Home

Operating instructions

image

Contents

1. an m A CONNECTION Fig 5 2 6 Starting and shutdown procedures 6 1 Preparations for starting The pump housing and the suction line must be filled with water or the fluid to be delivered All electrical connections to the pump may only be performed by experts WARNING Avoid any dry running of the pump NOTE We recommend installing dry running protection devices such as flow indicators contact manometers differential pressure switches or level 4 7 controllers The direction of rotation indicated by an arrow on the pump must be respected and controlled after installation X Tighten all screwed connections and en fittings Fig 5 3 Entirely open all shut off devices of the suction and delivery lines Page 9 ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF 6 2 Starting procedure Switch on the motor Check the direction of rotation of the motor by switching it on and off in immediate succession The direction of rotation must be in accordance with the arrow figuring on the pump Adjust the operating point by slowly closing the shut off device of the delivery line If there is no shut off device installed the operating point will be adjusted automatically in accordance with the pump curve WARNING Do not run the pump with a closed delivery line for a longer period of time This may heat up the fluid inside the pump housing and thus damage in
2. e Delivery of acids alcaline solutions etc e Delivery of gaseous fluids e No other than the authorized use nor any conversion of the pump are permitted WARNING Make sure that the materials used for the pump are resistant to the fluids being delivered see the ProMinent list of resistances e f you deliver crystallising fluids make sure that the fluid does not crystallise within the pump Should this happen carefully clean all parts being in contact with the fluid once the pump has been shut off NOTE Disassembly of the pump will cancel the right to all warranty claims 1 2 Sound intensity level The sound intensity level of this pump is lt 70 dB A according to DIN EN 12639 noise measurement of liquid pumps and pump units Page 5 2 Safety This operating manual gives basic instructions which are to be observed during installation operation and maintenance of the pump It is therefore imperative that the manual be read by the responsible personnel operator prior to assembly and commissioning It is always to be kept available at the installation site It is not only the general safety instructions contained under this main heading safety that are to be observed but also the specific information provided under the other main headings 2 1 Identification of safety instructions in the operating manual Safety instructions given in this manual non compliance with which would affect safety are
3. Serial No Po ay OnerNo Designation Material 550 2 PUMA 05 0050 115 rectanguarwasher 554 6 PUMA 00 0090 150 plainwasherZ6 4 DIN125 inox 800 1 PUMA000250004 motor250W 230 400V 50Hz drive magnet 15 18S shaft 14mm ae 901 1 6 PUMA 05 0050 110 hexagon head cap screw M6x45 DIN931 inox 940 1 PUMA 00 0370 028 feather 5x25x5 OOOO O Qty 10 3 Bill of materials von Taine 0807 PVDF FKM Serial No 550 2 PUMA05 0050 115 rectanguarwasher 554 6 PUMA 00 0090 150 plain washer 264 DIN125 inox 800 1 PUMA 00 0250 004 motor250W 230 400V 50Hz drive magnet 15 18S shaft 14mm ProMinent Page 18 Operating instructions ProMinent von Taine 0807 PP PVDF PUMA 00 0090 140 mounting plate polypropylene 901 1 6 PUMA 05 0050 110 hexagon head cap screw M6x45 DIN931 940 1 PUMA 00 0370 029 10 4 Bill of materials von Taine 0807 PP EPDM Serial No 550 2 PUMAO5 0050115 rectangular washer 554 6 PUMA 00 0090 150 plainwasherZ6 4 DIN125 inox 800 1 PUMA 00 0250 004 motor250W 230 400V 50Hz drive magnet 15 18S shaft 14mm D 901 1 6 PUMA 05 0050 110 hexagon head cap screw M6x45 DIN931 inox 940 1 PUMA 00 0370 028 feather 5x25x5 10 5 Bill of materials von Taine 0807 PVDF EPDM Serial No PUMA 00 0250 071 PUMA 05 0050 064 pump housing with thrust ring PVDF P
