Home
        DX90, DX110, 671SP, 672SP, VSBP90M Installation Manual
         Contents
1.        7 ADDITIONAL    CEILING  FRAMING JOIST                CEILING       MATERIAL GRILLE    24    ON CENTER CEILING JOISTS  Housing mounted to additional framing     Installer  Leave this manual with the homeowner   Homeowner  Use and Care information on page 4     30040601D    MODELS DX90   DX110   671SP    672SP   VSBP90M       TYPICAL INSTALLATIONS  CONTINUED          4  ROUND  DUCT    HOUSING                   SUSPENDED      CEILING MATERIAL GRILLE  SUSPENDED CEILINGS    Housing hung with wires   3 point mount     INSTALL THE HOUSING    New Construction       1  Choose the location for your fan in the ceiling  For best possible  performance  use the shortest possible duct run and a minimum  number of elbows        BOTTOM EDGE OF JOIST    2 Position mounting brackets against joist so that bottom edge of  housing will be flush with finished ceiling    Additional positioning feature for 5 8  1     amp  1     thick  ceiling material   Holes in corners of housing are labeled with various ceiling  material thicknesses  Position housing so bottom edge of joist  is visible through a matched set of holes  The housing is now  in the proper position for that ceiling material thickness   Additional positioning feature for 1 2    thick ceiling material   Bend two tabs  on side of housing  90   outward  Lift housing  until tabs contact underside of joist     Mark the keyhole slot on both mounting brackets     Page 2    INSTALL THE HOUSING  CONTINUED     New Construction       3 Set h
2.   MOD  LES DX90   DX110   671SP   672SP   VSBP90M       INSTALLATIONS TYPES  SUITE          J      C  BLE  ID ALIMENTATION        BRIDE  DE FIXATION    BO  TIER                       a  MATERIAU DE    PLAFOND SUSPENDU GRILLE    PLAFONDS SUSPENDUS  Bo  tier suspendus par des fils  Montage en 3 points     INSTALLATION DU BO  TIER    Construction neuve       1  Choisir l emplacement du ventilateur luminaire au plafond  Pour  obtenir un rendement optimal  utiliser le parcours de conduit le  plus court et comportant un nombre minimum de coudes        BORD INF  RIEUR DE LA SOLIVE    2 Positionner les pattes de montage contre la solive afin que le  bord inf  rieurdu bo  tier soit au ras du plafond fini   Aide suppl  mentaire au positionnement pour les mat  riaux  de plafond de 5 8 po  de 1 po et de 1  po d     paisseur    Des trous situ  s dans les coins du bo  tier comportent  l indication de diff  rentes   paisseurs de mat  riau de plafond   Positionner le bo  tier afin que le bord inf  rieur de la solive soit  visible    travers le jeux des trous correspondant    l   paisseur  d  sir  e  Le bo  tier est maintenant correctement en place  pour cette   paisseur de mat  riau de plafond   Aide suppl  mentaire au positionnement pour le mat  riau  de plafond de 1 2 po d     paisseur    Plier les deux pattes de chaque c  t   du bo  tier     90   vers  l ext  rieur  Soulever le bo  tier jusqu    ce que les pattes  entrent en contact avec le bord inf  rieur de la solive   Marquer l emplace
3.   ce  Lorsque vous demanderez le service  sous garantie  vous devrez pr  senter une preuve de la date d   achat original     Date d installation Entrepreneur ou installateur  Num  ro de mod  le et description du produit  POUR OBTENIR DE L AIDE O   DU SERVICE    Pour conna  tre le Centre de service Broan NuTone Canada Inc  autoris   ind  pendant le plus pr  s    Composez le num  ro sans frais   1 888 882 7626  Gardez    port  e de la main   le num  ro du mod  le    la date et la preuve d achat e le type de probl  me  Broan NuTone Canada Inc   1140 Tristar Drive  Mississauga  Ontario L5T 1H9  www broan ca  www nutone ca                         
