Home

PULSAR 10 User manual

image

Contents

1. 2 8 2 2 4 Windows for Workgroups 3 11 2 8 2 2 5 Windows NT 3 51 2 10 2 2 6 Windows NT 4 0 2 10 2 2 7 Windows 95 Installation 2 11 2 2 8 Windows 98 installation 2 11 2 2 9 Windows 2000 installation 2 11 2 2 10 Artisoft Lantastic 6 0 Installation 2 12 2 2 11 IBM OS 2 Warp 2 12 3 GENERAL INFORMATION NOTES HINTS TIPS 3 1 3 1 NOTES FOR NDIS DRIVER 3 1 3 2 NOTES FOR PACKET DRIVER 3 1 3 3 NOTES FOR WINDOWS FOR WORKGROUPS DRIVER 3 2 4 QUESTIONS AND ANSWERS 4 1 5 APPENDIX A PRODUCT SPECIFICATIONS 5 5 5 1 OPERATING ENVIRONMENT 5 5 5 2 PHYSICAL cesccccccececscceseccscecseccnececeaccsasaeanas 5 5 09 09 99 Bausch Datacom Pulsar 10 GENERAL INFORMATION 1 INTRODUCTION 1 1 ABOUT THIS MANUAL This manual will explain how to install and use your Pulsar 10 Ethernet card 12 ABOUT THIS PRODUCT The PULSAR 10 Ethernet card is a credit card size Type PCMCIA Ethernet adapter that complies with the PCMCIA 2 1 and IEEE 802 3 standards and works with computers that incorporate a compatible interface The drivers associated with this card allow you to easily use the most popular Network Operating System NOS in the PC environment 1 3 SYSTEM REQU
2. Set NetWare 4 X to English LSL Link Support Layer Module provided by Novell LE10ODI Hardware Specific Module IPXODI PX Protocol Stack Module provided by Novell VLM DOS Support Module provided by Novell F Change to connected device LOGIN xxx Login to file server as user xxx 17 Run STARTNET to access the Novell network 09 09 99 2 6 Bausch Datacom Pulsar 10 GENERAL INFORMATION 2 2 2 MS LAN Manager 1 View the README TXT on the installation diskette in the NDIS2 directory Before installing the drivers please ensure the Microsoft LAN Manager has been installed in the target path The installation program will check and modify the PROTOCOL INI file for LAN Manager 2 Run INSTALL EXE from the root directory of the driver diskette 3 Select the Microsoft LAN Manager item on the menu screen 4 lf the current settings are acceptable select Start Installation and go to step 6 Otherwise select Modify Parameters to change the settings 5 Move the cursor to each field you want to change and press lt Enter gt to select a fit value When the configuration is finished press lt Enter gt on the OK field to exit the screen and go back to step 4 6 The installation program starts copying related files from the driver diskette to the destination directory and modifies the CONFIG SYS and PROTOCOL INI 7 Reboot the computer to load the driver and start LAN Manager in batch PCMCIA Ethernet Card LAN IRQ Level LAN 140 B
3. memory management software e g EMM386 has been installed you have to reserve an area in the upper memory C000 0 EFFF F for the attribute memory of the PULSAR 10 card when enabling the card Example Device C DOS EMM386 EXE RAM X D000 D3FF Reserve D000 D3FF for attribute memory Q How will know the PULSAR 10 Ethernet card has been enabled or not A If the Card Service is installed you will hear beep when you insert the card 2 Run LANEN CHK to check if the card has been enabled The resources allocated for the card are shown below at the last line of the display message Ozxxx Slot nn Q How to enable the PULSAR 10 Ethernet card A 1 The PULSAR 10 Ethernet card can be enabled by the Card Service installed on the laptop The drivers associated with the card on the driver diskette can be used together with Card Service 2 In case the Card Service cannot enable the PULSAR 10 card you may run LANEN to enable it After the LANEN has been run either the driver on the driver diskette or the standard NE2000 driver can be used as the LAN driver Q How to make the Pulsar 10 work under Systemsoft Card Service A There are several procedures to enable the card by Cardsoft 1 Copy the LE10 CLB file Copy FROM A PCMCIA CARDSOFT LE10 CLB TO CACARDSOFT LE10 CLB Depends on where the Cardsoft is saved 2 Edit the CARDID INI file and add the library LE10 CLB Edit C CARDSOFT CARDID INI Find the section which star
