SYNC Software User Manual
Contents
1. Is Select Required CROB Command Type Gi CROB On Time 0 4294967295 msec CROB Off Time 0 4294967295 msec Analog Command Variation Description EasyConnect_Y4 0 0 Figure 17Modify Row Kalkitech External a 25 SYNC Software Field Level User Manual Version 1 0 0 For deleting added rows select rows from profile grid and click Delete Row on the right pane O Easyconnect File View Configuration Settings Diagnostics Tools Help Soa QRVvbopegO DEF 00 E Configuration 2 LO Devices 551 KSGLS6R1 Protocol Configuration Channel 1 DNP3 0 Serial Mas El Node_1 Profile 1 ei Settings ee Diagnostics CEJ NetworkDesign Channel 1 DNP3 0 Serial Master Mode Basic Type Object Type Digital Input Binary Inputs Digital Input Binary Inputs Starting Point Index Deadband Is Select 0 2147483648 Required Show Master Nodes Figure 18 Delete Row Adding large number of points in a profile using Easy Connect Add Row button can be time consuming Easy Connect Configuration Utility provides facility to export profile rows to an excel worksheet and import the points form an excel worksheet to the profile rows User can configure the required points in an excel worksheet and it can be imported to the required profile After adding required rows in the profile select Excel Export fr
2. 551 KSGLSER1 a R i CROB 3 Protocol Configuration pasele EE es ES Pons 02147483546 Ge Sch E d Channel DNP3 0 Serial Mas Digital Input Binary Inputs 65535 1 E Node_1 Hg Settings Add Points ee Diagnostics Export Profile By NetwokDesion Add Row Modify Row Delete Row EI CI Show Master Nodes Figure 22 Delete Profile Kalkitech External 29 SYNC Software Field Level User Manual 3 2 Add Slave Channel To add a slave channel and node follow the procedures mentioned above 3 3 Add Master to Slave Map Version 1 0 0 To add a Map select the required Row and the desired slave node then click on Add Map P EasyConnect O Node_2 Node_3 7 Node_4 Eg Settings ee Diagnostics E NetworkDesign E 4 Channel 2 DNP3 0 Serial Slav E 4 Channel 3 DNP TCP Slave Digital Input zl Binary Inputs Add Row Modify Row Delete Row Channel 2 DNP3 0 Serial Slave Node 2 Channel 3 DNP TCP Slave_Node_3 Channel 3 DNP TCP Slave Mode 4 File View Configuration Settings Diagnostics Tools Help Scud APAPFEGPEO Fer eu e Configuration Channel 1 DNP3 0 Serial Master_Node_1 x o LC Devices gt 551 KSGLSERI E Starting Point Number Of Deadband ls Select SE 5 Protocol Configuration Basic Type Object Type Index Points 0 2147483648 Required oo S d Channel DNP3 0 Serial Mas niga input Binary Inputs
3. Add Map Modify Map Delete Map rr Figure 27 Auto map selected profile points Kalkitech External 33 SYNC Software Field Level User Manual Version 1 0 0 2 Step 2 or 3 will pop up the Auto Map window as shown in the figure below User can configure the details in the Auto map window and generate auto mapping Source Node Destination Node lt EETAS y Source Protocol Mapping Details Source Types Single Indications Double Indications Analog Inputs BitString 2Byte Destination Types Double Indications Double Indications Measured Value F Double Indications Destination Protocol Destination Start ddress Information Object Address Figure 28 Auto map window 3 3 1 1 Auto Map Window Auto Map window shows the master source types that are considered for automatic mapping corresponding slave types automatically considered as mapping type user can change using combo options and corresponding start address in the slave The parameter details of Auto Map window are given in table SI No Parameter Details 1 Source Node Indicates the node number whose profile needs to be mapped This parameter is not editable Indicates the node to which the mapping needs to be done The default will be the node selected in the mapping window User will able to change the same to any other nodes which is available in the configuration system Protocol o
4. C Update Package C Dialup settings VPN settings Figure 42 Delete converter VPN If necessary repeat for each converter configured for the VPN network in the project The SYNC gateways configured in the VPN network becomes part of a private encrypted network Access to the network is restricted Under normal circumstances access to the VPN network from the workstation in which EasyConnect is installed is not necessary So the steps mentioned below are not necessary for normal operation To access gateways that are part of a VPN network requires certain system setup procedures to be completed To make EasyConnect a part of the VPN network install OpenVPN on the workstation in which EasyConnect is installed Now right click on the VPN node to get the Export EC cert files link as shown below Click on the link and save the files Use these files to connect to the VPN network Refer to the OpenVPN documentation for information Kalkitech External 48 SYNC Software Field Level User Manual Version 1 0 0 File view Configuration Settings Diagnostics Tools Help Md APGA SEGPEO Cer 00 E 4 Configuration Device Ly Devices E 4 551 KSGLS156R4 5 Protocol Configuration A Settings gt 552 KSGLS6R1 5 Protocol Configuration A Settings 4 553 KSGLS16R2 5 Protocol Configuration mA Settings vi NetworkDesign 551 KSGLS16R4 Client 553 KSGLS16R2 Client 110 8 0 9 m Vo Downlo
5. D a El 552 KSGLS6R1 E Protocol Configuration 4 Channek1 037118 Master Eg Settings E Protocol Configuration Eg Settings Add VPN Figure 35 Add VPN File View Configuration Settings Diagnostics Tools Help B d 10909 E0P gt 50 FEF eu 5 M Devices E 551 KSGLS6A1 2 Click on Add VPN link A new dialog box will appear as in figure below Refer VPN Pop Up Details table for parameter details Generate Certificates Country code State Province City Organization Email ID IN Kamataka Bangalore Kalkitech support kalkitech com Figure 36 VPN Pop Up Cancel Kalkitech External 43 SYNC Software Field Level User Manual Version 1 0 0 Country Code AU BH BR CA CN IN A drop down menu IN JP PK US gives an option to set various country codes Select the required country code State Province Karnataka This field is for entering the state City Bangalore This field is for entering the city location Organization Kalkitech This field is for entering the name of the organization E mail ID support kalkitech com This field is for entering the e mail ID Table 10 VPN Pop Up Details These are used for certificate generation purposes only and has no other function 7 Contig VPN Network address 10 8 0 0 Server Device Sei KSGLS16R4 Sub
6. Refer Dialup parameters table for its parameter name and its description File View Configuration Settings Diagnostics Tools Help Buden BorseO GBH 0900 E Configuration Port Comi Sp Ces Ces Baud Rate 115200 ER at E Protocol Configuration Sie Type Baa 4 Channel C37118 Master Data Bits 8 EA Settings Stop Bits 1 o Lan Settings Parity None a Flow Control Hardware o 52 KSGLS6R1 EE _ Full Duplex Protocol Configuration Link Type GPRS Hg Settings Service Number gg q NetworkDesign APN Name Logo Figure 30 Add DialUp Ka lkitech External 38 SYNC Software Field Level User Manual Version 1 0 0 Port Com1 Com16 Com Gives the valid com port to which the modem will be connected Baud Rate 200 600 1200 2400 115200 To set the baud rate 4800 9600 19200 according to the modem 38400 57600 115200 baud rate Channel Type NA RS 232 Not Editable Type of channel used Data Bits NA 8 Not Editable Number of data bits Stop Bits NA 1 Not Editable Number of stop bits Parity NA None Not Editable Number of parity bits Flow Control NA Hardware Not Editable To prevent overflow of modem buffer Channel Mode NA Full Duplex Not Editable Link Type NA GPRS Specifies the link type to be used Service Number 99H 99 1 99 1 Universal dialing Number for the given link type APN Name Depends upon service www Access Point Name for prov
7. right click the channel will create the client and server nodes automatically by reading the ICCP Configuration file Download the configured file to SYNC K lt alkitech External 72 SYNC Software Field Level User Manual Version 1 0 0 Appendix B Flag conversion in SYNC When a protocol conversion is achieved using SYNC the quality flag conversion between the protocols has to be defined The table below is used to explain the quality flag translation between protocols inside SYNC The flags received in any of the SYNC Master Protocol SYNC Master will be translated to the specific flag of SYNC Slave Protocol SYNC Slave as in the table given below Ka lkitecha External 73 Version 1 0 0 User Manual SYNC Software Field Level IAR yO mo AIRND IRI 90 3 PITA AU DIE TUNA Arn IRI 90 3 bp AU DIE AIPND IRI 30 5 PIMA AH DIE WW tT tT tT CU ICC Ao i SE wgl LL melen weng HE E CCAA LL LL WII IS PS FS II PS IEA A LL LI EE 1 better EJ EE EERE WT Iw ze AN 1009 01d MUPIS 100 H a gt a aan pa Ba SMA oud AMONE ION ai sp TAREN KA K l Gen ug 74 External Kalkitech SYNC Software Field Level User Manual Version 1 0 0 All fags described in the table are considered to be set and the following translation is applicable unless specified otherwise 1 See quality description details in section 7 2 6 3 and 7 2 6 4 of IEC 60870 5 101 2 See DNP V3 00 Data Object Library FLAG d
8. 168 100 80 2 Configuration File E rom the co License File C Update Package l C Dialup settings C VPN settings C SNMP settings Kal lkitech External Figure 49 Download Configuration File 55 SYNC Software Field Level User Manual Version 1 0 0 5 Redundancy Support This part of the document describes the implementation of redundancy using SYNC series of protocol gateways 5 1 Introduction KALKI Substation Gatewaylite offers several options to create redundant solutions This section outlines the redundant options one by one The usage will be described with diagrams and at the end use cases will be presented to show how combinations of redundant options can be used to create reliable communication systems The redundancy mechanism consists of a hot gateway and a warm gateway The hot gateway is polling the devices and communicates with the control center as it was a stand alone system The hot and warm gateways are communicating with each other through an integrated link Integrated link options supported by SYNC gateways include Serial TCP Serial TCP and Dual TCP links Out of these integrated link mechanisms the latter two provide a redundancy for the integrated link also 5 2 Types of Switchover SYNC gateways supports the following types of switchover 5 2 1 External Trigger Switchover External Trigger 4 Warm Warm Hot Figure 50 Switchover d
