CB Series MultiYfunction Counter / Timer User Manual
Contents
1. function selection save read menu setting data If LCK 4848 counter shows advanced fuction setting menu LCK 4848 ADDR BAUD S L POS EXIT measuring status Press gt to change value SAVE LOAD SAVE save the data to the appointed room LOAD load data from the appointed room select the position to save data pee eT MEM2 MEM3 exit menu pYES NO YES save or load data when exit NO not save or load data when exit functoin selection press RST clear all memory and exit use A select CNT TIM select counter or timer up down timing ing mode use A select U gt d U Counting Timing Up d Counting Timing Down Use A to select total 4 input modes Please refer to Picture A Input Mode Logic Chart A CP1 counts when it is high electrical level CP2 is invalid B CP1 counts down when CP2 is high level CP1 counts up when CP2 is low level Up mode 7 I input mode C CP1 counts up CP2 counts down display value CP1 CP2 Up mode rm selection D CP1 counts up when the phase of CP1 leads the one of CP2 CP1 counts down when the phase of CP1 lags the one of CP2 This mode is applicable to rotary encoders input it is not necessary to connect pull up resistors but only for NPN mode 8 counting speed press a to select different counting speed eee selection r ecne vane gt shift the flickering digit A change the flickering d
2. 0 Down Toff setting time Toff setting time 0 FLCKERI1 Power off to reset Hold output Se ee Power supply cp ID PAUSE Reset AL2 output up UP setting time Display 0 Down Down setting time 0 FLCKERI1 Power off to reset One shot output Power supply a cpi f ee PAUSE RaRo o Reset AL2 output up UP setting time Display 0 Down Down setting time 0 1 Timing starts when CP1 signal turns ON and resets if CP1 signal turns OFF 2 When reset signal is OFF CP1 signal is ON timing starts when power turns ON 3 Control output operated as hold or one shot time Power CP1 AL2 T preset time output 1 Timing starts when CP1 signal turns ON and continues when CP1 signal turns OFF 2 When reset signal is OFF CP1 signal is ON timing starts when power turns ON 3 Control output operated as hold or one shot time Power j m T preset time ee 1 Timing starts when power turns ON and continues when power turns OFF 2 When reset signal is OFF PAUSE signal is OFF timing starts when power turns ON 3 Control output operated as ho oMt Bhot time Power AL2 T preset tiem output 1 Timing starts when CP1 signal turns ON If CP1 signal is applied repeatedly only initial signal is recognized 2 When power turns ON and reset signal turns OFF timing starts when CP1 sig
3. state is 0 0 001 9999 down mode when measuring value falls to 0 AL1 outputs A digit display AL1 light turns on reset state is SV1 8 pay Setting value 1 key change fickering digital value 0 00001 999999 SVI SV1 lightison key shift digit 6 digit display SET key confirm all changed parameter if setting value is 0 0000001 99999999 0 press SET key will display Error or Erro can t exit 8 digit display RST key decimal point shift key Press it once the decimal point shifts rightwards by 1 digit up mode when measuring value raise to setting value SV2 AL2 SV1 gt P 9 au Setting value 2 outupts AL2 light turns on sv2 gt P SV2 light is on down mode measuring falls by setting value SV2 it becomes SV1 SV2 P gt 0 AL2 outputs AL2 light turns on SET RST setting same as above l up mode when measuring value raises to setting value BSV Batek seting BAO output BAO light turns on BSV BP 3 BSV value BSV gt light is on down mode when measuring value falls to setting value BSV BAO BP20 outputs BAO light turns on SET RST key setting same as above Chart A Input logic relation chart up down indication H H CPi LM O CPi L Ml Ml o H H CP2 L cP2 L _ n rr i Ino counting l4 L5 int A no counting aa nve n 3 fi A of n counting 0 n counting o value waliie CP2 not counting input CP1 counting input H CPI L Up mod
4. 30V Low 0 2V 19999999 99999999 8digit 199999 999999 6digit 1999 9999 4 digit 0000000 1 9999999 9S 8digit 00000 1 99999 9S 6digit 000 1 999 98 4 digit Dimension mm KKCB7E01 1 AC 250V 3A Resistive load Counting output mode F N C R K P Q A counting up or down 4 Panel Illustration CNT counter light TIM timer light BAT batch light z SV1 1 alarm setting light SV2 2 alarm setting light BSV batch setting light H hour M minute S second AL1 1 alarm light AL2 2 alarm light BAO batch alarm light Measuring value Setting value q gt e ae ew ow a CNT TIM BAT SVI SV2 BSV H M S ALT AL2 BAO Function Confirm key SD O O G Gu of tie Increase key Shift setting key reset key batch reset key 5 Key Operation 1 The counter should be checked if the connections are all correct before power on 2 There are 5 keys on the panel SET In normal status press SET for 3 seconds to show the setting menu A increase key In SV setting menu press it to increase the value in Setting menu press it to switch function RST Reset key In normal display status press it to reset the measured value in setting menu press it to shift the decimal point rigthward gt Shift key In normal display status press it to show SV setting menu In setting menu press it to shift the flickering digit rightward BRT Batch reset key In batch counting status press it to reset the ba
