1. LUMINAMN FLAT PAR LED LIGHT IR REMOTE Product Code SH LED PAR64F User Manual Please read the instructions carefully before use TABLE OF CONTENTS Safety Instructions Technical Specifications Installation How to set the unit How to control the fixture DMX512 Configuration DMX512 Connections Troubleshooting Fixture Cleaning 1 Safety Introductions ZN Please read the instructions carefully which includes important information about the installation operation and maintenance WARNING e Please keep this User Manual for future consultation If you sell the fixture to another user be sure that they also receive this instruction booklet e Unpack and check carefully there is no transportation damage before using the fixture e Before operating ensure that the voltage and frequency of power supply match the power requirements of the fixture e ts important to ground the yellow green conductor to earth in order to avoid electric shock e Disconnect main power before servicing and maintenance e Use safety chain when fixes this fixture Don t handle the fixture by taking its head only but always by taking its base e Maximum ambient temperature is Ta 40 C Don t operate it where the temperature is higher than this e Inthe event of serious operating problem stop using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskil
2. the fixture The IR sensor is located at the top of the LED Lights Please point the remote within 1M from the sensor to control the fixture 6A DMX LED Remote Controller 1 Auto Auto show 2 Sound Sound active 3 DMX DMX512 control be switch mode between address and channel 4 Black Out Press once to shut off the light and again to re activate it 5 Red Red light is turned on 6 Green Green light is turned on 7 Blue Blue light is turned on 8 White Red Green and Blue light are turned on 9 Increase parameters In Color mode the light color with the picture in the above of the same color 10 Reduce parameters 11 0 9 Only in DMX and Color mode the digital key to effective In DMX mode when you press down a key one of digital key digital tube flickered on until you have press three key so far 12 Jump Hop change mode 13 Fade Gradual change mode 14 Color Static color You must first press the Color key if the program is not in Color mode before you can select color from the keypad 15 Flash Only in Auto Dimmer Jump and Color mode the function key to effective Singular time into strobe mode even number exit 7A 6 DMX512 Configuration 3 channels Mode Channel Value Function CH1 0 255 RED dimmer CH2 0 255 GREEN dimmer CH3 0 255 BLUE dimmer 5 channels Mode Cha
3. input AC90 250V 50 60Hz Dimensions L430xW250xH155mm Weight 2 35kg 3 Installation The unit should be mounted via its screw holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be installed by professionals 4 How To Set The Unit 3A Function Description N Function Description Hanging Yoke 6 Earth Display LCD MENU Button DMX IN UP Button DMX OUT DOWN Button Power Cable ENTER Button 4A Display Normal OO OO Down Enter Menu To select the program functions Up To go forward in the selected functions Down To go backward in the selected functions Enter To confirm the selected functions and go into the next layer menu 5A DMX512 Address DMX channel select Master mode Slave mode Sound mode select Sound sensitivity adjust Hop change mode Strobe speed adjust Gradual change speed adjust AUTO show Static colour select Strobe speed adjust anual mode RED dimmer anual mode GREEN dimmer Manual mode BLUE dimmer Normal Shade ormal nversion 5 How to control
4. led people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts e Do not connect the device to any dimmer pack e Do not touch any wire during operation and there might be a hazard of electric shock e To prevent or reduce the risk of electrical shock or fire do not expose the fixture to rain or moisture e The housing must be replaced if they are visibly damaged e Do not look directly at the LED light beam while the fixture is on Warning e To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture e Do not open the unit within five minutes after switching off 2A e The housing the lenses or the ultraviolet filter must be replaced if they are visibly damaged Caution There are no user serviceable parts inside the fixture Do not open the housing or attempt any repairs yourself In the unlikely situation your unit may require service please contact your nearest dealer 2 Technical Specifications 3 5 7channels selectable Flat LED PAR 64 light 4 push button with 4 Digital LED Display Auto Sound Activated DMX512 Master Slave IR Remote Control Light source 181PCS 10mm Ultra Bright LEDs 49 red 72 green 60 blue Please ensure there is nothing in between the remote and the fixture Maximum distance for the remote to work is 2 meters Bulb angle 15 20 degree Power consumption 20W Power