4. identified by the following symbol see DIN 4844 W9 or where electrical safety is involved with see DIN 4844 W8 Instructions non compliance with which would give rise to malfunctioning of the machinery are identified by the word It is imperative that signs affixed to the machine e g arrow indicating the direction of rotation symbols indicating fluid connection Warnings to protect the pump from dry running be observed and kept legible ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF 2 2 Qualification and training of operating personnel The personnel responsible for operation maintenance inspection and assembly must be adequately qualified Scope of responsibility and supervision of the personnel must be exactly defined by the plant operator If the staff does not have the necessary knowledge they must be trained and instructed which may be performed by the machine manufacturer or supplier on behalf of the plant operator Moreover the plant operator of the operating manual are fully understood by the personnel 2 3 Hazards in the event of non compliance with safety instructions Non compliance with the safety instructions may produce a risk to the personnel as well as to the environment and the machine and results in a loss of any right to claim damages For example non compliance may involve the following hazards Failure of important functions of the mac
5. resulting partial vacuum or by high temperatures The suction line must be a tube or hose which cannot be deformed by the resulting partial vacuum or by high temperatures When dimensioning the tubes fittings etc make sure that the flow resistances are kept as low as possible The flow velocity within the piped suction line should not exceed the limit of 1m s 5 2 2 The delivery line The standard flow velocity within the suction line is 3m s To be able to adjust the flow rate we recommend the installation of a control element inside the delivery line 5 3 Electrical connection The motors should be connected according to the following illustration Page 8 Operating instructions ProMinent von Taine 0807 PP PVDF nn SS ee Zu WARNING N CONNECTION Do not check the direction of rotation without having filled fluid in the pump L1 E i motor protection switch The power supply must have been cut ES for at least 5 minutes before you may start any work at the terminal box of the pump Make sure that the data given on the name plate corresponds to the existing power supply All electrical connections and installations of additional protection devices should be performed by an expert in accordance with the instructions of the local power suppliers and or the Association of German Electrotechnical Engineers VDE The motor must be equipped with a m genta S
6. waste parts nanas rennen 10 ER nale DOSE 10 Fes MEE General NOMAN mm 10 7 2 Preventive maintenance enne nnne nnne anis serae sese nase nano sanas 10 Page 3 ProMinent Table of contents 7 3 Disassembly of the pump iii 12 7 4 Re assembly of the pump iii 13 8 Troubleshooting ea ado ae de dede en sde ne a ee et 15 9 Technical data u0200000 000n0nn0n nun ann nun ann nun nun nun nun ann nun nun nun nun nn nnnn nun nun 16 19 Spare Parks ee ee 17 104 EXD IOGEU VIEW nen een ee een con 17 10 2 Bill of materials von Taine 0807 PP FKM ccccccccessessseseesecereereeseeereeeeenreersenneee 18 10 3 Bill of materials von Taine 0807 PVDF FKM cee n 18 10 4 Bill of materials von Taine 0807 PP EPDM en n 19 10 5 Bill of materials von Taine 0807 PVDF EPDM rennes 19 11 RN E 20 11 1 Dimensional drawing of von Taine 0807 PP and PVDF een 20 TL2 Characleristie CNRS eee 21 131 3 MOTO dala SNOG ee de ee 22 11 4 EC Declaration of Conformity nennen 23 ProMinent Page 4 Operating instructions ProMinent von Taine 0807 PP PVDF 1 General information The pump may only be used in the range of applications authorized by the manufacturer In case of modified Operating conditions please consult your supplier and or the manufacturer 1 1 Authorized use of the pump e Delivery of low viscosity liquids resembling water
7. 000 3000 4000 5000 6000 7000 oO F rderleistung capacity l h 40 30 20 10 Wirkungsgrad efficency 96 1000 2000 3000 4000 5000 6000 7000 oO F rderleistung capacity l h Page 21 ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF 11 3 Motor data sheet Motor Datenblatt Motor data sheet Fiche technique pour moteur Motor Typ motor type type du moteur Maschinenart type of machine d signation Bauform mounting construction Bemessungsleistung rated output puissance nominale Schutzart protection class degr de protection Bemessungsspannung rated voltage tension nominale Bemessungsstrom rated current courant nominal Bemessungsfrequenz rated frequency fr quence nominale Bemessungsdrehzahl rated speed vitesse nominale Pumpentyp pump type type de pompe Anmerkung comment remarque ProMinent Dosiertechnik GmbH 69123 Heidelberg Germany ProMinent D102 A 32 2 Leistungsfaktor cosy power factor facteur de puissance 3 ph Motor Wirkungsgrad efficiency rendement IM B14 Warmeklasse temperature class classe d isolement 250 W Anzugsstrom starting current courant de d marrage IP55 Anzugsmoment starting torque couple de d marrage Kippmoment 230 400 V pull out torque couple de d crochage 1 1 0 65 A Umgebungstemperatur ambient temperature temp rature ambiante 50Hz Schaltung connect