9. 65535 1 Node_1 Profile Digital Input Binary Inputs 1 1 Show Master Nodes 5 Add Map Modify Map Delete Map Figure 23 Add Map Note To Enable Master to Master mapping select Show Master Nodes Master to Master mapping is used when input data from an external device is translated to a command output and sent to an external device Kalkitech External 30 SYNC Software Field Level User Manual Version 1 0 0 To modify a mapped row select a row from the destination unit and click on Modify button A new window will open with added mapped values Edit the parameter values Click on Save to update the modified mapped point Refer the figure below File View Configuration Settings Diagnostics Tools Help Pd oe 8 orp eO FEF 00 E 4 Configuration F Channel DNP3 0 Serial Master_Node_1 live Ey Devices D CROB Deadband Is Select 0 2147483648 Required ee Dbject Type Binary Inputs Starting Address 1 Number of Points 1 Event Class 1 Static Default Variation 1 Change Event Default Variation 1 Comments C Show Master Nodes Channel 2 DNP3 0 Serial Slave_Node_2 Starting Number of Static Basic Type Object Type Address Ports Event Class Variatit Figure 24 Modify Map To delete a mapped row or group of rows from the conversion select mapped row from the destination unit and click D
10. Address redundant TCP link of A B C IP address other gateway for Dual Ethernet link 14 Port Number Port number used for Any valid port Recommended accepting incoming TCP number value is 3000 connections on Main gateway Ka lkitecha External SYNC Software Field Level Channel Retry Response Timeout Offline Poll Period User Manual Number of times an HSB An integral value link packet is resend in case of failure to get an ack Response timeout in milliseconds for HSB messages with acknowledgment Time interval in seconds in which a non communicating gateway is probed to check whether it is alive or not Version 1 0 0 Default value 2 Recommended to be kept as multiples of 1000 Table 14 Channel configuration parameters for achieving redundancy 5 5 3 Node Configuration After the configuration of an HSB channel we need to add a node under that The following window will be shown when the user clicks on Node_1 This corresponds to the node parameters of HSB Master FasyConnect File View Configuration Settings Diagnostics Help B da 74 O8Borpaseego 8 Di Configuration HSB Type 4 KSGLSER1 Se Channel HSB Master RET I IPE D IP Switching Hot IP Address Warm IP Address Alias IP Address Network IP Heartbeat Interval secs Maximum Heartbeat Failure Diagnostic Point Event Status Change Event Settings A Main
11. SR Devices Destination Address 4 PR Link Status H t Interval 0 4294966 5 a 884 Protocol Configuration eae sec Enable Time Synchronization True Channel DNP3 0 Serial Mas De End of Init AA Settings val 0 4294966 sec 60 ee Diagnostics Import Profile E False Eq NetworkDesign X Delete i True Integrity Poll Type End of Init Figure 12 Add Profile Profiles can be saved for reusing the same address configuration for different masters Right click a Profile tree node and select Export Profile a Save File window will pop up Save the profile in desired name in desired location File View Configuration Settings Diagnostics Tools Help Bed oe blog eco oO amp Configuration z Chanel DNP3 0 Serial Master_Node_1 x EL Devices e 551 KSGLSER1 y Starting Point Number Of Deadband Is Select 8 Protocol Configuration Pa Object Type Index Points 0 2147483648 Required Si Channekl DNP3 0 Serial Mas Digital Input Binary Inputs 65535 1 GG Node_1 Ha Settings Add Points E NetworkDesign K Delete II l Add Row Modify Row Delete Row x CI Show Master Nodes Figure 13 Export Profile Instead of adding a new profile you can also import previously saved profile data Right click on a master station and select Import Profile option an Open File window will pop up Open a saved profile file Refer figure below Kalkitech External 23 SYNC Software Field Level U
12. Self Alias Sharing 0 0 0 0 1111 0 0 0 0 eth 5 2 Disable Disable Figure 56 Node configuration for achieving redundancy The following tables describes each of the configurable options inside the Node parameters Kalkitech External 62 SYNC Software Field Level User Manual Version 1 0 0 HSB Type Used to determine Main Standby One gateway should be whether the gateway is main and other gateway main or standby should be standby always Failure to do the same will result in redundancy not working properly Switchover Switchover type for the External Type gateway triggered Self Used to configure the IP None switching mechanism for Swapping the gateways Alias Sharing IP address of the hot Any valid gateway The IP would be class A B C IP applied to the Network address interface specified below IP address of the warm Address gateway The IP would be applied to the Network interface specified below Alias IP IP address of the alias Address interface on gateway The alias interface would be made on the Network interface specified below Network IP Used to select the EthO Eth1 interface to which the IP switching mechanisms are applied Heartbeat Time interval in seconds An integer The switchover time in Interval in which each gateway value case of an integrated link sends a keep alive failure is determined by message to other one Heartbeat Interval Maximum Heartbeat Failur
13. choose the option Add Station In the General tab of node parameters select Authentication Scheme type user name password and type the Connection Timeout In Scheduled Transfer tab add a schedule by specifying the time period for the scheduled transfer to run You can add as many schedules as required Schedule Name Schedule2 Scheduling Mode Weekly Day of Week Tuesday Dau of Month Time 10 12 0 Schedule Multiplier 1 65535 1 Figure 59 Add schedule e Now click on the schedule under which you want to add a transfer task Add a new transfer by specifying the transfer details Kal lkitech External 67 SYNC Software Field Level User Manual Version 1 0 0 Transter Type Upload Mode Folder Remote OS Source Subfolder Ahomedite ouv FTO Source File Destination Subfolder home ser Destination File File Extension Fie Tipe ASCII Transfer Timeout 1 65535 Sec 100 8 Maximum Retries 1 Transfer Based on File Modification Time Disable Keep Temporary File Disable Folder Size Limiting Disable Rollover Limit 1000 Figure 60 Add Transfer Task 7 2 Configuring File Transfer Slave Channel Steps for configuring file transfer slave are as follows e Choose File Transfer Slave from Add Channel menu in Protocol Configuration Select Protocol Supported type Listen Port and Inactivity Time Period in the corresponding fields Now right click o
14. gateway model in the left pane of the application choose gateway model from sub menu of Modify Gateway lt EasyConnect fd Settings NetworkDesign Figure 6 Modify Device Ars tICescn External 20 SYNC Software Field Level User Manual Version 1 0 0 To delete the selected gateway right click the selected gateway and choose Delete a a Configuration Device Name Ey Devices a j AA Settings Ey NetworkDesign ords Stored Figure 7 Delete Gateway 2 Add Master channels to the converter model as shown in figure below Me EasyConnect E A Configuration 4h Devices E 4 551 KSGLS6R1 epp mn d Setti ee Diag Bj NetworkDesiat Figure 8 Add Master Protocol Kalkitech External 21 SYNC Software Field Level User Manual Version 1 0 0 You can delete a protocol specific communication channel by selecting Delete option from menu on right clicking on the selected channel as shown below File View Configuration Settings Diagnostics E A Configuration Tools Help BG oetes ops DEF OG Port L Coml g i Devices Channel Type R5232 E 4 551 KSGLS6R1 GE J bes Y Protocol Configuration e uplex A Channel eiii Raud Bate fio bits ond 3800 AA Settings Add Station 8 ee Diagnostics Add RChannel F 24 NetworkDesign Flow Control None CTS Delay 0 65535 msec 15000 Figure 9 Del
15. 0 January 2010 Table 1 Document Details Created By Tomy Modified By First Version Reviewed By Midhin Victoria Version Number 1 0 0 Project Name SYNC Software UserManual Field Level SYNC1000 2000 3000 Ka lkitecha Table 2 Document Authoring Details External SYNC Software Field Level User Manual Version 1 0 0 About the Document Purpose This manual serves as a guide for using Kalkitech SYNC protocol gateway models including SYNC2000 S6R1 SYNC3000 S4R2 SYNC3000 S12R6 SYNC3000 S8R2 SYNC3000 S16R2 SYNC3000 S16R4 SYNC3000 S16R4I and SYNC3000 S16F2 This manual describes the configuration details of SYNC models and installation of the configuration tool Easy Connect It contains information on using all aspects of the software support features including redundancy NERC CIP and VPN Please note that separate user manuals are available for each protocol which explains the detailed configuration and mapping Intended Audience This user manual is intended for the Kalkitech SYNC protocol gateway users Introduces you to SYNC and EasyConnect Familiarizes you with the user interface Gives you step by step instructions to install and get started with SYNC and EasyConnect Gives you step by step instructions to configure and map protocols present inside SYNC and EasyConnect Ka lkitecha External 5 SYNC Software Field Level User Manual Version 1 0 0 Organization of the Document This document
16. 0 S16R4 gateways provide NERC CIP standard compliance as an optional purchase In gateways having NERC CIP compliance only the ports and services essential for normal and emergency operations of the device are enabled by default Event logging is provided in gateways for all user actions through EasyConnect and web server These logs are kept for at least 90 days Older logs will be automatically erased from the device Users can retrieve this log using EasyConnect Retrieving Gateway Access Log The gateway access log can be retrieved for a selected period Steps to upload the log are as follows Choose Gateway Access Log from Diagnostics menu A pop up window named Gateway Access Log appears Gateway Access Log Device Name Other Device IP Address Use LAN IP Start Date Thursday 14 End Date Thursday 14 Save To C Documents and Settings user Desktop KSGL_lo EJ Figure 57 Retrieve Gateway Log el KSGL_M el 192 168 100 La January 2010 January 2010 ei Choose the device name model and type the IP address of the device in the corresponding fields Choose the start date and end date between which you want to take the log s Type the file name to save the log and click the button Get Log Now the Log will be saved to your PC and it will show a message that the log is successfully saved Gateway Access Log D 1 Successfully saved the CIP log fileKSGL_log txt F
17. 1518 Port number 3000 Channel Retry 2 Response timme out milli secs 1000 Offline Poll Period secs 10 A Settings D o Y Download Upload Figure 55 Channel configuration for achieving redundancy Kalkitech External 60 SYNC Software Field Level User Manual Version 1 0 0 The following tables describes each of the configurable options inside the Channel parameters 1 Channel State Used to enable or Enable Disable Should be disable the channel configured as Enable 2 Physical Link Used to configure the Serial TCP IP Dual Serial mode is type of link used for Dual Dual currently not integrated link Ethernet Dual supported Serial 3 Serial Type Serial port type RS232 RS485 RS422 4 Serial Mode Mode in which the serial Full Duplex Half port communicates Duplex 5 COM Port Name of the port through COM1 COM10 Name which serial communication happens Redundant Name of the port which COM1 COM10 Should have a COM Port provides a redundant link different value from Name to 5 5 Baud Rate Serial communication An integral value Should be kept one parameter should be of the following provided as baud recommended rate values 9600 19200 38400 115200 Pee Odd Even None ica Control A Software Hardware 12 IP Address IP address of the other Any valid class gateway for TCP A B C IP address IP Dual Dual Ethernet links Redundant ID IP address of the Any valid class
