure the O  mounting plate using 5 screws and the indoor unit using 4 screws     The mounting plate should be installed on a wall which can support the weight of the indoor unit   1  Temporarily secure the mounting plate to the wall  make sure that the panel is completely level  and mark the boring    points on the wall   2  Secure the mounting plate to the wall with screws        The mounting plate  should be installed on a  wall which can support the  weight of the indoor unit              Floor Instal
5.  of wires for electrical connections between the indoor and outdoor units    Firmly clamp the interconnecting wires so their terminals receive no external stresses  Incomplete connections or clamping may cause terminal overheating or fire     After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force    on the electrical covers or panels   Install covers over the wires  Incomplete cover installation may cause terminal overheating  electrical shock  or fire                                         e If any refrigerant has leaked out during the installation work  ventilate the room  Q   The refrigerant produces a toxic gas if exposed to flames     e After all installation is complete  check to make sure that no refrigerant is leaking out  Q   The refrigerant produces a toxic gas if exposed to flames         e When installing or relocating the system  be sure to keep the refrigerant circuit free from substances other than the  specified refrigerant  R410A   such as air    Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture  resulting in injury      During pump down  stop the compressor before removing the refrigerant piping   If the compressor is still running and the stop valve is open during pump down  air will be sucked in when the refrigerant piping is removed   causing abnormal pressure in the freezer cycle which will lead to breakage and even injury   e 
6. DAIKIN    y          INSTALLATION    MANUAL       R410A Split Series    INVERTER gt                                                                 Models   FVXS25FV1B  FVXS35FV1B  FVXS50FV1B    Installation manual  R410A Split series    Installationsanleitung  Split Baureihe R410A    Manuel d   installation  S  rie split R410A    Montagehandleiding  R410A Split systeem    Manual de instalaci  n  Serie Split R410A    Manuale d   installazione  Serie Multiambienti R410A    Eyxeipidio EyKAT    OTAONS  diaipo  evns CEIPAG R410A    Manual de Instalac  o  S  rie split R410A    PykKOBOJCTBO NO MOHTaXKy  Cepna R410A c pa3AaenbHo   ycTaHoBKOM    Montaj k  lavuzlar    R410A Split serisi    English    Deutsch    Fran  ais    Nederlands    Espa  ol    Italiano    EMAnvik      Portugues    Pycckn      T  rk  e    Safety Precautions    e Read these Safety Precautions carefully to ensure correct installation     This manual classifies the precautions into WARNING and CAUTION   Be sure to follow all the precautions below  they are all important for ensuring safety     A WARNING                 Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury     AN CAUTION    Failure to follow any of CAUTION may result in grave consequences in some cases     e The following safety symbols are used throughout this manual        Q Be sure to observe this instruction     Be sure to establish an earth connection  S Never attempt                    After 
7. During installation  attach the refrigerant piping securely before running the compressor   If the compressor is not attached and the stop valve is open during pump down  air will be sucked in when the compressor is run  causing  abnormal pressure in the freezer cycle which will lead to breakage and even injury   e Be sure to establish an earth  Do not earth the unit to a utility pipe  arrester  or telephone earth   Incomplete earth may cause electrical shock  or fire  A high surge current from lightning or other sources may cause damage to the air conditioner  B  e Be sure to install an earth leakage breaker   Failure to install an earth leakage breaker may result in electric shocks  or fire                          CAUTION    e Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage  O  If the gas leaks and builds up around the unit  it may catch fire      Establish drain piping according to the instructions of this manual   Inadequate piping may cause flooding              e Tighten the flare nut according to the specified method such as with a torque wrench   If the flare nut is tightened too hard  the flare nut may crack after a long time and cause refrigerant leakage              1 English    Accessories  GET A 0                Mounting plate 1       Insulation sheet 2      AAA dry cell batteries 2   Titanium Apatite Photocatalytic  113    Wireless remote controller 1      Operation manual 1  Air Purifying Filter      D
