Home
American Power Conversion CTEG4-240MB-5 User's Manual
Contents
1. EIN AMERICAN POWER CONVERSION MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation or exclusion of implied warranties therefore the aforesaid limitation s or exclusion s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL APC BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically APC is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data costs of substitutes claims by third parties or otherwise Entire contents copyright 2006 by American Power Conversion Corporation All rights reserved Reproduction in whole or in part without permission is prohibited APC and the APC logo are registered trademarks of American Power Conversion Corporation All other trademarks are the property of their respective owners
2. ardware and product documentation CTEG4 240MB 5 5 cables 15 black battery jumpers 2 40 black 1 80 black 1 40 red 1 Installing the Enclosure 1 Install an APC approved concrete pad Contact your dealer or refer to the APC Web site www apc com for more information 2 Secure the enclosure to the pad Refer to the diagram below Place the enclosure on the pad The holes on the enclosure must be aligned with the anchor hooks on the pad hardware not included This is a general representation of an enclosure mounted on a pad Configurations may vary Service Entrance id Load Center Utility Power Pr e at Coax Housing Wiring Grounding Install and interconnect ground rods appropriate for proper grounding according to local electrical code requirements Connecting Utility Power to the Enclosure 125 V Duplex 250 V Duplex _ A 3 ea 5 5 2 g a 2 D 3 nd O ea Wiring colors to correspond with the breaker meter base 1 Unlock and open the door of the enclosure 2 Ensure that the utility power switch is OFF 3 Install a high magnetic circuit breaker box 4 Using appropriate conduit connectors run wires from the utility breaker box to the receptacle box inside the enclosure 5 Connect the wires to the receptacle and install it in the enclosure 6 Re
3. dentical types and ratings Substitution of nonidentical parts may cause safety and fire hazards Battery Always replace batteries with same or equivalent type recommended by the Warnings manufacturer Danger of explosion if battery is incorrectly connected or replaced Batteries present a risk of electrical shock and burns from high current in the event of a short circuit Observe proper safety precautions De Batteries must be recycled Deliver the battery to an appropriate recycling GY facility Overhead Never stand underneath a unit while it is hoisted Always wear a hard hat Warnings Lifting Warnings Modules are heavy Use proper lifting techniques and equipment to avoid injury Installation Utility line voltage must be routed to the enclosure Local state federal and or National Electric Code NEC regulations regarding location permits and electrical wiring must be adhered to Do not operate the power supply where the temperature and humidity are outside the specified limits See Specifications in this manual Specifications Environmental Specifications Physical Specifications Height X Width X Depth AT x 28 x 18 119 x 71 x 46 cm Tos 2 kw Unpacking Inspect the unit upon receipt Notify the carrier if there is damage The packaging is recyclable save it for reuse or dispose of it properly Check the package contents The package contains the enclosure battery cables connectors and associated h
4. ferto the CTSP EM User Manual for detailed installation instructions regarding the Interface Harness connections Connecting the Batteries The battery circuit breaker must be OFF prior to battery installation Use normal precautionary measures when wiring and connecting the batteries Tape one end of each jumper cable prior to installation C0 Overview Top Shelf Middle Shelf Battery Battery Battery 4 3 2 Bottom Shelf Wiring Schematic 80 Black to CTSP EM BERR PERE RRR STETTT LLL LLL ELLE ELLE AS Bottom Shelf Middle Shelf Top Shelf Service Contact and Warranty Information Service APC makes every effort to ensure parts and equipment arrive in working condition Occasionally 1t may be necessary to return parts or equipment that are not in working condition If the UPS requires service do not return 1t to the dealer Follow these steps 1 Contact APC Customer Service through the APC Web site www apc com Note the product model number the serial number and the date purchased If you call APC Customer Service a technician will ask you to describe the problem and try to solve it over the phone If this is not possible the technician will issue a Returned Material Authorization Number RMA m Ifthe product is under warranty repairs are free If not there is a repair charge Procedures for servicing or returning products may vary internationally Refer to the APC Web si
5. te for country specific instructions 2 Pack the product in its original packaging If the original packing is not available refer to the APC Web site for information on obtaining appropriate packing materials m Pack the unit properly to avoid damage in transit Never use Styrofoam beads for packaging Damage sustained in transit is not covered under warranty 3 Mark the RMA on the outside of the package 4 Return the unit by insured prepaid carrier to the address given to you by Customer Service How to Contact APC Refer to the APC Web site www apc com Limited Warranty American Power Conversion APC warrants its products to be free from defects in materials and workmanship for a period of one year from the date of purchase Its obligation under this warranty is limited to repairing or replacing at its own sole option any such defective products To obtain service under warranty you must obtain a Returned Material Authorization RMA number from customer support Products must be returned with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase This warranty does not apply to equipment that has been damaged by accident negligence or misapplication or has been altered or modified in any way This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase EXCEPT AS PROVIDED HER
6. www apc co CTEG4 240MB 5 Four Battery Ground Mount Enclosure 240 V User Manual 990 2480 07 2006 General Information The American Power Conversion APC CTEG Enclosure provides power sourcing for broadband cable operations Safety This Safety Guide contains important instructions that should be followed during installation and maintenance ofthe APC equipment and batteries It is intended for APC customers who setup install relocate or maintain APC equipment Only trained service personnel should install and maintain the power supply enclosure Changes and modifications to this unit not expressly approved by APC could void the warranty Failure to observe these warnings may result in serious injury death or damage to the equipment Electrical Do not work alone under hazardous conditions Warnings Do not handle any metallic connector before the power has been disconnected Servicing this equipment may require working with protective covers removed and utility power connected Use extreme caution during these procedures High current through conductive materials could cause severe burns When grounding cannot be verified disconnect the equipment from the utility power outlet before installing or connecting to other equipment Reconnect the power cord only after all connections are made Check that the power cord s plug s and sockets are in good condition Replacement of fuses or other parts must be with i