18. 15200 S1 KSGLS6R1 i 5 Protocol Configuration Channel Type RS232 Gd Settings Data Bits 8 Se 4 Lan Settings Stop Bits 1 2 Serial Ports Parity y Ce e x Hardware ia NetworkDesign annel mode Full Duplex Link Type GPRS Service Number SEI APN Name wu Figure 32 Delete Dialup Kalkitech External 40 SYNC Software Field Level User Manual Version 1 0 0 To delete the dialup settings from the converter delete the dialup settings from the configuration window as explained above Then check the option Dialup settings box in the Download command window as shown below and click on Download Download Device Name 551 IP Address Use LAN IP C Configuration File F ram C License File C Update Package Dialup settings C VPN settings Figure 33 Delete converter dialup Kalkite ch External 41 SYNC Software Field Level User Manual Version 1 0 0 3 6 VPN Support SYNC2000 S6R1 series have option of loading GPRS EDGE units needs to be ordered separately which allows the users to extend the Ethernet over wireless networks This allows users to connect and integrate the gateways to remote locations without any distance limitations Kalkitech M2M gateways can be used with the SYNC2000 S6R1 series to enable secure communication and data transfer via public networks using a virtual private network formed by the SYNC gateways Virtual Private Network VPN prov
19. 2 Table 7 Hardware Reourements tettetett EEEE EEEE EEEEEEEEEEEEE Ennan nen E EE EEn nenn EEEn 12 Table 8 Document Revision History 34 Table H Dialup Parameters 2 coron netas naaa SNE EE ARENS 39 Table 10 VPN Pop Up DetallS ccoo nasales ira aaa ido NN RSR EEN 44 Table 11 VPN ele LEE 45 Table 12 SNMP Parameters coiocoriocicon iii in il 51 Table 13 SNMP User barameiers ntete ennnnnneeer enn neeet 52 Table 14 Channel configuration parameters for achieving reduNndanoYy cooooooccccccinococcccnnncnoncncncnnnnnnns 62 Table 15 Node ParametersProfile Confouraton 64 Table 16 Profile configuration details for redundancy sssessseesssesserrrssesiirrtssettirtttstttttrrrttrtretereeeene 64 Table 17 Redundancy switchover details 65 Ka lkitecha External 11 SYNC Software Field Level User Manual Version 1 0 0 1 SYNC Field Level 1000 2000 3000 This document gives a comprehensive information on our SYNC field level products pertaining to the software installation and its configuration Please note for hardware installation and mounting please refer to the Hardware Installation Guide file found in the CD 1 1 Overview of SYNC Kalkitech SYNC is the family Hardware protocol in a box solutions that provide any to any protocol conversions delivered as a single software solution SYNC products are available in a range of substation hardened hardware configurations to suit every requirement from a simple 1 modem channel and lim
20. 785 Lontiguration Ey Devices E 4 551 SYNC2000S6R1 2 3 Protocol Configuration 4 Channel 1 IEC 104 Master E a Settings A Lan Settings Serial Ports System Name System Description System Location System Contact Read Write Access Community String Read Only Access Community String Securily Level noduthNoPriv Figure 48 Delete SNMP Configuration 2 Check the SNMP settings box in the Download command window and click Download Note Restart is required after downloading the settings for the changes to take effect Kal lkitech External 54 SYNC Software Field Level User Manual 4 Downloading Configuration File Version 1 0 0 You have to download the configured file to SYNC after creation or editing In case of editing you have to stop and start the firmware for the changes to take effect To download the configured and mapped file perform the following steps 1 On the user interface click Download The EasyConnect Download window appears 2 Click Download The file is downloaded to the SYNC and a corresponding success message is displayed File View Configuration Settings Diagnostics Tools Help Mid vosaQ e Bors O CHFA oo a 4 Configuration Lo LC Devices o S1 syNc2000seR1 E a 4 Protocol Configuratio Channel 1 Modb 4 Channel 2 DNP 4 Settings Device Name Device Name 551 Ey NetworkDesign IP Address Use LAN IP 192
21. C Software Field Level User Manual Version 1 0 0 Appendix A Special Case Configuring PPP IEC 61850 Server and ICCP peer PPP is supported on our converters but the customer has to specify separately in the order The PPP configuration files are provided separately which can be downloaded after modification into the converter at the specified locations Configuration of IEC61850 Server in EasyConnect has got some variation from configuration of other channels The following procedure has to be done for the same 1 2 6 Add IEC61850 server channel in EasyConnect The ICD file is created using SCL Manager and is saved in a file location You can select the configured ICD file from EasyConnect and add it to the profile Generate MMS tags for mapping Add stations and channels as described in the document Download the configured file to SYNC Configuration of ICCP Peer in EasyConnect has also got some variation from configuration of other channels The following procedure has to be done for the same 1 2 Add ICCP Peer channel in EasyConnect To configure ICCP right click and select Configure ICCP Utility The ICCP configuration file with local control center and remote control center with its association and bilateral table information is created using CCP Configuration utility and is saved in a file location You can select the configured iccp file from EasyConnect and add it to the profile To generate Nodes
22. SYNC Software User Manual Field Level SYNC1000 2000 3000 Version 1 0 0 December 2010 Kalki Communication Technologies Limited SYNC Software Field Level User Manual Version 1 0 0 SYNC Software User Manual Field Level SYNC1000 2000 3000 Version 1 0 0 December 2010 Kalki Communication Technologies Limited Anantha Pushpa Building 147 5 Main road HSR lay Out 7 sector Bangalore 560 102 India Ph 91 80 40527900 Web Site www kalkitech com K lt alkitech External 2 SYNC Software Field Level User Manual Kal lkitecha Disclaimer Copyright O 2010 KALKITECH 2010 Kalki Communication Technologies assumes no responsibility for any inaccuracies that may be contained in this document Kalki Communication Technologies makes no commitment to update or keep current the information contained in this manual Kalki Communication Technologies reserves the right to make improvements to this document and or product at any time and without notice Note KSGL model names are changed to SYNC from revision 2 16 0 of GPC protocol conversion engine The details of old model name and corresponding change are listed in table under Appendix C External Version 1 0 0 SYNC Software Field Level User Manual Document Release Note The details of the document is given as follows Version 1 0 0 Document 1 0 0 Release Number Document Release Date 3
23. SYNC Software Field Level User Manual File View Configuration WC wi sagat Settings Diagnostics Tools Help o E SCH amp 4 Configuration 4g Devices CH B A Node_1 E 4 Channel 2 Node E vii Settings Ey NetworkDesign lt 551 SYNC300054R2 Gi By Protocol Configuration E 4 Channel 1 Courier Master Row Number Row Row2 Basic Type Object Type Digital Input Single Indications Digital Input Single Indications Al Input Double Indications d Input Single Indications bg Input Analog Inputs bg Input Analog Inputs R orgral Input Analog Inputs lt AddRow Jl ModifyRow Delete Channel 2 IEC 104 Slave_Node_2 Figure 26 Auto map entire profile points Version 1 0 0 1 For mapping the selected rows in a profile select the needed rows in the profile for which the automatic mapping needs to be done Click on Auto Map slave destination mapping part as shown in the figure below Channel 1 IEC 101 Master_Node_1 Row Number Basic Type Digital Input y Information N P umber of oints id Is Select Deadban ES 0 2147483648 Required Object Address Single Indications Rows Digital Input Single Indications 5 6 Row Digital Input Double Indications 5 6 lt AddRow 11 ModifyRow DeleteRow Channel 2 IEC 104 Slave_Node_2 Show Master Nodes y
24. able parameters The parameters are explained below P EasyConnect alid_EC_Config ece QAQASEGPRO DZ eet SystemNams 25150 2 Tes ss System Deseption Protocol Gateway de 51 SYNC2000Sq System Description Protocol Gateway 33 Protocol Config kalkitech System Contact support kalkitech com G x d SR Settings User Security Level noduthNoPriv Authentication Protocol bi Authentication Password Privacy Protocol Privacy Password IAS ES E Add User gt Modify User Delete User Figure 46 Add user Ka lkitecha External 51 man py yin SYNC Software Field Level User Manual The parameters in the user window are explained below Version 1 0 0 Parameter Name Range Optional Values Default Value Description User Name sync This is the textual description of the person responsible for the SNMP entity that is to be managed Access read only read write read only Specifies access level applicable for the user Security Level noAuthNopriv authNopriv authpriv noAuthNopriv Specifies the security level applicable for the user added NoAuthNoPriv means no authentication and no privacy authNoPriv means authentication and no privacy authPriv means authentication and privacy Authentication Protocol MD5 SHA MD5 The protocol used for authentication Note Applicable only when selected Security Leve
25. ad Edit Export EC Cert files MK Delete Figure 43 Export VPN certificates The set of Easy Connect certificates can be used to configure only one instance of OpenVPN client at a time Also make sure that the Easy Connect workstation and the protocol gateway are time synchronized Once Easy Connect is a part of the VPN network we can get the ping status of the converters in VPN mode using the Get Device Status button as shown below 23 Protocol Configuration Bd Settings Lan Settings 2 Serial Ports 5 VPNSettings NetworkDesign dio VPN Edit VPN Time out ms 1 Do _ sl Get Device Status rect Y4 0 0 Figure 44 VPN Diagnostics Kalkitech External 49 SYNC Software Field Level User Manual 3 7 SNMP Support Version 1 0 0 Simple Network Management Protocol SNMP is a UDP based network protocol It helps to manage network attached devices and make sure they are not only up and running but also performing optimally SNMP exposes management data in the form of variables on the managed systems which describe the system configuration These variables can then be queried or set by managing applications SYNC specific objects managed by SNMP are Model Name Hardware Informations such as Ethernet Interfaces Details Serial Port Details Memory Usage etc and Software Informations such as GPC health DCCP health etc 3 7 1 ADD SNMP Details To configure SNMP settings for a gat
