Home
Thin Client Web – Stand-alone / Embedded Linux
Contents
1. 1 4 Overview 12 1 display Device type Front panel Side view TC12 S mse A A fy Stand alone Front design MSC Order code TC S KT LX 800 12 1 MSC 256 Web Add on unit fe Display 12 1 Depth 85 mm Dimensions 315 mm x 280 mm Mounting at support arm systems e g with aid of an adapter plate TC12 S 3 Stand alone Front design neutral Order code TC S KT LX 800 12 1 N 256 Web Display 12 1 Dimensions 315 mm x 280 mm Fig 1 2 Overview 12 1 display Rev 1 01 dated 24 7 2008 Page 7 of 84 Characteristics Ol TC Web Overview continuation 17 0 display Device type Front panel Side view TC17 S Stand alone Front design MSC Order code TC S KT LX 800 17 0 MSC 256 Web Add on unit 17 0 Depth 95 mm Mounting at support arm systems e g with aid of an adapter plate Display Dimensions 410 mm x 370 mm TC17 S Stand alone Front design neutral Order code TC S KT LX 800 17 0 N 256 Web Display 17 0 Dimensions 410 mm x 370 mm Fig 1 3 Overview 17 0 display Page 8 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Overview continuation Characteristics Accessories Several adapter plates and connector housings for the mounting of different systems on the rear of the TC are available Adapter plate TC
2. USB stick for booting on USB 1 port 0 Fig 3 5 USB stick for booting on USB 1 port 0 Ethernet network The TC can be connected to a computer network via the RJ 45 socket Ethernet Ethernet is a standard for local networks Twisted pair cables are used for networking the computers Rev 1 01 dated 24 7 2008 Page 25 of 84 Commissioning and Operating Ol TC Web 3 3 Operating the TC Example TC17 S stand alone The following is valid correspondingly for other versions MSC Touchscreen Membrane keyboard Fig 3 6 Front view e g TC17 S 3 344 Membrane keyboard Ke The membrane keyboard on the front panel contains i four function keys and the status LED Fig 3 7 Membrane keyboard Soft keyboard Touch calibration Tools Configuring the device parameters Operating the user software Stand by Pressing for more than 2 seconds causes a hardware reset Status LED red flashing failure green indication of operation alternately red green flashing Stand by mode display out Page 26 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Commissioning and Operating 3 3 2 Touchscreen The touchscreen is integrated in the display section of the front panel By touching the sensitive screen according to the represented functions on the display you
3. Interface Connector type Annotation USB port USB type A 4 pin 2 x on the front under the covering USB port USB type A 4 pin 2xon the rear Ethernet RJ 45 socket 8 pin on the rear MIC Input Mono Socket for switchboard plug 3 5 mm on the rear Audio Line Out Stereo Socket for switchboard plug 3 5 mm on the rear Fig 3 2 Connections to periphery Notice During operation Do not connect or disconnect any plugs When connecting peripheral devices pay attention to their industrial compatibility Configuration of the connections see identification label Terminals are standardized contacts with known default assignments Rev 1 01 dated 24 7 2008 Page 23 of 84 Commissioning and Operating Ol TC Web Identification label The identification label inside on the adapter plate or the connector housing _ Erdung aa 2 shows the configuration of the interfaces 2 Lose Bi ov va TI Ka Stereo Fig 3 3 Identification label Connector housing TC for support arm system according to VESA 100 standard IP 65 Example Connector housing TC with the connections 24 VDC and Ethernet 2 x USB Article no 6286139 Power Ethernet Fig 3 4 Connections at the connector housing 3 2 2 Peripherals Notice For the process operation external keyboard and external mouse must be provided with the CE mark for industrial environment External keyboard membrane keyboard and or touchscree
4. Cancel Submit Fig 4 11 Language setting German and English Presently language settings in German and English are available Page 38 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software 4 4 Connection establishment Different establishment options e Manually e Automatically e Automatically with short waiting time A connection must be projected in the connection configuration before it can establish a link to the server 4 4 1 Manual connection establishment At manual connection establishment the desired connection is selected in the display manager After verifying the password with OK the connection will be established EI Connection 1 Connection 2 8 Connection 3 8 Connection 4 Fig 4 12 Connection establishment Connections must be set Further connections can be set via connection configuration as described in the appropriate section in this chapter For this purpose every entry needs a password It is not possible to maintain several connections simultaneously and switch back and forth Switching to other URLs must be realized in the Web application The password dialog must be verified with OK even if no password is used Rev 1 01 dated 24 7 2008 Page 39 of 84 Operating system and Software Ol TC Web 4 4 2 Automatic connection establishment With automatic connection establishment the system will try to activate the configured connection immediately a
5. The max ambient temperature during operation must not exceed the value specified in the chapter Technical Data Ventilation The TC is a closed system There are no ventilation holes for the air exchange with the surrounding air The heat arising in the interior is dissipated to the environment by means of large area cooling fins Take care of a suitable air circulation Example TC12 S stand alone with adapter plate for VESA 100 The following is valid correspondingly for other versions Cooling fins Fig 2 1 Ventilation Page 12 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Installation 2 3 3 Installation position The vertical installation as well as deviations up to 30 in the below indicated directions are permitted For deviations from vertical installation it is to be considered that no accumulation of heat arises in the interior of the housing Example TC12 S stand alone with adapter plate The following is valid correspondingly for other versions 4x30 1 30 18 8 9 5 Fig 2 2 Permissible installation positions Rev 1 01 dated 24 7 2008 Page 13 of 84 Installation Ol TC Web 2 3 4 Mounting and sealing Stand alone Add on unit TC as an add on unit can be mounted at support arm systems of different manufacturers see in chapter Characteristics the section Overview For mounting at a housing couplin
6. Copyright c 1988 1989 1991 1994 1995 1996 1997 The Regents of the University of California All rights reserved Redistribution and use in source and binary forms with or without modification are permitted provided that 1 source code distributions retain the above copyright notice and this paragraph in its entirety 2 distributions including binary code include the above copyright notice and this paragraph in its entirety in the documentation or other materials provided with the distribution and 3 all advertising materials mentioning features or use of this software display the following acknowledgement This product includes software developed by the University of California Lawrence Berkeley Laboratory and its contributors Neither the name of the University nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission THIS SOFTWARE IS PROVIDED AS IS AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Rev 1 01 dated 24 7 2008 Page 83 of 84 Appendix Licensing Ol TC Web 7 5 ZLib Copyright Notation Copyright notice C 1995 2004 Jean loup Gailly and Mark Adler This software is provided as is without any express or implied warranty In no event will the authors be held liable for any damages arising from the use of this
7. Ol TC Web Appendix Licensing NO WARRANTY 11 BECAUSE THE PROGRAM IS LICENSED FREE OF CHARGE THERE IS NO WARRANTY FOR THE PROGRAM TO THE EXTENT PERMITTED BY APPLICABLE LAW EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND OR OTHER PARTIES PROVIDE THE PROGRAM AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE PROGRAM IS WITH YOU SHOULD THE PROGRAM PROVE DEFECTIVE YOU ASSUME THE COST OF ALL NECESSARY SERVICING REPAIR OR CORRECTION 12 INNO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING WILL ANY COPYRIGHT HOLDER OR ANY OTHER PARTY WHO MAY MODIFY AND OR REDISTRIBUTE THE PROGRAM AS PERMITTED ABOVE BE LIABLE TO YOU FOR DAMAGES INCLUDING ANY GENERAL SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PROGRAM INCLUDING BUT NOT LIMITED TO LOSS OF DATA OR DATA BEING RENDERED INACCURATE OR LOSSES SUSTAINED BY YOU OR THIRD PARTIES OR A FAILURE OF THE PROGRAM TO OPERATE WITH ANY OTHER PROGRAMS EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES END OF TERMS AND CONDITIONS Rev 1 01 dated 24 7 2008 Page 73 of 84 Appendix Licensing Ol TC Web How to Apply These Terms to Your New Programs If you develop a new program and you want it to be of
8. Qc Thin Client Web Stand alone Embedded Linux Operating Instructions Issue 1 01 24 7 2008 MSC Tuttlingen GmbH Rudolf Diesel StraBe 17 D 78532 Tuttlingen Tel 49 7461 925 200 Fax 49 7461 925 268 E Mail sales msc tuttlingen de www msc tuttlingen com MICROCOMPUTERS SYSTEMS COMPONENTS TUTTLINGEN GMBH Ol TC Web General Notice General Notice Safety guidelines This document contains notices which you should observe to ensure your own personal safety as well as to protect the product and connected equipment These notices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger Danger Caution Qiii Intended use i gt Rev 1 01 dated 24 7 2008 Immediate danger to life and limb of personnel and others Non compliance will cause death or serious crippling injury Hazardous situation to life and limb of personnel and others Non compliance may cause death or serious injury Potentially hazardous situation Non compliance may cause slight injury possible damage to property Notes on correct handling Non compliance may cause damage to the product and or to parts items in the vicinity Important information about the product the handling of the product or the part of the documentation onto which is supposed to be made especially attentive Environmental protection Non compliance may have an impa
9. Article no 6114674 Article no 6114795 Article no 6114796 VESA 100 Bernstein CS 2000 SL housing coupling Rittal CP S support arm system ROSE GT48 2 flange angle coupling Fig 1 4 O o H a N e gt Overview Accessories adapter plate Connector housing TC for support arm systems according to VESA 100 standard protection class IP 65 Article no 6286137 Article no 6286138 Article no 6286139 24 VDC and Ethernet without USB 24 VDC and Ethernet 1 x USB 24 VDC and Ethernet 2 x USB Rev 1 01 dated 24 7 2008 Fig 1 5 Overview Accessories connector housing Page 9 of 84 Characteristics Overview continuation Ol TC Web Accessories According to the demand a pedestal with suitable adapter is available for the fixing at the TC Pedestal for the fixing at a TC with adapter plate VESA 100 art no 6114674 for the fixing at a TC with connector housing art no 6286137 6286138 6286139 Pedestal TC VESA 100 Pedestal TC connector housing Article no 6286141 Article no 6286140 Page 10 of 84 Fig 1 6 Overview Accessories pedestal Rev 1 01 dated 24 7 2008 Ol TC Web Installation 2 1 2 2 2 3 Installation Unpacking and checking the delivery contents Unpacking Check the packaging of the TC for trans
10. 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software 4 1 Operating system and Software Software Version 1 03 Characteristics The TC Web terminal system offers up to four connections simultaneously Addressing the projected connections is carried out by the display manager Integration in the application itself is necessary if ending an active connection is desired With Web applications for instance this can be solved via Java Script function ExitBrowser respectively ExitWindow If the connection shall be switched within an application it must be realized through the application such as for Web applications by switching to a different URL The terminal system can be started with two different operation modes e Manual connection e Automatic connection In addition automatic connection features a timely delay offering the user the opportunity to manually interfere at the starting point e g for servicing The configuration level is selectable with the IP address of the terminal remotely by a Web browser Thus the system can be differently projected even with automatic operation The TC Web terminal family is supported by three connection journals from software version 1 03 Web incl Java support e Virtual Network Computing VNC Remote Desktop version 4 and 5 All connection types can be operated with manual or automatic start VNC and RDP are controlled at the point of connection est
11. C not connected COIN OD oa 2 o nmi N C not connected 5 3 8 Microphone input and audio output Two sockets for switchboard plug each 3 5 mm for microphone input mono and audio output stereo MIC Input e E Audio Line Out Mono o 0 Stereo Rev 1 01 dated 24 7 2008 Fig 5 2 Ethernet Microphone input and audio output Page 51 of 84 Technical Data 5 3 4 Interfaces at the connector housing USB 1 2 USB 2 Power d Ethernet Power 4 pin male connector to connect the 24 VDC supply voltage SACC DSI MS 4CON L180 SCO Pin Signal Phoenix Contact art no 1553459 B O n view plug side Fig 5 4 Recommended plug in connector Phoenix Contact Ol TC Web Connector housing Power Art no 1681127 SACC M12FS 4CON PG7 M 4 pin female M12 unshielded Screw connection standard Art no 1694295 SACC M12FS 4CON PG 7 SH 4 pin female M12 shielded Ethernet 8 pin socket to connect the Ethernet interface and the 24 VDC supply voltage Screw connection standard SACC DSI FS 8CON L180 SCO Pin Signal Phoenix Contact art no 1542774 1 4 2 3 4 TxD 5 RxD 6 TxD 7 view female side 8 RxD Fig 5 5 Connector housing Ethernet Recommended plug in connector Phoenix Contact Art no 1513334 SACC M12MS
