Installation and Operating Instructions
Contents
1. _ No water or too low water level in well Check valve is stuck in it s closed position Pull the pump and clean or replace the valve _ The suction strainer is closed The pump is defective 3 The pump runs at reduced a The drawdown is larger than anticipated Increase the installation depth of the pump throttle the pump Capacity or replace it with a smaller capacity model b The valve s in the discharge pipe are partly closed blocked c The discharge pipe is partly chocked by Clean replace the discharge pipe impurities Iron bacteria d The non return valve of the pump is blocked by impurities Iron bacteria necessary Clean the pipes 4 Frequent starts and stops a The differential of the pressure switch Increase the differential However the stop pressure must between the start and stop pressures is too not exceed the operating pressure of the pressure tank and small the start pressure should be high enough to ensure sufficient water supply b The water level electrodes or level switches Adjust the intervals of the electrodes level switches to ensure in the reservior have not been installed Suitable time between the cutting in and cutting out of the correctly pump See installation and operating instructions for the automatic devices used If the intervals between start stop cannot be changed via the automatics the pump capacity may be reduced by throttling the discharge valve c Checkvalve is leaking or stuck hal
2. especially in 3 wells NOTE Do not lower or lift the pump using the motor cable 5 When the pump has been installed to the required depth the installation should be finished by means of a well seal Note that the dynamic water level should always be above the pump 6 Loosen the safety wire so that it becomes unloaded and lock it to the well seal using a cable clamp 7 Attach the supplemental information label at the electrical installation site 8 Complete the electrical connections Remember that a capacitor or a control box should NEVER be connected to a Redi Flo3 submersible pump Installation depths Maximum installation depth below the static water level 500 feet Minimum installation depths 1 75 below the dynamic water level Vertical installation During start up and operation the pump must always be completely submerged in water Horizontal installation The pump must be installed at least 1 75 ft below the dynamic water level If there is a risk that the pump might be covered by mud the pump must always be placed in a flow sleeve 17 Generator Operation e It is OK to operate the Redi Flo3 with a generator The generator must be sized 10 above the pumps P1 Input Power values Use the table to select the correct size generator for the motor HP MotorHP Min Generator Size Watts 1 3 1 2A 1 2 3 4B 1 11 2C Page 9 Operating the Pump 18 Starting the Pump for the First
3. 1020 1610 760 1200 630 990 480 770 11 Motor Cable Redi Flo3 pumps are specifically designed to be used with Grundfos SQE NE Tefzel motor leads Standard SQE NE Tefzel motor leads are available between 25 and 300 foot lengths in 5 foot increments Custom lengths longer than 300 feet are available in 10 foot increments up to 600 feet from the factory Installation Procedures Installation Procedures General Note Do not lower or lift the pump by means of the motor cable The loose data plate supplied with the pump should be placed close to the installation site 12 Installing the cable plug to the motor To install the cable plug proceed as follows 1 Check that the cable is of the correct type cross section and length 2 Check that the mains on the location has correct connection to ground 3 Check that the motor socket is clean and dry 4 Press the cable plug into the motor socket The plug will only fit one way see fig 6 5 Install and tighten the four nuts see fig 6 When the plug has been installed there must not be a clearance between the motor and the cable plug Fig 6 13 Installing the cable guard To fit the cable guard proceed as follows 1 Make sure that the motor lead lies flat in the cable guard 2 The two flaps of the cable guard must engage with the upper edge of the pump sleeve see fig 7 Fig 7 3 Fasten the cable guard to the cable plug with the
