Home
BodyMetrix™ System User's Guide
Contents
1. A PLEASE READ INSTRUCTIONS BEFORE USE A Important Operating Instructions Intended Use The BodyMetrix System is only intended to be used on generally healthy adults and children 6 or older and is not for diagnosis of disease or condition For more information please review Page 4 of this User s Guide Environment Th Operating Temperature 0 to 60 Celsius Operating Humidity 5 to 95 Operating Altitude 0 3500 meters By IntelaMetrix Power Requirements USB Cable 2 5 Watts 5V and maximum 500 mAmps Computer Requirements Windows XP or Vista or Windows 7 Mac OSX with virtualization software and Windows XP or Vista Min 1 GB of RAM with 200 MB available for BodyView USB Port CD ROM drive Min Screen Resolution of 1024 x 768 Device Model Number BX2000 BodyMetrix System User s Guide BodyMetrix System User s Guide Copyright 2010 IntelaMetrix Inc Table of Contents indications TOP Us Enas a E eared eee eee 4 installing SOWIE nna a E a 5 Using the BodyMetrix SySteEM ccecceceeceeseeeeeeceeseeeeseeteeseeeeeeeeaes 9 Starting BodyView Software cccccecseceeceeeeceeceeseeeeceeseeeeeeeeeees 9 AAMINI O aea a A siete ieee A 10 Unlocking SoftWare esirin a aa a a ita 11 Client Mandage asime aaa 11 Creating a NEW CGT icici cacicniot cu siaieesabnier a A 12 Opening Clients Prole sirro nn a 13 DEMONStFatiOn MOdE sornione a 14 BOAVNVIEW Tiener a a a a a 14 Measuri
2. ultrasound gel to the device Step 4 Place the device on the skin at the desired starting position and slide it along the complete section to be scanned to evenly spread the gel Now move back to the start position press and hold the measurement button on the device and slowly slide the device along the complete section to be scanned Ideally the scan speed is adjusted to allow the image to completely fill the Scan panel Step 5 When the scan is complete a cross sectional image will be created that shows the tissue structure along the complete scan region The image will show a variety of tissue features including the fat layer muscle layer and if applicable bone The screen below shows an example of a scan along a thigh from the midpoint to the knee The Measurement is made by simply clicking on one point of the image and dragging to the other point A rectangle is added to the image with the measured thickness being displayed in the Measurement area Bodyview 2p 7 Eel Personal ID 1975M37 Age 35 years Gender Male a Measurement Intensity 180 Tissue Cross Section liigh Measurement Data oO 4 i ot 846 A 6S Ai R E 30 44 a 2 SS Aa Depli imm B ebara AN Mazimum Depth 60 0mm Track Interface Clear Track Bochymetrixs Device Device status Ready Save image Compare Images InielaMetria 2005 Interpreting Scans It is necessary to know how to interpret a body scan to take full advant
3. 1 Weight PRES f bametrix 2010 essential fat is required to cus BMI response to metabolic demands VIBMR Studies show that the percent of Recommendations ficantly increases the risk of coronary heart disease strokes d M Relative Disease Risks arch also shows that the location of body fat is a contribu er health risk than excess in the thighs M Weight Trend M Weight BF Trend M Thickness Pt Trend M WHR Circumference Trend Your Body Fat inteteenetrix 2010 Cancel Your Weight 170 Ibs Your BMI is within the Healthy range for a 71 in 35 year old male A healthy weight range is 131 to 151 Ibs Save To File Send by E mail Full Report Summary Report Activity Calculator IntelaMetrix 2009 22 Activity Calculator The Activity Calculator is an accurate tool for calculating a client s activity modified Basal Metabolic Rate The activity adjusted BMR is important because it gives an accurate estimate of the average number of calories a client needs to consume per day to maintain their current weight Bodyview Actmily Calculator Activities Your Activities Time Sleeping No Activity Lying dcwn totaly relaxed but not sleeping this is your basal metabolis rate cr oasal energy expenditure Very Light Sitting studying takirg itie waking or other activities Light Typing leaching leb shop work some walking Moderate Walking jogging gardening type job Heavy Heavy ma
4. it may cause problem with the software for future use Can I change a client s Athletic Type Yes you can By going to Preferences on the BodyView screen you can open the Client Profile and changes the Athletic Type Why does the waist measurement seem incorrect It is one of the few locations where there are two layers of fat The first layer is the superficial fat and the second layer in the deep adipose fat The two layers are separated by a border or interface called a fascia Sometimes the software picks the fascia instead of the actual fat muscle interface The fascia is generally the first large peak in the measurement This occurs rarely please manually override by clicking on the second large peak on the graph If you continue to have this problem you may want to change the Athletic Type of the client to the next level For example change from Athletic to Non Athletic 36 Care and Maintenance To insure the proper care and maintenance of your BodyMetrix System always remember to do the following NEVER use the device if the device or cord is broken or damaged NEVER use the device if the device is wet NEVER use the device on an open sore or cut DO NOT use abrasive or harsh chemicals to clean the device DO NOT drop the device as it may cause damage to it DO NOT store the device near a heat source or subject it to high temperatures humidity or direct sunlight as in may cause damage ALWAYS use an antiseptic