4.  A PARTICULAR PURPOSE   During this one year period  Broan NuTone Canada will  at its option  repair or replace  without charge  any product or part which is found to be defective  under normal use and service   THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS OR TUBES  BULBS OR BATTERIES  FILTERS  DUCT  ROOF  CAPS  WALL CAPS AND OTHER ACCESSORIES FOR DUCTING  This warranty does not cover  a  normal maintenance and service or  b  any products  or parts which have been subject to misuse  negligence  accident  improper maintenance or repair  other than by Broan NuTone Canada or an authorized  representative   faulty installation or installation contrary to recommended installation instructions   The duration of any implied warranty is limited to the one year period as specified for the express warranty   BROAN  NUTONE CANADAS OBLIGATION TO REPAIR OR REPLACE  AT BROAN NUTONE CANADAS OPTION  SHALL BE THE  PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY  BROAN NUTONE CANADA SHALL NOT BE LIABLE FOR  INCIDENTAL  CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR  PERFORMANCE  This warranty supersedes all prior warranties   To qualify for warranty service  you must  a  notify Broan NuTone Canada at the address or telephone 1 888 882 7626   b  give the model  number and part identification and  c  describe the nature of any defect in the product or part  At the time of requesting warranty service  you must present  evidence of the 
5.  de la  patte  et tourner le tournevis  Passer    97015467  99080517    Plaque du moteur         Moteur DX110 672SP       99080518   Moteur DX90 671SP VSPB90M doucement    l aspirateur la turbine     e  99020276   Turbine le moteur et l int  rieur du bo  tier   30260007     crou du moteur  2 requis  LES PI  CES M  TALLIQUES  97015157   Bloc ventilateur DX110 672SP ET ELECTRIQUES   comprend les r  f  rences 2    5  NE DOIVENT  97015159 Bloc ventilateur DX90 671SP VSBP90M JAMAIS   TRE   comprend les r  f  rences 2    5  IMMERG  ES  30270002   Prise DANS L EAU  2  98009611 Bo  te de raccordement    97015170 Ensemble de boite de raccordement   comprend les r  f  rences 6 et 7   97014922   Bo  tier  30110005 Clapet Raccord de conduit  98008868   Plaque de c  blage  30150002 Vis n   8 32 x 0 375 S     30160007   Vis de mise    la terre       Illustr  e non assembl  e  5  Commander les pi  ces de rechange en indiquant le n   de pi  ce i  et non celui du rep  re           BROAN NUTONE canana INC     Garantie limit  e de un an   Broan NuTone Canada garantit a l acheteur consommateur original de ses produits qu ils sont exempts de d  fauts dans les mati  res premi  res ou la main d   uvre  pour une p  riode de un  1  an    compter de la date d achat original  IL N Y A PAS DAUTRES GARANTIES  EXPRIMEES OU IMPLICITES  INCLUANT MAIS  NON PAS LIMITEES AUX GARANTIES IMPLICITES POUR FIN DE COMMERCIALISATION ET DE CONVENANCE DANS UN BUT PARTICULIER   Durant cette p  riode de un an  Broan NuTon
6. MODELS DX90   DX110    671SP    672SP   VSBP90M       CEILINGS  VENTILATORS    Page 1    Register your product on line at     e For Broan DX90  amp  DX110  www broan ca    e For Nutone 671SP  amp  672SP  www nutone ca       READ AND SAVE THESE INSTRUCTIONS    WARNING  amp        TO REDUCE THE RISK OF FIRE  ELECTRIC SHOCK  OR    INJURY TO PERSONS  OBSERVE THE FOLLOWING     I    Use this unit only in the manner intended by the manufacturer   If you have questions  contact the manufacturer at the address  or telephonenumber listed in the warranty    Before servicing or cleaning unit  switch power off at service  panel and lock the service disconnecting means to prevent  power from being switched on accidentally  When the service  disconnecting means cannot be locked  securely fasten a  prominent warning device  such as a tag  tothe service panel   Installation work and electrical wiring must be done by a qualified  person s  in accordance with all applicable codes and standards   including fire rated construction codes and standards   Sufficient air is needed for proper combustion and exhausting  of gases through the flue  chimney  of fuel burning equipment to  prevent backdrafting  Follow the heating equipment manufacturer   s  guidelineand safety standards such as those published by the  National Fire Protection Association  NFPA   and the  American Society for Heating  Refrigeration and Air  Conditioning Engineers  ASHRAE  and the local code authorities   When cutting or dril