4. four screws supplied see fig 8 Page 7 14 Piping 15 Installing the Pump Procedures The pump should only be gripped by the two flats at the top of the pump as shown in fig 9 e The pump can be installed vertically or horizontally During operation the pump must always be completely submerged in water e When plastic pipe is used a stainless Fig 9 steel safety wire is recommended for lowering and lifting the pump Fasten the wire to the eyelet on the pump as shown in fig 10 e The threaded joints must be well cut and fit together tightly to ensure that they do not work loose Installation Depth The dynamic water level should always be above the pump see fig 11 A Dynamic water level B Static Water Level C Minimum 3 well diameter D Drawdown B E Installation depth below static A water level Maximum 500 feet To install the pump follow these steps 1 Install the enclosed data plate sticker at the well head 2 Check the well for proper clearance the well must be at least 3 in diameter It is a good idea to check the well for clearance using a plumb ring 2 95 x 10 in 3 Attach the first section of riser pipe to the Fig 11 pump Page 8 Installation Procedures 16 Installing the Pump cont 4 Lower the pump into the well Make sure the motor cable is not damaged when the pump is lifted or lowered into the well
5. you can obtain the locations of our service and repair facilities is 1 800 333 1366 Federal Communications Commission Notice This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated inacommercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense y Z 7 GRUNDFOS X Leaders in Pump Technology Grundfos Pumps Corporation 3131 N Business Park Ave Fresno CA 93727 Customer Service Centers Allentown PA Fresno CA Phone 800 333 1366 Fax 800 333 1363 Canada Oakville Ontario e Mexico Apodaca N L L RF I0 008 Rev 2 00 Visit our website at www us grundfos com PRINTED IN USA For Sales amp Service Contact geo 2650 E 40th Ave e Denver CO 80205 Phone 303 320 4764 e Fax 303 322 7242 1 800 833 7958 www geotechenv com __KReq Fi9 3 SQE NE Environmental Pumps Installation and Operating Instructions e zafi es D aa ea Efficien
6. LIMITED WARRANTY Products manufactured by GRUNDFOS are warranted to the original user only to be free of defects in material and workmanship for a period of 18 months from date of installation but not more than 24 months from date of manufacture GRUNDFOS liability under this warranty shall be limited to repairing or replacing at GRUNDFOS option without charge F O B GRUNDFOS factory or authorized service station any product of GRUNDFOS manufacture GRUNDFOS will not be liable for any costs of removal installation transportation or any other charges which may arise in connection with a warranty claim Products which are sold but not manufactured by GRUNDFOS are subject to the warranty provided by the manufacturer of said products and not by GRUNDFOS warranty GRUNDFOS will not be liable for damage or wear to products caused by abnormal operating conditions accident abuse misuse unauthorized alteration or repair or ifthe product was not installed in accordance with GRUNDFOS printed installation and operating instructions To obtain service under this warranty the defective product must be returned to the distributor or dealer of GRUNDFOS products from which it was purchased together with proof of purchase and installation date failure date and supporting installation data Unless otherwise provided the distributor or dealer will contact GRUNDFOS or an authorized service station for instructions Any defective product to be returned to GR
7. The current consumption can only accurately be measured by means of a true RMS instrument If other instruments are used the value measured will differ from the actual value The Redi Flo3 pumps can be connected to a Redi Flo3 status box Note The pump must never be connected to a capacitor or to another type of control box other than a Redi Flo3 status box The pump must never be connected to an external frequency converter Motor protection The motor has built in automatic thermal overload protection and requires no additional motor protection Connection of motor The motor can be connected directly to the main circuit breaker Page 4 Installation Procedures Installation Procedures 9 Making the Wiring Connections WARNING To reduce the risk of electric shock during operation of this pump requires the provision of acceptable grounding If the means of connection to the supply connected box is other than grounded metal conduit ground the pump back to the service by connecting a copper conductor at least the size of the circuit supplying the pump Single Phase 2 wire Wiring Diagram for GRUNDFOS Motors 1 2 Wire Pump Quick Disconnect with Ground A capacitor or control box should NEVER be connected to a Redi Flo3 submersible pump Fig 5 Page 5 10 Cable Sizing SINGLE PHASE 60 HZ Maximum Cable Length Motor Service to Entrance Motor Rating Copper Wire Size 10 8 340 540 840 250 390 1390 2190
