Home
ICI Installation Manual
Contents
1. Connect the HOT red wire of the 2 wire communication path to the left terminal position labeled HOT A 2 Connect the COM black wire of the 2 Wire communication path to neighboring terminal position labeled COM A FOR WIRE PATH 2 1 Connect the HOT red wire of the 2 Wire communication path to terminal position labeled HOT B 2 Connect the COM black wire of the 2 Wire communication path to terminal position labeled COM B IC System Installation Guide 9 RAINY BIRD Connect Source Power The ICI Controller has an internal transformer that reduces supply voltage 120 VAC in U S Canadian models 230 240 VAC in other international models 100 VAC in Japan to 24 VAC to operate the CPU and Output Printed Circuit Assemblies and power the ICMs on each wire path g NOTE Each ICI Controller is specifically configured with a different transformer based upon the power supply where the system will be installed CAUTION DO NOT attempt to apply power to the ICI Controller until the supply voltage 100 120 230 240VAC has been verified on the Controller and matches the Installation Site supply power CAUTION All electrical wiring connections and wiring runs must be made according to local building codes Once these precautions have been met it is safe to plug in the supplied power cordset into the Power Entry Module located on the bottom left of the ICI Controller In the event
2. ICMs WARNING Field wire paths must be kept separate from other wire paths Do not connect the field wires together from different output group wire paths IC System Installation Guide 3 RAINY BIRD Installation Checklist We recommend you complete the following steps in order to properly install the ICI controller For your convenience a check off box has been provided for each step Verify the contents of the packing box Choose a location to mount the ICI in the building Gather installation tools Obtain Mounting Hardware and attach the controller to the wall Connect field wiring Connect power supply Install version 7 0 or later of the central control software in the computer Attach USB cable after version 7 0 or later central control software is loaded Complete the installation IC System Installation Guide RAINY BIRD Verify Contents of the Packing Box ICI Controller Keys Rain Bird Installation Guide Mounting Template In some markets the following will also be included power supply cord USB cable If these cables are not included in the box please contact your distributor IC System Installation Guide 5 RAINY BIRD Choose Location to Mount the ICI Choose an indoor location that ls easily accessible Allows for comfortable viewing Has a flat wall surface Is near a 100V 120 V or 230 240 V AC power source depending on model
3. Is located within 5 feet 1 5 meters of the Central Control computer this can be increased up to 25 feet 7 5 meters with a longer USB cable not supplied NOTE This controller must be installed in compliance with electrical codes 15 in 38 1cm min T 14 3 in 36 4 cm N 12 7 in 32 2 cm Wall Eye Level Power Cord 5 5in 14cm for ICI Unit Cabinet Depth Field Wiring In Conduit Floor 6 IC System Installation Guide RAINY BIRD Gather Installation Tools Phillips head screwdriver LR Slotted thin blade screwdriver pls Marking Pencil I 224257 etal drill bit s Hammer Electric drill or hammer drill if installing in masonry or concrete IC System Installation Guide 7 RAINY BIRD Mount Controller 1 If necessary unlock the door with the supplied key Open the door of the 2 cabinet and swing it to the left zi 2 Remove the foam insert used to stabilize E SEE the transformer during shipping 3 Attach the mounting template to the ab ii MOUNTING TEMPLATE mounting surface at eye level using the mounting guide in the back center of the plastic housing Make sure that at least A one of the mounting holes lines up with a R wl wall stud or other solid surface 14 43 preferably on the left side of the template Make sure the template is level 4 Drill or tap a pilot hole on each m
4. RAINY BIRD IC System Interface Installation Guide July 2009 RAINY BIRD IMPORTANT NOTES INSTALLING THE ICI Integrated Control Interface 3 ae eE O Ee E mem cc 4 Verify Contents of the Packing BOX csccccsecccsseecccsusesssesecssesessueeesseuessuesesscesesseesesseeessanes 5 Choose Location to Mount the ICI cccccccccscecccseseccsnsecnsusesssusesesesesseeessaesessaesessnesessnesesanes 6 Gather INS TANGO TOOS 7 dle Ting eiel mEEEEE sees 8 COMMECL ICIS WHA EE 9 Connect Source Power iii 10 Soineizan izius 11 2 IC System Installation Guide RAINY BIRD IMPORTANT NOTES INSTALLING THE ICI Integrated Control Interface This section explains how to mount the ICI controller on the wall and connect the wiring gt gt e eS NOTE The ICI controller must be installed in compliance with all electrical codes and must be installed indoors NOTE The installation of the ICI controller should be done with power supply disconnected NOTE Do not connect the USB cable to the central control computer until the Central Control software has been loaded Specific drivers are required to operate the IC Interface through the Central Control NOTE For the first two minutes after the wire path has been activated there will not be any operation or response from the field
5. ark for the mounting holes 5 Remove the mounting template from the surface If necessary install wall anchors Drive a 8 screw into the top center pilot hole 6 Slide the controller over the top center screw Line up the controller cabinet with the remaining four pilot holes Drive the appropriate 8 fastener s through the mounting holes into the mounting surface Verify that the cabinet is secure 8 IC System Installation Guide RAINY BIRD Connect Field Wiring Field wires are connected to the Driver Boards using the screw terminals located at the bottom of the board The Integrated Central Interface ICI is available in two configurations with a single driver board or dual driver board models The ICI single driver board has two wire path outputs and the ICI dual driver board has four wire path outputs Each wire path can have up to 750 ICMs The ICI cabinet should be mounted on an interior wall as close to the incoming wire paths as possible and within 5 feet 1 5 meters of the central control computer up to 25 feet 7 5 meters if an extended USB cable is used not supplied 2 Wire Path Connections On the lower left corner of each Driver Board is a 4 terminal connection block see Figure The left terminal pair is considered wire path 1 by the central control software If there are two Driver Boards in the ICI the left Board contains path 1 and 2 FOR WIRE PATH 1 1
6. ptions USA 120VAC 10 60Hz 2Hz JAP 100VAC 10 50Hz 2Hz INTL 230VAC 10 50Hz 2Hz AUS 240VAC 10 50Hz 2Hz Output Voltage 26 28 VAC Power Requirements Greater than 1 5 Ampere capacity 12 IC System Installation Guide
7. that you must change the Source Power protection fuse please refer to the photo at right Carefully pry open the hinged door using a small straight blade screwdriver This will allow access to the red fuse holder carefully pull this straight out to expose the specified 1 5 amp 14 x 1 amp 1 4 Slo Blo fusesized for your voltage application Install in the reverse procedure and hinge up the locking door until it clicks into place 10 IC System Installation Guide RAINY BIRD Complete Installation 1 Double check that a the enclosure is mounted securely to the wall b conduit for field wiring if used is attached securely c the power cord easily reaches the power entry module on the bottom of the ICI Controller 2 Plug in the power cord and turn on 3 Load version 7 0 or later central control software in the computer 4 Attach USB cable to computer after version 7 0 or later central control software is loaded 5 Verify communication with the central control computer 6 Congratulations You have successfully installed the ICI controller IC System Installation Guide 11 RAINY BIRD ICI System Specifications INDOOR INSTALLATION ONLY Operating Temperature 14 F to 125 F 10 C to 51 C Storage Temperature 40 F to 150 F 40 C to 65 5 C Operating Humidity 75 max at 40 F to 108 F 4 4 C to 42 2 C Storage Humidity 75 max at 40 F to 108 F 4 4 C to 42 2 C Incoming Voltage O
Download Pdf Manuals
Related Search
Related Contents
Approx APPPCI2P3V2 Dyno 11C Dyno 14C Copyright © All rights reserved.
Failed to retrieve file