12. License since you have not signed it However nothing else grants you permission to modify or distribute the Program or its derivative works These actions are prohibited by law if you do not accept this License Therefore by modifying or distributing the Program or any work based on the Program you indicate your acceptance of this License to do so and all its terms and conditions for copying distributing or modifying the Program or works based on it 6 Each time you redistribute the Program or any work based on the Program the recipient automatically receives a license from the original licensor to copy distribute or modify the Program subject to these terms and conditions You may not impose any further restrictions on the recipients exercise of the rights granted herein You are not responsible for enforcing compliance by third parties to this License Rev 1 01 dated 24 7 2008 Page 71 of 84 Appendix Licensing Ol TC Web 7 e c 10 Page 72 of 84 If as a consequence of a court judgment or allegation of patent infringement or for any other reason not limited to patent issues conditions are imposed on you whether by court order agreement or otherwise that contradict the conditions of this License they do not excuse you from the conditions of this License If you cannot distribute so as to satisfy simultaneously your obligations under this License and any other pertinent obligations then as a consequence you
13. OCA E E OET OEE EA TOETA 67 7 1 Licensing regulations E 67 7 4 1 Free software packages nri istne det det aeter oed ree vel dece e edel 67 7 1 2 General terms for disposal of software products sssssssssssssseeenneenes 68 7 1 3 Guarantee regulations for free software essent 68 7 2 GNU General Public License GPL Version 2 0 69 7 8 GNU Lesser General Public License LGPL Version 21 75 7 4 BSD Copyright Notation mr ete ene ee t e ted ea eia e ete 83 7 5 ZE Copyright Notation inter IC eee eL one RE ieee tha ei 84 Page 2 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Table of Figures Table of Figures Fig 1 1 Example for order Code eati tede ar ea ete e sa Ca eet rte oh eed 6 Fig 1 2 Overview 12 1 display iiiter P ace eta ee ether rd e sedet E anatase 7 Fig 1 3 Overmiew Te EE 8 Fig 1 4 Overview Accessories adapter platel nennen 9 Fig 1 5 Overview Accessories connector bhousing nnn 9 Fig 1 6 Overview Accessories Ipedestall AA 10 Fig 2 1 VE e IT 12 Fig 2 2 Permissible installation positions ccccceesecceceeeeeceeeeeseneeeeeeeseseenseeeseseeneesesseneeeeeneneeeeeeneees 13 Fig 2 3 MOUNTING and E UL e BEE 14 Fig 2 4 Connecting to 24 VDC power Supply sess nennt nnne nes 16 Fig 2 5 Pl g in connection for 24 VDO arte e e d e cte det b cte 17 Fig 3 1 Opening the device and closing it again 20 Fig 3 2 Gonnections to Derlphiery se nei
14. a free program by obtaining a restrictive license from a patent holder Therefore we insist that any patent license obtained for a version of the library must be consistent with the full freedom of use specified in this license Rev 1 01 dated 24 7 2008 Page 75 of 84 Appendix Licensing Ol TC Web Most GNU software including some libraries is covered by the ordinary GNU General Public License This license the GNU Lesser General Public License applies to certain designated libraries and is quite different from the ordinary General Public License We use this license for certain libraries in order to permit linking those libraries into non free programs When a program is linked with a library whether statically or using a shared library the combination of the two is legally speaking a combined work a derivative of the original library The ordinary General Public License therefore permits such linking only if the entire combination fits its criteria of freedom The Lesser General Public License permits more lax criteria for linking other code with the library We call this license the Lesser General Public License because it does Less to protect the user s freedom than the ordinary General Public License It also provides other free software developers Less of an advantage over competing non free programs These disadvantages are the reason we use the ordinary General Public License for many libraries However the Lesser license pro
15. alone TC12 S LX800 S Linux Front MSC 6309U39 1 TC S KT LX 800 12 1 MSC Web x D D 4 95 Front neutral 6309U39 2 TC S KT LX 800 12 1 N Web D D D D 4 95 Stand alone TC17 S LX800 D Linux Front MSC 6309U40 1 TC S KT LX 800 17 0 MSC Web X D D D 7 95 Front neutral 6309U40 2 TC S KT LX 800 17 0 N Web x X D D 7 95 SDRAM 256 MB Compact Flash card 512 MB see section General in this chapter Weight with adapter plate without connector housing on the rear Page 50 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web 5 3 External connections 5 3 1 USB ports 4 pin USB connector type A to connect USB peripheral devices USB Type A USB Meaning ZER 1 VCC USB Voltage supply 4 2 USB Data E 3 USB Data 1 4 GND Ground Note 2 x USB 2 0 at rear 5 3 2 Ethernet connection One Ethernet connection via 10Base T connector Ethernet 2 x USB 2 0 at front covering IP 65 The Ethernet controller supports transfer rates of 10 Mbit s and 100 Mbit s Technical Data Fig 5 1 USB 10Base T Pin Signal Meaning Input Output RJ 45 CAT5 TxD 10Base T Transmit Differential Output 10Base T Transmit Differential Output RxD 10Base T Receive Differential Input N C not connected TxD N C not connected RxD 10Base T Receive Differential Input N
16. demanded from the operator to carry out adequate measures O Especially for devices with 100 240 VAC supply Notice Device must only be connected to a socket outlet with grounding contact For complete disconnection from mains the power plug must be unplugged Danger Note Ensure that the socket outlet with grounding contact of the internal installation is freely accessible and is as close as possible to the device Caution For installation in a cabinet a central power disconnect switch must be provided pi The connector of the connection line to the supply voltage is a disconnecting appliance according to EN 60950 Pull the power plug before opening the device p Danger Especially for devices with 24 VDC supply Notice Device may be operated only with safe extra low voltage extra low function potential with safe disconnection The power transformer must correspond to the valid specifications Rev 1 01 dated 24 7 2008 Page 15 of 84 Installation Ol TC Web 2 5 Connecting to power supply Mains supply voltage 24 VDC 24 VDC 18 36 VDC supply for integrated DC DC transducer The voltage applied must meet the requirements for a safe extra low voltage SELV according to EN 60950 Attend to and polarity Before connecting to mains Does available voltage conform to the standard voltage requirement Functional grounding Connect grounding point with cabinet ground Fl
17. emulation 1000 milliseconds Cancel Submit Fig 4 7 Touch Settings Right mouse button simulating Works only if this function is supported by the application Rev 1 01 dated 24 7 2008 Page 35 of 84 Operating system and Software Ol TC Web 4 3 3 Network Behavior of the TC in the net needs to be configured in menu item Network The system can be used in the following operating modes e Automatic network configuration by DHCP e Manual network configuration Routing to different network segments can not be configured with the TC Status System Connections mm Exit Display Touch Network Passwords Update Host name DHCP Network configuration IP Address MEM Subnet mask Ir Standard Gateway 7 DNS Server fo Advanced Network Settings v DNS Timeout 2 DNS Attempts 2 Cancel Submit Fig 4 8 Network Configuration The HOST name can be assigned with both operating modes in DHCP operation it automatically can be transferred from the DHCP server Following values can be set for manual network configuration e IP Address e Subnet mask e Standard Gateway e DNS Server In case of network failure the reaction time can be optimized The number of inquiry attempts at a DNS server can be set with the Advanced Network Settings option for this reason see DNS Attempts Waiting time between attempts can be set via DNS Timeout parameter However the reaction time in the network
18. is subject to various factors so that the timeout value is not in accordance with the time value in seconds It is rather a matter of a time period which is influenced by the actual network structure Page 36 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software 4 3 4 Pass words The passwords for the individual connections can be entered in the menu Passwords Connections Display Touch Network Passwords Update admin Password 1 Password 2 Password 3 Password 4 Cancel Submit Fig 4 9 Passwords Entries Default value for admin no password 4 3 5 Update If desired the system can be updated with an USB memory medium delivered by MSC Tuttlingen GmbH After inserting the USB memory medium will automatically be mounted as drive Select the update image with button Browse Connections Display Touch Network Passwords Update Browse Update Fig 4 10 Update Select image and start mode By pressing the button Update the TC will go into update mode and will re start The system update will be conducted during the re start Rev 1 01 dated 24 7 2008 Page 37 of 84 Operating system and Software Ol TC Web 4 3 6 Language setting In this menu the language for the system configuration and the layout of the soft keyboard can be adjusted Connection Configuration Language system configuration English gt Keyboard layout English en us gt
19. may not distribute the Program at all For example if a patent license would not permit royalty free redistribution of the Program by all those who receive copies directly or indirectly through you then the only way you could satisfy both it and this License would be to refrain entirely from distribution of the Program If any portion of this section is held invalid or unenforceable under any particular circumstance the balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances It is not the purpose of this section to induce you to infringe any patents or other property right claims or to contest validity of any such claims this section has the sole purpose of protecting the integrity of the free software distribution system which is implemented by public license practices Many people have made generous contributions to the wide range of software distributed through that system in reliance on consistent application of that system it is up to the author donor to decide if he or she is willing to distribute software through any other system and a licensee cannot impose that choice This section is intended to make thoroughly clear what is believed to be a consequence of the rest of this License If the distribution and or use of the Program is restricted in certain countries either by patents or by copyrighted interfaces the original copyright holder who places the Program under this Lic
20. operate the computer for example through pressure on an indicated field Notice Do not use any metallic or peaked objects these could damage the touch surface 3 3 3 Cleaning Switch off the TC and all devices connected to it before starting the cleaning Notice Prerequisite for a proper maintenance of the device is that the device is cleaned regularly according to the following guidelines It is allowed to use only pure water if necessary with small additions of neutral detergents pH 5 8 Where appropriate with the aid of smooth not abrasive cloths rags or industrial cotton wool Violent rubbing is to be avoided The removal of greasy oily or sooty substances can be done with aromatic free terpentine substitute or isopropyl alcohol IPA Remains of adhesives silicone rubber or adhesive tapes etc can be removed also in this way It must not be used any solvents that contain esters ketones alcohols aromatics glycolic ether or halogenated hydrocarbons or the like Avoid scraping and abrasive agents Do not use any strongly acid or alkaline cleaning and wetting agents Never use detergents of unknown composition The detergents may have a maximum of 25 C Steam jet devices must not be applied Immediately after every cleaning process it is to be rinsed with pure cold water Rev 1 01 dated 24 7 2008 Page 27 of 84 Commissioning and Operating Ol TC Web This page is left intentionally blank Page 28 of
21. software Permission is granted to anyone to use this software for any purpose including commercial applications and to alter it and redistribute it freely subject to the following restrictions 1 The origin of this software must not be misrepresented you must not claim that you wrote the original software If you use this software in a product an acknowledgment in the product documentation would be appreciated but is not required 2 Altered source versions must be plainly marked as such and must not be misrepresented as being the original software 3 This notice may not be removed or altered from any source distribution Jean loup Gailly Mark Adler jloup gzip org madler alumni caltech edu Page 84 of 84 Rev 1 01 dated 24 7 2008
22. the intent is to exercise the right to control the distribution of derivative or collective works based on the Program In addition mere aggregation of another work not based on the Program with the Program or with a work based on the Program on a volume of a storage or distribution medium does not bring the other work under the scope of this License Page 70 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Appendix Licensing 3 You may copy and distribute the Program or a work based on it under Section 2 in object code or executable form under the terms of Sections 1 and 2 above provided that you also do one of the following a Accompany it with the complete corresponding machine readable source code which must be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange or b Accompany it with a written offer valid for at least three years to give any third party fora charge no more than your cost of physically performing source distribution a complete machine readable copy of the corresponding source code to be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange or c Accompany it with the information you received as to the offer to distribute corresponding source code This alternative is allowed only for noncommercial distribution and only if you received the program in object code or executable form with such an off
