STK-406 Pet Immunity PIR Motion Detector S A M T E K Installation
Contents
1. N MEM TAMP RELAY Energy Analyses Energy peak duration width amp shape r tT TRETA Digital Auto Pulse 2 levels adjustable SE DVOLRS Processing Digital SHIELD sofware Yes CC SN Digital Temperature Yes Compensation A D Type Resolution re ree a D Additional Sampling SLs aaa Dynamic Range Frequency Response 6 Sampling pe eR a Characteristics Detection Speed Detect Animal Weight Operating Temperature RFI EMI Rejection 60 70 V M Coverage Range S Alarm Indication Red LED lights 2 seconds Aiarm Output Normal closed 28Vdc 0 15A optional normal open Anti Tamper Switch Normal close output opens when cover removed 0 15A 28Vdc Alarm Memo LED light up for 5 minute upon disarm Max 95
2. the lower and upper sensor see FIG 2 Due te the small height and volume of a pet they will not generate the required signal value normally recognized as an alarm situation Any PCB adjustrnents should be followed by a walk test of the protected area Walk testing verifies that the required coverage is in place Walk Testing At 20 C in high sensitivity mode you should not be able to cross more than one complete zone consisting of two beams left and right sensor detecting elements in the coverage area with any kind of movement running fast or slow walking In low sensitivity mode the amount of movement required to generate an alarm is doubled The approximate width of a full beam at 9m 30 ft from the detector is 1 5m 4 9 ft Please see FIG 2 Note Do not walk facing and towards to a PIR motion detector because the detector can not detect this movement direction Your movement direction should be vertical to the beam of detector Alarm Memory Using the programmable output of the control panel to generate 12V to the terminal MEM of 406 upon arming will trigger the alarm memory function of 406 If the detector is alarmed during armed period the alarm signal will be memorized and the LED will lights for 5 minutes when the panel is disarmed delete 12V mportant Notes Upon completion of installation all openings in the detector should be sealed with silicone to prevent drafts or insects from entering the detector Pleas
3. 2 ON Default Setting normal operation mode PET IMMUNITY LENS PATTERN OFF detector is switched off and has no working TOP VIEW COVERAGE ADJUSTMENT Using the standard lens at the recommended installation height of 2 1m 7 ft 10 the 406 will provide full coverage from 1 2m 4 ft to 9m 29 ft without any dead zones Please ensure that the PCB is fixed at the 2 1m 7 ft mark A small vertical adjustment of the PCB 0 5mm may be required Please see FIG 2 Avoid placing the detector in proximity to the following sources of interferences reflective surfaces direct air flow sources of steam oil vapor infrared light sources and objects causing temperature changus such as heaters refrigerators and ovens and infrared light sources After selecting the detector s location drill holes for the screws as per fig 1 and Fig 3 Corner mount Carcfully remove the PCB 9 by loosening PCB screw 8 and utilize holes A B Cand D Flat surface mount Carefully remove the PCB 9 by loosening PCB screw 8 and utilize holes E F Gand H Wiring Run the wires through entry hole I and J and connect them according to the marking on the plastic back and as per FIG 4 urn On the Detecto Self testing program Turning on the detector initiates a self testing program for the signal processor memory and relay A flashing light for 60 seconds will indicate that the system is fully operational FIG 3 z ACK TOP VIEW Digital Signal Proces
4. STK 406 Pet Immunity PIR Motion Detector SAMTEK Installation Manual SECURITY SYSTEMS FIG 1 afro you io choosing 406 pet immunity motion detectors As an EXPLODED VIEW inforn ed security professional you ve selected a state of the art self detecting detection system that incorporates the following unique features Two Dual Element Sensors 4 8 LENS Pet friendly Lens Pattern NS 100 Digital Motion Detection D COVER Digital Shield algorithm software Digital Auto Pulse Processing Patented BEZEL PIN 5 Digital Auto Temperature Compensation ELECTRICAL 7 4 BEZEL Metal Shield for RFI EMI rejection CONNECTOR Auto Background Analyses PCB 9 6 BEZEL PIN Comprehensive LED display PCB SCREW 8 Please study this instruction manual carefully to ensure proper installation of the 406 RF METAL Do not touch the sensor surface as this could result in detector SHIELD a malfunction IF NECESSARY CLEAN THE SENSOR SURFACE QS il LED USING A SOFT CLOTH WITH PURE ALCOHOL DIP Switch Setting 406 has two blue DIP switch for setting operation mode Piease find out the switch from FIG 1 The method of setting is as follows 2 COVER PIN ON on 1 2 off DIP Switch 1 Sensitivity Setting ON Default Setting high sensitivity mode OFF low sensitivity mode set to this mode when under disturbance environment in order to avoid false alarm DIP Switch 2 Detector ON OFF Switch FIG
5. e keep the lens clean in order to achieve good effect Burglar alarm systems should be check once a week Warranty The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of one year Except as specifically stated herein all express or implied warranties whatsoever statutory or otherwise including without limitation any implied warranty of merchantability and fitness for a particular purpose are expressly excluded Since Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller Seller cannot guarantee the performance of the security system Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specifications In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper incorrect or otherwise faulty installation or use of the merchandise sold Specification FIG 4 ALARM RELAY POWER INPUT 12V0C Sensor Quantit ual element PIR Geomet ectangular i MEMORY ANTI TAMPER INPUT SWITCH A J r A an 5 F a n Pz
6. sing BAC O Movement Analysis Movement generates a unique sequence of signals For each signal Digital Shield software measures and calculates the signal s parameters amplitude duration peak level polarity rise time and shape in real time and then stores them in memory Each signal is compared with a reference bank of movement and non movement signals If the signal does not meet movement criteria it is immediately rejected Auto Pulse Signal Processing APSP measures energy from each detected signal and stores it in memory To generate an alarm the memory must reach a required minimum level Thus in the presence of high level signals very low risk of false alarms the detector immediately generates an alarm functioning as a non pulse count detectur while low level signals presenting a high risk of false alarms will cause the detector to automatically switch to a very high pulse count mode resulting in excellent protection against false alarms Pulse counting rate depends on signal energy levels and can go much higher for RFI signals Due to the complicated software computing procedure sometimes the alarm will be delayed for 0 25 1 second after actual movement Pet Immunity bai The 406 has two dual element sensors for of 3 D space detection In addition it combines with the proprietary Pet friendly lens greatly decrease false alarms created by pets In order to generate an alarm an object must cross the beams created by both