OPERATING INSTRUCTIONS MANUAL

image

Contents

1. BURNER S 406 FLAME ROD S 1007 FLAME ROD WIRE l a _ NENNEN NENNEN NENNEN NENNEN FLAMERODWIRE _______ 54 o ooo S o 10 _ S 00 S410 HIGHTEMPERATURELMT oo S 0 san JOFFRUNSTARTSWTOH oo o Sa JMANREAY ooo o 644 o 8488 POTTED IGNITION CONTROL 120V2002TOPRESENT sat THERMOSTAT _____ S105 SOREENASSEMBLY ooo S 6400 OLEARINDICDATOR LIGHT REDINDICATOR LIGHT S102 GREENINDICATORLIGHT ooo ooo POWERCORDINGLUDINGPLUG o O o o o S o 5 1021 POWER CORD INCLUDING PLUG 5 1022 RUBBER WHEEL 8
2. CIES ONLY ALWAYS PROVIDE ADEQUATE VENTILATION 1 SQ IN OF FRESH AIR MUST BE SUPPLIED FOR EVERY 1000 BTUH OF HEAT THIS HEATER SHALL BE INSTALLED SUCH THAT IT IS NOT DIRECTLY EXPOSED TO WATER SPRAY RAIN AND OR DRIPPING WATER This heater is designed and approved for use as a construction heater under ANSI 283 7 2000 and CSA 2 14 2000 Gas Fired Construction Heaters We cannot anticipate every use which may be made of our heaters CHECK WITH YOU LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about these SPECIFICATIONS Model Number F 1500T Input 650 000 to 1 500 000 btuh Fuel Natural Gas or Propane Inlet Pressure Natural Gas 9 0 W C Propane 11 W C Ignition Direct Spark Ignition Thermostat Control Air Circulation 7000 cfm Fuel Consumption 69 Ibs hr 1428 cfh Approved cULus listed INSTALLATION The installation of this heater for use with natural gas shall conform with local codes or in the absence of codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 and the Natural Gas and Propane Installation Code CSA B149 1 The installation of this heater for use with propane tank or cylinder shall conform with Local codes or in the absence of local codes with the Standard for the Storage and Handling of Liquefied Petroleum Gases ANS
3. I NFPA 58 and the Natural Gas and Propane Installation Code CSA B149 This heater must be located at least 10ft 3m from any propane gas cylinder This heater shall not be directed toward any propane gas container within 20ft 6m CLEARANCE TO COMBUSTIBLES F 1500T TOP 4 ft FRONT 22ft _ SIDES 2ft REAR 2ft CONNECTING THE CYLINDER If cylinders are used to supply the heater no cylinders smaller than 100lb capacity shall be used These cylinders must supply a vapor withdrawal only 16 All cylinder connections must be made using a wrench to tighten the POL fitting 2 Be sure that the cylinder valve is in the closed position when connection or disconnecting the cylinder 3 A soap and water solution must be applied to all connections in order to leak check the system The gas must be turned off at the propane supply cylinder s when the heater is not in use When the heater is to be stored indoors the connection between the propane Supply cylinder s and the heater must be disconnected and the cylinders removed from the heater and stored in accordance with Standard for the Storage and Handling or Liquefied Petroleum Gases ANSI NFPA 58 and CSA B149 1 Natural Gas and Propane Installation Code PIPING This heater must be installed by a qualified gas technician following local codes published by the authority having jurisdiction Sizing of Supply piping must be determined using the length of pipe run as well as total btuh rati
4. Light Indicator S 1020B Green Light Indicator S 1020C On Off Start Switch S 411 Power Cord inc plug 5 1021 Thermostat S 416 Main Relay S 412 Air Proving Switch S 414 Potted Ignition Control S 415P Rubber Wheel 8 S 1022 Screen Assembly S 1019 1 H P Motor S 100 Long Reach Igniter S 408A Flame Rod S 406 Fan Blade 5 1001 Burner 93 1505 1 1 4 15FT Hose 554180 20 1 1 4 Second Stage Regulator B31R 125 201 F 1500T WIRING DIAGRAM 2010 CLEAR LIGHT ce ON OFF HIGH LIMIT RELAY L1 0 ox Jen ORT UE FAN MOTOR L2 C C RED LIGHT GROUND e MOMENTARY 4 COIL THERMOSTAT err AIR SWITCH r 5 FLAME ROD GROUND GREEN LIGHT NN OC oOo O O V1 L1 V2 L2 81 GND x m UR p 2 2 m O E SPARK PLUG BLUE BLACK ORANGE FENWAL IGNITION BOARD IGN MODULATING GAS VALVE POTTED CONTROL SOLENOID VALVE Note If any of the origional wire as supplied with the appliance must be replaced it must be replaced with type 14g TEW wire or its equivalent FLAGRO INDUSTRIES LIMITED TITLE F 1500T WIRING DIAGRAM 2010 DWG NO 1500 20 PARTS LIST FOR F 1500T Part Number 5 1000 5 100 5 1004
5. OPERATING INSTRUCTIONS MANUAL Please retain for future reference For F 1500T DUAL FUEL CONSTRUCTION HEATER ve P a 1 E _ CERTIFIED FOR USE IN CANADA AND U S A As per Standard ANSI Z83 7 2000 CSA 2 14 2000 Gas Fired Construction Heaters Unvented Unattended Type c UL us LISTED FLAGRO INDUSTRIES LIMITED ST CATHARNIES ONTARIO CANADA GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER CAN RESULT IN DEATH SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOXIDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUILDING MATERIALS PAPER OR CARDBOARD A SAFE DISTANCE AWAY FROM THE HEATER AS RECOMMENDED BY THE INSTRUCTIONS NEVER USE THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNER DUST PARTICLES OR UNKNOWN CHEMICALS WARNING NOT FOR HOME OR RECREATIONAL VEHICLE USE WARNING INTENDED USE IS PRIMARILY THE TEMPORARY HEATING OF BUILDINGS UNDER CONSTRUCTION ALTERATION REPAIR OR EMERGEN