5. s CD ROM drive The following lt 3 installation window should appear NOTE Windows Vista and 7 users a dialog box may appear asking to AutoPlay the contents of the CD Please click Run autorun exe to continue Step 5 BodyMetrix driver installation Allow up to 5 minutes for the drivers to be completely installed When they have been successfully installed a check mark a rr m M Language will appear indicating the device driver is installed and the software will B1010 f A AAN Install ay prepare to install the BodyView software as shown below Jp a ca M rn ee E ee a So Step 3 Select language if option exists Click Install button to continue Note For Windows Vista or Windows 7 the installer may indicate that installation is NOT being performed as an administrator even if the user has administrator privileges If a warning message appears indicating this you CAN continue but be sure to authorize any BodyView operations ss s0 Step 6 When BodyView begins installation a separate installer window will appear as shown below Click Next to proceed and follow the instructions as appropriate When finished click Close to proceed with installation i BodyView Welcome to the BodyViewl Setup Wizard The installer will guide you through the steps required to install BodyViewl on your computer WARNING Se iain POJET or topo Cob ee ite Stee Danis ized duplication or Eee of Me program Gr a
6. wipe or cloth with 70 isopropyl alcohol in between uses Failure to do so may result in void of warranty Symbols Manufacturer Warning Contact Us If you have any problems with your BodyMetrix System please contact IntelaMetrix Support IntelaMetrix Inc 6246 Preston Ave Livermore CA 94551 USA 1 925 606 7044 support intelametrix com neran Client Index Client Name Client ID 38 Limited 1 Year Warranty The BodyMetrix System and BodyMetrix BX2000 device is warranted to be free from defects in materials and workmanship for a period of 1 year from the date of original purchase under normal use The warranty extends only to original retail purchaser For questions please call If the product becomes defective during the warranty period please contact 1 925 606 7044 IntelaMetrix Inc for repairs or replacement Or email The warranty DOES NOT cover products damaged by the following support intelametrix com Accident misuse abuse or alteration Servicing by unauthorized persons Use of unauthorized accessories Any other condition beyond our control IntelaMetr x IntelaMetrix Inc o A 6246 Preston Ave INTELAMETRIX INC SHALL NOT BE RESPONSIBLE FOR ANY INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGE RESULTING FROM THE USE OF THIS Pvernete CA ee USA PRODUCT ALL IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO www intelametrix com IMPLIED WARRANTIES OF FITNESS AND MERCHANTAB
7. ILITY ARE LIMITED IN DURATION TO 1 YEAR FROM ORIGINAL PURCHASE This warranty gives you specific legal rights and you may also have other rig that vary from state to state Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how lon an implied warranty last so the above limitations may not apply to you 39
8. System safe for pregnant women people with pacemakers or other medical conditions Yes it is safe to use on all healthy individuals Why do you use Client ID numbers instead of names Client ID numbers are used to insure the privacy of your clients Is there a significant difference in the numbers of site use or formulas for calculating Body Fat Percentage Depending on body type there can be a few percent difference between formulas used to measure Body Fat Percentage We recommend that you select one formula and use it regularly to accurately track changes How often should do assessments and scans It depends on your program but it generally takes a minimum of 4 6 weeks to see a change in Body Composition How much ultrasound gel should use For Body Fat Percentage assessments we suggest using a 1 4 inch 5 mm diameter sized amount of gel For Scans we suggest using 2 3 times that amount to effectively coat the full scan area Will the measurements change depending on how much pressure apply With normal comfortable pressures there is little effect on the measured fat thickness To study this effect go to the 2D scan and apply the BodyMetrix device to a point of interest and keep the button pressed while you change the applied pressure You should see a very small shift in the fat muscle boundary Why is the BodyView software indicating Poor Contact The most likely reason is that you didn t apply enough gel or the Bod
9. View software is indicated for the calculation of estimated total body fat percentage localized fat layer thickness and localized muscle layer thickness The BodyView software is indicated for calculating Waist to Hip Ratio WHR and Body Mass Index BMI The BodyView software is indicated for estimating Basal Metabolic Rate BMR The BodyView software can track changes in measurements and generate body composition reports Warnings amp Precautions NEVER use the device if the device or cord is broken or damaged NEVER use the device if the device is wet NEVER use the device on an open sore or cut DO NOT use abrasive or harsh chemicals to clean the device DO NOT drop the device as it may damage it DO NOT store the device near a heat source or subject to high temperatures humidity or direct sunlight as damage may be caused ALWAYS use an antiseptic wipe or cloth with 70 isopropyl alcohol to clean the contact surface of the device Installing Software Step 1 Turn on your PC Make sure you have Administrator privilege on your PC Step 4 System Check After clicking install your operating system and hardware are checked for compatibility If the system is compatible a check mark will appear STOP amp NOTE DO NOT PLUG THE BODYMETRIX as shown below and the BodyMetrix driver will begin installation DEVICE INTO THE USB PORT AT THIS TIME jele AVY Install Step 2 A Insert the BodyMetrix CD into your PC