23. the greatest possible use to the public the best way to achieve this is to make it free software which everyone can redistribute and change under these terms To do so attach the following notices to the program It is safest to attach them to the start of each source file to most effectively convey the exclusion of warranty and each file should have at least the copyright line and a pointer to where the full notice is found lt one line to give the program s name and a brief idea of what it does gt Copyright C lt year gt lt name of author gt This program is free software you can redistribute it and or modify it under the terms of the GNU General Public License as published by the Free Software Foundation either version 2 of the License or at your option any later version This program is distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU General Public License for more details You should have received a copy of the GNU General Public License along with this program if not write to the Free Software Foundation Inc 51 Franklin Street Fifth Floor Boston MA 02110 1301 USA Also add information on how to contact you by electronic and paper mail If the program is interactive make it output a short notice like this when it starts in an interactive mode Gnomovision version 69 Copyright C
24. to each and every part regardless of who wrote it Thus it is not the intent of this section to claim rights or contest your rights to work written entirely by you rather the intent is to exercise the right to control the distribution of derivative or collective works based on the Library In addition mere aggregation of another work not based on the Library with the Library or with a work based on the Library on a volume of a storage or distribution medium does not bring the other work under the scope of this License You may opt to apply the terms of the ordinary GNU General Public License instead of this License to a given copy of the Library To do this you must alter all the notices that refer to this License so that they refer to the ordinary GNU General Public License version 2 instead of to this License If a newer version than version 2 of the ordinary GNU General Public License has appeared then you can specify that version instead if you wish Do not make any other change in these notices Once this change is made in a given copy it is irreversible for that copy so the ordinary GNU General Public License applies to all subsequent copies and derivative works made from that copy This option is useful when you wish to copy part of the code of the Library into a program that is not a library You may copy and distribute the Library or a portion or derivative of it under Section 2 in object code or executable fo
25. year name of author Gnomovision comes with ABSOLUTELY NO WARRANTY for details type show w This is free software and you are welcome to redistribute it under certain conditions type show c for details The hypothetical commands show w and show c should show the appropriate parts of the General Public License Of course the commands you use may be called something other than show w and show c they could even be mouse clicks or menu items whatever suits your program You should also get your employer if you work as a programmer or your school if any to sign a copyright disclaimer for the program if necessary Here is a sample alter the names Yoyodyne Inc hereby disclaims all copyright interest in the program Gnomovision which makes passes at compilers written by James Hacker signature of Ty Coon 1 April 1989 Ty Coon President of Vice This General Public License does not permit incorporating your program into proprietary programs If your program is a subroutine library you may consider it more useful to permit linking proprietary applications with the library If this is what you want to do use the GNU Lesser General Public License instead of this License Page 74 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Appendix Licensing 7 3 GNU Lesser General Public License LGPL Version 2 1 GNU LESSER GENERAL PUBLIC LICENSE Version 2 1 February 1999 Copyright C 1991 1999 Free Software Fou
26. 8CON PG9 M 8 pin male M12 unshielded Screw connection standard Art no 1511857 SACC M12MS 8CON PG 9 SH 8 pin male M12 shielded Screw connection standard Page 52 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Mechanical Dimensions 6 Mechanical Dimensions 6 1 TC with 12 1 display 6 1 1 Front Front design MSC Stand alone Add on unit 315 mm x 280 mm 12 1 display Membrane keyboard 4 function keys LED e Touchscreen 2x USB under covering Fig 6 1 TC12 S MSC Front Front design neutral e Stand alone Add on unit 315 mm x 280 mm 12 1 display Membrane keyboard 4 function keys LED e Touchscreen 2x USB under covering Fig 6 2 TC12 S neutral Front Rev 1 01 dated 24 7 2008 Page 53 of 84 Mechanical Dimensions Ol 6 1 2 Device dimensions TC12 S stand alone d y A Aw 2804 1 m Ss Ad LH EI S Jo et 3192 9 Q4 17 pi o nm Q E co N OU RL Page 54 of 84 TC Web Rev 1 01 dated 24 7 2008 Ol TC Web Mechanical Dimensions K d 1 815 1 General tolerances ISO 2768 mK Fig 6 3 TC12 S stand alone Device dimensions Note The mechanical dimensions of the TC12 S MSC and TC12 S neutral devices are identical The figure shows
27. AR PISTA SIS f E IN A Tonner 370 4 n n EA 8 CH O 3938 M 0 y p E o oO Q o 00 Page 58 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Mechanical Dimensions 370 7 F A 0 410 General tolerances ISO 2768 mK Fig 6 6 TC17 S stand alone Device dimensions Note The mechanical dimensions of the TC17 S MSC and TC17 S neutral devices are identical The figure shows TC17 S with MSC front design and the adapter plate for VESA 100 article no 6114674 on the rear Rev 1 01 dated 24 7 2008 Page 59 of 84 Mechanical Dimensions Ol TC Web 6 2 3 Adapter plate Note When selecting a housing coupling an equipment flange it is to be ensured that the tube internal diameter is at least 40 mm For specific standard flange systems there are appropriate adapter plates in the scope of supply see in this chapter the section Adapter plates TC for standard flange systems Possible standard flange systems Support arm system according to VESA 100 standard Rittal CP S support arm s
28. OU SHOULD THE LIBRARY PROVE DEFECTIVE YOU ASSUME THE COST OF ALL NECESSARY SERVICING REPAIR OR CORRECTION IN NO EVENT UNLESS REQUIRED BY APPLICABLE LAW OR AGREED TO IN WRITING WILL ANY COPYRIGHT HOLDER OR ANY OTHER PARTY WHO MAY MODIFY AND OR REDISTRIBUTE THE LIBRARY AS PERMITTED ABOVE BE LIABLE TO YOU FOR DAMAGES INCLUDING ANY GENERAL SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE LIBRARY INCLUDING BUT NOT LIMITED TO LOSS OF DATA OR DATA BEING RENDERED INACCURATE OR LOSSES SUSTAINED BY YOU OR THIRD PARTIES OR A FAILURE OF THE LIBRARY TO OPERATE WITH ANY OTHER SOFTWARE EVEN IF SUCH HOLDER OR OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES END OF TERMS AND CONDITIONS Rev 1 01 dated 24 7 2008 Page 81 of 84 Appendix Licensing Ol TC Web How to Apply These Terms to Your New Libraries If you develop a new library and you want it to be of the greatest possible use to the public we recommend making it free software that everyone can redistribute and change You can do so by per mitting redistribution under these terms or alternatively under the terms of the ordinary General Public License To apply these terms attach the following notices to the library It is safest to attach them to the start of each source file to most effectively convey the exclusion of warranty and each file should have at least the copyright line and a pointer to where the full
29. P gt cgi bin index All configuration issues described in section System configuration in this chapter can be conducted via remote access Note Calibration can be accessed remotely however it must be conducted at the terminal itself The terminal will reboot after ending the configuration Page 30 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software 4 2 Operating elements Choose between several options to operate the device Four function keys in front below the display Touchscreen integrated in display section Soft keyboard to be superimposed in the display Keyboard and mouse to be connected to the USB interfaces if required 4 2 1 Soft keyboard ab Fading in and out the soft keyboard mask be re ele Los ro dm Lee ro fro en ee x L 2 REG BE SERIE 005 IB T AS EI feos FUP UF fe Leen E CRE Jr Fig 4 2 Soft keyboard The keyboard layout is available in German and English AE Switching languages occurs in the system configuration range 4 2 2 Touch calibration Calibrating the touchscreen New calibration of the touchscreen occurs with execution of the dot calibration which is prompted by the display Storage occurs automatically Touch is already calibrated at delivery status Therefore usually no post calibration by the user is necessary Rev 1 01 dated 24 7 2008 Page 31 of 84 Ope
30. PC technology and automation Purpose These operating instructions are part of the Technical Documentation of the TC Thin Client They provide service personnel and system advisors with the information required to install commission operate and maintain the TC TC Web Operating Instructions Article no 69 00 134 Copyright MSC Tuttlingen GmbH 78532 Tuttlingen 2008 Subject to change without notice Page 4 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Characteristics 1 1 Characteristics Features Remote solutions are becoming more and more important for the operation and visualization of machines Particularly the central software installation and maintenance of a server lead to considerable cost savings compared to applications with several panel computers with complete installation In addition the increasing circulation of Web servers in PLC and SCADA systems lead to further savings for the client license costs Unit for usage at the machine on site Stand alone add on unit Mechanically stable aluminum housing Flange mounting for support arm and pedestal Protection class IP 65 all around Aluminum front panel surface powder coated Touchscreen analogue resistive four function keys LED TFT color display in different sizes and resolutions Cooling Fanless Supply voltage 24 VDC Base board for integration of CPU module at ETX form factor CPU Geode LX800 on ET e module SDRAM Compact Flash
31. Rev 1 01 dated 24 7 2008 Page 45 of 84 Operating system and Software Ol TC Web This page is left intentionally blank Page 46 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Technical Data 5 Technical Data 5 1 General Component Description Order code Basic system TC Stand alone Add on unit S Protection class IP 65 all around Cooling Fanless Housing well Aluminum Rear mounted part Aluminum Mounting Flange mounting for support arm or pedestal Front Aluminum front panel powder coated surface Membrane keyboard with 4 function keys Status LED printed in MSC design silk screen printing in RAL 5013 cobalt blue MSC neutral without silk screen printing N customer specific design Operating panel Membrane keyboard with 4 function keys KT Touchscreen analogue resistive Display 12 1 SVGA 800 x 600 pixel 112 1 Active matrix LCD 17 0 SXGA 1280 x 1024 pixel 17 0 TFT color Base board Board for integration of CPU module at ETX form factor CPU on ET e module Geode LX800 LX 800 Memory extension 256 MB SDRAM 256 Compact Flash 512 GB CF card Onboard graphics shared memory External interfaces 2 x USB 2 0 at front covering IP 65 2 x USB 2 0 at rear 1 x Ethernet 10 100 Base T MIC Input Mono Audio Line Out Stereo Operating system Operating system based on Embedded Linux Web Rev 1 01 date
32. TC Web Appendix Licensing GNU LESSER GENERAL PUBLIC LICENSE TERMS AND CONDITIONS FOR COPYING DISTRIBUTION AND MODIFICATION 0 This License Agreement applies to any software library or other program which contains a notice placed by the copyright holder or other authorized party saying it may be distributed under the terms of this Lesser General Public License also called this License Each licensee is addressed as you A library means a collection of software functions and or data prepared so as to be conveniently linked with application programs which use some of those functions and data to form executables The Library below refers to any such software library or work which has been distributed under these terms A work based on the Library means either the Library or any derivative work under copyright law that is to say a work containing the Library or a portion of it either verbatim or with modifications and or translated straightforwardly into another language Hereinafter translation is included without limitation in the term modification Source code for a work means the preferred form of the work for making modifications to it For a library complete source code means all the source code for all modules it contains plus any associated interface definition files plus the scripts used to control compilation and installation of the library Activities other than copying distribution and modification are no