4. 8 Select the source drive and directory For Example D OS2IMAGE 9 Click Install 10 Click OK B Install the NDIS2 driver for IBM LAN Server 4 0 1 In the OS 2 Desktop group double click on the MPTS icon 2 Click Configure 3 Select the LAN adapters and protocols option 4 Click Configure 09 09 99 2 12 Bausch Datacom Pulsar 10 GENERAL INFORMATION 5 Select the Other adapters option 6 Insert the driver diskette and type the driver path A OS2 NDIS2 Click OK 7 Select PULSAR 10 Ethernet Adapter then click Add 8 Select IBM OS 2 NETBIOS then click Add 9 Click OK 10 Click Close 11 Click Exit 12 Shutdown and restart your system ODI Driver for IBM OS 2 Warp Before installing the driver please ensure the PCMCIA Service is installed and works properly If the PCMCIA Service of OS 2 Warp has already been enabled jump to portion B for the driver installation Otherwise follow the instructions below to install the PCMCIA Service A Enable PCMCIA Service of OS 2 Warp 1 In the OS 2 Desktop group double click on the OS 2 System icon 2 Double click on the System Setup icon 3 Double click on the Selective Install icon 4 Select the PCMCIA Support button 5 Select PCMCIA system For example select IBM ThinkPad 750 6 Click OK 7 Click Install 8 Select the source drive and directory For Example D OS2IMAGE 9 Click Install 10 Click OK B Install Netware Request 1 Insert the diskette labeled WSOS2_1 in the diskett
5. INFORMATION 2 2 10 Artisoft Lantastic 6 0 Installation 1 First install LANTASTIC 6 0 2 Run INSTALL EXE from the root directory of the driver diskette 3 Select LANTASTIC 6 0 in the Network Operating System screen 4 lf the current settings are acceptable select Start Installation and go to step 6 Otherwise select Modify Parameters to change the settings 5 Move the cursor to the field you want to change and press lt Enter gt to select a fit value When the configuration is finished press lt Enter gt on the OK field to exit the screen and go back to step 4 6 The installation program starts copying the related files from the diskette to the destination directory and modifies the CONFIG SYS PROTOCOL INI and STARTNET BAT 7 Please reboot the computer to load the driver 2 2 11 IBM OS 2 Warp NDIS2 Driver for OS2 Warp Before installing the driver please ensure the PCMCIA Service was properly installed and works correctly If the PCMCIA Service of OS 2 Warp has already been enabled please move on to portion B for the driver installation Otherwise follow the instructions below to install the PCMCIA Service A Enable PCMCIA Service of OS 2 Warp 1 In the OS 2 Desktop group double click on the OS 2 System icon 2 Double click on the System Setup icon 3 Double click on the Selective Install icon 4 Select the PCMCIA Support button 5 Select PCMCIA system For example select IBM ThinkPad 750 6 Click OK 7 Click Install
6. In the Networks dialog box check the radio button before you can go to Install Microsoft Windows Network and No Additional Network Press OK to go back to the Network Settings screen 4 Click Drivers to select the network driver 5 In the Network Drivers dialog box press Add Adapter to enter the Add Network Adapter dialog box Select Unlisted or Updated Network Adapter and press OK 6 Windows will prompt an Install Driver dialog box Put the driver diskette into the floppy drive and press OK 7 Select the Enhanced mode NDIS3 for string and press OK 8 Follow the Windows instructions to complete the installation and exit Windows 9 Run INSTALL EXE from the root directory of the driver diskette 10 Select Windows for Workgroup in the Network Operating System screen 11 If the current settings are acceptable select Start Installation and go to step 13 Otherwise select Modify Parameters to change the settings 12 Move the cursor to the setting you want to change and press Enter to select a fit value When the configuration is accepted press Enter on the OK field to exit the screen and go back to step 11 13 Select NDIS Server LAN Manager as the network server you will attach to and press Enter key 14 The installation program starts copying related files to the destination directory and modifies the AUTOEXEC BAT 15 Reboot the computer to load the driver 09 09 99 2 8 Bausch Datacom Pulsar 10 GENERAL INFORM