10. age of this feature The image represents a cross sectional view through the tissue along the scan area Interfaces are found where the signal is strong The white areas in this image show the interfaces In the image below a thigh was scanned from the midpoint to near the knee cap The first bright band as indicated by the red arrow is the interface between the fat and muscle The yellow arrow points to a bright band that is the interface between muscle and bone along the thigh The muscle thickness is the distance between the fat muscle interface and the bone as shown by the blue arrow Since the scan ends near the knee the total muscle thickness decreases as the device is moved closer to the knee cap Although a good understanding of ultrasound and cross sectional imaging is an asset comparing scans is an easier process and can be used to illustrate the benefits of diet and exercise programs Depth mm Intelametrix 2008 28 Tracking Features on Scans It is possible to annotate scans and accurately measure tissue structure and thickness The screen below shows how interfaces can be automatically tracked to highlight layers on scans To annotate a feature first click on the Track Interface button and then click the mouse on the feature to be tracked on the image For example on the image below the mouse was clicked at the center on the first white feature which is the fat muscle interface The software then followed
11. are The BodyView Screen shows the client s current status If this is the first assessment for the client the values shown are an estimate based on Body Mass Index BMI and body type If not the values are from the client s last assessment or entered values This three dimensional illustration is only intended as a guide to aid the client in visualizing present body composition The user can select the desired weight and body fat percentage BF to view an approximate illustration of the client s future body image Changing the weight and BF will cause an appropriate change to the illustration Bodyview 22 7 oH Personal ID 197531 Age 35 years Gender Male Height 7 in Body Weight Ibs PRESENT FUTURE Cmreni Rty Fal 3 Body Fat 27 Body Fat 3 Fat Welght 4 lbs Fat Welght 14 Ibs Lean Weight 140 Ibs Lean Weight 136 Ibs Current EMI Fi 5 Projecied EMI GMI Value 27 9 BMI Value 20 3 Status Overweight Slains Healthy BMR 1800 4 kealiday DMR with Activity 1800 4 kealiday a Hoerercise 8 C 2 exercisesweek 2 C JA exercises weak C 5 exercises waek lt G T eeercisessveck Basal Metabolic Rate BMR is the minimum caloric requirement to maintain the client s present body weight A user can select an activity level by clicking on the appropriate button Clicking the question mark icon displays helpful information for each category Clicking on the rotation icon at the bottom
12. cumference Measurements To view the value of each data point simply place the mouse cursor over the data point and the value will appear Bodyview 20 7 Be Personal ID I975M31 Age 35years Gender Male Your Weight Your Body Fat CIRCUMFERENCE show Date IntelaMetria 2008 The actual value generated for each data point on the line chart can be shown by checking the box Show Values If you click Show Data a table is displayed that shows the measured values in a spreadsheet format which can be Printed Saved to a File or Emailed 24 BodyLive Importing Photos BodyLive allows the user to maintain a photo gallery of client images Real before and after pictures can be imported from the hard drive or a digital camera To import photos click Import Photo Select the photo to import An Import Wizard will open up you can crop the photo using your mouse Bodyview 22 7 Ciba Personal ID 975M31 Age J5years Gender Male Import Photo Print Report BPRS 1 Se 27 Photo Galery Weight Ibs BF 0 0 Weight Ibs DF 0 0 Weight Ibs BF inielaMeiria 2005 When importing a photo select the region of the photo to import by pressing the mouse button and dragging the mouse to define the crop rectangle NOTE the aspect ratio of the crop rectangle is fixed it may be necessary to try different starting points to get the desired photo area When satisfied click on Save Photo to add the new photo to the Ph
13. e performed by clicking on the Single Point button A dialog box will appear that leads the user through a measurement To begin measuring body fat percentage click the Measure BF button and the 16 Measurement Wizard will appear Measurement Sites are shown on Page 32 of this User s Guide NOTE In the Advanced mode the Wizard is disabled and the user can simply select any point by clicking on it in the Points List and then performing the measurement as described below We recommend that everyone starts in the beginner mode The Wizard is intended to guide the user in properly placing and measuring each site The 3D graphic to the right of the Measure screen shows the user where to place the device The Wizard also describes device placement for each Measurement Site In Wizard mode 2 3 measurements will be taken per site for a more accurate result Please follow these steps to take the measurements Step 1 Clean the device with an antiseptic wipe or cloth with 70 isopropyl alcohol before starting a new assessment Step 2 Apply a pencil eraser sized amount of ultrasound gel to the device NOTE You may be necessary to apply more gel during the assessment Step 3 Place the device on the measurement site and press the button for 3 5 47x seconds The Red light should illuminate During this time slide the BodyMetrix device about 1 4 of an inch to either side of the start position Slide the device slo