5. lems and interference It is always 7 1 Connect the fixture together in a daisy chain by XLR plug cable from the output of the fixture to the input of the next fixture The cable cannot be branched or split to a Y cable Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 2 The DMX output and input connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually 0 8 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used XLR Male Socket XLR Female Socket 1 Ground 2 Cold 2 Cold 1 Ground 3 Hot 3 Hot XLR Pin Configuration 10A Pin 1 Ground Pin 2 Data Compliment negative Pin 3 Data True positive 8 Troubleshooting Following are a few common problems that may occur during operation Here are some sugges
6. nnel Value Function CH1 0 255 RED dimmer CH2 0 255 GREEN dimmer CH3 0 255 BLUE dimmer CH4 0 255 Master dimmer 0 6 Dimmer mode 7 65 Slow to fast strobe 66 69 None ehs 70 128 Pulse strobe from slow to fast 129 132 None 133 191 Strobe fading in from slow to fast 192 195 None 196 255 Strobe fading out from slow to fast 7 channels Mode Channel Value Function CH1 0 255 RED dimmer CH2 0 255 GREE N dimmer 8A CH3 0 255 BLUE dimmer CH4 0 255 Master dimmer 0 6 Dimmer mode 7 65 Slow to fast strobe 66 69 None CH5 70 128 Pulse strobe from slow to fast CH7 lt 60 129 132 None 133 191 Strobe fading in from slow to fast 192 195 None 196 255 Strobe fading out from slow to fast CH5 Er In standalone mode running speed from CH7 gt 60 slow to fast CH6 isiat color mode 0 255 Static color select CH6 Ke ferehangeinads 0 255 Strobe from slow to fast 0 59 Dimmer mode 60 119 Static color mode CH7 120 179 Color jump change mode 180 239 Color gradual change mode 240 255 Sound active mode 7 DMX512 Connections The DMX512 is widely used in intelligent lighting control with a maximum of 512 channels COMMON DMX INPUT Ne DMX OUTPUT DMX 9A advisable to connect a DMX terminal Resistance 120 ohm 1 4W between pin2 DMX and pin3 DMX of the last fixture Termination reduces signal errors and to avoid signal transmission prob
7. smoky or particularly dirty surrounding can cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days 12A EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 199601 2 EN55103 2 1996 EN61000 3 2 2000 A2 2005 EN61000 3 3 1995 A1 2001 A2 2005 amp Harmonized Standard EN 60598 1 2004 IEC 60598 1 2003 corrigendum 2004 Part 1 General requirements and test Following the provisions of the low voltage directive 73 23 EEC and 93 68 EEC 13A QPF i Sunhope Event SUPPLIES Custom Goso LED LicHriNG Sunhope Inc 2 50 14th Ave Unit G12 13 Markham Ontario L3R0B6 Canada Phone 905 604 7080 Email info sunhope ca Web www sunhope ca www smartlight ca Innovation Quality Performance 14A
8. tions for easy troubleshooting A 1 The fixture does not work no light Check the connection of power and main fuse Measure the mains voltage on the main connector Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly If the DMX LED is on and no response to the channel check the address settings and DMX polarity If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit Some fixtures don t respond to the easy controller You may have a break in the DMX cabling Check the LED for the response of the master slave mode signal Wrong DMX address in the fixture Set the proper address No response to the sound 1 Make sure the fixture does not receive DMX signal Check microphone to see if it is good by tapping the microphone One of the channels is not working well 11A 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 9 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp
Download Pdf Manuals
Related Search
Related Contents
Blacklight Set 120cm - Lite Avaya 1000 Series Video Conferencing Systems User's Manual 取扱説明書 ドラム式洗濯乾燥機 品番 AWD-U860Z A Proteção do Consumidor Internacional no Comércio CMS Virtual Warehouse Producer/Supplier MANUAL REGULADOR MARCA JAR Epson Stylus Pro 7600 Print Engine with UltraChrome Ink Warranty Statement 取扱説明書 - Nasnos Copyright © All rights reserved.