7. in your computer Q How to make the card work under Phoenix Card Service A You have to add a card to PCM If the card has been added you may use PCM to modify the resources requested for the card 1 Insert the Ethernet card into the PCMCIA slot 09 09 99 4 2 Bausch Datacom Pulsar 10 QUESTIONS AND ANSWERS 2 Execute PCM EXE supported by Phoenix PCM 3 Select the right socket with the PageUp PageDown key 4 Choose Configure item using ALT C 5 Choose Add Card to List item and Enter for first time or choose Edit Config Parameters for further edition 6 Set the IO range and IRQ for the card 7 Hit Enter then save the configuration 8 Exit PCM EXE using Alt V and select Exit 9 Reboot Q How to make the card work under Award Card Service A You need to run the PC Card Control for Windows program under Windows If you do not have Windows edit the CARDWARE INI file as indicated below Before running PC Card Control for Windows make sure the Ethernet Adapter card is inserted into one of your PC s sockets 1 Run PC Card Control for Windows from the Cardware sub directory 2 Press OK on any card detect errors you may get until you get to the main menu 3 Select the Cards option and choose Edit 4 Select right Socket and press Enter If you already have a device in the Defined box called LE10 go to step 11 5 Select New Device under the Defined devices box 6 Edit the new device to be named LE10 7 Sele
8. 13 Move the cursor to the setting you want to change and press lt Enter gt to select a fit value When the configuration is finished press lt Enter gt on the OK field to exit the screen and go back to step 11 14 Select Novell Netware Server as the network server you will attach to and press Enter 15 The installation program starts copying the related files to the destination directory and modifies the AUTOEXEC BAT and NET CFG 16 Reboot the computer to load the driver 2 2 5 Windows NT 3 51 1 In Main Group of NT 3 51 open Control Panel and click on the Network icon 2 In the Network Settings dialog box click Add Adapter The Add Network Adapter dialog box will appear 3 Choose Other Choos Requires Disk From Manufacturer from the network adapter card list and press Continue 4 When Windows NT prompts for the manufacturer disk insert the driver diskette and press OK until the Network Setting Change dialog box appears 5 Reboot 2 2 6 Windows NT 4 0 In order to proceed with the following steps the Network Services must already be installed in the NT 4 0 system 1 Insert the Ethernet Adapter into one of the system s PCMCIA Slots 2 Start Windows NT 4 0 3 Click My Computer 4 Click Control Panel 5 Run Network 6 Select Adapters page 7 Click Add to add a network adapter 8 Click Have Disk 9 Insert the driver disk into drive A 09 09 99 2 10 Bausch Datacom Pulsar 10 GENERAL INFORMATION 10 Specify th
9. ANEN Otherwise you cannot find any servers If you use the drivers supported by the Pulsar 10 the IRQ always matches no matter what IRQ value is set in NET CFG 09 09 99 4 4 Bausch Datacom Pulsar 10 QUESTIONS AND ANSWERS 5 APPENDIX A PRODUCT SPECIFICATIONS IEEE 802 3 10BaseT 10Base2 10Mbps speed Internal buffer memory No system memory used NE2000 compatible ODI client Packet driver and NDIS version 2 x 3 x driver supported 5 1 Operating Environment Novell Netware 3 x 4 x Microsoft LAN Manager Packet Driver Applications Microsoft Windows for Workgroups 3 11 Windows 3 1 Microsoft Windows NT 3 51 NT 4 0 Windows 95 Windows 98 Windows 2000 Lantastic 6 0 IBM OS 2 Warp Version 3 5 2 Physical PCMCIA Type Il 3 37 in x 2 128 in x 0 197 in 85 6mm x 54mm x 5mm Weight 35 g Power 5V 5 150mA PCMCIA Type Il 09 09 99 5 5 Bausch Datacom Pulsar 10 QUESTIONS AND ANSWERS A media coupler with RJ 45 socket for 10BaseT LAN only or a media coupler with both RJ 45 and BNC connector for either 10BaseT or 10Base2 LAN 09 09 99 5 6 Bausch Datacom