8. ProMinent Operating instructions Magnetically coupled centrifugal pump ProMinent von Taine 0807 PP and PVDF von Taine 0807 PP von Taine 0807 PVDF 0807 PP FKM L 0807 PVDF FKM LJ 0807 PP EPDM LJ 0807 PVDF EPDM Serial No Please enter type serial number of the pump here Please read the manual instructions completely before bringing the machine into service Do not throw it away Damage caused by an operator s error will cancel the right to all warranty claims Part No 987045 ProMinent Dosiertechnik GmbH 69123 Heidelberg Germany BA vT 009 03 06 GB Imprint Imprint Operating instructions Magnetically coupled centrifugal pump ProMinent von Taine 0807 PP and PVDF ProMinent Dosiertechnik GmbH 2010 ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 69123 Heidelberg Germany info prominent de www prominent de Specifications subject to change without notice Printed in Germany ProMinent Page 2 Table of contents TABLE OF CONTENTS 1 General information 2 2u0 22 n00n000n0nn0n ann nun nun nun nun ann nun nun nun nun nnn nun nun nun 5 1 4 Authorized use of the pump iii 5 UI MEE eU veles u m 5 Z DE ETE 5 2 1 Identification of safety instructions in the operating manual 5 2 2 Qualification and training of operating personnel 6 2 3 Hazards in the event of non compliance with safet
9. UMA 05 0050 101 suction flange PVDF PUMA 05 0050 083 center shaft 30mm PUMA 10 0110 002 impeller 83 2 5 2mm PVDF Page 19 ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF 550 2 PUMA 05 0050 115 redanguarwasher _ 554 6 PUMA 00 0090 150 plain washer 26 4 DINT25 inox 800 1 PUMAO0 0250 004 motor250W 230400V SOHz drive magnet 15 18S shaft 14mm as 901 1 6 PUMA 05 0050 110 hexagon head cap screw M6x45 DIN931 inox 940 1 PUMA 00 0370 028 feather 5x25x5 Subject to technical alteration 11 Appendix 11 1 Dimensional drawing of von Taine 0807 PP and PVDF Druckseite Pressure side O RING 26x3 5 Sougseite Suction side D RING 30x3 G Aussengewinde male thread Technische nderungen vorbehallenl Technicol design may be subject io change ProMinent Page 20 Operating instructions ProMinent von Taine 0807 PP PVDF 11 2 Characteristic curves von Taine 0807 PP PVDF 8 0 1 9 7 0 1 8 wv 6 0 17 E 2 o 50 16 9 D 40 Dichte density 145 2 o C 5 e 30 14 2 I 1 3 9 po A 1 0 1 2 NPSH 0 0 1 1 0 1000 2000 3000 4000 5000 6000 7000 Forderleistung capacity l h 250 230 210 190 170 150 130 110 90 70 50 Motorleistung motor output W 1000 2
10. WC Maximum system 2 5 bar 3 5 bar 2 5 bar 3 5 bar pressure at 20 C Electrical data Motor output 250 W 250 W 250 W 250 W 230 400 230 400 230 400 230 400 Rated voltage 50 uz V Rated current sonz A 1 1 0 65 1 1 0 65 1 1 0 65 1 1 0 65 No of revolutions 5o uz 2 60 2 60 2 60 2 60 rpm Protection class IP 55 IP55 IP 55 IP55 80 C 95 C 80 95 C the medium C 0 Tl c et gt D Q Q er Q C C 0 D ZIZ lt 3 09 9 CO o Xx X D ce D otitc 3 3 E BE D jio o Oo Q o 9 a z lt O Z D X 3 c Q D 5 Li r lt O Mak Bak black black white i i 1 2 1 8 kg dm 1 2 1 8 kg dm 1 2 1 8 kg dm 1 2 1 8 kg dm the medium Bearing oxide ceramic oxide ceramic oxide ceramic oxide ceramic oxide ceramic oxide ceramic oxide ceramic oxide ceramic 410 UO s TA ce 3 O O nlo y s u D a 5g o 7 Q OQ p D 3 lt 5 D lt c 5 F ing impeller teflon graphite 283x138x185 283x138x185 283x138x185 283x138x185 mm ProMinent Page 16 UO OIOI JH 3 ogg OD 5 E o o 3 O gt 3 3 D 3 2 O0 r lt x O E x L Operating instructions ProMinent von Taine 0807 PP PVDF 10 Spare parts 10 1 Exploded view Page 17 ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF 10 2 Bill of materials von Taine 0807 PP FKM
11. earings center shaft and thrust rings are also designed for continuous operation they should periodically be inspected for choking If dirty silty or crystallising fluids are delivered then the pump should be inspected Page 10 Operating instructions ProMinent von Taine 0807 PP PVDF WARNING Make sure there are no magnetisable metal particles in the working area if you assemble or disassemble the pump Page 11 When the complete head of the pump is assembled or disassembled magnetic forces can cause serious injury Check the static sealings in regular intervals and replace them if necessary ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF 7 3 Disassembly of the pump 1 Remove the 6 screws 901 1 in the pump 2 Take the suction flange 162 off the pump housing 101 housing 161 Pull the impeller with the impeller magnet 230 847 1 and the center shaft 211 out of the magnet deviding housing 161 Required tool fork or ring spanner No tools required flange 162 magnet deviding housing 161 Required tool center shaft 211 Required tool center shaft 211 ProMinent Page 12 Operating instructions ProMinent von Taine 0807 PP PVDF 7 4 Re assembly of the pump 1 Install bearings 310 1 and 310 2 to 2 Make sure that the impeller with impeller impeller magnet 847 1 and impeller magnet 230 847 1 and bearings 230 310 1 310 2 installed prope