14. ealthy fat fat free mass and estimated body water Relative Disease Risk shows the risk for heart disease stroke and diabetes based on the client s body fat percentage and BMI My Health also offers a healthy weight range and recommendations to achieve or maintain a healthy weight and body fat percentage 94 om Generating Reports A report for a client can be generated by clicking Full Report or Summary Report The Full Report breaks down all the information in a detailed 3 page report The Summary Report is a single page report that includes the results of the last measurement Both of these reports can be Saved to File Printed or Emailed directly to the client To email reports make sure you have an email program such as Outlook configured and working Alternatively you can configure the email options directly in by using the Administrator options or Preferences The reports can also be customized to include the User s logo or health recommendations For information on customizing reports see Page 31 of this User s Guide When printing the Full Report you have a choice of options allowing you to select which measurements and sections to include in the report Bodyvjew 2D oK Summary Bodyv ew Name John Will Date 7 23 2010 Plametrix 2010 Bodyview Report Your percent body fat is 27 af Please select sections you want to print and click Print button M Fat Percent a i
15. g vertically 3 4 inches towards the knee 33 Tricep Locate the site midway between the acromion tip of the shoulder and the elbow To Scan place on the midpoint press and hold the device measurement button while slowing sliding vertically 3 4 inches down towards the elbow Lower Back Locate the site over the kidneys and 2 inches to the right of the spine To Scan place on site Press and hold the device measurement button while slowly sliding horizontally to the right 3 4 inches towards the hip Calf Inside midline of calf muscle at the maximum circumference of the calf To Scan place on the site Press and hold the device measurement button while slowly sliding vertically 2 3 inches down towards the ankle Chest MALE Locate the site midway between the anterior axillary line under arm and the nipple To Scan place on the axillary line Press and hold the device measurement button while slowly sliding vertically 3 4 inches towards the nipple Chest FEMALE Locate the site 1 3 the distance between the anterior axillary line under arm and the nipple 34 FAQ s What if my device is damaged and or the device or software is not working Please contact IntelaMetrix Support at 925 606 7044 or support intelametrix com Is the BodyMetrix System safe for children Yes it is safe for use on children However it is intended to be used on children 6 years or older Is the BodyMetrix
16. he client is John Smith just enter Smith in the last name and the software will display all Clients with the last name of Smith To open the client s profile click on et the Client ID and click Open or simply double click on the Client ID OPEN ie Demonstration Mode Demonstration Mode is a Home Screen option that can be used for quick assessments without creating clients This is great feature when using the BodyMetrix System at fitness fairs community events or for prospective members and clients When you select Demonstration Mode the following BodyView screen appears Bodyview 2p 7 OA il Gender h d j Macias l AAT ii Age EN f Mal C Female Haight g in i ron Bady Viaing hil i 9 las Fat Weight 1 lbs Fat Welghet Laan Wirighi 1 Whos Laisar Wiigi Current BMI 7 Projected BMI BMI Value BMI Value 2 Siabus tiny 7 Siailus Your OGMR BMR DMR with Activity i PREFERENCES magts y D E ord cece yA AN AMATOS va 7 007 bvtelaMetria 2009 At this point you can select the gender of the client and adjust the weight height and age The Athletic Type is set on the Measure page you should use the same criteria as described in the new client section 14 BodyView Once a profile is created or opened the BodyView Screen will appear as shown below A series of tabs across the top of the screen allow the assessor to navigate through the different features of the softw
17. if you ve ever heard an echo you re a long way to understanding the graph and how the BodyMetrix System uses ultrasound to measure tissue thickness You hear an echo when sound travels through air and reflects from a wall or mountain and comes back to your ear If you time how long it takes for you to hear the echo you can calculate how far away the reflecting object is The BodyMetrix System generates an ultrasound signal that travels through tissue and then records the reflected signal Continuing the echo analogy the BodyMetrix device plays the role of your mouth and your ear Ultrasound waves travel in tissue and strong reflections occur at the boundary of different tissue types for example fat muscle and muscle bone Measurement Data 0 4 8 12 16 2 24 32 36 40 44 48 52 56 6l Thickness mm Intelametrix 2003 The graph above shows a typical measurement The horizontal axis corresponds to the thickness or depth of tissue and the vertical axis is the reflected signal The first peak is the fat muscle boundary The smaller peaks are different structure which can include connective tissues in the muscle layer The third peak is the muscle bone border It s important to note that the BodyMetrix measures the true tissue thickness unlike calipers which measure a skin fold thickness which can be anywhere from 1 to 3 times the true fat thickness 19 Recording Circumference Measurements You ca