10. ATION NDIS2 Driver for Workgroups 1 Run Windows for Workgroups and click the Network Setup icon in Network group 2 In the Network Settings dialog box click Networks to select the network operating system 3 In the Networks dialog box check the radio button before you can go to Install Microsoft Windows Network and No Additional Network Press OK to go back to the Network Settings screen 4 Click Drivers to select the network driver 5 In the Network Drivers dialog box press Add Adapter to enter the Add Network Adapter dialog box Select Unlisted or Updated Network Adapter and press OK 6 Windows will prompt an Install Driver dialog box Put the driver diskette into the floppy drive and press OK 7 Select the Real mode NDIS2 for string and press OK 8 Follow the Windows instructions to complete the installation and exit Windows 9 Run INSTALL EXE from the root directory of the driver diskette 10 Select Windows for Workgroups in the Network Operating System screen 11 If the current settings are acceptable select Start Installation and go to step 13 Otherwise select Modify Parameters to change the settings 12 Move the cursor to the setting you want to change and press lt Enter gt to select a fit value When the configuration is finished press lt Enter gt on the OK field to exit the screen and go back to step 11 13 Select NDIS Server LAN Manager as the network server you will attach to and press lt Enter gt 14 Th
11. IREMENTS An IBM compatible PC with 386SX or faster processor At least one type II PCMCIA socket Drivers and utilities provided with this product PCMCIA release 2 1 compliant Card Services and Socket Services 10BaseT or 10Base2 Ethernet connectivity to your LAN 1 4 OPERATING ENVIRONMENTS Novell Netware 3 x 4 x Microsoft LAN Manager Packet Driver Applications Microsoft Windows for Workgroups 3 11 Microsoft Windows 3 1 Microsoft Windows NT 3 51 NT 4 0 Windows 95 Windows 98 Lantastic 6 0 IBM OS 2 Warp Version 3 Windows 2000 1 5 CONTENTS INCLUDED IN THE PACKAGE e PULSAR 10 Ethernet Card e 10BaseT or 10Base2 media coupler 09 09 99 1 1 Bausch Datacom Pulsar 10 A 12 driver disk User Manual on disk Quick installation guide A plastic case for the PULSAR 10 card 09 09 99 1 2 GENERAL INFORMATION Bausch Datacom Pulsar 10 GENERAL INFORMATION 2 INSTALLATION 2 1 INSTALLING THE PULSAR 10 CARD 1 Insert the PULSAR 10 Ethernet card into the PCMCIA slot with the 68 pin connector facing the PCMCIA slot and the label facing up 2 Plug the media coupler into the Pulsar 10 s 15 pin connector The hardware installation is now completed The PULSAR 10 Card will be powered directly from the PC 3 Connect the media coupler to the network using the RJ 45 UTP or T connector Coaxial cable 2 2 INSTALLING THE SOFTWARE Insert the driver diskette in the floppy drive and specify the current drive as the fl
12. NFIG SYS 31 Shutdown and restart your system 09 09 99 2 14 Bausch Datacom 3 GENERAL INFORMATION 3 1 NOTES FOR NDIS DRIVER The following are examples of a partial CONFIG SYS and AUTOEXEC BAT file for loading SystemSoft Card Services and NDIS2 driver Examples of a partial CONFIG SYS file DEVICE C CARDSOFT SS365SL EXE DEVICE C CARDSOFT CS EXE DEVICE C CARDSOFT CSALLOC EXE C CARDSOFT CSALLOC INI DEVICE C CARDSOFT CARDID EXE device c lanman dos drivers ethernet le1 O lanen exe device c lanman dos drivers protman dos I c lanman dos device c lanman dos drivers ethernet le1 O le1 Onds dos Examples of a partial AUTOEXEC BAT file SET PATH C LANMAN DOS NETPROG PATH NET START WORKSTATION LOAD NETBEUI The Ethernet configuration information