12. ents have been compiled by Date Manufacturer Signature Details of the signatory Circulation pump vonTAINE refer to nameplate on the device EC Machinery Directive 2006 42 EC EC Low Voltage Directive 2006 95 EC EC EMC Directive 2004 108 EC EN ISO 12100 1 EN ISO 12100 2 EN 809 Norbert Berger Im Schuhmachergewann 5 11 DE 69123 Heidelberg a SD wa E Put x P f emo VU am o alu iunii alm era JH qu EE 04 01 2010 Joachim Schall Head of Research and Development Pr Minent Anschriften und Liefernachweis durch den Hersteller Addresses and delivery by the manufacturer Adresses et liste des fournisseurs fourniesa par le constructeur Para informase de las direcciones de los distribuitores dirigirse al fabricante ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 e 69123 Heidelberg Germany Tel 49 6221 842 0 Fax 49 6221 842 419 info prominent de www prominent de ProMinent
13. hine plant Failure of specified procedures of maintenance and repair Exposure of people to electrical mechanical and chemical hazards amp Endangering the environment owing to hazardous substances being released 2 4 Compliance with regulations pertaining of safety work When operating the pump the safety instructions contained in this manual the relevant national accident prevention regulations and any other service and safety instructions issued by the plant operator are to be observed ProMinent 2 5 Safety instructions relevant for operation f hot or cold machine components involve hazards they must be guarded against accidental contact Guards for moving parts e g coupling must not be removed from the machine while in operation Any leakage of hazardous e g explosive toxic hot fluids must be drained away so as to prevent any risk occurring to persons or the environment Statutory regulations are to be complied with Hazards resulting from electricity are to be precluded see for examgple the VDE Specifications and the bye laws of the local power supply utilities 2 6 Safety instructions relevant for maintenance inspection and assembly work It shall be the plant operators responsibility to ensure that all maintenance inspection and assembly work is performed by authorized and qualified personnel who have adequately familiarized themselves with the subject matter by studying t
14. his manual in detail Any work on the machine shall only be performed when it is at a standstill it being imperative that the procedure for shutting down the machine described in this manual be followed Pumps and pump units which convey hazardous media must be decontaminated On completion of work all safety and protective facilities must be re installed and made operative again Prior to restarting the machine the instructions listed under Initial commissioning are to be observed Page 6 Operating instructions ProMinent von Taine 0807 PP PVDF The pump is magnetically coupled Attention Coming in contact with permanent magnetic parts during repair or maintenance work dangerously exposes to magnetic forces which for example may influence pacemakers Keep your distance 2 Unauthorized alterations and production of spare parts Any modifications may be made to the machine only after concultation with the manufacturer Using spare parts and accessories authorized by the manufacturer is in the interest of safety Use of other parts may exempt the manufacturer from any liability 2 8 Unauthorized modes of operation The reliability of the machine delivered will be only guaranteed if it is used in the manner intended in accordance with clause 1 of this manual The limit values specified in the data sheet mut under no circumstances be exceeded 3 Transportation and storage 3 1 Transportation The