18. left of the Present Model will rotate the illustration Clicking the icon again will stop rotation The Preferences button allows settings and client information to be changed 15 Measuring Body Fat Percentage To measure the body fat percentage click on the Measure tab NOTE The first time you use the BodyMetrix System the software will prompt you to calibrate the device Simply press and hold the button for a few seconds to complete the calibration process Bodyview 2p ona Personal ID 1975M37 Age 35 years Gender Male LOCATION OF FROBE Currant formula used Polnt 3 sites by Jackson amp Pollock W Thigh Chest Your Body Fat Not Enough Data Waist Current Welght 170 Sf lbs Bohman Device Single Polnt eviit stalls F Ready Measure BF Measurement Data Circumference Measurements Titcdinnes men Your Waist to Hip Ratio WHR Please enter your Hip and Waisi clrcumlerences to calculate WHE aisan 210 To make a measurement you must first select a formula to use In most cases the default 3 point formula is a good option For more accurate assessments formulas with more points can be used Simply use the drop down menu as shown above to select the desired formula The number of available formulas depend on gender and age New formulas can be added upon request The anatomical points used are identical to those used when making skinfold caliper measurements A single point measurement can b
19. n also record and track circumference measurements and Waist to Hip ratio WHR Use the tape measure provided with the BodyMetrix System to accurately make circumference measurements To record these measurements simply select the point and type in the measured value Alternatively double click on the desired point and enter the results in the dialog box and Click OK OR simply select the point and type the value directly into the table Bodyview 2p 7 Oe Personal ID 1975M371 Age 35 years Gender Male Points List LOCATION OF PROBE Current formula used Point 3 sites by Jackson amp Pollock Wi Thigh WJ Chest Your Body Fat 24 2 Waist Current Welght 200 fibs Bodymetniog Devica Single Paint Bodyview Device stalls F Ready Please enter Tape Measurement in Measurement Data Cancel T T T T 1 1 T 1 8 412 i 2 2 2 3 4 49 48 82 mf BO Ties fenn E Haner Bg Your Walst to Hip Ratio WHR Please enter your Hip and Waist clrcumlerences to calculate WHIL iaiia 210 J IntelaMetria 2008 You can record and track the following circumference locations Neck Chest Bicep Thigh Waist Hip Calf Once the Waist and Hip circumferences are recorded the software will automatically calculate the Waist to Hip ratio and show the value on the scale The scale categories are based on World Health Organization WHO guidelines 90 My Health The My Health screen communicates the resul
20. n the shoulder and the elbow joint on the front of the upper arm or at the peak of the bicep The arm should hang freely and relaxed on the side of the subject To Scan place at midpoint press and hold the device measurement button while slowing sliding vertically down 3 4 inches towards the elbow Scapula Locate just below the bottom tip of the scapula shoulder blade To Scan place on the bottom tip of the scapula Press 7 and hold the device measurement button while slowly sliding horizontally 3 4 inches to the right Axilla Locate the site on the midaxillary line below the armpit level with the bottom of the sternum or breastbone measurement button while slowly sliding vertically 3 4 inches towards the hip wa 2002 Waist Locate 1 inch lateral to the umbilicus belly button To Scan place on the waist site Press and hold the device measurement button while slowly sliding horizontally right 3 4 inches towards the hip Hip Suprailic Locate the site just above the iliac crest front side tip of the top of the hip bone To Scan place 1 inch below the iliac crest Press and hold the device measurement button while slowly sliding horizontally to the right 3 4 inches Thigh Locate the anterior midline of the thigh front thigh midway between the patella knee and the crease of the hip To Scan place on the midpoint press and hold the device measurement button while slowing slidin
21. ng Body Fat Percentage cccccecsecseceeseeeeceeteeeeseeceeseesesaees 16 Analyzing Body Fat Assessments cscceeceeceeteeteeteeeeeeeeeeeeeeees 19 Recording Circumference MeasureMenttS ccceceeceeeeeeeeeeeeeeeees 20 My LOGI Uhl onair ar a a a e 21 Generatine REPOLLO are ae a aaa a la a TAEA 22 Activity Calcula lOr cera ea ices 23 Trends and Reviewing PrOgreSs cccscceeseceeceeceeseceeceeseeeeceeseesesaees 24 BodyLive Importing Photos ccccecceceeceeceeeeeeeceeseeeeseeeeaeeeesaees 25 ZI BOdV SCANS na tocs he AO eee cete iene ae RNs aici ache 26 IMEC FORGING SCANS arna a r N 28 Tracking Features ON SCaN Sassan ae a 29 C mpanne SCANS senna n A aee 30 C stomizing Repor Seain a a a a e 31 Measurement Site and Scan Point Guide cceceeceeceeceeeeeeeeeetenes 32 FAQ Sanana aa aaa eaaeoa dave leas dew dan aacndeaeaneatadine os daoataes 35 Care and Maintenance sssi irre ata a eae oot 37 Client ae Ce co ete i a aa 38 Limited 1 Year Warranty xccecctiwncdicosndetucedosttiseuncbteestanehecomsaotiGrnnceoces 39 Indications for Use 1 The BodyMetrix BX2000 is indicated for the measurement of localized fat layer thickness and localized muscle layer thickness When used with BodyView software it can be used to estimate total body fat percentage The BX2000 is only intended to be used on generally healthy adults and children 6 or older and is not for diagnosis of a disease or condition 2 The Body