26. al 46 SYNC Software Field Level User Manual Version 1 0 0 The following Config VPN window will pop up Make the required changes and click Save button at the bottom of the window Config VPN Network address 10 8 0 0 Server Device S51 KSGLS16R4 Subnet mask 255 255 255 0 Server LAN WAN IP 192 168 0 Port 1194 Server VPN IP salt Al Nore Select Device VPN IP _ PN Mode EI 551 KSGLS16R4 10 8 01 Server Y 853 KSGLS16R2 1108 09 Client Figure 40 Edit VPN Pop Up To delete the VPN settings from the configuration window right click on the VPN node to get the Delete link and then click the Delete button File View Configuration Settings Diagnostics Tools Help CG vae QvboreO FEF 00 a 4 Configuration Device E Ly Devices o 551 KSGLSER1 5 Protocol Configuration EA Settings co Lan Settings Serial Ports Ey VPNSettings 552 KSGLSER1 Y Protocol Configuration mu A Settings NetworkDesign V Download Edit Export EC Cert files MM Delete Figure 41 Delete VPN Kalkitech External 47 SYNC Software Field Level User Manual Version 1 0 0 To delete the VPN settings from the converter delete the VPN settings from the configuration window as explained above Then check the VPN settings box in the Download command window as shown below and click Download Device Name 551 IP Address Use LAN IP C Configuration File C License File
27. ateway A Warm Gateway B Hot B Figure 54 Redundant configuration with No IP Switching In this configuration each gateway has it s own private IP address only This will require special network configuration on the part of the control center The control center needs to detect the hot gateway and it should ensure that the correct gateway is being connected after a switchover Kalkit ech External 58 SYNC Software Field Level User Manual Version 1 0 0 5 3 5 4 5 5 Redundancy Requirements One of the gateways should be configured to have the higher priority This will make the gateway with the higher priority hot when a There are no error conditions b Both the gateways have the same channel healthiness In all other cases the hot gateway is determined based on the healthiness of each gateways Basic switchover condition is when the hot gateway has a hardware software failure All serial links are made through Y cables It is possible to force a switchover Both gateways should have the same hardware configuration And also Software configuration should be the same with minor changes in configuration file It is mandatory to have a dedicated link between the two gateways involved in redundant configuration Also it is preferable to select an Ethernet link as the dedicated link between two gateways because of the speed offered by the medium Gateway Redundancy Information and Control When SYNC are place
28. cation window appears 3 Click Next The Setup Complete window appears K lt alkitech External Please contact 14 SYNC Software Field Level User Manual Version 1 0 0 2 2 Removing EasyConnect You can remove all the installed contents of EasyConnect from your system To remove EasyConnect perform the following steps 1 From Start menu choose Settings the corresponding window will get displayed Choose Control Panel from the window the Control Panel window get displayed Select Add or Remove program 2 From the program list in the Add or Remove Programs window choose EasyConnect 3 Click Change Remove The Confirm File Deletion window appears 4 On the Confirm File Deletion window click Yes The uninstall shield wizard removes all components from your system 5 On the uninstall shield wizard Click OK 2 3 Starting EasyConnect EasyConnect helps you to configure files You have to download the configured file to the SYNC before running it To access EasyConnect as a first step you have to start the EasyConnect To start EasyConnect perform the following steps 1 From Start menu choose Programs the corresponding window will get displayed Choose Kalkitech the corresponding window will get displayed Choose EasyConnect The EasyConnect user interface appears Ele ven Configuration Settings Diagnostics Tools Help Md v1pAP EE BO FEF 00 EasyConnect KALKITECH Eas
29. d in redundant configuration status information is added to the device database This information can be accessed by the control center The following indications are supported by the gateways Gateway ID this indication gives the Gateway ID of the connected gateway This shows whether the gateway is configured as main or standby Gateway Status this indication gives the Gateway Status of the connected gateway This shows whether the gateway is currently working as hot or standby IL Communication Status this indication shows the current communication status of the integrated link It shows whether the remote gateway is communicating via the integrated link Gateway Healthiness this indication shows the healthiness information of different channels of the gateway Remote status indication this indication gives the Gateway Status of the remote gateway This shows whether the remote gateway is currently working as hot or standby This information is only valid if the IL communication status indicates that the gateway is on line Apart from this the SYNC protocol gateway with redundancy support has the following command point for triggering switchover from an external Master External Trigger Point this command point is used to give the switchover command to the gateway from an external Master Hot Standby Protocol The Hot standby HSB protocol is used to maintain a complete up to date database on the warm gateway This feature w
30. da DEE 14 241 Installing EassyComnect ici leidos 14 2 2 Removing EasvConpect ran nn nr rn rra nn nn narran nn nn rra rra nn nn nn nnana naa 14 ASA cece eeneee sere tennessee eeeeeeeeeeeeeeeecaeeeeeeseeeeeeeeesseeeieeeeeenneeeenes 15 2 4 Exiting EasyConnect oo ceeeceeeeeeeeeeneeeeeeeeeecaeeeeeeeeeeaaeeeeeeeeeaaeeeeeeseeeaaeeeeeeaaeaaaaaaaeeeeeeeees 16 2 5 Using the Easyconnect Interface 16 3 Configuring Gaiewavs cnn nan nn nn nn nn nan RR nn rn nn rn RR RR Rnnnnrnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 19 3 1 Add Master Channel 20 SENO O eee eeennneeeeeeeeeeeeeeeteeeiaeeeeeeteeeaaeeeeeseeeneeeeeeseeeeeeeeeeeeeees 30 3 3 Add Master to Slave Map 30 4 Downloading Configuration File ooonnoocccnnnnnnocccccnnnnnncccccnnconnnonc nono nnnnnrr nn nnnn nana nn ncnn rra nr n rca rra 55 5 Redundancy Gupport nn nan nn nn nn nn nnnnnnn 56 GEN A EE 56 9 2 TYPOS OF SWITCNOVON iii eco 56 5 3 Redundancy Requirements conan nn cnn nn naar n nn nr narran nn nn nn nn nnnnnnnns 59 5 4 Gateway Redundancy Information and Control 59 5 3 e ee ie el lte ee EE 59 Redundancy Switchover Details 65 6 NERC CIP Supports EE 66 Retrieving Gateway ACCESS Log 66 T File Transfer SUpport sirsenis aineen cionado hea pauceupaanenssded ECKER de idea 67 7 1 Configuring File Transfer Master Channel 67 7 2 Configuring File Transfer Slave Channel 68 8 Parametrization through Pass Through Transparent Channel 70 9 Advanced User ConfiguratiONS oomocniniiiar a 71 Append
31. e 1 So these values should be designed optimally to suit the application Maximum The maximum number of This parameter is Heartbeat heartbeat failures which recommended to have the Failure are tolerated by each following values gateway before changing A the other gateway s ea status as offline Dual links 2 10 Diagnostic Enable diagnostic point Enable Point Event events Disable Ka lkitecha External 63 SYNC Software Field Level User Manual Version 1 0 0 11 Status Point Enable status point Enable Event events Disable Table 15 Node ParametersProfile Configuration The following table lists the status points and command point supported by HSB master With these points the user can monitor the status of both gateways and issue external switchover commands to the gateway Gateway ID Used to determine Binary Input 0 gt Main Gateway whether the gateway is Analog Input 1 gt Standby Gateway main or standby Gateway Used to determine Binary Input State whether the gateway is Analog Input currently Hot or Warm External Used to give Switchover Binary Output 0 Switch to Warm Trigger Point command to the Analog Output gateway K IL Status point showing Binary Input 0 gt Offline Communicatio whether the other Analog Input 8 1 Switch to Hot n Status gateway is Online or 1 gt Online Offline Gateway Shows the health ofthe Analog Input Bit 0 Unused Healthiness c
32. e Field Level User Manual Version 1 0 0 EasyConnect File View Configuration Settings Diagnostics Tools Help Mod VAe eQs a o DEF eo a ku Configuration Device VPNMode VPN IP Ping Status H Devices eege 552 KSGLSER1 Client 110 8 05 B By Protocol Configuration D T 553 KSGLS16R2 Client 10 8 0 9 E Channel 1 IEC 104 Master E Channel 2 IEC 104 Slave 4 Channel 3 IEC 103 Slave B J Channel 4 IEC 101 Slave E Channel 5 DNP3 0 Serial Slav E Channel 6 Modbus RTU Slava E J Channel DNP TCP Slave E Channel 8 Modbus TCP Slave mA Settings 552 KSGLS6R1 Protocol Configuration mA Settings E 4 553 KSGLS16R2 5 Protocol Configuration mm di Settings E Ey NetworkDesign e VPN Edit Export EC Cert files X Delete Figure 38 Download VPN To edit the VPN settings from the configuration window right click on the VPN node to get the Edit link as shown below Click on Edit Fie View Configuration Settings Diagnostics Tools Help d vrs QAREAPEO cE 00 a 4 Configuration Device VPNMode VPN IF 4g Devices 951 KSGLS16R4 551 KSGLS16R4 Client 10 8 0 5 Protocol Configuration ef d 553 KSGLS16R2 Client 10 8 0 H a Settings o 4 52 KSGLS6R1 9 Protocol Configuration AA Settings 553 KSGLS16R2 3 Protocol Configuration mA Settings E 27 NetworkDesign A PN HI J Download Export EC Cert files XK Delete Figure 39 Edit VPN Kalkitech Extern
33. ectly from the input server port to the output client port and in the reverse direction The Transparent Peer protocol can be associated to either any of the serial communication port of the SYNC or a TCP IP client por The SYNC models must be loaded with the license and firmware supporting Transparent Peer interface module and the configuration file containing all the specific information for the communication The detailed block diagram is shown in the figure below TEEN Protocol X Slave Protocol Y nooo Master da p Protocol Y Relay a ie A H Protocol X Meter e H DH Figure 64 Parametrization through transparent channel Kalkitech External 70 SYNC Software Field Level User Manual Version 1 0 0 9 Advanced User Configurations SYNC supports login to the unit over telnet The login and password is preset before shipment and is available from support kalkitech com on request and through fax Using the root login advanced administration and trouble shooting can be carried out The root user can set the SYNC to a predefined IP address manually You can also set up predefined routing for the IP address in a LAN WAN scenario as well as setup DHCP connection if required The root login also permits for starting and stopping the protocol engine inside the SYNC Please contact support kalkitech com for detailed information Kalkitecha External 71 SYN