7. e Canada     son choix  r  parera ou remplacera gratuitement tout produit ou pi  ce qui s av  re d  fectueux  sous utilisation et service normaux    CETTE GARANTIE NE COUVRE PAS LES DEMARREURS DE LAMPES FLUORESCENTES ET LES TUBES  LES AMPOULES OU LES PILES   LES FILTRES  LES CONDUITS  LES CAPUCHONS DE MUR OU DE TOIT ET AUTRES ACCESSOIRES DE CONDUITS  Cette garantie ne couvre pas   a  l entretien et le service normal ou  b  tout produit ou pi  ce endommag  s par suite de mauvais usage  n  gligence  accident  entretien inappropri   ou r  paration   autre que par Broan NuTone Canada ou un repr  sentant autoris     une mauvaise installation ou installation contraire au mode d installation recommand     La dur  e de toute garantie implicite est limit  e a une p  riode de un an tel que sp  cifi   pour la garantie exprim  e    L ENGAGEMENT DE BROAN NUTONE CANADA DE R  PARER OU DE REMPLACER  AU CHOIX DE BROAN NUTONE CANADA  SERA LA  SEULE OBLIGATION EXCLUSIVE SOUS CETTE GARANTIE  BROAN NUTONE CANADA NE SE TIENDRA PAS RESPONSABLE DES  DOMMAGES DIRECTS  INDIRECTS OU SPECIAUX SURVENANT A CAUSE DE OU EN RAPPORT A LUTILISATION OU LA PERFORMANCE DE    SES PRODUITS  Cette garantie annule toutes les garanties pr  c  dentes    Pour obtenir le service sous garantie  vous devez  a  aviser Broan NuTone Canada    l adresse ou au num  ro de t  l  phone 1 888 882 7626   b  donner  le num  ro du mod  le et l identification de la pi  ce et  c  d  crire la nature de tout d  faut du produit ou de la pi
8. ling into wall or ceiling  do not damage electrical  wiring and other hidden utilities     TYPICAL INSTALLATIONS    POWER CABLE    dise  TABS    CEILING 17  JOIST  LT                HOUSING                        x  CEILING       MATERIAL GRILLE    16    ON CENTER CEILING JOISTS  Housing mounted directly to joist     WARNING          6   7     11     Ducted fans must always be vented to the outdoors    If this unit is to be installed over a tub or shower  it must be  marked as appropriate for the application and be connected to  a GFCI  Ground Fault Circuit Interrupter    protected branch circuit   Never place a switch where it can be reached from a tub or shower   This unit must be grounded       When applicable local regulations comprises more restrictive    installation and or certification requirements  the aforementioned  requirements prevail on those of this document and the  installer agrees to conform to these at his own expenses   When performing installation  servicing or cleaning this unit  it  is recommended to wear safety glasses and gloves     CAUTION 4 amp     1     2     3     For general ventilating use only  Do not use to exhaust  hazardous or explosive materials and vapors    To avoid motor bearing damage and noisy and or unbalanced  impeller  keep drywall spray  construction dust  etc  off power unit   Please read specification label on product for further information  and requirements     TYPICAL INSTALLATIONS        4  ROUND    POWER CABLE DUCT          
9. ment du trou en forme de serrure des deux  brides de fixation     Page 2    INSTALLATION DU BO  TIER  SUITE     Construction neuve       3 Mettre de c  t   le bo  tier et enfoncer partiellement des clous  dans la solive au sommet des deux marques des trous en forme  de serrure        4 Suspendre le bo  tier aux clous et les enfoncer compl  tement   Pour assurer un fonctionnement silencieux  enfoncer un autre  clou dans le trou sup  rieur de chaque bride de fixation     Construction existante    1  Choisir l emplacement du ventilateur au plafond  Pour obtenir un  rendement optimal  utiliser le parcours de conduit le plus court  et comportant un nombre minimum de coudes        2 Depuis le grenier  positionner les brides de fixation contre la   solive  Tracer le contour du bo  tier sur le mat  riau du plafond    3 Mettre le bo  tier de c  t   et d  couper une ouverture dans le plafond  l  g  rement plus grande que la marque     MOD  LES DX90   DX110   671SP   672SP   VSBP90M       INSTALLATION DU BO  TIER  SUITE     Construction existante       4 Placer le bo  tier dans l   ouverture afin que son bord inf  rieur soit  au ras du plafond existant  Clouer le bo  tier sur la solive    travers  les trous en forme de serrure  des deux c  t  s  Pour assurer un  fonctionnement silencieux  enfoncer un autre clou dans le trou  sup  rieur de chaque bride de fixation     aS SS   Pe TROUS  NAT DNA DE FIXATION    x  gt  gt  WSUPPL  MENTAIRES  o  V lo  5 Des trous de fixation suppl  mentaires 