22. ny parton OF ey Fes I Severe CHE or criminal penalties and will be prosecuted to the maximum extent possible under the law Step 7 When the installer is finished you should now see a check mark on the BodyView Software Successfully Installed as shown below Operating System Compatible BodyMetrix Driver Successfully Installed BodyView Software Successfully Installed Step 8 After the BodyView software has been installed the installer will ask you to PLEASE PLUG THE DEVICE INTO THE USB PORT as shown below After plugging in the device it may take up to 5 minutes for the device to connect Step 9 Once the driver and device have connected the Green light on the device should be illuminated as shown Step 10 Test BodyMetrix Device When asked as shown below press the measure button on the device for 1 2 seconds comm OAS NTS tT I If the device functions correctly installation is complete and the installer screen will appear with four check marks Click Finish to end the installation If you have experienced any installation issues please contact IntelaMetrix support 8 Using the BodyMetrix System Starting BodyView Software Before starting the BodyView software make sure the BodyMetrix is plugged into the USB port as described in the previous section The Green light should be on to indicate the device is connected Now double click on the BodyView icon on your desktop to launch the softwa
23. odyview 22 Create New Client s Profile a 7234000 gt athletic EA DE iss Bis Enter all the client information including First Name Last Name Email Address Date of Birth Gender Athletic Type see below Height Current Weight and Group ID see below Click Start to continue Athletic Type Non Athletic Anyone who is visibly overweight and rarely exercises Athletic Anyone who appears in good shape and exercises regularly Elite Anyone who is in excellent shape and exercises frequently e g body builders professional athletes etc Group ID Group ID is aname or number that you can assign to group clients together so you can track group statistics It could be part of boot camp or a trainer s ID number You can review a Group Summary in the Administrator options After you click Start a dialog box will appear asking for a client password If you do not want to password protect the data simply leave it blank and click OK Once you click OK you will be directed to the BodyView Screen 12 Opening Client s Profile To open an existing client s profile click Open Client s Profile in the Home Screen Bodyview 2p Open Client s Profile Chen List Search SN AMTS v4 7 10071 IntelaMetria 2008 You can search by Client ID First Name or Last Name You do not have to enter the entire name or Client ID to search for the client For example if t
24. oto Gallery panel To compare photos click and drag the photos into the desired display panel box NOTE the weight and BF on the day that the photo was imported is displayed at the bottom of the photo To display correct values insure that photos are imported the day measurements are collected To delete a photo just click on the photo and press the Delete key To print photos in the display panels click Print Report The options are to Save to File or to Email the photos directly to the client 25 Body Scans The BodyMetrix System can also be used to capture cross sectional images of specific areas of interest This feature can be used to accurately track fat loss muscle gain and even distinguish muscle quality Bodyview 2p D OB Scan Point Measurencnt Thigh Intensity 180 Tissue Cross Section Personal ID 1975M31 Age 35 years Gender Male Measurement Data ol 4 ll Ta 1E SO O E g g g a A Oepld imm D indelametroc A Maximum Depth 600mm Track Interface Boeymetix Device Device status P Ready Save Imaga Compare Images d hiela Meiris 2005 r To perform a scan follow these directions Step 1 Clean the device with an antiseptic wipe or cloth with 70 isopropyl alcohol before starting a new scan Step 2 Using the drop down menu select a Scan Point to scan Suggested Scan Points are shown on Page 32 of this User s Guide 26 Step 3 Apply a dime sized amount of
25. portof the selected scans click Print Report The report can be Saved to File Emailed or Printed out Bodyview X Sect Compare Print Report Cancel v v Bicep 20090520 2 26 22 PM Bicep 20090523 1 54 44 PM Measurement Saved Images Waist 5 27 2009 Tricep 5 28 2009 Tricep 5 28 2009 Tricep 5 28 2009 Thigh 6 17 2009 Thigh 6 17 2009 Thigh 5 29 2009 Thigh 2 6 2009 30 Customizing Reports All reports generated by the BodyMetrix can be customized To do this go to Program Files gt Open the folder ntelaMetrix gt Open the folder BodyView gt Open the folder Rpt Multiple Rich Text Format or RTF files are in the folder which can be modified We recommend that a backup copy is saved before any modifications are made When a report is opened a combination of normal text and tag fields as shown below will be displayed A tag field e g EPERSONAL FIRSTNAME consists of a followed by an identifier and a closing and represents a value or graph that will be inserted into the report by the BodyView software Edit the report as desired being careful to correctly format tag fields Multiple report rtf files can be generated by simply saving them as RTF files with a new file name that includes the word Report in the file name If multiple reports are available the software will allow the user to select which report to generate This feature allows reports to be designed for different groups Upon comple