34. elete Map To delete destination unit profile right click on Mapping tree node under destination unit select Delete Refer Figure below Kalkite ch External 31 SYNC Software Field Level User Manual Version 1 0 0 File View Configuration Settings Diagnostics Tools Help Bd vopAQA REEAGP PBO FEF 00 P R I Configuration Channel DNP3 0 Serial Master_Node_1 ly oO Devices y PE E Starting Point Number Of Deadband ls Select CROB E Protocol Configuration Basie Tipe EE Index Points 0 2147483648 Required py ia Deel DNP3 0 Serial Mas Digital Input Binary Inputs 65535 11 GC Node s i Profile Digital Input Binary Inputs A 1 4 Channel 2 DNP3 0 Serial Slav Digital Input Binary Inputs 2 1 mm AA Settings ee Diagnostics q NetworkDesign Add Row Modify Row Delete Row Channel 2 DNP3 0 Serial Slave_Node_2 x C Show Master Nodes Master Basic Type Object Type ae Event Class ait Figure 25 Delete Map 3 3 1 Auto Mapping Master to Slave EasyConnect Provides Options for mapping the master points automatically to a selected slave node User can either auto map the entire row configured in the master profile or some selected rows 1 Select the slave protocol to which the points are to be mapped 2 For mapping the entire rows in a profile Right click on the corresponding profile and click the option Auto Map as shown in figure below Kalkitech External 32
35. er due to external trioger nora nn cnn nnnnnnnnnnnnnnnnnn 55 Figure Si Self owth ernennen adi ei 56 Figure 52 Redundant configuration with IP Gwapping cnn nnnnnnnnnnnnnnnnnn 56 Figure 53 Redundant configuration with Alias IP sharing 57 Figure 54 Redundant configuration with No IP Gwitching 57 Figure 55 Channel configuration for achieving redundancy nn cnn cn nnnn nn nnnnnn 59 Kal lkitecha External 9 SYNC Software Field Level User Manual Version 1 0 0 Figure 56 Node configuration for achieving redundancy nnn 61 Figure 57 Retrieve Gateway LOQ ccccesesesccceeeeneseneeceeeeneeseeseeenenscaeeseaeenneneeeedeeeenscenenseeeeeneneennenes 65 Figure 58 Log saved successfully conmoccoiionisscccn ct 65 Figure e RE 66 Figure 60 Add Transfer Task codicia da 67 Figure 61 Add US Oricon it tddi 67 Elgure 62 Add Schedule cuca A de 68 Figure 63 Add BE TEE 68 Figure 64 Parametrization through transparent channel 69 Ka lkitecha External 10 SYNC Software Field Level User Manual Version 1 0 0 List of Tables Table 1 Document Details 4 Table 2 Document Authoring Details 4 Table 3 Organization of the document 6 Table 4 Document Conventions nene n nn non nnnnnnnnnnnnnnnnrrrrrinninnnnnnnn 6 Table 5 List of abbreviations rr non nnnnnnnnnnnnnnnnnnnnnnnnnrnnnnnnnnnenancnn 7 Table 6 Software Requirement cccccceeeeeeeeeeeeeeeceeeeeecaceaeeeeeeeeeeeeeeeeeeeeeeeeeeseeseecececeaccaceaeeeeeeeeeeess 1
36. etails given in each objects 3 See details in section 7 2 6 8 of IEC 60870 5 103 4 See details in section 6 2 of IEC 61850 7 3 Ka lkitecha External 75 SYNC Software Field Level User Manual Version 1 0 0 Appendix C Model Mapping Details The following table contains the details of old models of Kalki protocol gateways and corresponding new model names Old Model name New Model name KSGL S2R1 S4R1 S6R1 SYNC2000 S6R1 KSGL S4R2 SYNC3000 S4R2 KSGL S8R2 SYNC3000 S8R2 KSGL S16R2 SYNC3000 S16R2 KSGL S16R4 R4l SYNC3000 S16R4 Kalkitecha External 76 SYNC Software Field Level Kalkitecha User Manual External Version 1 0 0 77
37. ete Channel 3 Add Node or Station as shown in the figure below File View Configuration Settings Diagnostics Tools Help Bd vopAREGPEO LEF a Configuration Port Comt ty Devices Channel Type R5232 gt 551 KSGLSER1 RS485 R5422 mod Hal Dupi E Protocol Configuration ues e AE Channel DES ga leed 9600 ds Bolos E es Diagnostics Add RChannel E Eq NetworkDesign J Delete leven Flow Control None CTS Delay 0 65535 msec 15000 Figure 10 Add Station 4 Delete a station by selecting Delete from menu displayed on right click of selected station File View Configuration Settings Diagnostics Tools Help BM es Bor gsO CHEF 00 a Configuration Source Address E SO Devices Destination Address 4 Gr 551 KSGLSER1 j Link Status Request Interval 0 4294966 sec 5 834 Protocol Configuration Channel 1 DNP3 0 Serial Mas Enable Time Synchronization True e End of int val 0 4294966 sec 60 ation False H ei Settings Eq NetworkDesign True Integrity Poll Type End of Init Integrity Poll Interval 0 4294966 sec 60 Figure 11 Delete Station Kalkitech External 22 SYNC Software Field Level User Manual Version 1 0 0 5 To add Master Profile right click on Node and select Add Profile File View Configuration Settings Diagnostics Tools Help MA VISA RE GPBO SEL 00 a 85 Configuration Source Address 1
38. eway 1 Right click on the Settings and choose Add SNMP EasyConnect Walid EC Config ccc Tile View Cenfiquretion Settnas Diaqnostics Tools Help Mia o SP OL So pb SCHO 3 cf Conf guration A Devos LA S81 SN TAM SFR O E Protocol Configuration Channel Mcdous TOP F aster S Il iru Add Daup S Add SNMP i GJ Melwr kP sigri BPE aw Figure 45 Add SNMP Settings Fill the common configurable parameters The parameters are explained below Parameter Name Range Optional Default Value Values Description System Name 255 characters Depending on the gateway selected Name of the managed device being monitored Note Field is not editable System Description Protocol Gateway Description about the device being monitored Note Field is not editable System Location 255 characters kalkitech The physical location for the device being monitored System Contact support kalkitech com The interface to be contacted it can be a mail id Read Write Access private Community strings for read Kalkitech External 50 SYNC Software Field Level User Manual Version 1 0 0 Community String write access Read Only Access public Community strings for read only Community String access Table 12 SNMP Parameters 1 To Add User click Add User and Click Save button For details refer figure below Fill the common configur
39. f the source node This parameter is not editable Protocol of the destination node This parameter is not editable Indicates source data types from which mapping is carried out 2 Destination Node 3 Source Protocol 4 Destination Protocol 5 Source Types Indicates suggested destination data type for the specific source type to which mapping is carried out This indicates default suggestion and user can even change the same from the allowed types available in combo box 6 Destination Types Kalkitech External 34 SYNC Software Field Level User Manual Version 1 0 0 Destination Start Address This indicates the destination start address for the specific destination type This is generated after evaluating all the existing address and last address 1 of the already existing address is considered as default User can change the start address but it will again undergo evaluation There will be multiple address parameters based on the protocol used If it is IEC101 104 the same will only have IOA if it is IEC 103 it ftype will have amp number Table 8 Document Revision History The following points will be applicable to the Auto mapping window 1 Only data types which has at least a point available for mapping to the current slave shall be displayed in the auto mapping window Similar source types will be grouped and displayed as a single row in the Auto Map window In eac
40. h protocol the grouping of source types differ All the types coming under the Basic type of the source type will be available in the combo box options of Destination Types In cases where destination address range is not sufficient to map all the points an error message would be displayed in the validation stage after clicking the OK button Points will not be split and mapped for numerical address based protocols A continuous address space large enough to hold the points in a single row source is found and the points are mapped to those range Auto map shall be provided for all Master protocols except HSB Master and Logic Master On pressing OK from Auto map window points that can be successfully mapped are processed and for those which could not be mapped an error message is displayed Note All the other profile parameters will be default when auto mapped User can modify the row if required Ka lkitecha External 35 SYNC Software Field Level User Manual Version 1 0 0 3 4 Slave to Slave Mapping Feature Introduction The Slave to Slave mapping provides the facility to transfer some critical information between two master stations For provisioning communication between masters the corresponding source slave should be mapped to the destination slave The source slave is the slave which transacts with the master from which data has to be transferred and the destination slave is the slave which transacts with the mas
41. hannels running inside the gateway Bit 1 gt Channel 1 Bit 15 Channel 15 Gateway Used to determine Binary Input State whether the other Analog Input gateway is currently Hot or Warm Table 16 Profile configuration details for redundancy Ka lkitecha External 64 SYNC Software Field Level User Manual Redundancy Switchover Details Version 1 0 0 DCS Alarm S No Failure G w Action Giw A G w B Annunciation Normal operation Hot Warm Change oer at 1 Gateway A Power fails Gateway level Power Off Hot Gateway A Failure Downstream communication fails in Change over at 2 Gateway A Gateway level Warm Hot Upstream communication fails in Gateway A due to Ethernet link Change over at 3 removal Gateway level Warm Hot Upstream communication fails in Gateway A not caused by Ethernet 4 link removal Hot Warm Partial failure of integrated links between the gateways relevant only 5 for Dual integrated links Hot Warm Complete failure of integrated link Both gateways Gateway Failure 6 between the gateways become hot Hot Hot Critical alarm Change over at Gateway level to Issuing changeover request from the the requested 7 master to Gateway A state Warm Hot Table 17 Redundancy switchover details Ka lkitecha External 65 SYNC Software Field Level 6 NERC CIP Support User Manual Version 1 0 0 SYNC2000 S6R1 SYNC3000 S8R2 SYNC3000 S16R2 SYNC300
42. ider a given service provider LCP Echo Interval Depends upon service 20 Depends upon support provider from service provider LCP Echo Failure Depends upon service 3 Depends upon support provider from service provider Packet Compression Enable Disable Disable Depends upon support from service provider Authentication type PAP CHAP None PAP Type of authentication protocol used Client Name Configure if provided by service provider Else use default values Server Name Configure if provided by service provider Else use default values Password Configure if provided by service provider Else use default values Kalkitech Table 9 Dialup Parameters External 39 SYNC Software Field Level User Manual Version 1 0 0 Download the settings via File Download option and check the option Dialup Settings Download Device Name 551 x IP Address Use LAN IP el 192 168 100 58 CT Configuration File lt Fiom the configuration C License File C Update Package Dialup settings C VPN settings Figure 31 Download To delete the dialup settings from the configuration window right click on the Dialup node to get the Delete option as shown in figure below Click on option Delete File View Configuration Settings Diagnostics Tools Help RG VISA EGPAEO LEAF 00 a Configuration Pott Com a E porcos Baud Rate 1