15. ion branchement 2760 U min Identcode rpm identcode t mn code d identification Kreiselpumpe mit Magnetkupplung Die Daten entsprechen den Angaben der Motorenhersteller Kenndaten funktionsgleicher Motoren anderer Hersteller ndern sich nur unwesentlich Angabe ohne Gew hr The data correspond to the details given by the motor manufacturers Ratings of motors with the same functions made by other producers show insignificant changes only This information is supplied without liability Les donn es techniques correspondent au descriptif du fabricant des moteurs Les donn es techniques de moteurs similaires chez d autres fabricants varient tr s peu Ces donn es sont d ordre g n ral Nr No Datum Date 05 12 2003 Page 22 We hereby declare Operating instructions ProMinent von Taine 0807 PP PVDF 11 4 EC Declaration of Conformity EC Declaration of Conformity ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5 11 D 69123 Heidelberg that the following designated product complies with the pertinent fundamental safety and health requirements of the EC Directive in terms of its design and construction and in terms of the version marketed by us This declaration loses its validity in the event of a modification to the product not agreed with us Description of the product Product type Serial no Pertinent EC Directives Applied harmonised standards in particular technical docum
16. pump housing parts are sealed by static o rings The impeller of the pump is a radial flow wheel Depending on the fluid to be delivered each component of the pump is available in various materials ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF NOTE The materials used are listed on the name plate or the delivery note 4 3 Materials Pump housing PP PVDF Impeller PP PVDF Impeller magnet PP PVDF Rear casing PP PVDF Bearing 5 Mounting and installation The pump should be installed at a place allowing easy access at all times Make sure to meet the following values Ambient temperature 10 C up to 40 C Humidity of the air 95 relative humidity non condensing 5 1 Examples of mounting he pump is set up to be mounted horizontally but may also be mounted vertically with the motor component pointing upwards This pump is not self priming and therefore requires a feed supply ProMinent 5 2 Hoses and tubes The cross sections of the tubes must correspond to the suction and delivery ports All suction and delivery tubes to the pump housing should be free of tensile stress The weight of the tubes must not rest on the housing WARNING Do not install any quick acting stop valves into the tubes Pressure jerks may damage the pump housing 5 2 1 The suction line The suction line must be a tube or hose which cannot be deformed by the
17. pump is delivered by the manufacturer in a ready to work state In the event of damages occurring during and due to transportation the forwarding agent must make a factual statement The pump should always be transported appropriately and according to the state of the art Page 7 3 2 Storage An eventual storage place must be absolutely dry Make sure that the interior of the pump is protected from pollutants 3 3 Ambient conditions required for transportation and storage Temperature range 10 C to 50 C Humidity of the air max 95 relative humidity non condensing 4 Functional characteristics 4 1 General description This magnetically coupled centrifugal pump type von Taine is a sucking single stage centrifugal pump made of plastics and designed in modular system for horizontal mounting The pump and electric motor are connected by a magnetic clutch which transmits the drive power to the impeller 4 2 Design The pump housing impeller impeller magnet and magnet deviding housing are made of plastics In the standard version the center shaft is constructed from oxide ceramic whereas the bearings are made of oxide ceramic The magnet deviding housing hermetically seals the fluid against all atmospheric influences Due to the magnetic power transmission the center shaft needs not to be sealed In contrast to mechanically or gland sealed pumps this system prevents any leakage of fluid at the shaft The
18. rities housing Magnetic clutch is opecific gravity and or Reduce the delivery rate use disengaged viscosity of the fluid is too a stronger magnetic clutch high and a more powerful motor Pump was switched off then The rotor should have switched on again before the stopped before the pump can rotor stopped be switched on again Motor is overheating Clogged ventilator cowl Clean the ventilator and the cowl Pump is working but not Gas accumulation in the lines Evacuate the lines delivering Too much flow noise Cavitation Increase the suction line cross section Delivery rate too low Suction and delivery line Increase the suction and cross sections are too small delivery line cross sections significant losses Valve is not entirely open Entirely open the valve Delivery rate too high Pump losses are less Install a flow control valve in significant than presumed the delivery line Page 15 ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF 9 Technical data Order No 1023090 1023096 1028568 V Pump type B ine ine PP FKM PVDF FKM PP EPDM PVDF EPDM O 2 gt D oO CO N lt O 2 gt D oO CO N lt O 2 gt D oO CO N lt O D oO CO N Hydraulic data Maximum flow 6600 I h 6600 I h 6600 I h 6600 I h Operating range 60 6600 I h 60 6600 I h 60 6600 I h 60 6600 I h Maximum head 7 9 mWC 7 9 mWC 7 9 mWC 7 9 m
