Contents

1. ORGS WE SCIENCE PESO SER teeta meaticge OCEANOGRAPHERS amp HYDROLOSISTS HydroLink ML3 Series Wireless Data Transceivers For Internal GPS DSM132 232 and P66 Depth Sounder Quick Start Guide and User s Manual te aen x ce A II on EN E ae M Pl Ac tel a 110 Copperwood Way Suite E Oceanside CA 92054 760 754 2400 Table of Contents Title Page Number Ce acs EEE ENEA OA E E E AA 3 VOINIC VY oh A T E N T E A lates 4 Secun d Concur EADE Pera a a N iene enenge ne 4 Section 2 Configuring a secondary instrument occonnccicscrieiiiii eiii 5 Section Remote transcelVer Setup ossis ue niiiteeMnai ences 5 Section 4 Base transceiver setup and system power up esssesssssesserseresrssrssresresresresns 9 Secon o WinRiver Setup curio e E 10 SecHon O Connects and Wiring a sat tical va pevereue ena ented st dps E E iaewae 11 DeCHON 7 OW CE PEG UIC PNG Sia sista ies icce ined ean E tani oiahecdteaied acodu dls 11 DectiONyo Allen Mae regure NIC reia dsertoherstieaiveee nen T pean te 11 wo 018 6 9 eal Nee Ao Pg gL sh gel as ee eee mer ere er eee ener eee meer een ere reer eran ere 12 SechOn 107 TrOUbI eS OO CV sinesi a ie 13 Section 11 Technical specifications snini aN 14 Section 12 Regulatory information esessseesesserssrssssrssrsstssrssrsstsstssrsstesrsseesessrssreseesesses 14 Secom 1o FO C MO tH 1G AU Oeria r E E TE 14 QUICK START GUIDE FOR THE OCEANSCIENCE RIVERB
2. SR SR O BR Link Established Remote sending SG IF IF SG IF IF data Link Established Remote sending data Link Established Base sending ned sc a qos Legend BR Blinking Red IF Intermittent Flash Red O Off SD Solid Red Dim SG Solid Green SR Solid Red Bright WinRiver Setup Start the base PC and the corresponding application software Open your Acquire version of WinRiver Go to settings and open the heading communications Click add then Broad Band ADCP then Next You will be asked on which port is it attached Port identification may be different for each laptop so make sure the correct port is chosen Once you have chosen a port and clicked next you will be prompted for the baud rate Select the same baud rate that is being used by the HydroLink transceivers and ADCP Set parity at none and stop bits at 1 Click next and be prepared to wait a few seconds The general screen should appear with two boxes check use software Breaks only Click finish If you have other devices such as a GPS or depth sounder continue to add them using these same steps If you have no other devices move on to the next step Setup the ADCP using the ADCP Configuration Wizard according to USGS standard practice Now you re ready to tryout your ADCP First turn the Riverboat power switch on and confirm that LED 1 on the remote transceiver is green If it is choose acquire and start pinging in WinRiver The control
3. GPS unit and transceiver with data and antenna cables connected be Figure 8 Equipment nested with foam spacers power wires connected Figure 9 Antenna mount on sliding crossbar Figure 10 GPS dome antenna and antenna cable installed Figure 11 Depth sounder installed on Riverboat transom Base Transceiver Setup and System Power up Setup for your base system is done using the cables supplied Figure 11 shows the equipment needed for your base system HydroLink ML3 Base unit Figure 11 MagMount Antenna P66 Data Cable DSM 132 GPS Cable ADCP Base Cable Attach the base unit antenna Apply power to the base through the black Kobiconn DC connector with either a DC power adapter or an ADC wall transformer The base LEDs should all be red at this point Flip the toggle switch on the Riverboat to turn on the power Confirm power to your instruments is your battery charged Shortly after both units are powered up they should establish a communications link with each other to complete the connection Refer to Table ML3 1 below to confirm that a proper link has been established This table is also printed on both transceivers In this initial test condition with ADCP and both transceivers powered up and the laptop off transceiver LEDs should conform to line two on the table link established remote sending data Table ML3 1 gt LED 1 LED 2 LED 3 LED 1 LED 2 LED 3 Power On No Link SR_ SD
4. transceiver should be powered from a clean DC power source Input voltage range must be between 10V and 14V Power source should be capable of supplying a peak current of 1 0 Amp Power cable to the transceiver should be routed away from the antenna Close proximity between the two may result interference Transceiver input power is reverse polarity protected Antennae Requirements When purchased as part of The Oceanscience Group Riverboat System the remote boat transceiver utilizes a rugged 2 4GHz 900MHz antenna while the base unit comes equipped with an omni directional antenna All antennae their connectors and cables have 50ohms of impedance Using other antennae connectors or cabling could result in unsatisfactory results Placement of your HydroLink ML2 base unit may have a significant impact on its performance In practice you should also place the transceiver away from computers telephones answering machines and other similar equipment 11 Generally the higher the antenna the better the communications link height is everything To improve the data link Oceanscience offers directional and omnidirectional antennas with cable lengths ranging from 3 to 200 feet and of varying gain When using an external antenna placement of that antenna is critical to a solid data link Other antennas in close proximity are a potential source of interference It is also possible that slight adjustments in antenna placement a