43. ides secure communication between SYNC2000 S6R1 gateways present at different site locations to the single M2M gateway present on the control center Data between two ends are encrypted before transmission making it highly secure The SYNC2000 S6R1 will act as VPN clients and connects to the VPN server M2M Gateway using its public IP The client and server uses secret keys and encryption to establish a secure connection Both client and server will validate the supplied credentials before accepting a connection After the successful connection establishment the M2M Gateway will assign an IP addresses to each client gateway The IP address given to the client Gateways can be pre configured using the Easy Connect configuration utility The client can securely communicate with the server using this IP address A typical network configuration is shown below Internet 2 d V SH eg A A mg a d e GPRS EDGE gt Y d Network M2M Gateway gt G ai YNC SXR1 VPN Server SYNC Sp MM EE d Field Devices Pe Field Devices Figure 34 VPN GPRS network with Kalki Gateways Kal lkitech External 42 SYNC Software Field Level Configuring VPN User Manual Version 1 0 0 We can configure VPN Virtual Private Network settings for a converter whose configuration has been uploaded in the configuration window Right click on the Network Design node to get the option Add VPN settings
44. igure 58 Log saved successfully es pr Kalkitech External 66 SYNC Software Field Level User Manual Version 1 0 0 7 File Transfer Support Kalkitech protocol gateway models SYNC2000 S6R1 SYNC3000 S8R2 SYNC3000 S16R2 and SYNC3000 S16R4 have support for uploading and downloading all kinds of files through the File Transfer channel if they are supported in the firmware File transfer is done by configuring a File Transfer Master Slave channel through EasyConnect File transfer master channel is able to connect with FTP SFTP server programs running on a given remote system and upload download files and folders File transfer master configuration includes a schedule and file folder details File transfer slave will setup FTP SFTP sever inside the gateway to which FTP SFTP clients can connect There is a folder size limiting functionality implemented for these protocols which helps in keeping the given folders within a maximum size Following is a brief description of the steps involved in configuring a File Transfer master slave channel in EasyConnect 7 1 Configuring File Transfer Master Channel The steps for configuring File Transfer Master channel are as follows Choose File Transfer Master from Add Channel menu in Protocol Configuration e Type Remote IP Address in which FTP SFTP server is running s Select Protocol Supported and type Port No in the corresponding fields e Now right click on the File Transfer Master channel and
45. ile Points ccccececeeeeeencceeeeeeeeeeeeeeeeeeeeeeeeeeeedeeaaaaaaeeceeeeeeseeeeaees 32 Figure 27 Auto map selected profile points nana nnrnnnnnnns 32 Figure 28 Auto Map WINdOW E 33 Figure 29 Add MEET EE 37 Figure 30 Add DialUp EE 37 Figure E BEE 39 Figure 32 Delete Dialup simon iia diarias 39 Figure 33 Delete converter dalup conan nn nn nc cnnnnn nn cnn cnn nar n rca rr rnnnnrncn 40 Figure 34 VPN GPRS network with Kalki Gateways oooonoooocccncncncccocccocononcnancnnccnnnananannnnnnncn cnn nnnnnnnn 41 Figure 35 Add VPN DE 42 Figure 36 VPN Popp 42 Figure 37 CIO aaneren N EA anaE aaa 43 Figure 38 Download VDN ennn anaia EANNA AEAEE AENEAN 45 Figure 39 Ed VPN DEE 45 Figure 40 NDS 46 Figure 41 Delete VPN 2 ccccceeeesecececneeensneeeseeeeeesneeeeceenensnaanseeseensncnecestansnaaedeseeansnseeeeeenenntnnasientes 46 Figure 42 Delete converter VPN ooocoocccccccccoocccnocconononnncnncnnnnnnoccnnnnnnnn nn n cnn cr nan n nn carr naar nn rra nr rnnnnnnnran nananana 47 Figure 43 Export VPN Certificates nana rr cnn nn rana rr cn nr ner 48 Figure 44 VPN Diaonoetce nn cnn rr Eni Ea NE rra n rra Eana Nane 48 Figure 45 Add SNMP SattinigS ciociioadcciiaa odio aa 49 Elgure 46 Add USE ii a i E 50 Figure 47 Download SNMP Details nn cnnr cnn nn KAN AA rana 52 Figure 48 Delete SNMP Confouraton conan non AARNEN nana aran r rn rn ncnnnn 53 Figure 49 Download Configuration File 54 Figure 50 Switchov
46. ill copy the internal database of the hot gateway to the warm gateway Also all the events received by the hot gateway are mirrored in the warm gateway The following points should be noted while implementing a redundant configuration of SYNC using HSB protocol K lt alkitech External 59 SYNC Software Field Level User Manual Version 1 0 0 e Not all masters support this feature at the moment e Not all slaves support this feature at the moment Not all automation functions support this feature at the moment 5 5 1 Configuration of Hot Standby Redundancy can be configured for SYNC by adding an HSB Master channel to the EasyConnect One of the gateways is configured as Main and the other as Standby Details of configuration in EasyConnect is given in table Channel configuration parameters for achieving redundancy 5 5 2 Channel Configuration When the user adds a new HSB channel to the configuration the following window will be shown when the user clicks on Channel n HSB Master This corresponds to the channel parameters of HSB Master File View Configuration Settings Diagnostics Help DG ice e Bop BHO ei LU EC ees Channel State Enable G CESSES Physical Link TCPAP Serial Type RS232 Serial Mode Full Duplex Com port name Com Redundant Com port name Com2 Baud rate 9600 Parity Even Data bits 8 Stop bits 1 Flow control None IP Address 0 0 0 0 Redundant IP Address 15
47. is organized in to three parts as follows Chapter 1 SYNC The chapter provides an introduction to the SYNC Field1000 2000 30 00 Chapter 2 Getting Started This chapter provides instructions on getting started with the SYNC Chapter 3 Configuring This chapter gives you information and instructions Gateways for configuring the SYNC Gateways Chapter 4 Downloading This chapter gives you information and instructions Configuration File for configuring the master stations Appendix A Appendix A to C This section provides references and other to C information Table 3 Organization of the document Documentation Conventions The following table shows the conventions used in the document 1 Field Name Screen Name and Arial Bold face font Button Note 3 Each step in the task is numbered Identified by numbered list 1 First Step 2 Second Step Table 4 Document Conventions Ka lkitecha External 6 SYNC Software Field Level User Manual Version 1 0 0 List of Abbreviations The following table shows the acronyms abbreviations used in this document CHAP Challenge Handshake Authentication Protocol DCCP Diagnostic and Converter Configuration Protocol Table 5 List of abbreviations Ka lkitecha External 7 SYNC Software Field Level User Manual Version 1 0 0 Table of Contents 1 SYNC Field Level 1000 2000 3000 eise geg dar ERAN KANA EEEREN 12 Vl Overview de 12 12 E Ee 12 1 3 EMVIFOMMEN EE 13 2 Getting
48. ited I O to a 16 channel multi protocol data concentrator converter The different product models vary in processing power storage capabilities number of channels and types of channels to suit different requirements However they present a singular front end via the SYNC Configuration tool Easy Connect 1 2 Easyconnect The complete configuration of SYNC is done through a configuration utility software called EasyConnect which includes defining protocol attributes mapping data and achieving the functionalities like firmware updating IP setting diagnostics etc EasyConnect generates a configuration file in Extensible Markup Language XML format as the output You can download the configuration file using the download function in EasyConnect for configuring the hardware gateway EasyConnect can be used for e Any communication with the SYNC e Update firmware e Upload or download configuration file e Reset the SYNC e Configure and map the protocols supported on the SYNC e Manage different profiles in your hard disk for different conversions when using SYNC The configuration is simple to carry it out on your own e Supports packet diagnostics of the various channels K lt alkitech External 12 SYNC Software Field Level User Manual Version 1 0 0 1 3 Environment This section specifies the software and hardware requirements to install and use EasyConnect configuration utility 1 3 1 Software Requirements The software requireme
49. ix A Special Case Configuring PPP IEC 61850 Server and ICCP peer 72 Appendix B Flag conversion in GN 73 Appendix C Model Mapping Details eee ceeceeeeeeeeeeaeeeeeeeeeeeeeeeeeeeeeeeeeettttteeeeeeeeeeeneeeeeeea 76 K lt alkitech External 8 SYNC Software Field Level User Manual Version 1 0 0 List of Figures Figure 1 EasyConnect user interfata ronca r rra nn cra r rra 14 Flgure 2 User Interface aia ri a s 15 Figure 3 Elle Melia ia iaa 16 Foure te el 17 Foure oD Add Devi E 19 Figure 6 Modify Device nasin a E de 19 Figure 7 Delete Gate Way Lidia di od a dato 20 Figure 8 Add Master Protoco oicoooicoioicic de id a a i 20 Figure 9 Delete Chamel aoomiai a est 21 Figure 10 Add St ui a crio 21 Figure 11 Delete Salina nL eka sien ees 21 Figure 12 Add Profile gt Eege e AEN 22 Figure 13 Export Profile cc iia 22 Figure 14 Import Profile ccoo ao edo 23 Figure 15 Delete Profil 1202 lia ici 23 Figure 16 Add FROEN elas EE NEE 24 Figure Edel A EE 24 Sieft Ve 25 Figure 19 Excel Export amp IMport coo icons ici aia ec 26 Figure 20 Excel ProflO coociooion idilio iene een 27 Figure 212 Excel Import POPUP scarce sais cdversaznaeacsincawsnvaresaananatheeddncaanacsensocvedveshueausndeysaaangaagaanbabeedeneetonaaiate 28 Figur 22 Delete Profile voca dieta 28 Figure 23 ACG Map EE 29 Figure 24 Modify Map EE 30 Figure 25 Delete Map ieigekge fr ie ioi E RiNS olle elias 31 Figure 26 Auto map entire prof
50. l is either authNopriv or authpriv Authentication Password passkalkitech The password used in conjunction with the authentication protocol Privacy Protocol DES AES DES The protocol used for privacy that is to encrypt the data portion of the SNMP packet Note Applicable only when selected Security Level is authpriv Privacy Password passkalkitech The password used in conjunction with the Privacy protocol Kalkitech Table 13 SNMP User Parameters External 52 SYNC Software Field Level User Manual Version 1 0 0 2 Check the SNMP settings box in the Download command window as shown in the figure below and click Download LIM EE Device Name 551 e SYNC200056R1 nd IP Address UseLANIP zl 192 168 100 133 Configuration File From the contiguration gt Si TT License File Y ez Update Package E Sa Zl Dialup settings VPN settings Je SNMP settings CD ownload Y Close Figure 47 Download SNMP Details Note Restart is required after downloading the settings for the changes to take effect Kalkitech External 53 SYNC Software Field Level User Manual Version 1 0 0 3 7 2 Delete SNMP Details To delete the SNMP settings from the gateway 1 Right click on the SNMP node and choose Delete File View Configuration Sattings Diagnostics Tools Help Medivrc QxrborgeOi ck Ce