19. rly rotates around the center shaft Required tool Lever press No tools required 3 Put the center shaft 211 into the thrust 4 Crosswise fasten the complete pump ring 314 2 of the pump housing 161 housing to the motor using 6 hexagon and fit the o ring 412 1 into the groove of head cap screws 901 1 the suction flange 162 hen slide the impeller with impeller magnet 230 847 1 installed onto the center shaft 211 and mount thrust ring 314 1 and suction flange 162 to it No tools required Required tool fork or ring spanner Page 13 ProMinent Operating instructions ProMinent von Taine 0807 PP PVDF WARNING Once the complete head of the pump has been assembled the impeller 230 and the impeller magnet 847 1 should be able to slide axially on the center shaft 211 e Any other repair than the replacement of worn parts should be done by an expert since inappropriate maintenance work usually results in unnecessary costs e Ifthe pump will not be in operation for a longer period of time it should be cleaned carefully Otherwise you risk that residues remaining in the pump may harden and jam the impeller once the pump is started again ProMinent Page 14 Operating instructions ProMinent von Taine 0807 PP PVDF 8 Troubleshooting Malfunction Causes Corrective action Pump does not work when No voltage Test the voltage switched on Impurities in the pump Remove the impu
20. terior components of the pump WARNING Always protect the pump from coarse impurities and magnetisable metal particles 6 3 Operation If the motor has been switched off by the motor protection switch proceed as follows Before switching on the motor again check whether the impeller rotates readily Make sure that the suction line and the pump housing are filled with fluid amp Switch on the motor If the pump only delivers for a short period of time and then stops delivering the magnetic clutch has been disengaged Proceed as described in chapter 8 below 6 4 Shutdown procedure amp Switch off the motor ProMinent Close all shut off devices n case some fluid remains within the pump secure the shut off devices to prevent an accidental opening 6 5 Safe disposal of waste parts This product as a whole as well as parts of it must be disposed of in an environmentally safe way WARNING Please comply with the respective regulations that are currently in force at your place especially with regard to electronic scrap As for Germany Used parts that have been cleaned will be accepted by the local public disposal sites 7 Maintenance 7 1 General information The pump is designed for continous operation and is therefore maintenance free 7 2 Preventive maintenance Clean the ventilator cowl at least once per month in order to prevent the motor from overheating Although b
21. y instructions 6 2 4 Compliance with regulations pertaining of safety work esseeeeseeseess 6 2 5 Safety instructions relevant for operation 6 2 6 Safety instructions relevant for maintenance inspection and assembly work 6 2 Unauthorized alterations and production of spare parts sseesseusse T 2 8 Unauthorized modes of operation 7 3 Transportation and Storage en asec VENE UON 7 5 OS PONa an ee ee T 32 POE ee ee ee ee ee 7 3 3 Ambient conditions required for transportation and storage T 4 Functional characteristics 2u 2002002n00n0nann nun nun ann nun ann nun en nnn nnn nnn nnn 7 AT SST CS SCID U CIN ie an ee 7 12 DESI ee ee ee ee eee er T 4 3 MAOTA a ee E E ee 8 5 Mounting and installation 2 20 2002000n00n0n ann nnun nun nun nun ann nun ann nun nun nnn nnn 8 9 1 Examples Of IMOUNUMG sun 8 5 2 Hoses and tubes euere em de es ee ne eee mn re 8 5 2 1 SCOR ale area 8 P2 EN ET Iate 8 5 3 Electrical CONNECTION oo o ER 8 6 Starting and shutdown procedures ceeeeeeeeeeeee nene nnn 9 61 Preparations TOF SAMI mine snce c adita ea E DUE conne im 9 6 2 Starting DiOCEQURS EE 10 603 OO AO aa E cn 10 64 Shutdown PFOCEAUFE um aan a na nenn era 10 6 5 Sale disposal Of

Download Pdf Manuals