26. re The Home Screen will appear Bodyvjew 2p imelaMerix 2009 The Home Screen allows the user to Create New Client Profiles Open Existing Client Profiles and enter the Demonstration Mode which can be used to make quick measurements without adding a client to the database In addition from the Home Screen the Administrator can control software options and manage the client database Administrator To access the Administrator options click on the Administrator label on the bottom left hand side of the Home Screen Bodyview Security A dialog box will appear asking for a password The password can be changed once you have gained access The default password is 123 ye C In the Administrator General options tab you can change from US to Metric Units change the Measuring Mode from Beginner to Advanced enable touch screen select different skins to change the color scheme and setup Email Options To setup Email Options enter your outgoing SMTP server settings your email login ID and password If you use Microsoft Outlook you can bypass this step as the software will use your default email system You can also change the default password by clicking Change Administrator Password and enter a new password BodyView Administrator Options Measuring Units Measuring Mode Choose measuring units for Demo Mode Choose Measuring Mode US Lbs Inches Beginner Mode C Me
27. rua labor such as digging tree felling climbing Irtelarretrix 2009 Exceptionally Heavy itness oriented cycling or siniler vigorous activities weight traning aerobic dence Time View Calories View Sports Vigorous sports ccmpettion such as focthall racquetball tennis or other extencec play spons activities All Out Training Your BMR 2572 8 kcal day Cxtremey high intensty weight training with litle rest between seis or exerc ses Extended Maximum Effort Exiremey high intensty and high duration sports competition such as triathor cross country sking or marathon To use the Activity Calculator enter the number of hours per week the client devotes to each activity Note that the calculator automatically modifies the No Activity number of hours to add up to a complete week The breakdown of activites can be viewed by time or by calories burned The calculator uses the Katch McArdle formula which estimates the metabolic rate by using only lean mass For this reason it is important that an accurate body composition assessment is performed before using the Activity Calculator M e i Trends and Reviewing Progress The Trends screen allows the user to show the client the progress being made with a particular program In Trends all the recorded data is portrayed on a line graph You can chart the following data Weight Body Fat Point Specific Fat Thickness Waist to Hip Ratio Point Specific Cir
28. that feature to produce the first red track showing fat thickness If satisfied with the track results click Stop Tracking If unsatisfied click the mouse on other sections of the feature to force the automatic tracking to go through each click points It is possible to track multiple interfaces to measure tissue thickness For example to measure muscle thickness you can track the muscle bone interface as shown below To save the scan click the Save Image button when satisfied with the scan and tracked features To remove the last track simply click Clear Track Tissue Cross Section intelametrix 2009 Track Interface Clear Track Compare Images To compare saved scans click the Compare Images button 29 Comparing Scans To compare any two saved scans simply drag the desired Saved Image to the display panel If the scan was saved with tracks then they will also be displayed To remove the tracks from a scan uncheck the Show Tracks check box To enlarge an area on a scan click on the Zoom In icon and then click inside the scan at the point to be enlarged To return to the normal view simply click on the Zoom Out icon To measure the thickness of a tissue layer click on a start point and drag the mouse to an end point The measured thickness will be displayed in the measurement panel directly below the scan To delete a scan select the scan to be deleted and click Delete on your keyboard To print a re
29. tion of any changes or customization save the RTF file and exit The next time BodyView is opened the new report will be in place 3 gn a Phone renee Peg Layout Hefenences Mailings LEDE Wesi add in PO ohange 4 al i HE ps s reparti Compabbilly Model Merocoll Word b a Century Gothic sja AC GS aT AaBbCeL AnbbCel AaBht AaBbt gt AA oe rate F fees Den r 2 A E oe Namal TMs Spaci_ Heading Titir ireli a sea CHoboard Ford Faragrepn m Siytes Eating TM Bodyview Name FPERSONAL FIRSTNAME FFERSONAL LASTNAME Group ID FSROUP ID Bate CUR DATE SHORT MY HEALTH Tour EMI iy within the CUR_BMISTATUS renge fore PCUR_HEIGHT H U FAGE yec old GENDER 4 healPhy welaht rangi i FHEALTHY_WEIGHT_LQ 1o FHEALTHY_WENGHT_HI 6 U While Bhilalsne ngt the bes mec of heal li canave yous genem ldeo of ysurheoalih However these ore Hondom noma thetde nettake inte corndderction actual booty competion which is o beter mesure ol health Fer enamels a wall condilioned mutcular athlete could fall wifin ne ovenveight catego bared on ihe danit af nice mam nthe other hand on Inehvicel within ihs nemal range of inners noma mighibs overnvelghl archers wilh on neceissve Omer 2 body fot Fagg loa Words ari Ergugr fues4 O41 Measurement Site and Scan Point Guide Male amp Female Bicep Locate the anterior midline of the upper arm halfway betwee