33. TC12 S with MSC front design and the adapter plate for VESA 100 article no 6114674 on the rear Rev 1 01 dated 24 7 2008 Page 55 of 84 Mechanical Dimensions Ol TC Web 6 1 3 Adapter plate Note When selecting a housing coupling an equipment flange it is to be ensured that the tube internal diameter is at least 40 mm For specific standard flange systems there are appropriate adapter plates in the scope of supply see in this chapter the section Adapter plates TC for standard flange systems Possible standard flange systems Support arm system according to VESA 100 standard Rittal CP S support arm system Bernstein CS 2000 SL housing coupling ROSE GT48 2 flange angle coupling Page 56 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Mechanical Dimensions 6 2 TC with 17 0 display 6 2 1 Front Front design MSC e Stand alone Add on unit e 410 mm x 370 mm e 17 0 display Membrane keyboard 4 function keys LED e Touchscreen 2x USB under covering Fig 6 4 TC17 S MSC Front Front design neutral Stand alone Add on unit 410 mm x 370 mm e 17 0 display Membrane keyboard 4 function keys LED e Touchscreen 2x USB under covering Fig 6 5 TC17 S neutral Front Rev 1 01 dated 24 7 2008 Page 57 of 84 Mechanical Dimensions Ol TC Web 6 2 2 Device dimensions TC17 S stand alone zi UN PA
34. ablishment and during the established connection Connection monitoring can be configured with two different options 1 Endless connection establishment 2 Connection establishment for n attempts A waiting period should be configured between single attempts to avoid unnecessary system load Switch on behavior The TC Web automatically starts booting after power is supplied and shows a green LED signal in the front Previously the LAN connection has to be linked to the Ethernet interface for recognition while booting Keyboard and mouse can be connected to the USB ports if needed MIC input mono and audio line out stereo are available for microphone and speaker There is no On Off switch Rev 1 01 dated 24 7 2008 Page 29 of 84 Operating system and Software Ol TC Web Booting process The booting logo appears during the booting process The display manager is initiated after switching into graphic mode In basic condition of the device this is depicted as demonstrated in the window below Example Display manager after booting E Connection 1 O Connection 2 EI Connection 3 e Connection 4 Cancel TC Web based on Linux Fig 4 1 Display manager after booting Remote configuration The configuration desktop can be accessed remotely during ongoing operation For this purpose a minimal Web server is integrated in every terminal system Remote access is carried out via following address syntax http lt I
35. at pin 6 3x0 8 at the adapter plate on the rear of the housing View on the rear of the housing Example TC12 S stand alone with adapter plate for VESA 100 The following is valid correspondingly for other versions Grounding point Flat pin 6 3x0 8 Voltage supply 24 VDC A Note pin assignment waming Fig 2 4 Connecting to 24 VDC power supply Connection cable For connecting the power supply we recommend Cu wire 75 C Cross section 2 5 mm Tightening torque 0 5 0 6 Nm with screws at the plug component Page 16 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Installation 2 6 Plug in connection for 24 VDC on the rear of the housing Plug component FMC 1 5 2 ST 3 5 2 pin pitch 3 5 mm Phoenix Contact Fig 2 5 Plug in connection for 24 VDC Attach the supplied connector onto a 2 wire cable and plug it into the socket on the rear of the housing Consider and polarity Connect the supply cable to a 24 V supply voltage that meets the requirements for a safe extra low voltage SELV according to EN 60950 The device is ready for 24 VDC operation Plug in connection at the connector housing If a connector housing is attached on the rear the above described plug in connector is not accessible Placement and assignment of the connections for the 24 VDC power supply are to be found in the chapter Technical Da
36. card Onboard graphics shared memory Interfaces to peripherals 2x USB 2 0 at front covering IP 65 2x USB 2 0 at rear Ethernet RJ 45 socket 10 100 Base T Software Operating system based on Embedded Linux Web VNC client RDP applications Test certificate CE UL Recognized Component Rev 1 01 dated 24 7 2008 Page 5 of 84 Characteristics Ol TC Web 1 2 Use TC operation terminals are completely configured for most server environments e g RDP Web or extended configurations The connection to the server will be established via Ethernet The devices are characterized by high operational reliability at rough conditions The TC is a stand alone unit IP 65 all around and prepared for support arm or pedestal mounting By default it features four function keys 1 3 Nomenclature The identification of the different versions of TC type series depends on display size e manner of mounting The order code describes more in detail the respective equipment For example TC S KT LX 800 12 1 MSC 256 Web Operating system function DRAM in MB Front design Display size CPU version Operating panel Mounting Basic system Fig 1 1 Example for order code You will find the available components in the chapter Technical Data Each device is determined by an article number Page 6 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Characteristics
37. connection with Automatic login Rev 1 01 dated 24 7 2008 Page 41 of 84 Operating system and Software Ol TC Web 4 5 2 RDesktop connection Windows Terminal Services Configuration parameter Address Port Automatic Timed login Username Password Windows domain Connection retries Timeout monitoring Connection 1 Connection 2 Connection 3 Address msctutes2 Connection type RDP vj Username user Password password Domain tuttlingen Max Connection retries 0 endless Waiting time Connection Monitoring Activate autologin Timed login Bi Automatic login Connection 1 7 Cancel Submit Fig 4 14 Example for RDP connection Page 42 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software 4 5 3 VNC connection Configuration parameter Address Port e Automatic Timed login Connection retries Timeout monitoring Connection 1 Connection 2 Connection 3 Address 192 168 200 123 Connection type VNC sl Password password Max Connection retries 0 endless Waiting time Connection Monitoring Activate autologin Timed login h Automatic login Connection 1 gt Cancel Submit Fig 4 15 Example for VNC connection Rev 1 01 dated 24 7 2008 Page 43 of 84 Operating system and Software Ol TC Web 4 5 4 Configuring the VNC server Following open source products can be applied if there is no VNC server installe
38. cs being under that Protection class IP 65 of the housing is only guaranteed if the sealing on the rear mounted part of housing is not damaged during removal and fitting of the adapter plate and the sealing remains positioned correctly e In addition it is to be ensured that the required tightness is obtained when mounting the equipment flange at the adapter plate Page 14 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Installation 2 4 Providing readiness of operation Fail safe connections for ensuring trouble free operation Use only shielded cables and metallic connectors for all signal connections Screw down or lock all plug connectors This improves the electrical shielding Do not install signal lines in the same cable ducts as high voltage lines Before commissioning the system all cable connections must be tested It has to be guaranteed that all voltages and signals correspond to the required values Safe derivation of electric malfunctions Device and cabinet are to be connected on maximally short way with a central grounding point Use a connection with maximally low impedance between device and cabinet Carry out the grounding connection with green yellow cable with at least 2 5 mm cross section Caution p Interference emission according to EN 55022 1998 A1 2000 A2 2003 Class A This is a device of the class A This device can cause interferences in the living area in this case it can be
39. ct on the environment The products of MSC Tuttlingen GmbH may only be used for the applications described in the technical documents and only in connection with devices or components from other manufacturers which have been approved or recommended by us Start up must not take place until it is established that the machine which is to accommodate this component conforms to the guideline 98 37 EC This product can only function correctly and safely if it is transported stored set up and installed correctly and operated and maintained as recommended General Notice Ol TC Web Qualification of personnel Only qualified personnel may carry out the following activities on the products installation commissioning operation maintenance Qualified persons in accordance with the safety guidelines are defined as persons who are authorized to commission to ground and to tag circuits equipment and systems in accordance with established safety practices and standards Disclaimer of liability We have checked the contents of this document for agreement with the hardware and software described Since deviations cannot be precluded entirely we cannot guarantee full agreement However the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions Suggestions for improvement are welcomed EMC directive 2004 108 EC The following applies to this product of MSC Tuttlingen GmbH TC complies wi
40. d 24 7 2008 Page 47 of 84 Technical Data Ol TC Web Supply voltage 24 VDC 18 36 VDC SELV Power consumption typ Device with 12 1 display 30W Device with 17 0 display 70W max 75W Mechanical dimensions depending on device variation see chapter Mechanical Dimensions Weight depending on equipment see section Device specific in this chapter Ambient temperature Operation vertical installation with natural convection Device with 12 1 display basic type of configuration 0 C to 50 C Device with 17 0 display 0 C to 45 C Storage 20 C to 60 C Relative humidity 50 max at 40 C non condensing 90 max at 20 C non condensing Ambient air free of corrosive gases Oscillation load in operation according to EN 60068 2 6 10 Hz to 58 Hz 0 3 mm pp 58 Hz to 150 Hz 2g Shock load in operation according to EN 60068 2 27 15g 11 ms 3 shocks EMC directive 2004 108 EC Testing for EC conformity Interference emission according to EN 55022 1998 A1 2000 A2 2003 Class A Interference resistance according to EN 55024 1998 A1 2001 A2 2003 and EN 61000 6 2 2001 Endurance test 24 h Burn in Test certificate CE UL Recognized Component Notice The voltage applied must meet the requirements for a safe extra low voltage SELV according to EN 60950 Page 48 of 84 Re
41. d on a Windows computer Ultra VNC version 1 02 TightVNC version 1 3 9 Please install these products according to the appropriate product documentation The screen update behavior of the server must be configured as follows to ensure correct transmission of quick data modifications at the main computer to the client Note Settings concerning the display update can influence the system performance substantially Video Hook Drivers offered for each server product can have a positive impact on the system behavior However the entire system must be adjusted individually Ultra VNC server Agi xl M Server Screen Updates Handling v Poll Full Screen Ultra Fast v Poll Foreground Window Poll Console Windows Only Poll Window Under Cursor Poll On Event Only IV System HookDIl v Video Hook Driver VC CHECK Low Accuracy Turbo Speed r Single Window Sharing Share only the Server Window Named OK Apply Cancel Fig 4 16 Ultra VNC server Page 44 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software TightVNC server IV Pall oreground window T Pall console windows only Pall window under cursor E Poll on event received only op Fig 4 17 TightVNC server Note The value Polling cycle can be adjusted for quick system alterations as well Though this is not recommended in terms of higher system load
42. e Therefore certain precautionary measures are necessary when handling these modules Please refer to the directive for Electrostatically Sensitive Devices ESD guideline Before plugging in or unplugging any components disconnect the TC from the power supply Before plugging in the connection cables the static charge of your body the TC and the cables must be brought to the same level To do this briefly touch the metal housing Discharge the electrostatic charge from tools you are using Wear a grounding strip when handling components Leave components in their packaging until they are to be installed Components should only be held at the edges never touch connection pins and conductive tracks Never operate the TC with the housing open Notice Only service personnel is allowed to open the TC Rev 1 01 dated 24 7 2008 Page 19 of 84 Commissioning and Operating Ol TC Web 3 1 2 Opening the device and closing it again Notice Only remove the adapter plate for exchanging Compact Flash card and battery TC should remain closed Do not loosen any further screws at the housing Example TC12 S stand alone with adapter plate for VESA 100 The following is valid correspondingly for other versions Rear mounted part of the housing Fig 3 1 Opening the device and closing it again Removing the adapter plate Before opening Separate the device from sup
43. e TC Web device generation includes the following function packages GRUB Bootloader Version 0 97 Linux Kernel 2 6 21 6 LibC Version 2 3 BusyBox 1 2 0 Automount 5 0 2 XOrg 7 1 Mozilla Firefox 2 0 0 10 VNC based on TightVNC 1 3 9 RDesktop 1 5 0 Sun Java SE Runtime 1 6 1 5 1 4 optionally A detailed list of all modules can be inquired with your responsible sales commissioner Notice These programs were developed by third parties If you want to use free software for more than the program sequence intended by MSC Tuttlingen GmbH you can acquire rights of use from the authors or other initiators of this software in compliance with license regulations The source code of the free software with appropriate license texts and author notations can be inquired with your responsible sales commissioner within five years after acquiring this product Rev 1 01 dated 24 7 2008 Page 67 of 84 Appendix Licensing Ol TC Web General terms for disposal of software products This software is protected by national and international copyright and contracts Unlawful copying and distribution of this software or parts of it are liable to prosecution This will result in prosecution according to civil and criminal law and lead to severe penalty and or compensation for damages Please read the valid license regulations for this software before installation and use Every other use of this software is permitted with the appropriate syst