10. original purchase date           Date of Installation Builder or Installer    Model Number and Product Description    IF YOU NEED ASSISTANCE OR SERVICE   For the location of your nearest Broan NuTone Canada Incorportated dealer   Dial Toll Free  1 888 882 7626  Please be prepared to provide   Product model number    Date and proof of purchase   The nature of the difficulty  Broan NuTone Canada Inc   1140 Tristar Drive  Mississauga  Ontario L5T 1H9   www broan ca  www nutone ca                         PRINTED IN CANADA    MOD  LES DX90   DX110   671SP   672SP   VSBP90M       VENTILATEURS    Page 1    Enregistrez votre produit en ligne         e Pour les Broan DX90 et DX110  www broan ca  D IE P LA FO N D e Pour les Nutone 671SP et 672SP  www nutone ca    LIRE ET CONSERVER CES DIRECTIVES    AVERTISSEMENT A    AVERTISSEMENT A       AFIN DE R  DUIRE LES RISQUES  D   INCENDIE  6  Les ventilateurs avec conduits doivent toujours   vacuer l air    l ext  rieur   D   ELECTROCUTION OU DE BLESSURES CORPORELLES  7  Si cet appareil doit   tre install   au dessus d   une douche ou d   une       OBSERVER LES DIRECTIVES SUIVANTES   baignoire  il doit   tre con  u pour cette application et   tre raccord     1  N utiliser cet appareil que de la mani  re pr  vue par le fabricant     un circuit prot  g   par un disjoncteur de fuite    la terre  DDFT    Pour toute question  contacter le fabricant    l adresse ou au 8  Ne jamais placer un interrupteur    un endroit pouvant   tre  num  ro de t  l  
11. ousing aside and drive nails partially into joist at the top of  both keyhole marks        4 Hang housing from nails and pound nails tight  To ensure a  noise free mount  pound another nail through the top hole of  each mounting tab     Existing Construction    1  Choose the location for your fan in the ceiling  For best possible  performance  use the shortest possible duct run and a minimum  number of elbows        2 In attic  position mounting brackets against joist  Trace outline of  housing on ceiling material    3 Set housing aside and cut ceiling opening slightly larger than  marked     MODELS DX90   DX110   671SP    672SP   VSBP90M       INSTALL THE HOUSING  CONTINUED     Existing Construction       4 Place housing in opening so that its bottom edge is flush with  finished ceiling  Nail to joist through keyhole on both sides  To  ensure a noise free installation  drive another nail through the  top hole of each mounting bracket     ADDITIONAL  MOUNTING  HOLES                   5 Additional mounting holes are provided for installations where  access from above is inconvenient or not possible  Nail or screw  housing directly to joists or framing     INSTALL THE DUCTWORK       1  Snap the damper duct connector onto housing  Make sure that  tabs on the connector lock into slots in housing  Top of  damper duct connector should be flush with top of housing     2 Connect 4    round duct to damper duct connector and extend  duct to outside through a roof or wall cap  Check dam
12. per to  make sure that it opens freely  Tape all duct connections to  make them secure and air tight     Page 3  CONNECT THE WIRING    SCHEMATIC WIRING DIAGRAM    ON   OFF  SWITCH           BLACK     WHITE  ON   OFF SWITCH   GROUND    purchase separately  SWITCH BOX  bare               WIRING  PLATE    120VAC  LINE IN    1  Wire unit following diagram above  Run electrical cable as direct  as possible to unit  Do not allow cable to touch sides or top of  unit after installation is complete     ATTACH THE GRILLE    RECEPTACLE       1  Squeeze grille springs   together and insert  springs into slots in  motor plate        OPTIONALTABS SPRING TABS    NOTE  If desired  rotate  grille 90   and move  springs to optional tabs     SLOT IN MOTOR PLATE    2  Push grille up against  ceiling        MODELS DX90   DX110   671SP   672SP   VSBP90M       USE AND CARE    WARNING  DISCONNECT ELECTRICAL POWER SUPPLY    AND LOCK OUT SERVICE PANEL BEFORE CLEANING OR  SERVICING THIS UNIT     MOTOR LUBRICATION  The motor is permanently lubricated  Do not oil or disassemble motor     SERVICE PARTS       PART NO  DESCRIPTION    97013574  30110230    Grille DX90   DX110   Grille VSBP90M   30110259   Grille Assembly 671SP 672SP  97015467   Motor Plate   99080517   Motor DX110 672SP  99080518   Motor DX90 671SP VSPB90M  99020276   Impeller    Page 4    USE AND CARE    CLEANING    TO CLEAN GRILLE    CAUTION  Plastic parts can be cleaned with mild  soapy water   use a mild detergent  such as dishwashing li