for the DOS NDIS driver is contained in the PROTOCOL INI file The section of the PROTOCOL INI file that contains the configuration information for this card must begin with ILETONDS2 NIF The valid entries in the file are listed below LE10NDS2 NIF DRIVERNAME LE10NDS this line must always be present IOADDRESS value where value is one of 32 bytes boundary from 0x200 to 0x3e0 The leading Ox for the hex notation is required Use a value of 0 to have Card Services select theaddress base from its pool of available addresses INTERRUPT value where value is one of the following interrupts 3 4 5 7 9 10 11 12 15 To have Card Services select an available in
13. Pulsar 10 TABLE OF CONTENTS PULSAR 10 10BaseT amp 10Base2 Network type Pc card User manual http www bausch be info bausch be 09 09 99 Bausch Datacom Pulsar 10 TABLE OF CONTENTS User Manual Pulsar 10 network type Il Pc card This manual is under protection of the law of intellectual property Therefore it is illegal to copy translate or reproduce this manual even partially The manufacturer reserves the right to change or adapt the products without preliminary notice All brands mentioned in this manual are trademarks Pulsar 10 User manual BAUSCH DATACOM NV SA Tiensesteenweg 56 B 3360 Korbeek Lo Belgium Tel 32 0 16 46 12 88 Fax 32 0 16 46 31 51 09 09 99 09 09 99 Bausch Datacom Pulsar 10 TABLE OF CONTENTS TABLE OF CONTENTS 1 INTRODUCTION 1 1 1 1 ABOUT THIS 1 1 1 2 ABOUT THIS PRODUCT 1 1 1 3 SYSTEM REQUIREMENTS 1 1 1 4 OPERATING ENVIRONMENTS 1 1 1 5 CONTENTS INCLUDED IN THE PACKAGE 1 1 2 INSTALLATION 2 3 2 1 INSTALLING THE PULSAR 10 2 3 2 2 INSTALLING THE SOFTWARE 2 3 2 2 1 Novell Netware 2 3 2 2 2 MS LAN 2 7 2 2 3 Packet
14. ase Network 05 LAN Manager lt NDIS 2 8 Frame Type Target Path Driver Install Modify Parameters Select Previous Screen Example of PROTOCOL INI used by LAN Manager PROTMAN DRIVERNAME PROTMAN DYNAMIC YES PRIORITY NETBEUI NETBEUI_XIF Drivername netbeui SESSIONS 6 NCBS 12 BINDINGS LE10NDS LANABASE 0 LE10NDS_NIF protocol ini session for LAN driver IOADDRESS 0x320 INTERRUPT 11 09 09 99 2 7 Bausch Datacom Pulsar 10 GENERAL INFORMATION DRIVERNAME LE10NDS 2 2 3 Packet Driver 1 Run INSTALL EXE from the root directory of the driver diskette 2 Select the Packet Driver item on the menu screen 3 If the current settings are acceptable select Start Installation and go to step 5 Otherwise select Modify Parameters to change the settings 4 Move the cursor to focus on the field you want to change and press lt Enter gt to select a fit value When the configuration is finished press lt Enter gt on the OK field to exit the screen and go back to step 3 5 The installation program starts copying related files from the diskette to the destination directory and modifies the AUTOEXEC BAT 6 Reboot the computer to load the driver 2 2 4 Windows for Workgroups 3 11 NDIS3 Driver for Workgroups 1 Run Windows for Workgroups and click the Network Setup icon in Network group 2 In the Network Settings dialog box click the Networks to select the network operating system 3
15. ct IO range 1 Base Hex 320 Length 32 16 bit 8 Do not alter MEM range 1 or 2 9 Select IRQ level 11 Click OK to change 10 Back on the Edit card screen highlight the LE10 device in the defined devices box 11 Transfer the LE10 to the Associated box with the Include command 12 Select OK to complete editing and return to the main screen 13 f the LE10 card is not graphically depicted choose Card and Reconfigure the socket which contains the LE10 card If you still have problems with the CARDWARE software try to replace your CARDWARE INI file with the one supplied on the Ethernet Adapter Drivers Disk In DOS mode you may use the PCCARD D or DOSCARD D command to check the resources allocated for the card Q The ODI driver is run successfully but fails to login to the Netware server C Frame type is incompatible with server or Interrupt miss match 09 09 99 4 3 Bausch Datacom Pulsar 10 QUESTIONS AND ANSWERS A 1 The default frame type for Netware 3 11 and earlier is 802 3 but it is changed to 802 2 in Netware 4 x and 3 12 You may check the content of NET CFG to see if the frame type is acceptable by the server If the frame type cannot be accepted by the server please edit NET CFG to change the frame type on the client site or add a frame type that can be accepted on the server site 2 lf you use the NE2000 driver the IRQ specified in NET CFG must be the same as the physical IRQ assignment by Card Service or L