5. Expect about 5 hours of service from each fully charged battery in the field Be sure the power switch is off Install the eround wire splitter Fig 2 onto the black battery terminal Attach the black wire from the data jumper cable to one of the splitter s connectors and the black wire from the ADCP data cable to the other splitter connector The fused red power wire originating from the on off switch attaches to the red battery terminal connect the remaining red wire from on off switch to the red wire of the data jumper cable Figure 3 Depth sounder internal data connector cable Standard Crossbar Attach the GPS antenna mount to the standard crossbar using the 20 x by 5 8 inch buttonhead screws with flat washers inserted from the bottom of the crossbar and secure in place with the nylock nuts Fig 7 For the Sliding Crossbar attach the antenna mount with the 3 8 buttonhead patch screw and flat washer inserted from the top Fig 9 Install the depth sounder on the transom as shown in Figure 11 Install the GPS dome antenna on the antenna mount You ll need to remove the metal thread adapter from the bottom of the dome antenna eee A ee z ae kaboa ee ee ee a a i Figure 7 Antenna mount on standard crossbar a bg D A Ky p G i Lj a d os Fa A MERE Y Ea a nnee TT i af Re ie Pr UNS t i K gt s w rid 4 s et DA oa a Y F Figure 6
6. OAT Using an RD Instruments WorkHorse series ADCP If this is the first time you have used your Oceanscience Riverboat system we highly recommend you familiarize yourself with the setup procedures prior to field deployment Testing in the office can save valuable field time While testing the transceivers in close proximity it is advisable to unscrew the MaxRad antenna from the boat This avoids the possibility of over modulation The most important phase of setup is configuring your ADCP so that it will communicate through the modems This is done by setting the baud rate of the ADCP to 19 200 bps This matches the baud rate of channel 1 of your HydroLink ML2 See section 1 Configuring the ADCP for details on how to do this The next step is to install the ADCP and GPS on the Riverboat see Riverboat Assembly Instructions Install the Remote transceiver in the Riverboat see section 3 Remote transceiver setup Establish communications between your transceivers by completing section 4 Base Transceiver Setup and System Power up Confirm ADCP data transmission through the transceivers section 5 WinRiver Setup You can confirm GPS data transmission in the same manner but your GPS antenna must have an unobstructed view of the sky If you are receiving data from both sensors you can simply turn off the Riverboat toggle and disconnect power to your Base transceiver Once in the field you can apply power and should be ready to begin
7. evice complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation This device must be operated as supplied by The Oceanscience Group Any changes or modifications made to the device without the express written approval of The Oceanscience Group may void the user s authority to operate the device CAUTION The transceiver has a maximum transmitted output power of 955mW It is recommended that the transmit antenna be kept at least 23 cm away from nearby persons to satisfy FCC RF exposure requirements Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the fo
8. io If these do not match the ADCP cannot communicate through the transceiver 1 Connect the ADCP to the computer and apply power see the appropriate ADCP User s Guide 2 Start the BBTalk program and establish communications with the ADCP by choosing Workhorse the appropriate Com and Next If this is the first time using the Workhorse choose Next at the Port Settings window When the Options window appears place a check in the boxes labeled Send CK on baud rate change and Use Software Break 3 Wake up the Workhorse by sending a break signal with the blue button Send the command CR1 to enter setup 5 Find the baud rate on the table below that matches the baud rate of your Oceanscience HydroLink transceivers Com 1 ADCP port 19 200 Bps Send the corresponding CB command NN Table 1 Baud Rate CB Command 4800 CB311 9600 default CB411 6 In BBTalk press F5 and change the settings to match your CB command settings Press OK to exit the communication setup screen 7 Send the command CK to save the new baud rate setting this may not be necessary if there is a check in the box send CK on baud rate change 8 Click File Close to exit the terminal window The ADCP is now set for the new baud rate The baud rate will stay at these settings until you changed back with the CB command Configuring a Secondary Instrument Com 2 Baud Rate of 4800 Bps The baud rate of your GPS echo sounder