8. Time When the pump has been connected correctly the pump should be started with the discharge valve closed approximately one third Due to the soft start feature the pump takes approximately 2 seconds to develop full pressure Motor Cooling and Other Considerations Make sure the well is capable of yielding a minimum quantity of water corresponding to the pump capacity Do not start the pump until it is completely submerged in the liquid As the valve is being opened the drawdown should be checked to ensure that the pump always remains submerged To ensure the necessary cooling of the motor the pump should never be set so low that it gives no water If the flow rate suddenly falls the reason might be that the pump is pumping more water than the well can yield Water Impurities lf there are impurities in the water the valve should be opened gradually as the water becomes clearer The pump should not be stopped until the water is clean otherwise the pump parts and the check valve may become clogged When the water is clean the valve should be fully opened Minimum flow rate Note Note To ensure the necessary cooling of the motor the pump flow rate should never be set to a value lower than 2 gpm If the flow rate suddenly falls the reason might be that the pump is pumping more water than the well can yield The pump s dry running protection is effective only within the recommended duty range of the pump Do n
9. UNDFOS ora service station must be sent freight prepaid documentation supporting the warranty claim and or a Return Material Authorization must be included if so instructed MANUFACTURER WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES LOSSES OR EXPENSES ARISING FROM INSTALLATION USE OR ANY OTHER CAUSES THERE ARE NO EXPRESS ORIMPLIED WARRANTIES INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE EXCEPT AS EXPRESSLY HEREIN PROVIDED THE GOODS ARE SOLD AS IS THE ENTIRE RISK AS TO QUALITY AND FITNESS FOR A PARTICULAR PURPOSE AND PERFORMANCE OF THE GOODS IS WITH THE BUYER AND SHOULD THE GOODS PROVE DEFECTIVE FOLLOWING THEIR PURCHASE THE BUYER AND NOT THE MANUFACTURER DISTRIBUTOR OR RETAILER ASSUMES THE ENTIRE RISK OF ALL NECESSARY SERVICING OR REPAIR Some jurisdictions do not allow the exclusion or limitation of implied warranties of merchantability and fitness for a particular purpose of incidental or consequential damages and some jurisdictions do not allow limitations on how long implied warranties may last or require you to pay certain expenses as set forth above Therefore the above limitations or exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction The telephone number of our service and repair facilities central directory from which
10. ardous material is left in the pump and in the riser pipe which can be injurous to persons and the environment Disposal Disposal of this product or parts of it must be carried out according to the following guidelines 1 Use the local public or private waste collection service 2 If such waste collection service does not exist or cannot handle the materials used in the product please deliver the product or any hazardous materials from it to your nearest GRUNDFOS company or service center Page 15 Operation via Generator Starting Current Run up Time Motor Protection Power Factor Service Factor oH Values Liquid Temperature 5p H o5 9 5 orlo ko m io sin rl oO Q 9 lt c amp o 2a D ae Q D Note if liquids with a viscosity higher than please contact GRUNDFOS Discharge Port STORAGE CONDITIONS Minimum Ambient Temperature Maximum Ambient Temperature Freeze Protection OPERATING CONDITIONS Minimum Ambient Fluid Temperature Maximum Ambient Fluid Temperature APPROXIMATE DIMENSIONS AND WEIGHT Motor Dimensions MSE3 NE 0 33 0 50A hp 0 50 0 75B hp 1 0 1 5C hp Motor Weights MSE3 NE 0 33 0 50A hp 0 50 0 75B hp h Pump End Dimensions Pump Diameter Pump Diameter incl cable guard Pump End Dimensions min and max 5SQE NE 10SQE NE 15SQE NE 22SQE NE 30SQE NE Pump End Weights min and max All Redi Flo3 Models Well Diameter minimum Installation Depth Ma
11. d be made based on this data 3 Pumped Fluid Requirements Submersible well pumps are designed for pumping turbid free cool water free of air or gases Possible decreased pump performance and life expectancy can occur when operating in conditions outside of this chemistry Water temperature ideally should not exceed 104 F Extended pump life and optimal performance can best be obtained through proper well development and in the case of higher fluid temperatures use a cooling shroud A check should be made to ensure that the installation depth of the pump will always be at least three feet below the maximum drawdown level of the well Fig 1 The bottom of the motor should never be installed lower than the bottom of the screen 4 Motor Cooling Requirements Fi To ensure proper motor cooling refer to the table below for minimum flow requirements Flow velocity Maximum past the motor liquid temperature 0 0 f s 86 F 30 C free convection Min 0 5 f s 104 F 40 C Page 1 Pre Installation Checklist If the pump is to be installed horizontally e g ina tank and there is a risk that the pump might be covered by mud it must be installed in a flow sleeve Liquid temperatures cooling Figure 2 shows an operating Redi Flo3 pump installed in a well Figure 2 illustrates the following Well diameter Pump diameter Temperature of pumped liquid Flow past the motor to the pu