44. ecking the delivery contents sess 11 2 2 Storing and transporting nr 11 2 3 InstalliNd EE 11 2 3 1 Rule 12 2 3 2 Ventilation em 12 2 3 3 Installation ele Le EE 13 2 3 4 Mounino and seal EE 14 2 4 Providing readiness of operation ssssssssssssesesseseeeeeeen eene nnne nennen nnns nnne 15 2 5 Connecting to power Supp 16 2 6 Using peripheral devices nnne nrnr et ren nen snnt inns 17 3 Commissioning and Operating unrraeunnneannnnnnnnnannnnnannnnnnnnnnannnnnannnnnnnnnnnnnnnannnnnnnennnnnnnannnnnnn 19 3 1 Expanding AE 19 3 1 1 General requirements ssssssssssssssssseseeeee enne enne nnns en nennen sn nnns sn nrt rennen eser sitne en nenas 19 3 1 2 Opening the device and closing it again 20 3 1 3 BacksUp patery ee ae exe e a dg AL eI di ds 21 3 1 4 Flash memory a adst un A De eei Nai ed 22 3 2 Connecting peripheral devices enne en nennen sns sitne 23 3 2 1 Interfaces ue dee Lads Hep e He d edi e e He eee i eas 23 ACCESS AO pons ccm E RR E E rug a ue He a Ed e Pa du ada Edd 23 Identification RL 24 Connector housing TC for support arm system according to VESA 100 standard IP 65 24 3 2 2 Menit 24 Re m E 24 MIDII Sr EE 24 Plugging the keyboard and MOUSE enne nemen enne nnn nnns 25 Booting from USB enk cise arden eaa ca dg eub ede dae edd e Heat d He itc 25 Ethernet network eeu eee wel ak e teo o He uda he a eed 25 3 3 Operating the TG cede da Ue b e i a
45. em plattform of MSC Tuttlingen GmbH only Guarantee regulations for free software The use of the free software included with this product exceeding the program sequence intended by MSC Tuttlingen GmbH is subject to own risk That means no guarantee claims against MSC Tuttlingen GmbH can be raised MSC Tuttlingen GmbH offers no technical support for the product if the product is used with altered software The listed license regulations include notes regarding the guarantee of authors and other lawful holders of the free software Also there are no guarantee claims against MSC Tuttlingen GmbH if a deficiency of the product rests or could rest upon the fact that the user has altered the program or configuaration Page 68 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Appendix Licensing 7 2 GNU General Public License GPL Version 2 0 GNU GENERAL PUBLIC LICENSE Version 2 June 1991 Copyright C 1989 1991 Free Software Foundation Inc 51 Franklin Street Fifth Floor Boston MA 02110 1301 USA Everyone is permitted to copy and distribute verbatim copies of this license document but changing it is not allowed Preamble The licenses for most software are designed to take away your freedom to share and change it By contrast the GNU General Public License is intended to guarantee your freedom to share and change free software to make sure the software is free for all its users This General Public License applies to mos
46. ense may add an explicit geographical distribution limitation excluding those countries so that distribution is permitted only in or among countries not thus excluded In such case this License incorporates the limitation as if written in the body of this License The Free Software Foundation may publish revised and or new versions of the General Public License from time to time Such new versions will be similar in spirit to the present version but may differ in detail to address new problems or concerns Each version is given a distinguishing version number If the Program specifies a version number of this License which applies to it and any later version you have the option of following the terms and conditions either of that version or of any later version published by the Free Software Foundation If the Program does not specify a version number of this License you may choose any version ever published by the Free Software Foundation If you wish to incorporate parts of the Program into other free programs whose distribution conditions are different write to the author to ask for permission For software which is copyrighted by the Free Software Foundation write to the Free Software Foundation we sometimes make exceptions for this Our decision will be guided by the two goals of preserving the free status of all derivatives of our free software and of promoting the sharing and reuse of software generally Rev 1 01 dated 24 7 2008
47. er in accord with Subsection b above The source code for a work means the preferred form of the work for making modifications to it For an executable work complete source code means all the source code for all modules it contains plus any associated interface definition files plus the scripts used to control compilation and installation of the executable However as a special exception the source code distributed need not include anything that is normally distributed in either source or binary form with the major components compiler kernel and so on of the operating system on which the executable runs unless that component itself accompanies the executable If distribution of executable or object code is made by offering access to copy from a designated place then offering equivalent access to copy the source code from the same place counts as distribution of the source code even though third parties are not compelled to copy the source along with the object code 4 You may not copy modify sublicense or distribute the Program except as expressly provided under this License Any attempt otherwise to copy modify sublicense or distribute the Program is void and will automatically terminate your rights under this License However parties who have received copies or rights from you under this License will not have their licenses terminated so long as such parties remain in full compliance 5 You are not required to accept this
48. fter booting If the connection fails an error message appears Select following options here New attempt to establish a connection Switching to system configuration e Exit If switching to another connection shall be possible despite automatic login e g for servicing it can be solved with time controlled login For this purpose a timeout value will be configured after automatic login is started During this timeout period the configuration or an alternative connection can be selected Page 40 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software 4 5 4 5 1 Connection configuration Single connections are configured via following parameters 1 Address 2 Connection type In addition to connection types VNC and RDP the parameters connection attempts waiting time will be allocated for the configuration of the control strategy If a different port as the standard port is used for the communication interface at the host computer this port can be added with 7 separated from the address e g Web visualization via port 8080 Address http 192 168 100 27 8080 webvisu htm Web connection Configuration parameter Address Port e Automatic Timed login Connection 1 Connection 2 Connection 3 Address http www msc tuttlingen de Connection type Web gt Activate autologin Y Timed login u Automatic login Connection 1 7 Cancel Submit Fig 4 13 Example for Web
49. g 5 4 Gonnector housing POWE Leica rmt e e dte e ends FL rae C Ee aia 52 Fig 5 5 Connector housing Ethernet acia 52 Fig 6 1 TO12 S4 MSO e EE 53 Fig 6 2 T amp 12 S neutral Front E 53 Fig 6 3 TC12 S stand alone Device dimensions nens 55 Fig 6 4 TG317 S MSO EEODE a Asse tte e cte trei tek ted ie t ue 57 Fig 6 5 TO17 S neutral Erotica eerte ee crece rate tekst 57 Fig 6 6 TC17 S stand alone Device dimensions nns 59 Fig 6 7 Adapter plate TC for support arm system according to VESA 100 standard 61 Fig 6 8 Adapter plate for Rittal CP S support arm svsiem anar cnn 62 Fig 6 9 Adapter plate for Bernstein CS 2000 SL housing coupling esses 63 Fig 6 10 Adapter plate for ROSE GT 48 2 flange angle coupling ssesesssss 64 Fig 6 11 Connector housing TC for support arm systems according to VESA 100 standard IP 65 65 F 19 6 12 sPedestal TO VESA iter beet eb e AU i Ent ene portae lindos 66 Rev 1 01 dated 24 7 2008 Page 3 of 84 Table of Figures Ol TC Web Note These TC Web operating instructions describe the standard versions of the TC Web Thin Client Customized variants are also based on these components If necessary a description of the significant special particulars is attached Please read the operating instructions before the first use and keep them carefully for the later use They are written for customers with prior knowledge in
50. g an equipment flange the adapter plate on the rear of the housing is removable The dimensions of the adapter plate you will find in the chapter Mechanical Dimensions in the section Adapter plates TC for standard flange systems Loosen the four screws M5x8 hexagon socket of the adapter plate Remove the plate from the rear mounted part of housing Use the appropriate adapter plate for the standard flange system or if not appropriate drill holes into the adapter plate for the connection with the housing coupling e Attach the housing coupling to the adapter plate e Screw on the adapter plate with mounted equipment flange on the rear mounted part of the housing A connector housing for the fixing at a support arm system according to VESA 100 standard is an alternative to the adapter plate Connectors with protection class IP 65 are wired to outside for 24 VDC Ethernet and USB Example TC12 S stand alone The following is valid correspondingly for other versions Rear mounted part of the housing Rear mounted part of the housing M5x8 screw Hexagon socket 4x Connector housing with special bolts M5 Adapter plate Fig 2 3 Mounting and sealing Notes e When mounting an adapter plate with attached housing coupling it is absolutely to be noted that the fixing elements of the coupling on the adapter plate do not contact the electroni
51. gram or any part thereof to be licensed as a whole at no charge to all third parties under the terms of this License C If the modified program normally reads commands interactively when run you must cause it when started running for such interactive use in the most ordinary way to print or display an announcement including an appropriate copyright notice and a notice that there is no warranty or else saying that you provide a warranty and that users may redistribute the program under these conditions and telling the user how to view a copy of this License Exception if the Program itself is interactive but does not normally print such an announcement your work based on the Program is not required to print an announcement These requirements apply to the modified work as a whole If identifiable sections of that work are not derived from the Program and can be reasonably considered independent and separate works in themselves then this License and its terms do not apply to those sections when you distribute them as separate works But when you distribute the same sections as part of a whole which is a work based on the Program the distribution of the whole must be on the terms of this License whose permissions for other licensees extend to the entire whole and thus to each and every part regardless of who wrote it Thus it is not the intent of this section to claim rights or contest your rights to work written entirely by you rather
52. he work can be linked without the Library or if the work is itself a library The threshold for this to be true is not precisely defined by law If such an object file uses only numerical parameters data structure layouts and accessors and small macros and small inline functions ten lines or less in length then the use of the object file is unrestricted regardless of whether it is legally a derivative work Executables containing this object code plus portions of the Library will still fall under Section 6 Rev 1 01 dated 24 7 2008 Ol TC Web Appendix Licensing Otherwise if the work is a derivative of the Library you may distribute the object code for the work under the terms of Section 6 Any executables containing that work also fall under Section 6 whether or not they are linked directly with the Library itself 6 As an exception to the Sections above you may also combine or link a work that uses the Library with the Library to produce a work containing portions of the Library and distribute that work under terms of your choice provided that the terms permit modification of the work for the customer s own use and reverse engineering for debugging such modifications You must give prominent notice with each copy of the work that the Library is used in it and that the Library and its use are covered by this License You must supply a copy of this License If the work during execution displays copyright notices you must i
53. hese things To protect your rights we need to make restrictions that forbid distributors to deny you these rights or to ask you to surrender these rights These restrictions translate to certain responsibilities for you if you distribute copies of the library or if you modify it For example if you distribute copies of the library whether gratis or for a fee you must give the recipients all the rights that we gave you You must make sure that they too receive or can get the source code If you link other code with the library you must provide complete object files to the recipients so that they can relink them with the library after making changes to the library and recompiling it And you must show them these terms so they know their rights We protect your rights with a two step method 1 we copyright the library and 2 we offer you this license which gives you legal permission to copy distribute and or modify the library To protect each distributor we want to make it very clear that there is no warranty for the free library Also if the library is modified by someone else and passed on the recipients should know that what they have is not the original version so that the original author s reputation will not be affected by problems that might be introduced by others Finally software patents pose a constant threat to the existence of any free program We wish to make sure that a company cannot effectively restrict the users of