8. attaching main unit  The rear of the unit can be fixed with screws at the points shown in the illustration as below  Be sure to install the  supplemental plate in accordance with the depth of the inner wall     644 95  Unit  mm              Supplemental plate   Field supply     Screw hole       Screw hole    y 1S   Ga  Fixing point 1504 es ey 1  on the back bes    Opening hole 230   i      3   250          al                                      Supplemental plate   Field supply     200                         Z  CAUTION    1  The supplemental plate for installing the main unit must be used  or there will be a gap between the unit and the wall     3  Refrigerant piping    See 1  Refrigerant piping under Indoor Unit Installation  1                                                                                      Wall  Unit  mm   Left bottom piping Right bottom piping Y H   Hole locati ga aa q  att da a   ME E  oy Right left piping    O ZZY 7 1 Wall  i    e     Uam     3 8       lo  gt           gt   75 75 50    11 English    4  Installing indoor unit    1  Remove the front grille    2  Remove 7 screws    3  Remove the upper casing  2 tabs     4  Remove the side casings  2 tabs on each side     5  Attach the indoor unit to the wall and secure using screws in 6 locations  M4 x 25L                                                                                                                                                               Side casing       6 screws    Remove 7 s
9. ce                y             Upper lattice  must not                                     15 20                A          project                      70  or more             P  of open rate a              partition plate                      Movable lattice             410                                                                                                                40 or less  20 30    13    120          70 or more       English    1  Refrigerant piping                                                                                                                            Left bottom piping Right bottom piping CZI niente   Hole location f 7  Te   at   Right left piping   lt  l     i 7 7 J   oF 2  75 75  g g     2  Changing upward air flow dipswitch  Change the upward air flow dipswitch  SW2 4  to ON to limit the upward air flow   1  Remove the front grille   2  Switch the dipswitch  SW2 4  on the PCB in the electrical equipment box to ON     How to set and use the switch  amier P   a   Switch number SW2 4  123 4 a a Set function Upward air flow limit  ON r  Gears _ a  000  ale      Upward air flow dipswitch ee T OFF OFF  f Use Switch to on for    embedded units    Factory setting OFF                         Z  CAUTION  Be sure to turn on the upward air flow switch  Failure to do so may cause incomplete cooling heating and formation of  condensation inside the house     NOTE   For refrigerant piping  Boring a wall hole and installing wall embedded pipe  d
10. completing installation  test the unit to check for installation errors  Give the user adequate instructions concerning the use  and cleaning of the unit according to the Operation Manual       N WARNING    Installation should be left to the dealer or another professional   Improper installation may cause water leakage  electrical shock  or fire     e Install the air conditioner according to the instructions given in this manual   Incomplete installation may cause water leakage  electrical shock  or fire   e Be sure to use the supplied or specified installation parts   Use of other parts may cause the unit to come to lose  water leakage  electrical shock  or fire   e Install the air conditioner on a solid base that can support the weight of the unit   An inadequate base or incomplete installation may cause injury in the event the unit falls off the base   e Electrical work should be carried out in accordance with the installation manual and the national electrical wiring  rules or code of practice  Insufficient capacity or incomplete electrical work may cause electrical shock or fire        Be sure to use a dedicated power circuit  Never use a power supply shared by another appliance     e For wiring  use a cable length enough to cover the entire distance with no connection    Do not use an extension cord  Do not put other loads on the power supply  use a dedicated power circuit     Failure to do so may cause abnormal heat  electric shock or fire       Use the specified types
11. crews   M4 x 25L  Field supply     A CAUTION    1  Use drain pan edge for horizontal projection of the indoor unit   2  Install the indoor unit flush against wall     NOTE    For refrigerant piping  Boring a wall hole and installing wall embedded pipe  drain piping  installing indoor unit   flaring the pipe end  connecting the refrigerant pipe  checking for gas leakage  attaching the connection pipe   connecting the drain hose  wiring  when connecting to an HA system  see Exposed Installation        English 12    Indoor Unit Installation  3     Concealed installation    Only items peculiar to this installation method are given here  See Exposed Installation for additional instructions     Install the unit according to the instructions below  Failure to do so may cause lead to both cooling and heating failure    and the condensation inside the house   1  Allow enough space between the main unit and ceiling not to obstruct the flow of cool warm air   2  Place a partition plate between outlet and inlet sections   3  Place a partition plate on the right side   4  Change the upward blow limit switch   5  Use a movable lattice at the air outlet to allow the adjustment of cool warm air flow direction   6  Lattice size should be 70  or more of open rate                          aa Right side partition plate                                   gt   gt   Partition plate                   50 or more 50 or more     Unit  mm     Right side partition plate    partition plate    Movable latti