12. f open Pull the pump and clean replace the non return valve d The supply voltage is unstable Check the electrical supply e The motor temperature is too high Check the water temperature Page 13 Page 14 Troubleshooting Instruments not allowed Note The use of the following instruments is not allowed during fault finding 3 Insulation Resistance High voltage Test Test Test Note When measuring use RMS instruments Checking the motor and cable 1 Supply voltage Measure the voltage L1 RMS between phase and L2 Connect the voltmeter to the terminals at the connections The voltage should when the motor is loaded be within the range specified on Page 4 large variations in supply voltage indicate poor electricity supply and the pump should be stopped until the problem has been corrected If the current exceeds the full load current there are the following possible faults Poor connection in the leads possibly in the cable joint Too low supply voltage see item 1 on Page 13 Measure the current RMS while the pump is operating at a constant discharge head if possible at capacity where the motor is heavily loaded For maximum current see motor nameplate Environment During handling operation storage and transport all environment regulations dealing with the handling of hazardous materials must be observed When the pump is taken out of operation it must be ensured AN that no haz
13. g to Active For further information on dry running refer to RediFlo3 Status Box I amp O Maintenance and service The pumps are normally maintenance free Deposits and wear may occur For that purpose service kits and service tools are available from GRUNDFOS The GRUNDFOS Service Manual is available on request The pumps can be serviced at a GRUNDFOS service center Page 11 Assembly Disassembly 19 Assembly of Pump and Motor To assemble pump end and motor proceed as follows 1 Place the motor horizontally in a vice and tighten it see fig 12 2 Grease the motor shaft end with a vegetable based grease 3 Screw the pump end on the motor A spanner may be used on the clamping faces of the pump part see fig 12 4 Install cable guard as described on page 7 When pump end and motor have been assembled correctly there must not be a clearance between pump end and motor To disassemble reverse procedure WA Use pump vise here Fig 12 Page 12 Troubleshooting Troubleshooting Cause Remedy 1 The pump does not run a The fuses are blown Replace the blown fuses If the new fuses blow too check the electrical installation and the drop cable b The GFI circuit breaker has tripped c No electricity supply d The motor protection has cut off the electricity supply due to overload e The drop cable is defective f__Overvoltage has occurred 2 The pump runs but gives The discharge is closed no water
14. mp Strainer Note The well diameter must be at least 3 If there is a risk that the motor will be covered with sediment or the pumped fluid is at an elevated temperature then it is recommended the pump be placed in a Flow Sleeve The motor should always be installed above the well screen 5 Applications Typical applications Environmental applications such as Fig 2 Remediation pumping Leachate recovery Pollution recovery Dewatering 6 Motor Preparation GRUNDFOS MSE8 NE submersible motors have water lubricated slide bearings No additional lubrication is required The submersible motors are factory filled with a special GRUNDFOS motor liquid type SML 2 which will protect the motor fluid down to 4 F 20 C and to prevent the growth of bacteria The level of motor fluid is important for the operating life of the bearings and consequently the life of the motor Refilling of motor liquid It is recommended to check and if needed refill the motor with GRUNDFOS motor fluid SML 2 Page 2 Installation Procedures Pre Installation Checklist To refill the motor proceed as follows 1 Remove the cable guard and separate the pump end from the motor 2 Place the motor in vertical position with an inclination of approx 10 3 Remove the filling plug using a screwdriver or a similar tool 4 Inject motor liquid into the motor with a filling syringe or similar tool see fig 3 5 To all
