1. LOSSOO SMART SWITCH OCCUPANCY SENSOR Installation Manual LIGHTING Features Maximum Energy savings Sensitive 180 view passive infrared motion detector keeps lights on only when rooms are in use No ON switch so lights are never left on by mistake Meets California Title 24 standards Suitable for all utility rebate programs Maximum Coverage 180 wide angle detection pattern Picks up people entering door ways quickly with standard next to doorway location needs for multiple sensors Superb small movement sensitivity within 18 feet Great for sedentary office use No dead spots with 18 sensing fingers Easy Installation Works with electronic ballasts No minimum load requirement Replaces single pole wall switches without additional wiring Decorator style rectangular switchplate included Only 1 2 protrusion from switch plate No adjustments required for most installations Covers 1000 square feet eliminates e Compact design fits standard switch boxes with plenty of room for wiring e Tamperproof control panel cover reduces call backs for tampering Maximum Versatility e Switches all types of fluorescent and or incandescent lighting e Fits single or multi gang locations without special adapters Specifications Coverage 1000 square feet up to 32 from the sensor Detection Zone 180 in 18 zones 32 range Detection Pattern Side V
2. e wattage limits may damage the unit To switch more wattage an electrician can install a relay to handle the load e Do not use LOS800 to control high intensity discharge lights fans heaters or motors Small bathroom exhaust fans may be used with LOS800 e The LOS800 may be used with both standard and electronic fluorescent ballasts Installation Step by Step 1 Remove the existing switch if necessary 2 Connect as shown in the wiring diagrams See page 3 3 Twist on wire nuts Secure with electrical tape Mount LOS800 in wall box with two screws provided 4 Place switch in OFF position before turning on power 5 Press the Auto Off switch IN to Auto After a short delay the lights will turn ON When the room is vacated the lights will turn OFF after the time delay you set 6 See Adjustments section for control options Only make adjust ments after a 3 minute warmup period 7 Attach the wall plate WALL MOUNTING BOX Black ADJUSTMENT ACCESS COVER Removable only when switch plate is off Wiring Diagrams Caution Basic Wiring Diagram POUR THE PONER Ferg Se Level Lain OR TURNING OFF THE CIRCUIT Sn CNS BREAKER FOR YOUR SAFETY AND TO PREVENT DAMAGE TO HOT BLACK THE UNIT e The supply ground wire must be tightly secured to ground 3 way Switch wiring Diagram Multiple Level Lighting Wiring Diagram COMMON WHITE HOT BLACK Adjustments Field o
3. f View Adjustment If the sensor is seeing out through a doorway into a hallway or seeing undesired areas simply cover part of the sensor lens with Opaque white tape or a paper label Clear tape may be used but it limits detection only partially Test that the portion of the lens covered limits detection as desired and does not reduce detection in other areas Sensor has view of adjacent area Removing the Adjustment Access Cover This cover is tamperproof and can not be removed if the switch cover Plate is attached The cover has two ears that hook under the cover plate and prevent tampering To remove the cover insert a screw driver into the latch and pull forward Insert small screwdriver into slot and pull forward gt Time Delay Adjustment The time delay adjustment can be set so the lights turn off from 8 seconds minimum to 15 minutes maximum after the room is vacated approximate Walk Test To test the detection pattern of the LOS800 make no motion for 30 seconds Move sideways up to 12 The red LED flashes once every 4 seconds when turned on initially and twice every second to show detection Hole for voucipigie screw Mounting screw LED for walk testing detection indicator Motion Sensor lens Time delay 8 second minimum 15 minute maximum Turn the control gently clockwise with a small screwdriver for more time delay Auto Off switch aut
4. her rights which vary from state to state 170 Ludlow Avenue Northvale NJ 07647 USA Tech Help Line Fax Back Website e mail 888 722 1000 888 722 1232 www rclighting ca sales prclighting ca