12. em to the heat pump side        Dipswitches                      English 2    Indoor Unit Installation Drawings    The indoor unit may be mounted in any of the three styles shown here     Exposed Half concealed Concealed         PITT    Floor Installation Wall Installation                Location for securing the installation panel                 as  574   600                  70mm or more    50mm or more  from walls  Titanium Apatite Photocatalytic   Air Purifying Filter  2   gt   SZ    Front panel          50mm or more  from walls    Caulk pipe  hole gap  with putty                        Remote controller    Va holder                   Screws   Field supply  M3 x 20L        3 English    Installation Tips    1  Removing and installing front panel    e Removal method  1  Slide until the 2 stoppers click into place   2  Open the front panel forward and undo the string   3  Remove the front panel     e Installation method  1  Attach the front grille and front panel after pulling the string  around them   2  Close the front panel and slide until the stoppers click outside     2  Removing and installing front grille    e Removal method  1  Open the front panel   2  Remove the 4 screws and remove the front grille while pulling  it forward  3 tabs      e Installation method  1  Secure the front grille with the 4 installation screws  3 tabs    2  Return the front panel to the original position     3  How to set the different addresses    When two indoor units are installed in one 
13. hloride pipe  general VP 20 pipe  outer diameter 26mm  inner diameter 20mm  for the drain pipe   2  The drain hose  outer diameter 18mm at connecting end  220mm long  is supplied with the indoor unit  Prepare the drain  pipe picture below position     3  The drain pipe should be inclined downward so that water will flow smoothly without any accumulation   Should not be trap    4  Insert the drain hose to this depth so it won   t be pulled out of the drain pipe   5  Insulate the indoor drain pipe with 10mm or more of insulation material to prevent condensation   6  Remove the air filters and pour some water into the drain pan to check the water flows smoothly   SL  Unit  mm   A ae    150         Insert drain hose     gt   1  to this depth so    A l  it won t be pulled Must be no trap   o out of drain pipe       IN 2 Y                                                    100 3 220    Do not touch water      O  Drain hose 50mm  Y or more v  Reducer il   VW   N Vinyl chloride Vi   Vinyl chloride     drain pipe  drain pipe if  VP 30    VP 20                       Z  CAUTION    Use polyvinyl chloride adhesive agent for gluing  Failure to do so may cause water leakage     4  Installing indoor unit    4 1  Preparation    e Open the front panel  remove the 4 screws and dismount the  front grille while pulling it forward          Remove  front grille    e Follow the procedure below when removing the slit portions                                Remove 4 screws  g    Open the front panel  
14. l    Live the sensor securing plate  remove the front metal plate cover  and connect the branch wiring to the terminal block   Strip wire ends  15mm     Match wire colours with terminal numbers on indoor and outdoor unit s terminal blocks and firmly screw wires to the  corresponding terminals    Connect the earth wires to the corresponding terminals    Pull wires to make sure that they are securely latched up  then retain wires with wire retainer    Make sure that the wires do not come in contact with the metal conduit for the heat exchanger    In case of connecting to an adapter system  Run the remote controller cable and attach the S21   Refer to 11  When  connecting to an HA system         Sensor securing plate       gt         Firmly fix the wires with  the terminal screws                          Outdoor unit                Shape wires so  that the front metal 1 When wire length exceeds 10m     20    12 3    LN   plate cover will fit                   Electrical use 2 0mm diameter wires  E at   ly    SECUTI  SN LA l  component E H z    box                                                                                                                                                   Firmly secure wire Indoor 2  retainer so that     OUl  Wire retainer unit ES y 2      wires sustain no  external stress  An Firmly fix the wires with HO5VV  Use the specified the terminal screws   wire type                 plate cover  Make sure that the wires  Y do not come in contact  with 