15. ot let the pump run against a closed discharge valve for more than 5 minutes When the discharge valve is closed there is no cooling flow and there is a risk of overheating in motor and pump Page 10 Operating the Pump Built in protection The motor incorporates an electronic unit which protects the motor in various damaging situations In case of overload the built in overload protection will stop the pump for 5 minutes After 5 minutes the pump will attempt to restart If the pump is started and the well has not recovered the pump will stop after 30 seconds If the pump has been stopped as a result of dry running it will start automatically after 5 minutes or the reset time set by the R100 Resetting the pump Switch off the electricity supply for 1 minute The motor is protected against the following conditions dry running voltage surges up to 5000 V overvoltage undervoltage overload overtemperature MSE 3NE Motors Note To set Dry Run limit in the MSE NE pumps you need to connect the pump to a Redi Flo3 status box Refer to Redi Flo3 status box I amp O for proper connections To set Dry Run protection follow these steps 1 Start the pump against closed discharge 2 Rapidly read the power consumption value W in the R100 display 2 5 3 Multiply this value by 0 9 4 Within the R100 go to display 4 6 and enter the new value minimum power limit 5 Go to display 4 7 and change the settin
16. ow possible air to escape move the motor from side to side And turn the Fig 3 shaft 6 Replace the filling plug and make sure it is tight 7 Assemble pump end and motor 8 Install the cable guard The pump is now ready for installation 7 Installation Postions Positional requirements The pump is suitable for vertical as well as horizontal installation however the pump shaft must never fall below the horizontal plane see fig 4 Fig 4 Page 3 8 Electrical connection General The electrical connection should be carried out by an authorized electrician in accordance with local regulations Before starting work on the pump make sure the AN electricity supply has been switched off and that it cannot be accidentally switched on The pump must be grounded The pump must be connected to an external mains switch The supply voltage rated maximum current and power factor PF appear on the motor nameplate The required voltage for GRUNDFOS submersible MSE3 NE motors measured at the motor terminals is 6 10 of the nominal voltage during continuous operation including variation in the supply voltage and losses in cables If the pump is connected to an installation where a Ground Fault circuit breaker GFI is used as additional protection this circuit breaker must trip out when ground fault currents with DC content pulsating DC occur Supply voltage 1 x 100 115V or 1 x 200 240 V 6 10 50 60 Hz
17. t Permanent Magnet Motor High Starting Torque Soft Start 2 seconds to reach maximum rom and maximum pressure Built in Smart Motor Protection with automatic restart Communication Through the Redi Flo3 Status Box Integrated Protection Against Adverse Conditions Environmental Materials of Construction Please leave these instructions with the pump for future reference GRUNDFOS X Leaders in Pump Technology SAFETY WARNING Electrical Work WARNING To reduce the risk of electric shock during operation of this pump requires the provision of acceptable grounding If the means of connection to the supply connected box is other than grounded metal conduit ground the pump back to the service by connecting a copper conductor at least the size of the circuit supplying the pump to the grounding screw provided within the wiring compartment Pre Installation Checklist 1 Well Preparation If the pump is to be installed in a new well then the well should be fully developed and bailed or blown free of cuttings and sand The construction of the GRUNDFOS Redi Flo3 submersibles makes it resistant to abrasion however no pump made of any material can forever withstand the destructive wear that occurs when constantly pumping sandy water 2 Make Sure You Have the Right Pump Determine the maximum depth of the well and the drawdown level at the pump s maximum capacity Pump selection and setting depth shoul
18. ximum Technical Data 1x200 240V 6 10 50 60 Hz PE As aminimum the generator output must be equal to the motor Pi KW 10 highest value stated on the motor nameplate The motor is protected against Dry running overvoltage undervoltage overload overtemperature 0 33 0 50A HP 1 75 at 230V 0 50 0 75A HP 1 4 at 230V 1 0 1 5C HP 1 15 at 230V Available in 5 ft increments from 25ft 300ft Redi Flo3 5 to 9 The temperature of the pumped liquid must not exceed 104 F that of water are to be pumped SSQE NE 1 NPT 10 15SQE NE 1 1 4 NPT 22 30SQE NE 1 1 2 NPT 4 F 140 F If the pump has to be stored after use it must be stored on a frost free location or it must be ensured that the motor liquid is frost proof The motor must be stored without being filled with motor liquid 20 9 length x 2 68 diameter 20 9 length x 2 68 diameter 22 3 length x 2 68 diameter 2 68 2 91 8 1 to 13 6 8 1 to 14 5 1 to 14 5 1 to 14 5 8 1 to 11 3 2 2 lbs to 3 5 lbs 3 500 feet below static water level Page 16 Technical Data Technical Data PUMP TYPE HP VOLTAGE MAX AMPS ACCESSORIES Page 17 Page 18