54. item Display e Screensaver active inactive Time to wait in minutes until the screensaver is being activated Screensaver mode e Brightness of back lighting 0 100 System Connections Display Touch Network Passwords Update Screensaver Time to wait in minutes Screensaver mode Brightness Mode Brightness 75 10 Cancel Submit Fig 4 6 Display Settings With function Screensaver mode the behavior of the screen can be configured for longer idle periods Two modes are being offered Screensaver mode Display Ol Brigthness 7 Se Mode Display Off Screen will be turned off can be activated again by pressing touchscreen Brightness Mode Back lighting of display will be dimmed The application is still visible Page 34 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software 4 3 2 Touch Touch devices of the TC system family are provided with an analogue resistive touch panel The associated touch controller can be put into different operating modes e Normal operation touch has full mouse functionality incl Drag amp Drop e Touch Down e Touch Up Deactivated Functionality of the Right mouse button can additionally be controlled by a time out value in Normal operation or Touch Down mode Connections Display Touch Network Passwords Update Touch operation mode Normal x Enable right click emulation Y Timeout value right click
55. ium if a supply voltage failure occurs The variable voltage in such an event causes uncontrolled writing to the storage medium data files may be overwritten or deleted UPS Uninterruptible Power Supply prevents loss of data Exchanging the Compact Flash card If data are destroyed on the Compact Flash card it is to be replaced by a new one that can be got by MSC Tuttlingen GmbH To replace the Compact Flash card follow these steps Observe the precautions in section General requirements Open the housing as described in section Opening the device and closing it again Remove the damaged Compact Flash card and insert the new card Close the TC again as described in section Opening the device and closing it again Page 22 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Commissioning and Operating 3 2 Connecting peripheral devices 3 2 1 Interfaces Access to ports Connections to peripheral devices are placed on the front under the covering and on the rear of the housing Example TC12 S stand alone with adapter plate for VESA 100 The following is valid correspondingly for other versions Front view Rear view a ASC a Ta IN Ethernet Iu Grounding Audio Line Out Stereo
56. l Data E 47 5 1 erac 47 5 2 Device spe ific ies n 50 5 3 External CONMECHONS een er EE Eeer 51 5 3 1 USB POrts EE 51 5 3 2 Ethernet Connection ec deco e ig teca e ites atas duo eu eod es edd 51 5 3 3 Microphone input and audio output eee eee eeeee ce eee ae ee eee ae ee ee eaaeeeeeeaaeeeeeeaaeeeeeeeaaeeeeeeaeeeeee 51 5 3 4 Interfaces at the connector bousing cnet nono na nano coronar anna cnn rra rara 52 Power dee aa en N ne 52 NET EE 52 6 Mechanical Dimensions ccccceeeceeeeeeeeeeeeeee seen nennen nnne nennen nennen seen seee insani tria nnmnnn inan nnn nnn 53 6 1 TO with 12 1 display tette t eee ua D ned ede mee enr eoa fe cass 53 6 1 1 dinh das D at aati 53 6 1 2 Device dImenislOris ed oie toi lebte EE 54 Be KE ME nie De TWEET 54 6 1 3 Adapter EE 56 6 2 TEwith 17 0 display TEE 57 6 2 1 dient Pm 57 6 2 2 Device dIMENSIONS sauces ote oid ee eti EE 58 TG17 S standsalone 5 tif Pe Pene nee nate teilen iiit b ariel 58 6 2 3 Adapter MEE 60 6 3 Adapter plates TC for standard flange svsiems eene 61 6 3 1 Support arm system according to VESA 100 standard 61 6 3 2 Rittal CP S support arm system 62 6 3 3 Bernstein CS 2000 SL housing coupling sse eee 63 6 3 4 ROSE GT48 2 flange angle coupling coooccconociconocacancccnonannanann conc c cnn rc nano nana cnn caracas 64 6 4 Connector housing TC for support arm systems according to VESA 100 standard IP 65 65 6 5 Se UR 66 Appendix 7
57. l capacity 230 mAh Nominal voltage 3V Diameter 20 mm Height 3 2 mm Weight 3g Replacing the battery When the charge is too low or the battery is empty the data stored in the CMOS RAM e g date and time might not be accurate Then the Lithium battery must be replaced To replace the battery follow these steps Observe the precautions in section General requirements Open the housing as described in section Opening the device and closing it again e With a medium flat bladed screwdriver gently pry the battery enough to free the battery from its socket Install the new battery in the socket orienting the face up Close the TC again as described in section Opening the device and closing it again Notice Incorrect replacement leads to danger of explosion The battery may be replaced only with an identical battery or with a type recommended by the manufacturer Ensure that you insert the battery in the right way see polarity Note Do not throw Lithium batteries into the household waste They must be disposed of in accordance with local regulations concerning special waste Rev 1 01 dated 24 7 2008 Page 21 of 84 Commissioning and Operating Ol TC Web Flash memory The base board of the TC is firmly equipped with a Compact Flash card The Compact Flash card is used as a storage medium exclusively for system information Notice Do not save any data to the storage med
58. n may be operated in parallel Keyboard The TC is designed to connect a USB keyboard It can be connected to one of the USB ports Mouse The TC is designed to connect a USB mouse It can be connected to one of the USB ports Page 24 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Commissioning and Operating Plugging the keyboard and mouse Notice Plug in keyboard and or mouse only after the switch on of the device If keyboard and or mouse are already inserted on the USB interfaces during the switch on of the device they are not always functional After having inserted them again with the device switched on they are supplied correctly with supply voltage and are available for operation 1 Switch on the device 2 Plug in keyboard and or mouse Booting from USB stick Notice Put USB stick on USB 1 for booting If the TC has to boot from a USB stick the stick must be plugged on USB 1 e USB 1 is located on the rear side of the housing and is the left vertically installed USB interface With the connector housing mounted on the rear of the housing USB 1 is the upper one of the two if available USB interfaces USB 1 corresponds with port 0 on the CPU platform which the system searches for booting All other USB interfaces are not suitable for booting Example TC12 S stand alone with adapter plate for VESA 100 The following is valid correspondingly for other versions Rear side of the housing
59. n e e cete ed eae ceu pesi 23 Fig 3 3 Identification laDel iia ota dpto 24 Fig 3 4 Connections at the connector housing ococcccnninnnonicnonccnnocnnonannna cnn rana 24 Fig 3 5 USB stick for booting on USB 1 port 0 25 Fig 3 6 Frontview De RE 26 Fig 3 7 Membrane Key DO aI M deeg ein llibre 26 Fig 4 1 Display manager after DOING sindene nni akana einean gaa era aaa a entente nnne nene 30 Fig 4 2 Eege ee EE EM Fig 4 3 elei ERT 32 Fig 4 4 System ICONTIQUIATION TTT 33 Fig 4 5 Storing of modificato EE 33 Fig 4 6 Display Settlfigs EE 34 Fig 4 7 TOUCH Settings ET 35 Fig 4 8 Network Configurations EE 36 Fig 4 9 Passwords EE 37 Fig 4 10 Update Select image and start mode enne nennen 37 Fig E eknek ist ne ekee EN aa ERES EEN EESE R EENAA E AEE SERATA EAE EERENS E SE 38 Fig 4 12 Connection establishment AAA 39 Fig 4 13 Example for Web connection with Automatic login ssssseeeennens 41 Fig 4 14 Example for RDP connechon enne nennen nnns en tenens nnns nitent 42 Fig 4 15 Example for VNC connechon nn 43 Fig 4 16 Ultra VNG Sever 2 e eter te n a c a EP dcn a ERU th te io ANE ie 44 Fig 4 17 5 TIQMVNO SO iii ee etl a ita 45 Fig 5 1 UE R 51 Fig 5 2 SNE IT cBek weak eds 51 Fig 5 3 Microphone input and audio output eee arein eee etne ee eee te ee erent ee eee nese nana nc cnn SAREE REN REKKAA 51 Fi
60. n to induce you to infringe any patents or other property right claims or to contest validity of any such claims this section has the sole purpose of protecting the integrity of the free software distribution system which is implemented by public license practices Many people have made generous contributions to the wide range of software distributed through that system in reliance on consistent application of that system it is up to the author donor to decide if he or she is willing to distribute software through any other System and a licensee cannot impose that choice This section is intended to make thoroughly clear what is believed to be a consequence of the rest of this License Rev 1 01 dated 24 7 2008 Ol TC Web 12 13 14 Appendix Licensing If the distribution and or use of the Library is restricted in certain countries either by patents or by copyrighted interfaces the original copyright holder who places the Library under this License may add an explicit geographical distribution limitation excluding those countries so that distribution is permitted only in or among countries not thus excluded In such case this License incorporates the limitation as if written in the body of this License The Free Software Foundation may publish revised and or new versions of the Lesser General Public License from time to time Such new versions will be similar in spirit to the present version but may differ in detail to address
61. nclude the copyright notice for the Library among them as well as a reference directing the user to the copy of this License Also you must do one of these things a Accompany the work with the complete corresponding machine readable source code for the Library including whatever changes were used in the work which must be distributed under Sections 1 and 2 above and if the work is an executable linked with the Library with the complete machine readable work that uses the Library as object code and or source code so that the user can modify the Library and then relink to produce a modified executable containing the modified Library It is understood that the user who changes the contents of definitions files in the Library will not necessarily be able to recompile the application to use the modified definitions b Use a suitable shared library mechanism for linking with the Library A suitable mechanism is one that 1 uses at run time a copy of the library already present on the user s computer system rather than copying library functions into the executable and 2 will operate properly with a modified version of the library if the user installs one as long as the modified version is interface compatible with the version that the work was made with c Accompany the work with a written offer valid for at least three years to give the same user the materials specified in Subsection 6a above for a charge no more than the cost of
62. ndation Inc 51 Franklin Street Fifth Floor Boston MA 02110 1301 USA Everyone is permitted to copy and distribute verbatim copies of this license document but changing it is not allowed This is the first released version of the Lesser GPL It also counts as the successor of the GNU Library Public License version 2 hence the version number 2 1 Preamble The licenses for most software are designed to take away your freedom to share and change it By contrast the GNU General Public Licenses are intended to guarantee your freedom to share and change free software to make sure the software is free for all its users This license the Lesser General Public License applies to some specially designated software packages typically libraries of the Free Software Foundation and other authors who decide to use it You can use it too but we suggest you first think carefully about whether this license or the ordinary General Public License is the better strategy to use in any particular case based on the explanations below When we speak of free software we are referring to freedom of use not price Our General Public Licenses are designed to make sure that you have the freedom to distribute copies of free software and charge for this service if you wish that you receive source code or can get it if you want it that you can change the software and use pieces of it in new free programs and that you are informed that you can do t
63. nds that there is no warranty for this free software If the software is modified by someone else and passed on we want its recipients to know that what they have is not the original so that any problems introduced by others will not reflect on the original authors reputations Finally any free program is threatened constantly by software patents We wish to avoid the danger that redistributors of a free program will individually obtain patent licenses in effect making the program proprietary To prevent this we have made it clear that any patent must be licensed for everyone s free use or not licensed at all The precise terms and conditions for copying distribution and modification follow Rev 1 01 dated 24 7 2008 Page 69 of 84 Appendix Licensing Ol TC Web GNU GENERAL PUBLIC LICENSE TERMS AND CONDITIONS FOR COPYING DISTRIBUTION AND MODIFICATION 0 This License applies to any program or other work which contains a notice placed by the copyright holder saying it may be distributed under the terms of this General Public License The Program below refers to any such program or work and a work based on the Program means either the Program or any derivative work under copyright law that is to say a work containing the Program or a portion of it either verbatim or with modifications and or translated into another language Hereinafter translation is included without limitation in the term modification Each licensee is add