15. lation Wall Installation O Mounting plate    ON  yee oe          a  zA     SS SF LL           5 screws   M4 x 25L    Field supply                                                                 6 screws  M4 x 25L  Field supply  4 screws  M4 x 25L  Field supply  Molding    3  Once refrigerant piping and drain piping connections are complete  fill in the gap of the through hole with putty   A gap can lead to condensation on the refrigerant pipe  and drain pipe  and the entry of insects into the pipes   4  Attach the front panel and front grille in their original positions once all connections are complete     5  Flaring the pipe end    Cut the pipe end with a pipe cutter    Remove burrs with the cut surface facing downward so that the chips do not enter the pipe   Fit the flare nut on the pipe    Flare the pipe    5  Check that the flaring is properly made     Z  WARNING    1  Do not use mineral oil on flared part    2  Prevent mineral oil from getting into the system as this would reduce the lifetime of the units    3  Never use piping which has been used for previous installations  Only use parts which are delivered with the unit   4  Do never install a drier to this R410A unit in order to guarantee its lifetime   5   6     1  2  3  4    TS    The drying material may dissolve and damage the system   Incomplete flaring may cause refrigerant gas leakage          The pipe end must  be evenly flared in  a perfect circle              Flare s inner  surface must  be scratch free   
16. or exhaust has clear path of air  Incomplete cooling heating  Stop valves are opened  function  Indoor unit properly receives remote controller commands  Inoperative  15 English          DAIKIN INDUSTRIES  LTD  DAIKIN EUROPE NV   Head office  Zandvoordestraat 300  B 8400 Oostende  Belgium  Umeda Center Bldg   2 4 12  Nakazaki Nishi    Kita ku  Osaka  530 8323 Japan    Tokyo office    JR Shinagawa East Bldg   2 18 1  Konan   Minato ku  Tokyo  108 0075 Japan  http   www daikin com global_ac        Two dimensional bar code is a code  for manufacturing           3P191292 1F  MO6B131E coro fr                      
17. rain hose 1       Remote controller holder 1    O  Installation manual 1                            Choosing an Installation Site    e Before choosing the installation site  obtain user approval     1  Indoor unit    The indoor unit should be sited in a place where   1  the restrictions on installation specified in the indoor unit installation drawings are met   2  both air intake and exhaust have clear paths met   3  the unit is not in the path of direct sunlight   4  the unit is away from the source of heat or steam   5  there is no source of machine oil vapour  this may shorten indoor unit life    6  cool  warm  air is circulated throughout the room   7  the unit is away from electronic ignition type fluorescent lamps  inverter or rapid start type  as they may shorten the  remote controller range   8  the unit is at least 1 metre away from any television or radio set  unit may cause interference with the picture or sound      2  Wireless remote controller    1  Turn on all fluorescent lamps in the room  if any  and find site where remote controller signals are properly received by  the indoor unit  within 7m      2  Make the dipswitch settings  Set according to the type of unit purchased by the customer  The default settings are on the  heat pump side   e For cooling only  Set the dipswitches on the cooling only side              Dipswitches             e For heat pump  Check that the dipswitches are on the heat pump side   If they are set on the cooling only side  move th
18. rain piping  installing indoor unit     flaring the pipe end  connecting the refrigerant pipe  checking for gas leakage  attaching the connection pipe   connecting the drain hose  wiring  when connecting to an HA system  see Exposed Installation     English 14    Trial Operation and Testing    1     2     Trial operation and testing    1 1 Measure the supply voltage and make sure that it falls in the specified range   1 2 Trial operation should be carried out in either cooling or heating mode     E For Heat pump    In cooling mode  select the lowest programmable temperature  in heating mode  select the highest programmable  temperature   1  Trial operation may be disabled in either mode depending on the room temperature   Use the remote controller for trial operation as described below   2  After trial operation is complete  set the temperature to a normal level  26  C to 28  C in cooling mode  20  C to 24  C in  heating mode    3  For protection  the system disables restart operation for 3 minutes after it is turned off     E For Cooling only    Select the lowest programmable temperature   1  Trial operation in cooling mode may be disabled depending on the room temperature   Use the remote controller for trial operation as described below   2  After trial operation is complete  set the temperature to a normal level  26  C to 28  C    3  For protection  the unit disables restart operation for 3 minutes after it is turned off     1 3 Carry out the test operation in accordance 