9. llowing measures e Reorient or relocate the receiving antenna e Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help This product is licensed by The United States Diversion contrary to U S law is prohibited Shipment or re export of this product outside of The United States may require authorization by the U S Bureau of Export Administration Please contact The Oceanscience Group for additional information or assistance 14
10. or other secondary device must match the Com 2 baud rate When you are setting an instrument s baud rate you are setting its RS232 data rate Note If using an Oceanscience supplied instrument the baud rate has been pre set to the correct rate When instrument set up is complete install both instruments on the Riverboat see the separate Riverboat Assembly Instructions for basic Riverboat assembly Remote Transceiver Setup The ADCP is now ready to communicate with the laptop through the HydroLink transceivers Use the following procedure to install the transceiver GPS unit and battery in the Riverboat electronics compartment and to connect the externally mounted depth sounder Please note Figure 1 the identity of the internal cables and external equipment is as follows upper left GPS antenna upper right ADCP data cable lower right depth sounder cable lower left MaxRad stub antenna for Hydrolink transceiver Also note the smaller battery wires pinned to the hatch collar with tape which will make installation easier A single red power wire originates from the on off switch and one black power wire originates from the ADCP cable Fig 1 FYI There is an additional internal battery wire that runs from the on off switch to the ADCP cable It is connected and tucked into the back of the compartment behind the white foam compartment liner and need not be disturbed Figure 1 Electronics compartment ready for e
11. ormat conflict is to use the ADCP alternate wake up command of three ASCII equals signs Using this alternate control command maintains the binary data format and will be recognized by the ADCP through the transceivers Some GPS instruments transmit and receive data using the NMEA 0183 V3 0 or higher spec This specification calls for a RS 422 transmission format not RS 232 All instrumentation connected to the transmit and receive data lines of the transceiver should be verified to use RS 232 format 12 If using a Trimble DSM132 and you experience garbled data or are having problems establishing communications with your GPS you should restore the unit to factory settings by performing the following steps e Press the v arrow 6 times This places you at the Clear BB RAM screen e Press gt once to highlight the No e Press v once to change to Yes e Press the enter key and all factory defaults will be restored Troubleshooting This section lists some problems that you might encounter while using your HydroLink ML2 transceiver Possible solution I cannot connect e Make sure that you have connected power to your transceivers The LED indicator should emit a green light when powered up being ready to send and receive data then turning blue e Your remote instrument is not configured to use the same serial settings e g baud rate as your HydroLink ML2 e Your transceivers are too far away from each other Mo
12. quipment Also note the two loose cables the GPS data jumper cable Fig 2 and the depth sounder data connector cable Fig 3 Figure 2 GPS Data Jumper All data connectors four yellow one black one in line are keyed and will only attach when oriented correctly Do not force these connectors The threaded antenna connectors are not keyed Begin by placing the Hydrolink transceiver and the Trimble GPS units on end inside the hatch as shown in Figure 6 Connect the MaxRad stub antenna cable to the Hydrolink transceiver and connect the GPS antenna cable to the GPS receiver Now the data cables connect the ADCP data cable to Hydrolink transceiver port A Connect the data jumper cable to port B on the Hydrolink and Port A on the GPS receiver Attach the depth sounder connector cable to its internal mate this small threaded in line connector is keyed and attach its yellow data connector to Port C on the Hydrolink transceiver Slide the transceiver and the GPS unit into the compartment and then nest two of the foam spacers between them and towards the bow as shown Fig 5 Place the other small foam spacers against the stern These will keep the battery from traveling during deployment Finally place the battery between the GPS and the transceiver and add the thin foam spacers on either side see fig 8 You re ready for power connection Battery note We ve provided two 7 2 amp hour batteries with your system