5. CB Series Multi function Counter Timer User Manual Feature saat Optional counting speed 1CPS 30CPS 1KCPS 10KCPS cores Prescale value can be set to 0 000000 99999999 8digit Power fail memory function 4 6 8 digit LED display for option Su uron are ov HWS 4 kinds of input modes and 8 kinds of output modes for counting Up to 3 relay output 9 kinds of timing modes Batch counting and output function one counter with two counting function For rotary encoder signal input no need to connect a pull up resistor Modbus RS485 communication optional function Applied to the field of light industry machinery packing and food industry to measure length and count signal input etc i TIL CB7 Series COUNTER TIMER a ee r e 72H X 72W X 100L mm 1 Code Illustration CBLILI R DOOL L Communication fuction blank no RS485 fuction 8 with RS485 fuction 1 1 preset 2 2 preset Display 8 8 digit 6 6 digit 4 4 digit Alarm C 2 alarm D 3 alarm Output R Relay S SSR Blank Switching power supply F 24VDC power supply Size mm 7 72W 72H 100L CB series multi functional Counter Timer 24V power supply can be special ordered 2 Ordering code No Code Size mm oa Display Outpt no Batch output Communication CB7 RC41 72x72 6 3 Techinical Secification Power supply Switching power AC DC 85 265V DC24V power to be special ordered Voltage Hight 3
6. F 3 2n 4 For u ee the setting time must be bigger than 100ms up UP setting time CP Display 0 AL2 ER De ER OnT Down Down setting time output 0 iia Setting time FLCKER2 Power OFF Hold One shot output 1 Timing starts when CP 1 signal turns ON if CP1 signal is recognized only is the initial one effective 2 Control output operated as One shot output it outputs when CPI the setting value is reached PAUSE AAR 3 When power turns ON and reset signal turns OFF timing Reset E EII starts when CP1 signal turns ON AL2 output o o oo y 4 For contact ontpit the setting tini the setting time must be bigger than 100ms OoOo Eo oe AFRI up UP setting time ie jn A Aee cA bt Power Display aR Fr s R a a a Down Down setting time x io ko henii RRR i pan output HOLD T D Timing sara wien CPT ia ON 2 Timing resets when CP1 signal turns OFF Power supply 3 When power turns ON and reset signal turns OFF timing CP l i Lt starts when CP1 signal turns ON PAUSE ie ts D 4 When timing value is reached display value and control Reset apip rie FLK output will be reset automatically z 5 During the timing process control output is ON a de Power AL2 output up UP setting time cp i
7. ction 1 Input logic No voltage input NPN 1 Solid state input 2 Contact input 1 p p Standard sensor NPN output type sensor Sensor Counter Timer Counter Timer 12V 5 4KQ Inner circuit circuit OV oV NPN voltage input CB counter CB counter Counting speed 1 or 30cps counter 2 Input logic Voltage input PNP 1 Solid state input 2 Contact input Standard sensor PNP output type sensor Sensor Counter Timer Counter Timer 12V 12V Inner circuit 5 4KQ OV Inner circuit 5 4K OV PNP voltage input CB counter CB counter Counting speed 1 or 30cps counter 9 Outlook and installation dimension 32 61 598 CB7 72 E m 61 5 98 E 4 i 10 Notice 1 In normal measuring status the timing value counting value and output will be reset if outer RST connectors are short connected or RST key is pressed manually 2 When the counter input mode is set to D mode it is for rotary encoder signal input there is no need to connect a pull up resistor only for NPN 3 After changing modes please press RST key to make value reset after that the counter timer can work accurately 4 If the counter timer displays Error or Erro message please check 1f the parameter SV1 SV2 and P is according to the logic relationship please refer to chart 2 5 Input signal The distance between a sen