64. new problems or concerns Each version is given a distinguishing version number If the Library specifies a version number of this License which applies to it and any later version you have the option of following the terms and conditions either of that version or of any later version published by the Free Software Foundation If the Library does not specify a license version number you may choose any version ever published by the Free Software Foundation If you wish to incorporate parts of the Library into other free programs whose distribution conditions are incompatible with these write to the author to ask for permission For software which is copyrighted by the Free Software Foundation write to the Free Software Foundation we sometimes make exceptions for this Our decision will be guided by the two goals of preserving the free status of all derivatives of our free software and of promoting the sharing and reuse of software generally NO WARRANTY 15 16 BECAUSE THE LIBRARY IS LICENSED FREE OF CHARGE THERE IS NO WARRANTY FOR THE LIBRARY TO THE EXTENT PERMITTED BY APPLICABLE LAW EXCEPT WHEN OTHERWISE STATED IN WRITING THE COPYRIGHT HOLDERS AND OR OTHER PARTIES PROVIDE THE LIBRARY AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE LIBRARY IS WITH Y
65. notice is found Als lt one line to give the library s name and a brief idea of what it does gt Copyright C lt year gt lt name of author gt This library is free software you can redistribute it and or modify it under the terms of the GNU Lesser General Public License as published by the Free Software Foundation either version 2 1 of the License or at your option any later version This library is distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE See the GNU Lesser General Public License for more details You should have received a copy of the GNU Lesser General Public License along with this library if not write to the Free Software Foundation Inc 51 Franklin Street Fifth Floor Boston MA 02110 1301 USA o add information on how to contact you by electronic and paper mail You should also get your employer if you work as a programmer or your school if any to sign a CO pyright disclaimer for the library if necessary Here is a sample alter the names Yoyodyne Inc hereby disclaims all copyright interest in the library Frob a library for tweaking knobs written by James Random Hacker signature of Ty Coon 1 April 1990 Ty Coon President of Vice That s all there is to it Page 82 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Appendix Licensing 7 4 BSD Copyright Notation
66. performing this distribution d If distribution of the work is made by offering access to copy from a designated place offer equivalent access to copy the above specified materials from the same place e Verify that the user has already received a copy of these materials or that you have already sent this user a copy For an executable the required form of the work that uses the Library must include any data and utility programs needed for reproducing the executable from it However as a special exception the materials to be distributed need not include anything that is normally distributed in either source or binary form with the major components compiler kernel and so on of the operating system on which the executable runs unless that component itself accompanies the executable It may happen that this requirement contradicts the license restrictions of other proprietary libraries that do not normally accompany the operating system Such a contradiction means you cannot use both them and the Library together in an executable that you distribute Rev 1 01 dated 24 7 2008 Page 79 of 84 Appendix Licensing Ol TC Web 7 10 11 Page 80 of 84 You may place library facilities that are a work based on the Library side by side in a single library together with other library facilities not covered by this License and distribute such a combined library provided that the separate distribution of the work based on the Lib
67. pling Article no 6114796 42 43 100 115 lt lt 42 43 gt 100 115 Scale 1 1 General tolerances 1 ISO 2768 mK Material thickness 2 5 mm Fig 6 10 Adapter plate for ROSE GT 48 2 flange angle coupling Page 64 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Mechanical Dimensions 6 4 Connector housing TC for support arm systems according to VESA 100 standard IP 65 Example Connector housing TC with the connections 24 VDC and Ethernet 2 x USB Article no 6286139 Mi 100 115 m m 100 General tolerances ISO 2768 mK Fig 6 11 Connector housing TC for support arm systems according to VESA 100 standard IP 65 Note The mechanical dimensions of the different connector housings are identical Only the number of the USB connections on the right hand side is different Rev 1 01 dated 24 7 2008 Page 65 of 84 Mechanical Dimensions Ol TC Web 6 5 Pedestal TC Example Pedestal TC VESA Article no 6286141 A 330 mm 165 mm to 310 mm gt e ge Fig 6 12 Pedestal TC VESA Note The mechanical dimensions of the pedestal Connector housing is identical Only the adapter plate for the mounting at the TC is different Page 66 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Appendix Licensing Appendix Licensing Licensing regulations Free software packages The system software of th
68. ply Disconnect all connection cables from the TC Loosen the four screws at the adapter plate M5x8 Hexagon socket Remove the adapter plate to the back After having removed the adapter plate Compact Flash card and battery on the base board are accessible and can be exchanged if necessary Mounting the adapter plate While installing Pay attention to integrity and correct position of the sealing on the rear mounted part of housing Protection class IP 65 all around Guarantee contact between EMC spring clips and adapter plate e Put in the adapter plate so across the interface connections that the EMC spring clips at the USB sockets press against the adapter plate from below and guarantee the contact with that Set the four screws through the holes in the adapter plate into the threads in the rear mounted part and tighten them again Device with connector housing At the connector housing the four special bolts are to be loosened in order to remove the connector housing Take special care of the internal wiring Page 20 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Commissioning and Operating 3 4 3 Back up battery The battery that is installed on the base board provides Real Time Clock and CMOS memory with a current in order to permanently save system information even if the board is separated from the supply Type CR2032 Electrochemical system Primary Lithium cylindrical and button Nomina
69. port damages e Remove the packaging carefully in order to avoid damages Save the original packaging for a possible new transportation of the TC Keep also the supplied documents Checking Check the contents of the packaging for visible transport damages Check the contents for completeness by means of the delivery note Storing and transporting The TC is constructed solidly indeed The included components are however sensitive to excessive shocks and impacts Therefore protect the TC against too great mechanical stress The device must be transported in its original packaging completely with all shock absorbing parts Ensure that no condensation is formed on the device when it is stored transported during cold weather periods or when it is exposed to extreme deviations of temperature Installing The TC is approved for operation in closed rooms Please adhere also to the chapter Technical Data during installing the TC Rev 1 01 dated 24 7 2008 Page 11 of 84 Installation Ol TC Web 2 3 1 2 3 2 You ve got to observe the following items in order to effect a trouble free operation of the TC and to avoid damages Temperature Prior to commissioning Allow the device time to adjust to room temperature f condensation has formed do not turn the device on until it is absolutely dry Prevent overheating during operation Protect the device from direct radiation by sunlight or other heat sources
70. r the terms of this License d If a facility in the modified Library refers to a function or a table of data to be supplied by an application program that uses the facility other than as an argument passed when the facility is invoked then you must make a good faith effort to ensure that in the event an application does not supply such function or table the facility still operates and performs whatever part of its purpose remains meaningful For example a function in a library to compute square roots has a purpose that is entirely well defined independent of the application Therefore Subsection 2d requires that any application supplied function or table used by this function must be optional if the application does not supply it the square root function must still compute square roots Rev 1 01 dated 24 7 2008 Page 77 of 84 Appendix Licensing Ol TC Web Co al Page 78 of 84 These requirements apply to the modified work as a whole If identifiable sections of that work are not derived from the Library and can be reasonably considered independent and separate works in themselves then this License and its terms do not apply to those sections when you distribute them as separate works But when you distribute the same sections as part of a whole which is a work based on the Library the distribution of the whole must be on the terms of this License whose permissions for other licensees extend to the entire whole and thus
71. rary and of the other library facilities is otherwise permitted and provided that you do these two things a Accompany the combined library with a copy of the same work based on the Library uncombined with any other library facilities This must be distributed under the terms of the Sections above b Give prominent notice with the combined library of the fact that part of it is a work based on the Library and explaining where to find the accompanying uncombined form of the same work You may not copy modify sublicense link with or distribute the Library except as expressly provided under this License Any attempt otherwise to copy modify sublicense link with or distribute the Library is void and will automatically terminate your rights under this License However parties who have received copies or rights from you under this License will not have their licenses terminated so long as such parties remain in full compliance You are not required to accept this License since you have not signed it However nothing else grants you permission to modify or distribute the Library or its derivative works These actions are prohibited by law if you do not accept this License Therefore by modifying or distributing the Library or any work based on the Library you indicate your acceptance of this License to do so and all its terms and conditions for copying distributing or modifying the Library or works based on it Each time
72. rating system and Software Ol TC Web 4 2 3 Tools Configuring the device parameters Operating the user software Backlight Settings Audio Settings System information Backlight Bu zu EA Fig 4 3 Tools menu 4 2 4 Stand by amp Turning on off the signal Up to the present this function is not implemented Page 32 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Operating system and Software 4 3 System configuration The system configuration contains all configuration screens necessary for the adaptation of the client system to the system infrastructure Display e Touch e Network e Passwords Update Connections Display Touch Network Passwords Update Fig 4 4 System configuration Value modifications of the individual part dialogues can be transferred with button Submit or discarded with button Cancel Cancel Submit All pending modifications must be saved via Exit in the menu item Connection ES Configuration v Save modifications Exit Fig 4 5 Storing of modifications The checkbox Save modifications is visible only if modifications have been conducted If Exit is put into action a script will be started which updates the system configuration and reboots the TC Rev 1 01 dated 24 7 2008 Page 33 of 84 Operating system and Software Ol TC Web 4 3 1 Display Following functions can be set in the menu
73. ressed as you Activities other than copying distribution and modification are not covered by this License they are outside its scope The act of running the Program is not restricted and the output from the Program is covered only if its contents constitute a work based on the Program independent of having been made by running the Program Whether that is true depends on what the Program does 1 You may copy and distribute verbatim copies of the Program s source code as you receive it in any medium provided that you conspicuously and appropriately publish on each copy an appropriate copyright notice and disclaimer of warranty keep intact all the notices that refer to this License and to the absence of any warranty and give any other recipients of the Program a copy of this License along with the Program You may charge a fee for the physical act of transferring a copy and you may at your option offer warranty protection in exchange for a fee 2 You may modify your copy or copies of the Program or any portion of it thus forming a work based on the Program and copy and distribute such modifications or work under the terms of Section 1 above provided that you also meet all of these conditions a You must cause the modified files to carry prominent notices stating that you changed the files and the date of any change b You must cause any work that you distribute or publish that in whole or in part contains or is derived from the Pro