13. phone indiqu   dans la garantie  accessible depuis une baignoire ou une douche    2  Avant de nettoyer ou de r  parer l appareil  coupez le courant 9  Cet appareil doit   tre mis    la terre   au panneau d alimentation et verrouillez en l acc  s afin 10  Lorsqu une r  glementation est en vigueur localement et qu elle  d   viter sa remise en marche accidentelle  Si le panneau comporte des exigences d installation et ou de certification  d alimentation ne peut   tre verrouill    apposez un avertissement plus restrictives  lesdites exigences pr  valent sur celles de ce  bien en   vidence  par exemple une   tiquette de couleur vive  document et l installateur entend s y conformer    ses frais    3  Les travaux d installation et de raccordement   lectrique 11  Il est recommand   de porter des lunettes et des gants de  doivent   tre effectu  s par du personnel qualifi   en respectant s  curit   lors de l installation  de l entretien ou de la r  paration  les normes et r  glements en vigueur  y compris les normes et de cet appareil     codes de b  timent en mati  re de pr  vention d incendie      Une circulation d air efficace est requise afin d assurer la combustion ATTE NTI O N    et l   vacuation compl  te des gaz par la chemin  e des   quipements a   ne     combustion pour pr  venir les retours de chemin  e  1  Pour ventilation g  n  rale seulement  Ne lutilisez pas pour    Conformez vous aux instructions et aux standards de s  curit     vacuer des vapeurs ou des mati  res dange
14. plaque moteur             NS      ATTACHES NOTE   Si d  sir    pivoter  ATTACHES POUR la grille de 90   et  FACULTATIVES RESSORTS installer les ressorts sur    ttaches fi Itatives   FENTE DE LA PLAQUE MOTEUR fee Qlechics TACUNAUVES    2 Pousser la grille contre  le plafond     MOD  LES DX90   DX110   671SP   672SP   VSBP90M       UTILISATION ET ENTRETIEN    AVERTISSEMENT   AVANT DE NETTOYER OU DE R  PARER    CET APPAREIL  COUPER L ALIMENTATION   LECTRIQUE ET  VERROUILLER LE PANNEAU ELECTRIQUE     LUBRIFICATION DU MOTEUR  Le moteur est lubrifi      vie  Ne pas huiler ou d  monter le moteur     PI  CES DE RECHANGE         REF N   DE PIECE DESCRIPTION    Grille DX90   DX110  Grille VSBP90M  Ensemble de grille 671SP 672SP    97013574  30110230  30110259    Page 4    UTILISATION ET ENTRETIEN    NETTOYAGE    POUR NETTOYER LA GRILLE    ATTENTION   Nettoyer les pi  ces en plastique avec de l   eau  savonneuse ti  de  utiliser un d  tergent doux  comme du d  tergent  liquide pour vaisselle  et les s  cher avec un chiffon doux  Ne pas utiliser  de toile abrasive  de tampons en laine d   acier ou de poudres abrasives   POUR NETTOYER LE BLOC VENTILATEUR     D  brancher le bloc ventilateur  Pour enlever la plaque moteur   trouver  l unique patte sur la plaque moteur  situ  e    c  t   de la prise de  courant   Pousser vers le haut pr  s de la patte de la 9  plaque moteur tout en repoussant le c  t   du    boitier  ou ins  rer un tournevis a lame       plate dans la fente du boitier  pr  s
15. quid  and dried with a soft  cloth  Do not use abrasive cloth  steel wool pads or scouring powders     TO CLEAN FAN ASSEMBLY    Unplug fan assembly  To remove motor plate  Find the single tab on  the motor plate  located next to the receptacle   9  Push up near motor plate tab while pushing out  on side of housing  Or insert a straight blade  screwdriver into slot in housing  next to 10  tab  and twist screwdriver  Gently 11  a    vacuum fan  motor and interior  of housing  METAL AND  ELECTRICAL PARTS                30260007   Motor Nut  2 req    97015157    SHOULD NEVER  Blower Assembly DX110 672SP BE IMMERSED     includes Key No  2 thru 5    Blower Assembly DX90 671SP VSBP90M IN WATER     includes