13. s little as 2 feet will solve noise problems In extreme cases such as when the transceiver is located close to pager or cellular telephone transmission towers noise may be reduced by special filters available from Oceanscience RS232 Interface Because the transceivers serial data parameters are fixed instruments and any related application PC software must be set to match The serial data rates for the HydroLink ML2 are 19 200 Bps on Com 1 and 4 800 Bps on Com 2 When configuring the instrument and application software to match the transceiver the PC and instrument should be connected directly If using a GPS provided by Oceanscience there is no need to change the baud rate as they are configured at the factory Do not attempt to change instrument settings using the transceivers Communication is not possible until the instrument and application software settings match those of the transceivers Some instruments transmit or receive control pulses using the computer RS232 com port Because the transceivers transfer binary data with a pre defined data byte length attempting to send control pulses using the transceivers is not recommended A specific example of this is the wake up or break command used by some ADCP manufacturers The standard wake up command is a 300 ms pulse sent from the computer comm port to the ADCP If this pulse is routed through the transceivers it will not be recognized by the ADCP The solution to this f
14. ve them closer or raise the base antenna e Check all cabling connections The link between my e There is substantial interference transceivers e Your transceivers are too far away from each other Move the two devices closer to each other or raise the base antenna disconnects There is no color on e Make sure that power is connected to the device by checking data power circular the LED indicator connector on HydroLink face quick disconnects battery connections are polarity correct Kobiconn DC adapter is connected toggle switch is in the on position I m receiving data but e Verify the baud rate on your data instrument matches the baud rate of your it s garbled HydroLink ML2 If your GPS is Trimble DSM132 restore unit to factory defaults see section 5 RS 232 Interfacing e Check your battery battery connections and fuse 13 Technical Specifications 902 to 928 MHz Transmitter Output Power 1mW to 1W 30 dDm Error Detection 32 Bit CRC resend on error Forward error correction Golay retransmit on uncorrectable error Substitution dynamic ke Max Link Throughput 115 Kbaud standard speed RS 232 RS485 Operating Modes Point to Point Point to Multipoint Repeater Line of sight distance with unity gain antenna Throughput measured assuming 75 frequency availabilit Regulatory Information FCC Identifier KNY21161341911919 DOC Identifier 2329 102 336A FCC Notification This d
15. window will appear followed by the ADCP wakeup message and you will begin to hear a quiet pinging noise coming from your ADCP Congratulations Your system is ready to begin making river discharge measurements 10 Reference Information Connections and Wiring The HydroLink ML2 supports RS 232 with an 8 pin circular Micro Change connector The ML2 is designed to operate as a DTE Data Terminal Equipment When connecting to a DCE Data Communication Equipment a straight cable should be used When connecting to another DTE a crossover serial cable must be used The crossover cable must have TD and RD crossed pins 2 3 and 3 2 The Base Transceiver should be connected to the computer The Remote Transceiver should be connected to the instruments Transceivers are provided as a matched pair that communicates only with each other Each unit of the pair set is programmed with a unique serial number ID When using the cables provided by The Oceanscience Group note that the 8 pin circular connector is keyed and will not align in any way except in the correct alignment Once the keyway is properly aligned the backshell of the connector should be screwed to finger tightness This connector is IP68 rated when properly connected The antenna connector is type TNC and care should be given so as to not cross thread the connector Again finger tight is adequate when threading on the antenna cable Power Requirements The HydroLink ML series
16. your discharge measurements Antenna Port A Port B Port C Com1 Com2 Com3 Overview Thank you for purchasing an Oceanscience Group product It is our intention to provide our customers with the latest technologies the highest quality manufacturing and the most efficient customer service and support This manual outlines the use of HydroLink ML2 series Wireless Data Transceivers with specific references to their use with The Oceanscience Riverboat for ADCP deployment Simply put the HydroLink transceivers eliminate the need for data transmission cables Please note The transceivers have a fixed data transmission rate baud rate In order to send data through them your instruments and laptop or other receiving device must be set to the same baud rates as those installed in the transceivers The default baud rates for your ML2 series transceiver are 19 200 bps for Com 1 and 4800 Bps for Com 2 This rate is optimized and cannot be altered except by The Oceanscience Group The HydroLink ML2 Wireless Data Transceivers are pre configured for high speed data communication and each pair is programmed to communicate only with one another Configuring the ADCP Com 1 Baud Rate of 19 200 Bps The following procedure explains how to set the baud rate and save it in the ADCP This procedure assumes that you will be using the program BBTalk supplied by RD Instruments Begin by configuring the baud rate of the ADCP to match the baud rate of the rad