16. e drive A 2 Change current drive to A 3 Run INSTALL EXE 4 Select Installation 5 Select Requester on workstation 6 Set Target Directory Assume C NETWARE 7 Click OK 8 Select Edit CONFIG SYS and Copy All Files 9 Click OK 10 Insert the diskette labeled WSDRV_1 and Click OK 11 Select NE2000 SYS driver 09 09 99 2 13 Bausch Datacom Pulsar 10 GENERAL INFORMATION 12 Click Continue 13 Insert the diskette labeled WSOS2 1 and Click OK 14 Click Continue 15 Select the SPX Support for OS 2 Sessions 16 Click Save 17 Click OK 18 Click Copy 19 Insert the diskette labeled WSOS2_2 and Click OK 20 Insert the diskette labeled WSOS2 3 and Click OK 21 Insert the diskette labeled OS2UTIL1 and Click OK 22 Insert the diskette labeled WSDRV 1 and Click OK 23 Insert the diskette labeled 052 1 and Click OK 24 Insert the PULSAR 10 Ethernet Adapter driver diskette 25 Close the Installation window to exit the installation 26 Copy the following driver to the CANETWARE directory COPY A3OS2YODNLE10ODI SYS CANETWARE COPY A OS2 ODI LANEN OS2 CANETWARE 27 EDIT CACONFIG SYS 28 Delete DEVICE C NETWARE NE2000 SYS For Example REM ODI Driver Files BEGIN REM DEVICE C NETWARE NE2000 SYS REM ODI Driver Files END 29 Add DEVICE C NETWARE LANEN OS2 DEVICE C NETWARE LE100DI SYS For Example REM ODI Driver Files BEGIN DEVICE C NETWARE LANEN OS2 DEVICE C NETWARE LE100DI SYS REM ODI Driver Files END 30 Save C CO
17. e installation program starts copying related files to the destination directory and modifies the AUTOEXEC BAT 15 Reboot the computer to load the driver ODI Driver for Workgroups 1 Run Windows for Workgroups and click the Network Setup icon in Network group 2 In the Network Setup dialog box click Networks to select the network operating system 3 In the Networks dialog box check Install Microsoft Windows Network and Others then select Novell NetWare Workstation Shell 3 X or Novell NetWare Workstation 4 0 and above and press OK to enter the screen of IPXODI COM and LSL COM 4 Press OK to go back to the Network Setup screen 5 Click on Drivers to select the network driver 6 In the Network Drivers dialog box press Add Adapter to enter the Add Network Adapter dialog box Select Unlisted or Updated Network Adapter and press OK 09 09 99 2 9 Bausch Datacom Pulsar 10 GENERAL INFORMATION 7 Windows will prompt an Install Driver dialog box Put the driver diskette in the floppy drive and press OK 8 Select the Netware ODI Driver string and press OK 9 Follow the Windows instructions to complete the installation and exit Windows 10 Run INSTALL EXE from the root directory of the driver diskette 11 Select Windows for Workgroups in the Network Operating System screen 12 If the current settings are acceptable select Start Installation and go to step 13 Otherwise select Modify Parameters to change the settings