6. are present use volt meter Ensure ignition board is properly grounded Thermostat Ensure the thermostat is calling for heat PROBLEM HEATER WILL NOT REMAIN LIT AFTER START UP POSSIBLE CAUSE Faulty flamerod wire REMEDY Check flamerod wire for any damage Ensure connections are secure Replace flamerod if necessary F 1500T Parts List LIMITED i HECHOS i 4 E a a E F 1500T Parts List LIMITED VALVE TRAIN m He imc p LIMITED if M ON th i flagro INDUSTRIES M A W i 1 MAUI MA M I AAA Ag dV A hy E FU SS HIGH FIRE 1 LOW FIRE NA u 2 u 9 4 t F 1500T Parts List GAS FIRED ANS 283 7 CSA 2 14 700 CONSTRUCTION US RADITEUR DE C NTROL N LISTED LAGRO INDUSTRIES LIMITED fO LIMITED F 1500T Parts List 1 A 9 Item Description P N INDUSTRIES 1 1 4 X 3 1 2 Nipple 40 113G3 5 40 104 20 1 1 4 X 90 BM Street Elbow 40 116 20 1 1 4 X 5 1 2 Nipple 40 113G5 5 Fuel Shut Off Valve S 1003A Fuel Selector Valve S 1003 40 113G11 1 1 4 X 90 BM Street Elbow type 3 40 116 20 1 1 4 X 4 1 2 Nipple 40 113G4 5 Pipe Hanger S 1031 Solenoid S 1004 1 1 4 X 7 Nipple 40 113G7 Regulator S 1052 1 1 4 X 2 Nipple 40 113G2 1 1 4 Coupling 40 103 20 Clear Light Indicator S 1020A Red
7. is operating 2 Move the main switch to the OFF position 3 Disconnect the heater from gas supply F 1500T TROUBLESHOOTING ANALYSIS PROBLEM POSSIBLE CAUSE REMEDY POSSIBLE CAUSE REMEDY POSSIBLE CAUSE REMEDY POSSIBLE CAUSE REMEDY HEATER WILL NOT LIGHT Air switch improperly set Use centre adjusting screw to set air switch Turn clockwise to increase sensitivity turn counter clockwise to decrease sensitivity Blockage in copper inlet tubes Disconnect tubes from air switch Use high pressure air to clean any debris that my block the airflow Faulty Switch Replace Switch Rear of heater blocked Ensure rear of heater is unobstructed and proper rear clearances are maintained see approval label POSSIBLE CAUSE REMEDY POSSIBLE CAUSE REMEDY POSSIBLE CAUSE REMEDY POSSIBLE CAUSE REMEDY POSSIBLE CAUSE REMEDY Faulty Solenoid Ensure solenoid is energized use volt meter Ensure plunger in the solenoid is being activated use manometer at test point after solenoid use volt meter Incorrect Gas Supply Ensure required gas supply pressures are supplied to the heater see approval label Spark Plug Ensure gap in spark plug is approx 1 8 Check spark plug wire connections Ensure spark plug has good spark Replace spark plug if necessary Ignition Board Ensure electrical signals for both spark plug and solenoid
8. ng of the appliance s Appropriate piping tables must be used to determine size of supply piping dependant on the length of run from source PRESSURES MAXIMUM INLET PRESSURES LP 14 0 IN WC NG 14 0 IN WC MINIMUM INLET PRESSURES LP 11 0 IN WC NG 9 0 IN WC This heater must be supplied by pressures indicated on the approval label Over pressure may cause controls to fail DO NOT supply this unit with more than 1 2 psig 14 0 W C Note A second stage regulator must be installed if the supply pressure exceeds 1 2 psig FUEL This heater will operate on propane or natural gas The manifold pressures are listed on the approval label Ensure that the proper pressure settings are achieved depending on the fuel being used A fuel selector valve is located on the manifold of the heater Ensure that this valve is in the proper position depending on the fuel being used DO NOT operate the heater with the valve in the incorrect position HOSES All hoses used to connect this heater of fuel supply must be Type 1 approved propane natural gas hose assemblies ELECTRICAL WARNING Electrical Grounding Instructions This appliance is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle 120v supply must be available Please note that the motor on this unit requires 20 amps Ensure appropriate gauge extension c
9. ord is used MAINTENANCE 1 Every construction heater should be inspected before each use and at least annually by a qualified service person The hose assembly shall be visually inspected prior to each use of the heater If it is evident there is excessive abrasion or wear or the hose is cut it must be replaced prior to the heater being put into operation The replacement hose assembly shall be that specified by the manufacturer The appliance must be kept clear and free from combustible materials gasoline and other flammable vapors and liquids The flow of combustion and ventilation air must not be obstructed Be sure to check the fan assembly and ensure that the motor and blade are operating properly Compressed air should be used to keep components free of dust and dirt build up Note Do not use the compressed air inside any piping or regulator components F 1500T START UP INSTRUCTIONS 1 Set fuel selector valve according to gas supply to be used 2 Connect construction heater to gas supply with approved hose assembly 3 Plug the electrical cord into a 20 amp supply 4 Open all gas supply valves 5 Depress the main switch to the START position The fan will start and the burner should ignite 6 Set the Thermostat to the desired temperature 7 f heater fails to ignite after 3 attempts call your supplier for service TO SHUT DOWN 1 Close the main gas supply valve while the heater