1. BE 98 BODY ELECTRICAL CLOCK CLOCK TROUBLESHOOTING HINT Troubleshoot the clock according to the table below BE1KH 01 Troubleshooting No Clock will not operate Clock loses or gains time 1 5 seconds day DOME Fuse Clock Side Wire Harness Side Ground mlel ae inati E 32l l Combination Meter CHEN RADIO2 Fuse 1 TROUBLESHOOTING NO 1 A CLOCK WILL NOT OPERATE a Check that the battery positive voltage is 10 16 V If voltage is not as specified replace the battery Clock Side Wire Harness Side b Check that the DOME and RADIO2 fuses are not blown If the fuse is blown replace the fuse and check for short c Troubleshoot the clock as follows HINT Inspect the connector on the wire harness side 2003 MR2 RM967U Author Date 1538 BE 99 BODY ELECTRICAL CLOCK Is there battery positive voltage between terminal B and body ground NO Open or short circuit in wire harness between terminal B and DOME fuse YES Is there battery positive voltage between terminal Open circuit in wire harness between terminal E and body ground E and body ground YES Replace clock 2 TROUBLESHOOTING NO 2 neal CLOCK LOSES OR GAINS TIME a Check that the battery positive voltage is 10 16 V If voltage is not as specified replace the battery Clock Side Wire Harness Side p Inspect the error of the clock Allowable error per day 1 5 s 2. econds If the error exceeds the allowable error replace the clock c Check that the clock adjusting button is sticking in posi tion and has failed to return If the error exceeds the allowable error replace the clock d Troubleshoot the clock as follows HINT Inspect the connector on the wire harness side Is there battery positive voltage between terminal B Bellow 10 V and body ground Locate cause and repair or recharge battery YES Adjust or replace clock 2003 MR2 RM967U Author Date 1539