18. e path and press OK 11 A dialog box will appear in which you can adjust the driver s settings The resources assignment of the adapter must be unique in the system 12 Click OK when all settings are completed 13 Click Close to complete the network settings 2 2 7 Windows 95 Installation 1 The drivers of the PCMCIA slot must be installed properly The System Icon in the Control Panel can report on its functionality Any questions regarding problems with the PCMCIA slot need to be taken up with the computer s manufacturer 2 Insert the PULSAR 10 Ethernet Card into the PCMCIA slot Select Driver from disk provided by hardware manufacturer in the New Hardware Found dialog box New Hardware Found 21x Ss Ethemet Adapter Select which driver you want to install for your new hardware Windows deraut diver Driver from disk provided by hardware manufacturer Do not install a driver Windows will not prompt you again Select from a list of alternate drivers OK Cancel f 3 Specify the path A and insert the driver diskette The driver will be installed and you may be asked for the original Windows 95 CD disks 4 For the first time installation please click Network in Control Panel to add the Protocols Client and Services needed 5 Reboot the machine and the Pulsar 10 will be fully functional 2 2 8 Windows 968 installation 2 2 9 Windows 2000 installation 09 09 99 2 11 Bausch Datacom Pulsar 10 GENERAL
19. iver 1 Copy the files LETOODI COM and NET CFG from the path NETWARE and the file LANEN EXE from the path ENABLER from the driver diskette to the Netware client directory containing Novell s LSL COM IPXODI COM and NETx COM files 2 Use a text editor to edit the NET CFG in order to set the frame type The frame type for Netware server is set to 802 3 for NW3 11 and 802 2 for NW3 12 and NW4 x The frame type must be set to the same type of the server or the client can not login to the server 3 Follow the Novell instructions on using ODI programs You can substitute the LE10ODI COM whenever a reference is made to the Hardware Specific Module 4 A typical ODI workstation startup batch file includes gt LANEN IRQ dd IOP xxx Card Enabler gt LSL Link Support Layer Module provided by Novell gt LE100DI Hardware Specific Module gt IPXODI IPX Protocol Stack Module provided by Novell gt NETx Shell Support Module provided by Novell gt LOGIN 09 09 99 2 4 Bausch Datacom Pulsar 10 GENERAL INFORMATION Novell Client Installation 1 Run the NetWare Client Install V1 21 Get the 4 Client disks from the network administrator or Run the NWCLIENT INSTALL EXE from a previous Installation 2 A message appears on the screen asking you whether or not you want the program to perform modifications on your AUTOEXEC BAT and CONFIG SYS files 3 Answer Yes The program then modifies your AUTOEXEC BAT and CONFIG SYS files and creates bac
20. kup copies 09 09 99 2 5 Bausch Datacom Pulsar 10 GENERAL INFORMATION 4 The following message appears Install support for MS Windows Y N 5 Answer accordingly and provide a path if necessary 6 The program displays the following Configure your workstation for backup by a NetWare server running software such as BACKUP Y N 7 Answer accordingly and provide a path if necessary 8 Select a driver for your network board 9 Select Other Drivers in the driver list 10 Go to the Insert the Driver Disk dialog box and specify the path where the ODI driver and INS files reside For example C ODI DOS 11 Press Enter and select the target ODI driver 12 Specify the driver s optional settings 13 Press F10 to save the new configuration 14 Highlight Install press here and press lt Enter gt to install The program copies the necessary files for NetWare Client Continue the installation procedure to completion Upon completion a new NET CFG file will be created in your DOS directory Typically this file contains the following lines Link Driver LE10ODI FRAME Ethernet_802 3 FRAME Ethernet_802 2 15 Copy the file LANEN EXE from the ENABLER directory on the driver diskette to the Netware Client directory 16 Edit the STARTNET BAT with a text editor Add and run the LANEN command at the beginning of the file The STARTNET BAT for the ODI workstation looks like this LANEN IRQ n Card Enabler SET NWLANGUAGE ENGLISH