74. rm under the terms of Sections 1 and 2 above provided that you accompany it with the complete corresponding machine readable source code which must be distributed under the terms of Sections 1 and 2 above on a medium customarily used for software interchange If distribution of object code is made by offering access to copy from a designated place then offering equivalent access to copy the source code from the same place satisfies the requirement to distribute the source code even though third parties are not compelled to copy the source along with the object code A program that contains no derivative of any portion of the Library but is designed to work with the Library by being compiled or linked with it is called a work that uses the Library Such a work in isolation is not a derivative work of the Library and therefore falls outside the scope of this License However linking a work that uses the Library with the Library creates an executable that is a derivative of the Library because it contains portions of the Library rather than a work that uses the library The executable is therefore covered by this License Section 6 states terms for distribution of such executables When a work that uses the Library uses material from a header file that is part of the Library the object code for the work may be a derivative work of the Library even though the source code is not Whether this is true is especially significant if t
75. t covered by this License they are outside its scope The act of running a program using the Library is not restricted and output from such a program is covered only if its contents constitute a work based on the Library independent of the use of the Library in a tool for writing it Whether that is true depends on what the Library does and what the program that uses the Library does 1 You may copy and distribute verbatim copies of the Library s complete source code as you receive it in any medium provided that you conspicuously and appropriately publish on each copy an appropriate copyright notice and disclaimer of warranty keep intact all the notices that refer to this License and to the absence of any warranty and distribute a copy of this License along with the Library You may charge a fee for the physical act of transferring a copy and you may at your option offer warranty protection in exchange for a fee 2 You may modify your copy or copies of the Library or any portion of it thus forming a work based on the Library and copy and distribute such modifications or work under the terms of Section 1 above provided that you also meet all of these conditions a The modified work must itself be a software library b You must cause the files modified to carry prominent notices stating that you changed the files and the date of any change C You must cause the whole of the work to be licensed at no charge to all third parties unde
76. t of the Free Software Foundation s software and to any other program whose authors commit to using it Some other Free Software Foundation software is covered by the GNU Lesser General Public License instead You can apply it to your programs too When we speak of free software we are referring to freedom not price Our General Public Licenses are designed to make sure that you have the freedom to distribute copies of free software and charge for this service if you wish that you receive source code or can get it if you want it that you can change the software or use pieces of it in new free programs and that you know you can do these things To protect your rights we need to make restrictions that forbid anyone to deny you these rights or to ask you to surrender the rights These restrictions translate to certain responsibilities for you if you distribute copies of the software or if you modify it For example if you distribute copies of such a program whether gratis or for a fee you must give the recipients all the rights that you have You must make sure that they too receive or can get the source code And you must show them these terms so they know their rights We protect your rights with two steps 1 copyright the software and 2 offer you this license which gives you legal permission to copy distribute and or modify the software Also for each author s protection and ours we want to make certain that everyone understa
77. ta in the section Interfaces at the connector housing Using peripheral devices The devices of MSC Tuttlingen GmbH offer by means of their peripheral interfaces the possibility to connect different components When using standard peripheral devices e g at the USB port you have to note that their electromagnetic interference immunity is often only sufficient for office environments They are not suitable however for operating in the industrial environment Rev 1 01 dated 24 7 2008 Page 17 of 84 Installation Ol TC Web This page is left intentionally blank Page 18 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Commissioning and Operating 3 3 1 Commissioning and Operating Expanding the TC Note TC is acompletely configured device An hardware expansion is not possible If necessary only the replacement of Compact Flash card and back up battery is required General requirements Limitation of liability All technical specifications and approvals apply only to expansions approved by MSC Tuttlingen GmbH No liability can be accepted for impairment of functions caused by the use of devices and components from other manufacturers All modules and components are electrostatically sensitive t A The ESD notes are absolutely to be considered The opposite symbol indicates the use of electrostatically sensitive modules Precautions Electronic components are extremely sensitive to electrostatic discharg
78. th the requirements of the EMC directive 2004 108 EC on basis of the standards following in chapter Technical Data The EC declarations of conformity and the related documentation will be maintained at the following address for inspection by the responsible officials in accordance with article 10 1 of the above stated EC directive MSC Tuttlingen GmbH Rudolf Diesel StraBe 17 78532 Tuttlingen Germany Areas of use Products of MSC Tuttlingen GmbH meet the applicable harmonized European standards for the respective area of applications Warranty For the devices of MSC Tuttlingen GmbH the agreements determined in the General Terms and Conditions AGB are valid Fitting conditions The fitting conditions and safety notes in the submitted document must be adhered to when commissioning and operating the products Trade names and or trademarks All hardware and software names are trade names and or trademarks of the respective manufacturer Copyright Every user documentation is intended for the operator and the operator s personnel only The transmission and reproduction of this document and the exploitation and communication of its contents are not allowed without express authority Offenders will be liable for damages Il Rev 1 01 dated 24 7 2008 Ol TC Web Contents Contents 1 Characteristics EE 5 1 1 ee sce ee ee aly cai nun A E eee 5 1 2 EE 6 1 3 Kieler VIC 6 1 4 EE H 2 UI nl Vu EE 11 2 1 Unpacking and ch
79. v 1 01 dated 24 7 2008 Ol TC Web Technical Data Component Description Article no Accessories Adapter plate TC for VESA 100 6114674 Adapter plate TC for Bernstein CS 2000 SL housing coupling 6114795 Adapter plate TC for Rittal CP S support arm system and ROSE GT48 2 flange angle coupling 6114796 Connector housing TC for support arm systems according to VESA 100 standard IP 65 24 VDC and Ethernet without USB 6286137 Connector housing TC for support arm systems according to VESA 100 standard IP 65 24 VDC and Ethernet 1 x USB 6286138 Connector housing TC for support arm systems according to VESA 100 standard IP 65 24 VDC and Ethernet 2 x USB 6286139 Pedestal TC VESA 6286141 Pedestal TC connector housing 6286140 Table power supply unit 6251119 Rev 1 01 dated 24 7 2008 Page 49 of 84 Technical Data Ol TC Web 5 2 Device specific Specific dates for different versions of the TC Web line are described in this section mn o 3 Version Indication Article no Order code CPU Display OS Weight 315x280 front panel membrane keyboard MSC 12 1 touch 315x280 front panel membrane keyboard neutral 12 1 touch 410x370 front panel membrane keyboard MSC 17 0 touch 410x370 front panel membrane keyboard neutral 17 0 touch SE 3 gt x RE S s Jalal 5 2 ojo o bs 3 EE B o Ex la 8 25 as ui 8 Stand
80. vides advantages in certain special circumstances For example on rare occasions there may be a special need to encourage the widest possible use of a certain library so that it becomes a de facto standard To achieve this non free programs must be allowed to use the library A more frequent case is that a free library does the same job as widely used non free libraries In this case there is little to gain by limiting the free library to free software only so we use the Lesser General Public License In other cases permission to use a particular library in non free programs enables a greater number of people to use a large body of free software For example permission to use the GNU C Library in non free programs enables many more people to use the whole GNU operating system as well as its variant the GNU Linux operating system Although the Lesser General Public License is Less protective of the users freedom it does ensure that the user of a program that is linked with the Library has the freedom and the wherewithal to run that program using a modified version of the Library The precise terms and conditions for copying distribution and modification follow Pay close attention to the difference between a work based on the library and a work that uses the library The former contains code derived from the library whereas the latter must be combined with the library in order to run Page 76 of 84 Rev 1 01 dated 24 7 2008 Ol
81. y dete itive He ut diede 26 3 3 1 Membrane keyboard sciensia i naria cnn 26 Function EE 26 Status DRETT 26 3 3 2 Touchscreen cup d et d d ae eld ean deeded 27 3 3 3 Glean Ng zeigen 27 4 Operating system and Software uuunsssssnnannnnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnannnnn nenn 29 4 1 Characteristics Arne ee EE 29 4 1 1 Switchison Deliavior del ie eet oae dus a is 29 4 1 2 BOGIN Neie 30 4 1 3 Remote COnfiguration sessi essen enne nn nnn senten ensis nnns sn r sinn sinis snnt nnns 30 4 2 Operating elements iet tiae da Base eR Rage a neun 31 4 2 1 SOlt KGVDOaId to amaa e E 31 4 2 2 TOUCH Bee ee 31 4 2 3 Rei 32 4 2 4 Elie DEE 32 4 3 System COMPQUIATION RR 33 4 3 1 Displays ds ntu ee eee ee 34 4 3 2 ao a a E eer rere AT A E a a a LO e ecce 35 4 3 3 ING TW EE 36 4 3 4 See EE 37 4 3 5 Update E 37 4 3 6 Language setllrig a ona bae Ode td aseo ads 38 Rev 1 01 dated 24 7 2008 Page 1 of 84 Contents Ol TC Web 4 4 Connection esiabliehment eene nn cnn rra nnne sre nnns nnns 39 4 4 1 Manual connection establishment eene sn nennen nns 39 4 4 2 Automatic connection establishment AAA 40 4 5 Connection configuration u 240rsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnsnnnnnnannennnnnnnn 41 4 5 1 Web Ree ul ee TEE 41 4 5 2 RDesktop connection Windows Terminal Gervices senses seaeeesaeeeeneees 42 4 5 3 AN Teile EEN 43 4 5 4 Configuring the VNC server 44 5 Technica
82. you redistribute the Library or any work based on the Library the recipient automatically receives a license from the original licensor to copy distribute link with or modify the Library subject to these terms and conditions You may not impose any further restrictions on the recipients exercise of the rights granted herein You are not responsible for enforcing compliance by third parties with this License If as a consequence of a court judgment or allegation of patent infringement or for any other reason not limited to patent issues conditions are imposed on you whether by court order agreement or otherwise that contradict the conditions of this License they do not excuse you from the conditions of this License If you cannot distribute so as to satisfy simultaneously your obligations under this License and any other pertinent obligations then as a consequence you may not distribute the Library at all For example if a patent license would not permit royalty free redistribution of the Library by all those who receive copies directly or indirectly through you then the only way you could satisfy both it and this License would be to refrain entirely from distribution of the Library If any portion of this section is held invalid or unenforceable under any particular circumstance the balance of the section is intended to apply and the section as a whole is intended to apply in other circumstances It is not the purpose of this sectio
83. ystem Bernstein CS 2000 SL housing coupling ROSE GT48 2 flange angle coupling Page 60 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Mechanical Dimensions 6 3 Adapter plates TC for standard flange systems For specific standard flange systems there are appropriate adapter plates in the scope of supply for TC12 S and TC17 S 6 3 1 Support arm system according to VESA 100 standard Article no 6114674 100 115 100 115 Scale 1 1 General tolerances ISO 2768 mK Material thickness 2 5 mm Fig 6 7 Adapter plate TC for support arm system according to VESA 100 standard Rev 1 01 dated 24 7 2008 Page 61 of 84 Mechanical Dimensions Ol TC Web 6 3 2 Rittal CP S support arm system Article no 6114796 45 96 100 115 45 96 100 115 Scale 1 1 General tolerances p 3 ISO 2768 mK Material thickness 2 5 mm Fig 6 8 Adapter plate for Rittal CP S support arm system Page 62 of 84 Rev 1 01 dated 24 7 2008 Ol TC Web Mechanical Dimensions 6 3 3 Bernstein CS 2000 SL housing coupling Article no 6114795 60 100 115 100 115 Scale 1 1 General tolerances ISO 2768 mK Material thickness 2 5 mm Fig 6 9 Adapter plate for Bernstein CS 2000 SL housing coupling Rev 1 01 dated 24 7 2008 Page 63 of 84 Mechanical Dimensions Ol TC Web 6 3 4 ROSE GT48 2 flange angle cou