51. la A gt F E Ed a sc 00 Conditional For ee B z uio A SE SS 28 a 2 22 Formatting as Ta Clipboard Font fa Alignment fa Number la Styles Al zk f Protocol Name IEC 104 Master Ea SEE AOA Manes E F G Protocol Name IEC 104 Master I 2 3 ASDU Type Information No of Point Deadband Is Select Required Comments Single Indications 1 1 Figure 20 Excel Profile Excel Import Select Excel Import from the context menu of profile and choose the excel worksheet prepared to import See figure Certain conditions are applicable for the Excel Import functionality Only worksheets previously exported from Easy connect can be imported User should add at least one point other than communication diagnostic point in the profile and use Excel Export to generate an excel worksheet template Configure required points in this file and save Note that Easy Connect expects a specific format for the worksheet So the user should refrain from modifying the format of the sheet in any manner Only the contents may be changed The protocol name in the Excel worksheet should match with the protocol of the profile to which it is imported For example an excel worksheet exported from IEC104 Master can only be imported to a profile under an IEC104 Master Channel Easy Connect validates all the parameters configured in the excel worksheet before importing and will push an error message if the validation fails All the avai
52. lable options for a parameter will be available in the worksheet cells independent of the type of point selected For example in Modbus Master Function Type Read Coil status is not applicable for object type Analog Input But this option will be available in the excel worksheet cell User should select the valid options while editing the worksheet Any failure in validation will terminate excel import Kalkitech External 28 SYNC Software Field Level User Manual Version 1 0 0 e After validation all the existing profile rows will be replace by the points configured in the worksheet For points that are already mapped to a destination protocol For all the rows where the address parameters are not modified the other parameter values are read in from the worksheet e Ifthe address parameters are changed in the worksheet Easy connect will pop up a message as shown in figure below On selecting yes the mapping will be deleted and the points in worksheet will be imported On selecting No the excel worksheet will not be imported Excel Import Profile rows involved in mapping are missing from the Worksheet Do you want to Import the Worksheet Figure 21 Excel Import Popup To delete a Profile right click on added profile and select Delete File View Configuration Settings Diagnostics Tools Help td vagar Eor BO DEF 00 Configuration Ge Channel DNP3 0 Serial Master_Node_1 y Ly Devices
53. module in SYNC can be done with EasyConnect configuration Utility The configuration for any protocol conversion function can be divided into a few logical steps Master protocol configuration will be divided into the following sections namely Channel Node Profile and Row addition For a slave Profile Channel and Node are configured A master and slave can be mapped by the Add Map option The following steps explains how to configure protocol modules for any SYNC model Steps to configure a gateway 1 Add Master channels 2 Add Slave Channels 3 Add Master to Slave Map 4 Slave to Slave Mapping 5 Dialup Support 6 VPN Support 7 SNMP Support Step 1 2 and 3 deals with protocol conversion function of the gateway Step 4 and 5 deals with additional optional communication features of the gateway For normal protocol conversion requirements users can stop at step 3 You may proceed to step 4 or step 5 when you use any of the described features Ka lkitecha External 19 SYNC Software Field Level User Manual Version 1 0 0 3 1 Add Master Channel 1 Add converter either by selecting a converter model from Device configuration section or right click on Devices in the left hand side pane as shown in figure below P EasyConnect SYNC2000 S4R10EM SYNC3000 S4R2 4 SYNC3000 512R6 4 SYNC3000 16R4 A SYNC4000 KPDC Figure 5 Add Device If you want to modify an added gateway model right click the selected
54. mponents are 1 Menu 2 Toolbar 3 Workspace Kalkitech External 16 SYNC Software Field Level User Manual Version 1 0 0 2 5 1 Menu The Menu contains options to execute all the actions that can be done using EasyConnect The different Menus are 1 File Menu To start a new configuration opening a saved configuration file saving the configuration etc are the options which are available in the menu A few of these actions are also made available in the toolbar View Configuration Settings Diagnostics Help new Can Bor BHO _j Open Ctro el Save Chris Save s BR Gatway Controller Version No Of Serial Ports No Of Ethernet Por Maximum Disturbar Recent Files KH ru cti o Figure 3 File Menu 2 View Menu The View Menu contains the option to enable or disable the toolbar buttons 3 Configuration Menu The Configuration menu contains options corresponding to the node in the Tree View that has been selected Depending on the node selected the options available in the Configuration menu varies These actions can also be availed by clicking the right mouse button on the node This menu is extensively used in configuring the SYNC and is well explained in the respective sections 4 Settings Menu The Settings menu contains the generic actions such as downloading or uploading configuration restarting the device IP configuration firmware starting and stop
55. n the File Transfer Slave channel and choose the option Add Station n the General tab of node parameters select Authentication Scheme Inthe Users List tab add users by specifying User name and Password The remote clients can use them for password authentication Username user XXXXXXXX Password Save Cancel Figure 61 Add User Kalkitech External 68 SYNC Software Field Level User Manual Version 1 0 0 In Size Limit tab add a schedule for running size limiter by specifying the time period You can add as many schedules as required Schedule Name Schedule Scheduling Mode Weekly Day of Week Tuesday Day of Month Time 10 12 0 Schedule Multiplier 1 65535 1 Figure 62 Add Schedule Now click on the schedule and add folder by specifying the Folder Name and Rollover Limit The size of the specified folder will be checked and limited to the rollover limit in the scheduled interval Folder Folder Name home lite out Rollover Limit 1024 Figure 63 Add Folder KQ lkitech External 69 SYNC Software Field Level User Manual Version 1 0 0 8 Parametrization through Pass Through Transparent Channel This module in the SYNC protocol converters enables to parametrize the relays or IEDs with the particular configuration software for the relay IED The transparent channel pass through routes the frames dir
56. netmask 255 255 255 Server LAN WAN IP 1688 0 Port 1194 Server VPN IP Select All None Auto Generate YPN IP Select Device VPN Ip VPN Mode 551 KSGLS16R4 Server 553 KSGLS16R2 Figure 37 VPN Parameters 3 Once this is done click OK A new dialog box will appears as shown below Fill in the Ka lkitech External 44 SYNC Software Field Level User Manual Version 1 0 0 required parameters and click Save Note For any VPN configuration one of the devices is configured as server and the rest of the devices operates in client mode Network Address 10 8 0 0 It signifies the IP address template range over which the VPN IPs can be configured Subnet Mask 255 255 255 0 A valid subnet address Port NA 1194 The UDP port used to establish the VPN connection Server Device SS1 Device Choose the device you want to set as the VPN Server Device Server LAN WAN IP 0 0 0 0 Give the LAN WAN IP of the VPN server chosen above Server VPN IP NA 10 8 0 1 The VPN IP of the server allocated by the system Client VPN IP NA IP Address address of the VPN clients This can be generated by clicking the button Auto Generate VPN IP Table 11 VPN Parameters 4 The VPN settings are saved to the configuration To download right click the VPN node and click the Download link that appears as shown below Kalkitech External 45 SYNC Softwar
57. nts are stated as follows EasyConnect The protocol configuration utility Operating Windows 98 Required or Higher System Table 6 Software Requirements 1 3 2 Hardware Requirements The hardware requirements are stated as follows HardDisk 1 5 GB or more Space DPI Setting 96 DPI Table 7 Hardware Requirements Ka lkitecha External 13 SYNC Software Field Level User Manual 2 Getting Started Version 1 0 0 This sections familiarizes you with SYNC and EasyConnect and gives step by step instructions to get started with the SYNC and EasyConnect This section covers the following topics e Installing EasyConnect Removing EasyConnect e Starting EasyConnect e Exiting EasyConnect e Using the EasyConnect interface 2 1 Installing EasyConnect EasyConnect uses Microsoft XML engine to manage XML files You have to install Microsoft XML engine before installing EasyConnect You can get the EasyConnect installable files from CD supplied along with the SYNC gateway e Download from the Website please contact sales kalkitech com for the link to download the file Note Follow default options for installing EasyConnect Prerequisites You have to obtain EasyConnect before you can install it support kalkitech com for any further information To install EasyConnect perform the following steps 1 Double click the EasyConnect icon The Welcome window appears 2 Click Next The Choose Destination Lo
58. om the context menu as shown in figure below Kalkitech External 26 SYNC Software Field Level User Manual Version 1 0 0 File View Configuration Settings Diagnostics Tools Help PB d vopdar Bop 80 SEFPBR OQ AR x S d S Configuration Channel 3 IEC 104 Master_Node_5 Y E Ly Devices e 551 SYNC2000S6R1 l Information a Y Protocol Configuration Row Number Basic Type ASDU Type Zoe S d Channel IEC61850 Peer Ser Row Digital Input Single Indications 65535 L2 Node_1 t Row2 Digital Input Single Indications 1 Subsriber Mode 2 Channel 2 1061850 Peer Clie Node_3 Publisher Node_4 Channel 3 IEC 104 Master eS Node_5 Profile a Settings Add Points E NetworkDesign Export Profile Figure 19 Excel Export amp Import Exported excel worksheet format is shown in figure above The worksheet will contain the protocol Name All the configurable parameters in the Profile Row window of the specified protocol form individual columns All the available options for a parameter will be available in the combo box independent of the type of point selected Note Communication diagnostic point will not be imported to the excel worksheet Kal lkitech External 27 SYNC Software Field Level User Manual Version 1 0 0 Qu bed ic y Book2 Microsoft Excel E Home Insert Page Layout Formulas Data Review View d calibri ss An General y a E Ga MA gt ai Paste Eu