21. oppy drive Then run INSTALL to install the real mode drivers such as ODI NDIS 2 x or Packet Drivers Network Operating System Microsoft LAN Manager Packet Driver Windows For Workgroup 3 11 LANtastic 6 8 Select Previous Screen 2 2 1 Novell Netware There are two methods to install the Netware client ODI driver the menu installation and the Netware 3 12 or 4 x Client installation Menu Installation 1 Run INSTALL EXE from the root directory of the driver diskette 2 Select the Netware 3 x and 4 x Workstation item from the menu 09 09 99 2 3 Bausch Datacom Pulsar 10 GENERAL INFORMATION 3 If the current settings are acceptable select Start Installation and go to step 5 Otherwise select Modify Parameters to change the settings 4 Move the cursor to the setting you want to change and press lt Enter gt to select a fit value When the configuration is finished press lt Enter gt on the OK field to exit the screen and go back to step 3 5 The installation program starts copying related files from the diskette to the destination directory and modifies the AUTOEXEC BAT and NET CFG 6 Now the installation is completed Reboot the computer to make your Netware connection PCMCIA Ethernet Card LAN IRQ Level LAN 140 Base Network OS Netware 3 x amp 4 x Frame Type Target Path Driver Install Modify Parameters Select Previous Screen Follow the instructions listed below to manually install the ODI dr
22. terrupt resource for you place a value of 0 at this location 3 2 NOTES FOR PACKET DRIVER The following are examples of a partial CONFIG SYS file for loading SystemSoft Card Services and the Packet Driver Examples of a partial CONFIG SYS file 09 09 99 3 1 Bausch Datacom DEVICE C CARDSOFT SS365SL EXE DEVICE C CARDSOFT CS EXE DEVICE C CARDSOFT CSALLOC EXE C CARDSOFT CSALLOC INI DEVICE C CARDSOFT CARDID EXE device c tcpip lanen exe device c tcpip le10pd sys 3 3 NOTES FOR WINDOWS FOR WORKGROUPS DRIVER The following are examples of a partial CONFIG SYS and AUTOEXEC BAT file for loading SystemSoft Card Services and drivers for Windows for Workgroups Examples of a partial CONFIG SYS file DEVICE C CARDSOFT SS365SL EXE DEVICE C CARDSOFT CS EXE DEVICE C CARDSOFT CSALLOC EXE C CARDSOFT CSALLOC INI DEVICE C CARDSOFT CARDID EXE device c wfw31 1 lanen exe DEVICE C WFW8311 IFSHLP SYS Examples of a partial AUTOEXEC BAT file CAWFW311 NET START 09 09 99 3 2 Bausch Datacom Pulsar 10 QUESTIONS AND ANSWERS 4 QUESTIONS AND ANSWERS This chapter provides a number of examples of Questions Q Causes C and Answers A If your LAN is not functioning properly look up the problem here or ask your dealer for technical assistance Q The Card Service cannot enable my card When run LANEN the error message shows Fail to enable PC card C No memory space to map the attribute memory of the PULSAR 10 card
23. ts with Libraries and add the line 09 09 99 4 1 Bausch Datacom Pulsar 10 QUESTIONS AND ANSWERS CardLib le10 clb before any other CardLib lines When the card is inserted you will hear a beep Use CARDCHEK V to check if the card has been configured correctly 3 If the card does not work properly you should edit the CARDID INI again to change the resources allocation In the Common section you may find the following strings Lan1Port 300 Lan1IRQ 5 Lan1MemoryBase1 DO LaniMemoryBase2 D4 Lan2Port 320 Lan2IRQ 11 Lan2MemoryBase1 D8 Lan2MemoryBase2 DC You may change the LaniPort or LaniIRQ to another value e g Lan1Port 320 Lan1IRQ 11 to make Cardsoft allocate the resources you want 4 f the resources cannot be allocated properly you may run CARDSOFT CONFIG or edit CARDSOFT CSALLOGC INI directly to make the system resources available for allocation The file content of CSALLOC INI is listed below The available resources described by the MEMs and IRQs lines It may have been altered by the xINCLUDE and or xEXCLUDE lines below The MEMS IO and IRQs lines are provided for Read Only purposes MEM D000 DFFF IO 100 3F7 IRQ 5 7 9 C E F Resource modifications should be made below this line RIO 170 177 370 377 MEMEXCLUDE C000 CFFF E000 EFFF IOEXCLUDE 3F8 3FF 2F8 2FF IRQEXCLUDE 3 4 6 13 14 You may edit the file to tell Cardsoft which resources are available