19. room  the two  wireless remote controllers can be set for different addresses   1  Remove the front grille    2  Live the sensor securing plate and remove the front metal plate cover     Remove connectors 5P  6P  and 7P     Remove the electric box  1 screw      Remove the thermistor              Remove 4 screws     Remove the side metal plate cover  7 tabs    Cut the address jumper  JA  on the printed circuit board     3  4  5  6  7  8  Cut the address jumper  J4  in the remote controller           JA  ADRESS    5  Thermistor A                         3  Connector 6P          3  Connector 5P                         4  Remove 1 screw     6  Side metal plate cover    2  Front metal plate cover    English    2     A    Sensor  securing                                               Remove  front grille    Open the front panel                                     J4  ADRESS  EXIST 1  CUT 2                   Indoor Unit Installation  1     Exposed installation    1  Refrigerant piping    1  Drill a hole  65mm in diameter  in the spot indicated by the   symbol in the illustration as below   2  The location of the hole is different depending on which side of the pipe is taken out    3  For piping  see 6  Connecting the refrigerant pipe  under Indoor Unit Installation  1     4     Allow space around the pipe for a easier indoor unit pipe connection     Left bottom piping 75     Unit   mm   Wall       45             vid     gt            Left back piping 75             tT  SA           
20. s and gas leak  checks in the installation manual for the outdoor  unit               Check for leakage here       Apply soapy water and  check carefully for leaking  gas       Wipe soapy water off after  the check is complete                                   8  Attaching the connection pipe       Attach the pipe after checking for gas leakage   described above  1    1  Cut the insulated portion of the on site piping   matching it up with the connecting portion     2  3     EA Refrigerant Ss Refrigerant ith Refrigerant  pipe pipe       2  Secure the slit on the refrigerant piping side ee  with the butt joint on the auxiliary piping using l   the tape  making sure there are no gaps        Insulation    sheet   3  Wrap the slit and the butt joint with the included     insulation sheet  making sure there are no  gaps           Tape                        Auxiliary pipe     N CAUTION    1  Insulate the joint of the pipes securely   Incomplete insulation may lead to water leakage   2  Push the pipe inside so it does not place undue force on the front grille     9  Connecting the drain hose    Insert the supplied O drain hose into the  socket of the drain pan    Fully insert the drain hose until it adheres to  a seal of the socket     Drain pan       N    Seal  Drain pan             Drain hose       Seal                            Drain hose    9 English    1 0 Wiring  CIEEMA   install as described in the installation manual supplied with the Multi outdoor unit          Front meta
21. the metal conduit  for the heat exchanger   XX J    1  Do not use tapped wires  stranded wires  extension cords  or starburst connections  as they may cause overheating  electrical  shock  or fire    2  Do not use locally purchased electrical parts inside the product   Do not branch the power for the drain pump  etc    from the terminal block   Doing so may cause electric shock or fire    3  Do not connect the power wire to the indoor unit  Doing so may cause electric shock or fire     11 When connecting to an HA system    1     Remove the electric box   See 3  How to set  the different addresses on page 4         HA connector   S21     Cut off the pins using a nipper    Wire as shown in the diagram and connect    gt    the connection cord to the S21 connector      BLS 7     Sensor  Attach the side metal plate cover and xx r T    thermistor sensor and return the electric box  to its previous state    Attach connectors 5P  6P  and 7P    Replace the front metal plate cover and the  sensor securing plate              Front metal plate cover    English 10       Indoor Unit Installation  2     Half concealed installation    Only items peculiar to this installation method are given here  See Exposed Installation for additional instructions     1  Wall hole      Drill a wall hole of the size shown in the illustration on the right  670 690  Unit  mm           Open size 7             Opening hole       585 595    Floor      Hs eee             2  Installation of supplemental plate for 
22. with the Operation Manual to ensure that all functions and parts   such as louver movement  are working properly     The air conditioner requires a small amount of power in its standby mode  If the system is not to be used for some  time after installation  shut off the circuit breaker to eliminate unnecessary power consumption   e If the circuit breaker trips to shut off the power to the air conditioner  the system will restore the original operation  mode when the circuit breaker is opened again        Trial Operation from Remote Controller          1  Press ON OFF button to turn on the system    2  Press TEMP  2 locations  and MODE at the same time    3  Press MODE button twice       7    will appear on the display to indicate that Trial Operation mode is selected     4  Trial run mode terminates in approx  30 minutes and switches into normal mode  To quit a trial operation  press ON OFF  button        Test items       Test Items Symptom Check       Indoor and outdoor units are installed properly on solid bases  Fall  vibration  noise       No refrigerant gas leaks     Incomplete cooling heating  function       Refrigerant gas and liquid pipes and indoor drain hose extension are  thermally insulated     Water leakage                               Draining line is properly installed  Water leakage  System is properly earthed  Electrical leakage  The specified wires are used for inter unit wiring connections  Inoperative or burn damage  Indoor or outdoor unit   s air intake 
    