8. e CP2 Low CP1 counts up CP2 high CP1 counts down Down mode CP2 low CP1 counts down CP2 high CP1 counts up counting 0 value Up mode CP1 counts up CP2 counts down display value CP1 CP2 Down mode CP1 counts down CP2 counts up display value CP2 CP1 counting 0 value Up mode CP1 leads CP2 counter counts up CP2 leads CP1 counter counts down Down mode CP1 leads CP2 counter counts down CP2 leads CP1 counter counts up KKCB7E01 4 Chart B Counter Output Mode Input Mode Counting up Timing up Counting down Timing down Action after the counting value reaches preset value Display value continues to increase or decrease output remains until reset signal input 999999 Display value and output na splay remains until reset signal PMY sve en 0 input AL2 ow W OOO AL1 Output ee E Display value is reset automatically output remains for the preset delay time and then is reset Output action is repeat single output Display value and output remains unitl preset delay time Output action is repeat single output Display value continues to increase or decrease until reset signal input Output remains preset delay time and then is reset Output action is repeat single output Output Mode A Display value remains the delay time of single output and then displays the next cycle va
9. eaS Down Down setting time oe OD AL2 0 output T Setting time INTERVSL1 Power OFF reset 1 eat and control output is ON when CP1 signal turns ON Power supply E 2 If CP1 signal is applied repeatedly only is the initial one recognized CPI n 3 When timing value is reached display value and control PAUSE 7 i 3 3 i output will be reset automatically Reset ol l o 4 When power turns ON and reset signal turns OFF timing AL2 output z m starts when CP1 signal turns ON ee ee ee 5 When CP1 signal maintains ON status the timing process is normal up _ _ UP setting ae Powe Display 7 Amdal aas F Down Down setting a Ve TE E oy CP1 AL2 output T Setting time 1 When power turns ON and reset signal turns OFF control output keeps ON status when CP1 signal is ON 2 When timing value is reached display value and control output will be reset automatically CP1 PAUSE _ 2 TEENI Reset fis iit Power S AL2 output a CP1 m up UP setting time r Hereni O Sarr Display 0 merce eee Down Down setting time xi CPF SN output 0 7 Connection Drawing PAUSE BATCH RESET gt AL2 RESET 12V GND CP2 85 265V AC DC Eua CP gt CB7 Please refer to the connection drawing on the product if any changes KKCB7E01 7 8 Input conne
10. igit value pa P Prescale value setting range 0 0000001 99999999 setting f f a Prescale function converting pulse input to the direct display of length position or flow value Ihaj display value E 10 g L ie decimal point use Ato choose different decimal point position JAL setting 11 lj La Trigger mode use A key to select rising edge or falling edge triggering voltage or non voltage input A choose different timing range S gt MS gt HM ad _ S 0 01s 9999 99s 12 k A timer range M S 0 01s 9999m59s selection H M 1m 9999h59m H M S 0 01h 99h 59m 59s 99 input control use A choose different timing range k gt 30 gt 100 1 aia 13 Inte signal pluse Pulse Width setting range 1 1000 unit ms width setting input signal width such as RESET BATCH RESE and PAUSE signal use A choose different output control mode m Counting Mode F NR C K P Q A See chart a Counter output mode 14 oli output mode Batch Counting Linespeed Output Mode F N R C please refer to chart B selection o ond ond ond2 FLK FLK1 FLK2 gt int gt intl ofd Timing Mode l see chart C Timer output mode ETI gt shift the flickering digit a ie A change the flickering digit value 15 ELE The delay time of RST change the delay time decimal point position out Z L output 1 2 Delay time seting range same as counter amp 5 H Min Delay Time 0 01Second _ The setting range is same as Coun
11. lue During the delay time the display value starts the counting of next cycle timing output action is repeat single output Display value continues to increase or decrease in the delay time of single output and is reset when delay time is up Output remains for delay time and then is reset Output action is repeat single output Min preset value amp AL2 output remains till manual reset signal input AL1 output remains for preset time and then is reset Output action is repeat single output KKCB7E01 5 Chart C Timer Output Mode One shot output Hold output t One shot output time Hold output Output mode Power supply __ PAUSE n oe Reset AL2 output up UP setting time Display 0 Down Down setting time CT g OND Power supply CP1 PAUSE Reset AL2 output up UP setting time Display 0 Down Down setting time 0 ond OND 1 Power supply n s Oo pe _ PAUSE TEE E Hm Reset Ae R AL2 output _ up UP setting time _ Display 0 Down Down setting time 0 FLCKER Power off to reset Power supply CP1 n C a a E PAUSE _ p Reset Cy a E OND 2 m Toff Ton Ta Tb Ton Toff Tor it r ee gt gt 5 Toff i Toff AL2 output Toff setting time up Toff setting tiem Display