Key No  2 thru 5    30270002   Receptacle   98009611   Wire Panel   97015170   Wire Panel Assembly   includes Key No  6 thru 7    97014922   Housing   30110005   Damper Duct Connector   98008868   Wiring Plate   30150002   Screw  no  8 32 x  375   30160007   Ground Screw    97015159         Not shown assembled   Order replacement parts by    PART NO       not by    KEY NO     BROAN NUTONE canana Inc     One Year Limited Warranty  Broan NuTone Canada warrants to the original consumer purchaser of its products that such products will be free from defects in materials and  workmanship for a period of one  1  year from the date of original purchase  THERE ARE NO OTHER WARRANTIES  EXPRESSED OR IMPLIED   INCLUDING  BUT NOT LIMITED TO  IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR
16. reuses ou explosives   des manufacturiers d   quipement de chauffage  tels qu ils sont 2  Afin d   viter tout dommage au roulement du moteur et de    publi  s par la National Fire Protection Association  NFPA  et d  balancer ou de rendre bruyante la turbine  gardez  l American Society for Heating  Refrigeration and Air Conditioning votre appareil    l abri des poussi  res de gypse et de  Engineers  ASHRAE  ainsi que les responsables des codes locaux  construction r  novation  etc    Lorsque vous coupez o   perforez un mur ou un plafond  3  Nous vous recommandons de lire l   tiquette indiquant les  prenez garde de ne pas endommager les fils   lectriques ou caract  ristiques de votre ventilateur pour de plus amples  autre installation qui pourraient y   tre dissimul  s  renseignements et exigences        INSTALLATIONS TYPES INSTALLATIONS TYPES    CONDUIT ROND    g DE 4 po  C  BLE D   ALIMENTATION C  BLE D   ALIMENTATION N                                                                 Y BRIDES DE FIXATION   Re  SOLIVE DE   ee   PLAFOND   L    BO  TIER           7 sS F  CADRE i   MAT  RIAU   MAT  RIAU   SOLIVE   DU PLAFOND GRILLE DU PLAFOND GRILLE AREE EAE PLAFONC  SOLIVES DE 16 po CENTRE A CENTRE   SOLIVES DE 24 po CENTRE    CENTRE    Boitier mont   directement sur une solive  Bo  tier mont   directement sur un cadre suppl  mentaire   Installateur   Laisser ce manuel au propri  taire     Propri  taire   Renseignements sur l   utilisation et l   entretien en page 4   30040601D  
17. sont pr  vus pour les    montages o   l acc  s par le dessus n est pas pratique ou impossible   Clouer ou visser le boitier directement sur les solives ou sur le cadre     INSTALLATION DU CONDUIT                           AU RAS DU BO  TIER         i    Lz     1  Enclencher le clapet raccord de conduit au bo  tier  S assurer  que les pattes du raccord soient verrouill  es dans les fentes du  bo  tier  Le dessus du clapet raccord de conduit doit   tre au  m  me niveau que le dessus du bo  tier     2 Raccorder un conduit rond de 4 po au clapet raccord de conduit  et rallonger le conduit jusqu      un capuchon de toit ou de mur  ext  rieur  S assurer que le clapet puisse s ouvrir librement   Sceller herm  tiquement tous les joints    l   aide de ruban    conduits     Page 3    RACCORDEMENT   LECTRIQUE    SCH  MA   LECTRIQUE    INTERRUPTEUR    MARCHE ARR  T     ON OFF     LIGNE  D   ENTREE  BO  TIER DE APPAREIL  L INTERRUPTEUR          INTERRUPTEUR  MARCHE   ARR  T   vendu  s  par  ment         NOIR    BLANC      MISE     LATERRE    PRISE    BO  TIER DE  LINTERRUPTEUR         BRANCHEMENT    LIGNE D   ENTREE  DE 120 V c a     1  Cabler l appareil en suivant le sch  ma ci dessus  Faire passer le  cable   lectrique aussi directement que possible jusqu    l appareil  Une  fois l installation termin  e  le c  ble ne doit en aucun cas toucher le  dessus ou les c  t  s de l appareil     FIXATION DE LA GRILLE    1  Pincer les ressorts de la  grille et les ins  rer dans les  fentes de la 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
DITORIAL  BEKOS - Cera para muebles nº 312  Bedienungsanleitung (Deutsch)  instruction manual bedienungshandbuch manuel d`instructions  MOTOR AIRE VELOCIDAD BAJA Manual de instrucciones 0197  PCG-SRX51P - Sony Europe  Reporter de guerres  0 - Clear-Com  PC-Based Exercise Stress ECG User Manual      Copyright © All rights reserved. 