5. iew 32 Note Detection of sedentary small move ment desk work within 18 Time Adjustment 8 seconds to 15 minutes after motion stops approximate Detection Indicator Red LED Energy Codes Complies with California Title 24 Switching Capacity 120v 800w Incandescent amp Fluorescent 277v 1200w Incandescent amp Fluorescent Minimum Load None Power Consumption Negligible Wiring Replaces single pole wall switch 3 wire system where neutral amp hot are present Temperature Range 4 F to 104 F 20 C to 40 C Humidity Range 93 relative humidity Approvals UL Listed Photocontrol UL Standard 773A Weight 3 3 OZ no box Parts List LOS800 Sensor Matching Wall Plate 2 matching wall plate screws 2 sensor mounting screws Dimensions A 4 06 103mm B 1 69 43mm C 2 25 57mm D 2 56 65mm E 1 25 32mm F 5 18mm G 1 68 43mm Selecting A Location Locate the LOS800 where it has an unobstructed view of the room particularly the areas normally occupied by people Ideal mount ing height is 3 5 to 4 5 feet above the floor If people cannot see the sensor lens from their normal positions in the room the sensor will not detect their presence High cabinets walls doors and other obstructions may limit the sensor s view of the entire room If obstructions can be moved the sensor will have a better view If the areas obstructed are no
6. ng heaters or air conditioning vents Mask sensor lens if necessary 4 Make sure unit is at room temper ature If it was installed immediately after being in an extremely hot or cold environment wait an hour for it to adjust Limited Warranty An LOS800 Smart Switch requires no maintenance other than keeping the lens area clean and free of obstructions do not attempt to open or repair the unit There are dangerous voltages inside the case and no user serviceable parts Your LOS800 will be replaced or repaired at our option if it proves to be defective in workmanship or materials within one year from the date of original purchase For repair or replacement return the product freight prepaid and insured to the address below The LOS800 should be packed carefully Please include your sales receipt and a description of the problem R C LIGHTING If your unit is out of warranty or the damage is unrelated to its original manufacture return your unit directly to RC Lighting with a check for 20 00 payable to RC Lighting We will repair or replace the unit Under no circumstances shall we be liable for any incidental or con sequential damages arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property or revenue or cost of installation removal or re installation This warranty gives you specific legal rights and you may also have ot
7. o In Off Out Mounting screw Hole for Coverplate screw Over tightening screw will strip threads Troubleshooting Lights do Not Turn On 1 Check that e the lamps and fixtures work e wiring exactly matches the wiring diagram e wiring polarity is correct e power is on e sensor has warmed up for 3 minutes e off auto switch is not OFF 2 Make sure sensor s view of the room is not blocked Lights do Not Turn Off 1 Check that the Time delay control is set to minimum 2 Stay completely out of the protec tion pattern to avoid activation 3 Make sure sensor is not seeing movement in an adjacent area through a doorway or other opening 4 Make sure unit is not aimed at something that would move or cause a temperature change such as hot water pipes air conditioners or heating vents 5 Check that the wattage controlled does not exceed the maximum limits Lights Go On and Off Quickly 1 Check that wattage controlled does not exceed maximum limits 2 Certain energy saving fluorescent lamps strobe when turned on within a minute of being turned off Lights Go On for No Reason 1 Look for sources of electrical noise such as fans or air conditioners on the same circuit or nearby If possible unplug or move the noise sources 2 Check if sensor is seeing into adjacent rooms or hallways Mask sensor lens in that direction with opaque tape 3 Check if sensor is Seei
8. t areas normally occupied the sensor will still be able to see normal occupancy Cabinet obstructs sensor s view of active area Sensor Obstruction moved sensor has full view If the room is L shaped or the sensor s view is badly obstructed from the door switch location use the LOS2500 ceiling mounted sensor instead of the LOS800 Ceiling mounted LOS2500 sensor with 360 detection Top View 50 Do not locate sensor over or looking at heating vents baseboard heaters hanging plants or air conditioners Do not locate sensor where it will view direct sunlight If the sensor s location gives it a view of the other rooms or hallways lights will be turned on when movement is detected in these adjacent areas If this is undesirable the sensor s detection zone may be restricted by covering a portion of the lens with a white paper label or tape Sensor has view of adjacent area Installation Caution e TURN OFF ALL POWER BY REMOVING THE POWER FUSES OR TURNING OFF THE CIRCUIT BREAKER FOR YOUR SAFETY AND TO PREVENT DAMAGE TO THE UNIT e Please read this entire Owner s Manual before installing All wiring should comply with local electrical codes and requires a qualified electrician e Make sure the total lighting load connected to the LOS800 does not exceed the following 120v 800w Incandescent amp Fluorescent 277v 1200w Incandescent amp Fluorescent Exceeding th