12. nal turns ON 3 Control output operated as hold output when timing to Toff or Ton setting time output is ON or OFF no One shot output 4 Each single Ton time and Toff time must be set separately 5 For contact output the setting time must be bigger than 100ms 1 Timing starts when CP1 signal turns ON if CP1 signal is recognized only is the initial one effective 2 When power turns ON and reset signal turns OFF timing starts when CP1 signal turns ON 3 Control output operated as hold output For contact output the setting time must be bigger than 100ms Power T T T AL2 output T Setting time 1 Timing starts when CP1 signal turns ON if CP1 signal is recognized only is the initial one effective 2 When power turns ON and reset signal turns OFF timing starts when CP1 signal turns ON 3 Control output operated as One shot output For contact output the setting time must be bigger than 100ms Power CP1 A a ae ae at output T Setting time KKCB7E01 6 FLCKER2 Power OFF Hold Hold output 1 Timing starts when CP1 signal turns ON if CP1 signal is recognized only is the initial one effective Power supply M ee 2 Control output operated as Hold output maintained to the CPl nn i next setting value PAUSE B m 3 When power turns ON and reset signal turns OFF timing Reset z 2 2 3 starts when CP1 signal turns ON AL2 output a gt 2
13. sor and the counter should be as short as possible If the signal wire has to be extended please use shielding wire The signal wire should be apart from power supply wire 6 Counter input connection when in high speed mode 1K 5K 10K if the input mode is contact input such as relay connectors the counting value may be more than the actual one So for this input mode please set the input speed as a small value 1 or 30cps 7 The product should not be used in below environment heavy shaking and shocking place heavy acid and alkali place direct sun shine place strong magnetic field and electronic interference environment 8 Installation environment Only indoor below altitude 2000M pollution level is 2 The product may get malfunction if the operation is not followed to the above instruction KKCB7E01 8
14. tch value 3 In setting menu press SET key for 3S to quit the menu and return to normal display status If no button operation for long time in the setting menu it will automatically quit and return to normal display status but the data will not be saved 6 Operation Sequence Power on Normal display LCK 0010 to shield SET the next menus LCK value 4848 press set gt 3s to return to normal display status Counting up down Timing mode SET wW Communiction Add SET mes timer mode Press Ato select Counter mode _ SET a2 m Press A to select Communication an baud rate SET ISET W m second Ea save or read input mode menu data SET counting speed ae select voltage or E hs asad Bele oni caput sienal wail non voltage input position selection ISET E ISET nn SET 7 a pre scale GA imput signal width ga ut amp execute SEME 3 counter output mode not execute SET SET AEN decimal point me timer output mode setting outputl delay time T7 Series OOUNTER TIM i kot 1 i z 000 100 output2 delay time Ma batch pre scale ZAS power fail memory function selection SET menu circularly display press SET key for 3 seconds to quit the menu and return to normal display status CT Series COUNTER TIMER my Buce Sern timer output delay time SET KKCB7E01 2 Form1 parameter setting meaning specification
15. ting range selection YES with power fail memory After power on the counting timing is from the saved value after the 16 Ho L PONSI fail memory last power off function selection NO no power fail memory After power on all value will be reset gt key shift the flickering digit A key change the flickering digit The setting range of password 0000 9999 System locks or unlocks 4 different function as per the password value set by users 1 Lock or unlock SV value Only if LCK 0001 SV value cannot be changed Otherwise it can be changed iru 2 Lock or unlock RST BRT value Only if LCK 1000 RST amp BRT key is locked i e 17 LLE key lock value cannot be reset even RST or BRT is pressed Othewise RST amp BRT key has reset function But the connectors of RST amp BRT is not locked i e users can still reset value by connecting the connectors 3 Lock or unlock ex factory value Only if LCK 0100 users can reset all setting to ex factory value by pressing SET Akey for 3S in normal display status At this moment it shows INIT for 1S and then setting value is reset 4 Lock or unlock menu Only if LCK 0010 menu is locked and users cannot change menu value otherwise users can change menu value KKCB7E01 3 Form 2 SV Value setting parameter Parameter ena l No Code Name j Indication Setting range meaning up mode when measuring value raises to setting value SV1 AL 1 outputs AL1 light turns on reset
Download Pdf Manuals
Related Search
Related Contents
整出 「死亡や重傷を負うおそれが 登 繍主宰 「傷害を負うことや、財産の APart CONCEPT1 AV receiver Samsung SGH-C200 Kullanıcı Klavuzu Bosch PIA611B68B hob Bolero User Manual - SkidWeigh Technology Istruzioni per l`uso Elcometer 1001 DH-40i User`s Manual Manuel d’installation L`offre et les tarifs SFR La Carte Copyright © All rights reserved.