59. ping etc 5 Diagnostics Menu The Diagnostic menu contains action items for the diagnostic functionality The options available in diagnostic menu are Traffic Monitoring PDC Diagnostics and Gateway Access Log 6 Tools Menu Tools menu contains options to set the EasyConnect parameters like Timeout settings Kal lkitech External 17 SYNC Software Field Level User Manual Version 1 0 0 7 Help Menu 8 The Help menu contains the options to get EasyConnect Help documentation and Information about EasyConnect 2 5 2 Toolbar The toolbar provides easy access buttons to menu options and they are 1 2 3 4 File Settings Diagnostics Help These are selected options from the toolbar menus They can be enabled or disabled in the View Menu Tool tips are available for each toolbar button describing the functionality associated with each of them Diagnostics Tools CEAIE DAT Figure 4 Toolbar 2 5 3 Workspace The workspace section is the place where all the configurations regarding the different channels stations etc are done Depending on the node selected in the Tree view the options available in the Workspace may vary These are described in the configuration of each item in detail Kalkitech External 18 SYNC Software Field Level User Manual Version 1 0 0 3 Configuring Gateways You have to configure the SYNC before it can be run The configuration of any protocol interface
60. rnal 24 SYNC Software Field Level User Manual Version 1 0 0 File View Configuration Settings Diagnostics Tools Help Bd 068 For mO SEF OF e E Node_1 Profile 9 i LES aesan TT E ee Diagnostics Export Profile T NetworkDesign I Delete lt m Add Row Modify Row Delete Row Figure 16 Add Row el C Show Master Nodes E f Configuration Channel 1 DNP3 0 Serial Master_Node_1 el E Lp Devices See at 51 KSGLSER1 Starting Point Number Of Deadband Is Select CROB Er Protocol Configuration DEE EE Index Points 0 2147483648 Required ae 6 4 Channel DNP3 0 Ses Digital Input Binary Inputs 65535 D Select a row from the profile grid Click on Modify Row button A new window will pop up with values of selected row File Wem Configuration Settings Diagnostics Tools Help BGH VA QeboraeO FEF 00 E Configuration ei Ey Devices 4 551 KSGLSER1 E Si Protocol Configuration Channel 1 DNP3 0 Serial Master_Node_1 el EE l Sta Starting Point Number Of Deadband l CROB El mE Index Points 0 2147483648 Required SE 2 Channel 1 DNP3 0 Serial Mad E E Node_1 Profile 6 Settings ee Diagnostics Gy NetworkDesign Digital Input Binary Inputs 65535 1 Profile Row Object Type Binary Inputs Starting Point Index 12 Number Of Points 1 Deadband 0 2147483648
61. ser Manual Version 1 0 0 File View Configuration Settings Diagnostics Tools Help Md VAGQ8BonpeO GE 00 5 8 Configuration Source Address i E aise ee aie ty Devices Destination Address 4 551 KSGLSER1 Se Be E E Ra A Link Status Request Interval 0 4294966 sec 5 2 Protocol Configuration B J Channel 1 DNP3 0 Serial Mas Enable Time Synchronization True f Init l Add Profile n Type End ol Ini H a Settings 5 Interval 0 4294966 sec 60 S d alculation False Ey NetworkDesign Delete True Integrity Poll Type End of Init Integrity Poll Interval 0 4294966 sec 60 Enable Auto Event Poll True Unsol command type at restart IIN Disable Figure 14 Import Profile To delete a Profile right click on added profile and select Delete File Weu Configuration Settings Diagnostics Tools Help Mid vagatur mO DEF 00 E 4 Configuration 5 4 Devices Be Starting Point Number Of Deadband IsSe a Protocol Configuration Basic Type Object Type Index Points 0 2147483648 Reg S Channel 1 DNP3 0 Serial Mas a Node_1 gt e mA Settings Add Points es Diagnostics Export Profile E NetworkDesign Delete risers DINED ee el Digital Input Binary Inputs 85535 4 iit el C Show Master Nodes i Figure 15 Delete Profile 6 To add Master Row right click on Profile and select Add Points as shown in the figure below Kal lkitech Exte
62. ses any of them depending on the state of the gateway Because of this the control center can connect to the hot gateway using a fixed address This ensures that no special network configuration is needed at the control center in fact when the control center connects to the known IP address it has no indication which gateway is hot and which one is warm The warm gateway can also be accessed with it s public IP address for maintenance purposes Kal lkitech External 57 SYNC Software Field Level 5 2 4 User Manual Version 1 0 0 Redundant Configuration with Alias IP sharing eS ca Gateway A Hot IP A Alias IP Add Gateway B Warm Ek Switchover IP B _ Alias IP B IP A IP Address Gateway A Warm Gateway B Hot Figure 53 Redundant configuration with Alias IP sharing In this mode each gateway has it s own private IP address Also both gateways share a public IP address to which the control center can connect This IP address is set as an Alias IP address for the interface This ensures that no special network configuration is needed at the control center When the control center connects to the alias IP address it will always connect to the hot gateway The hot and warm gateways can be accessed with their private IP addresses also for maintenance purposes 9 2 5 Si Gateway A Hot Gateway B Warm Redundant Configuration with No IP Switching le Switchover _ GA iP IP B G
63. ter to which the data has to be transferred User can add profile and configure command points under the source slave nodes These command points can be mapped to input points A command received on the source slave will be sent as an event to the mapped destination slave Depending on the command type and protocol a positive acknowledgment will be sent back to the source slave after sending the event notification If the command point is not mapped a negative acknowledgment will be sent back For the protocols and particular data types which do not support event intimations the data can be retrieved by polling Note Slave to Slave Mapping does not allow multiple mapping Also a single row can only be mapped to a single node For example consider a row with three points Each of these three points should be mapped to a single node Splitting and mapping to different nodes is not permissible Also the quality of the points configured will always be good And the time stamp of the event will be the time taken from the converter when the command is processed Configuration Details 1 Add slave channels and nodes source and destination 2 Add Profile under source Slave and configure Points as shown in figure below Configuration d annel 1 IEC 104 Slave_Node_1 v O Devices 4 551 KSGLSER1 Information Number of 3 Protocol Configuration Basic Type ASDU Type Kruser Points ve Digital Output Single Commands 1 2 Chane Modb
64. ue to external trigger In this mode the gateway will not take a switchover decision on it s own The switchover is triggered by an explicit command received from external master To assist in making a decision the external master can monitor the gateway status via some default status points Based on this information the external master can change the gateway state Kalkitecha External 56 SYNC Software Field Level User Manual Version 1 0 0 5 2 2 Self Switchover Sl Gateway Failure P External Trigger gt cn Ex E Hot Warm Warm Hot Figure 51 Self Switchover Self switchover mechanisms extend the functionality of external trigger switchover by providing provision for making switchover decision from the gateway itself The gateway monitors the status of all the connected channels as well as the status of the other gateway via an integrated link In this mode when the warm gateway detects a failure of hot it changes it s state to hot Also a communication failure in active channels of the hot gateway will result in the warm gateway switching to hot 5 2 3 Redundant Configuration with IP Swapping Ela Ch Switchover Hot IP gt H gt Address Warm Warm IP Address IP Address ey e ey cy Gateway A Hot Gateway B Warm Gateway A Warm Gateway B Hot Hot IP Address Figure 52 Redundant configuration with IP Swapping In this mode the hot and warm gateways share two public IP addresses Each gateway u
65. us TCP Slav o E Node_2 ei Settings Ey NetworkDesign Add Row Modify Row Delete Row hannel 2 Modbus TCP Slave_Node_2 gt E E Master Basic Type Object Type Function Type lt e E AddMap Modify Map Delete Map Kalkitecha External 36 SYNC Software Field Level User Manual Version 1 0 0 Select destination Slave and click on AddMap to add the mapping as shown in figure above Modify mapping and Delete mapping functions identically to the master to slave mapping counterparts 3 5 Dialup Support SYNC series gateways can be configured to work with a dialup modems SYNC series with a built in modem can be ordered separately SYNC series can be also be used with external modems Configuring Dialup Modem We can configure Dialup Modem settings for a converter whose configuration has been uploaded in the configuration window 1 Right click on the Settings node to get the option Add Dialup settings File View Configuration Settings Diagnostics Tools Help Mid 71SQPEGPABO GE 00 E 4 Configuration 4p Devices 551 KSGLS6R1 7 Protocol Configuration 24 Channel 1 037118 Master Pa Add Dialup e 552 KSG 5 Protocol Configuration mA Settings Eq NetworkDesign Sh Figure 29 Add Dialup Ka lkitech External 37 SYNC Software Field Level User Manual Version 1 0 0 2 Click on Add Dialup Add Dialup window will be displayed Enter the relevant changes
66. yConnect_V4 0 0 Figure 1 EasyConnect user interface Kalkitech External 15 SYNC Software Field Level User Manual Version 1 0 0 2 4 Exiting EasyConnect You can close EasyConnect at any point during the running of the application To exit EasyConnect perform the following steps 1 From File menu choose Exit If there is any open configuration a warning window will appear to confirm whether the user would like to save the configuration before closing EasyConnect 2 Click Yes to save the configuration at desired location before exiting EasyConnect Click No not to save the configuration and to continue with exiting EasyConnect Click Cancel to cancel exiting EasyConnect 2 5 Using the Easyconnect Interface This section gives you an overview of the elements and menus in the user interface using the graphical user interface diagram The components in the user interface of EasyConnect are shown in the figure below and each one is described in detail Easy onnect File Ven Configuration Settings Diagnostics Tools Help a 4 Configuration GENERAL TRIGGER Devices G 551 KSGLS6R1 Node Address 1 254 1 El Protocol Configuration Enable Time Synchronization False 3 a d RES Starting Offset Address 0 65525 0 mE Node 1 8 Time Synchronization Interval 1 4294967 seconds 60 Eg Settings Eq NetworkDesian Event on Quality Change Extel Figure 2 User Interface The Co
Download Pdf Manuals
Related Search
Related Contents
MANUAL DEL 12007 - Portal de Servicio Koblenz Skywriter and Dimension projectors - X 施工・取扱説明書 Telex FMR-70 Microphone User Manual USER MANUAL - WiFiRanger OITDA/TP 11/BW Installation Operation Manual TERMOS DE GARANTIA RO - Autohaus Habinghorst Shop INSTALLATION MANUAL Copyright © All rights reserved.