30. tric Kg Cm C Advanced Mode Miscellancous Skin Management Choose a skin from the list Classic Touch screen enabled Email Options _ Change Administrator Password New Software Key GENERAL CLIENT MANAGER 10 Unlocking Software You may need to enter a software key to completely unlock your software A trial counter will appear on the upper left hand side of the screen if a valid software key is required The BodyView software is locked and will only allow a limited number of uses before asking for a software key To unlock your version of the software click New Software Key A dialog box will appear asking you to enter a 54 character key Your 54 character key is stored in your CD or it is printed on the CD case or sleeve that came with your BodyMetrix System Once the software key is entered and validated you will have unlimited access to the software Client Manager If you click on the Client Manager tab you can import client data delete clients from the database and generate a group summary of data on all your clients or a specific client Group ID To learn more about Group ID please see the next page of this User s Guide BodyView Administrator Options Clients List Import Client s Profile s Group Summary Delete Client GENERAL 44s Creating a New Client To create a new client begin by clicking Create New Client on the Home Screen The following screen will appear B
31. ts of the measurements to your client It provides a detailed look at total body fat percentage BMI BMR and relative disease risk It advises clients on how to improve or maintain their present health status Bodyview 2p Personal ID 1975M37 Age 35 years Gender Male summary Your Body Far Height 71 in Body Weight 170 Ibs Your Body Fat tig 27 btelamelin 2010 Fal Weight 46 Ibs Yi BMI Lean Welght 7 4 Ibs Our wa es Fonmuala Your BMI is 73 7 3 sltes by Jackson amp Pollock Your Weight DMI Value 23 7 BMI Status Hevslilyy Eotess Fat 18 Ibe 11 Yoo AMR Healthy Fat BMH 1545 0 kcaliday 2 be 16 Fed Free Relies HMR with JIS Bo 2 Activity 1505 20 kealiday kisama 2010 T Noexercise 5 enercisesAvenk Your Healthy Weight Range 131 151 Ibs F 0 J exercisestweck Recommendations Your weight and body composition ara above the recommended lewal for maintaining optimal health Losing T9 lbs ol bady lal or reducing your body lal p rcemage by 4 would place you in Sexercisesweek the healthy category and would substantially reduce your risk of disease Including coronary 4 6 7 exercisessweak heart diagase and stroke Full Report Summary Report Activity Calculator InielaMetria 2005 The Body Fat and BMI classifications shown on each scale is based on WHO recommendations guidelines The Your Weight pie chart shows how the weight is distributed between excess fat h
32. wly to avoid losing contact with the skin Sliding during the measurement averages the fat thickness being measured over the scan area Please watch the training video to see the recommended technique Measurement Wizard The measured Fat thickness for the Step 4 Thigh is 7 1 mm After each point is measured the l Repeat measurement Measurement Wizard will ask whether you would like to repeat the measurement Click No unless an error was made Bodyvjew 2D F Home O Bodyview Measure Personal ID 1975M31 Age 35years Gender Male LOCATION OF PROBE Current formula used Point 3 sites by Jackson amp Pollock Thigh Chest Your Body Fat 24 2 OQWaist Current Weight Ibs Bodymetrix Device Sing Measurement Wizard Device status J Measuring 1 a Measurements completed Your BF is 24 2 Your Lean Body Mass is 146 Ibs 75 8 Your Fat Mass is 54 Ibs 24 2 O 4 8 12 16 20 24 28 32 3 40 44 48 62 66 60 Thickness mm Intelametrix 2010 Your Waist to Hip Ratio WHR Please enter your Hip and Waist circumferences to calculate WHR Intelametrix 2010 Step 5 After all measurements are complete the software will generate a Total Body Fat Percentage Click OK to continue Step 6 After completing the assessment clean the device to eliminate any gel 18 Analyzing Body Fat Assessments The measurement graph displayed on the Measure Screen may look intimidating but
33. yMetrix was at an angle on the skin not making full contact with the skin Also when sliding the device to average it is important to maintain good contact with the skin Do NOT be afraid to apply a little pressure 35 Can I add new measurement sites to the BodyView software to measure Yes you can easily do that by clicking on the 3D figure to the right of the Measurement screen A dialog box will appear asking you to name the new site Can I override fat thickness measurements Yes you can If the automatic fat thickness measured is clearly in error you can override the automatic calculation by stopping the measurement and clicking on the appropriate peak on the Measurement data graph Select the peak you believe is the correct fat muscle border interface A dialog box will appear asking you to confirm This should rarely be necessary but in some cases clients may have scar tissue within the fat layer that can hide the correct fat muscle interface How is Basal Metabolic Rate BMR calculated We use the Katch McCradle formula to calculate BMR How do I backup my database If you perform regular backups of all your documents then the database should automatically be saved However if you want to directly back up the database you need to navigate to the folder C Documents and Settings All Users Application Data Intelametrix and copy the folder BV to your backup storage media DO NOT move or tamper with the database file as