1. www schnickschnacksystems com 8 0 Declaration of Conformity SCHNICK SCHNACK SYSTEMS hereby declare that the product LED Beleuchtungssystem bestehend aus LED Systemnetzteil 4 ED Kachel B LED Streifen 25 mit Intelligenz und Verkabelung nach Bedienungsanleitung Name of product type or model batch or serial number meets the essential requirements referred to in Article 3 of the Council Directive 99 5 EC The following harmonized standards have been applied EN 60950 1 2003 EN 55015 2000 MANUFACTURER or AUTHORISED REPRESENTATIVE Address Schnick Schnack Systems GmbH Gunther Plueschow Strasse 6 50829 Koeln Ma Germany Tel 49 221 992 019 0 Fax 49 221 992 019 22 P d Koeln 7 5 February 2005 _ E sad vere TN ee OOO Place Date of issue Signature Dipl Ing FH Erhard Lehmann Pb a a Li www schnickschnacksystems com
2. amp dn OR CO e CO E CO Out 4 Out 3 Out 3 Out 1 DMX IN mains input Fuse 4 Fuse 3 Fuse 2 1 DMX OUT 100 250V AC DMX input and output Neutrik XLR 5 pin LED output 1 4 Neutrik XLR 4 pin Mains input Neutrik Powercon 100 250V AC 3 0 Setup Before connecting the unit to power make sure that the unit has not suffered any damages during trans port A damaged unit must not be connected to power If the Systemnetzteil 4 was transported from a cold enviroment into a warmer place make sure to let it warm up for at least 3 hours to allow condensing water to vaporate and to prevent risks to the electronics If the unit is rack mounted make sure that there is a sufficent supply of air on the back side as well as free air circulation on the front The temperature of the surrounding air should not exceed 35 95 F When installing the Systemnetzteil 4 into a rack we recommend the use of mounting tracks to relieve 4 0 System Wiring The Systemnetzteil 4 can be set up fexibly LED fixtures connect from one to another with 4 pin PCB connectors These connectors are small lightweight and inexpensive and ideal for the internal wiring Longer cable runs make use of the more durable XLR 4pin cables which have 2 wires for current and a shielded pair of data wires These cables are commonly used for colour changer systems The interface from the XLR cable to the PCB cable is the Adapterplatine a little PCB Per ou
3. 7 every seventh fixture has the same adress R8 Repeat 8 every eighth fixture has the same adress R9 Repeat 9 every ninth fixture has the same adress R10 Repeat 10 every tenth fixture has the same adress OFF No combination all fixtures on seperatly controlled adresses www schnickschnacksystems com 5 2 2 Manual RGB This menu function is used to output a defined colour on all fixtures on all outputs It can be used as a standalone solution if no DMX signal is present With EDIT you can choose the active input field with UP and DOWN you edit the content Simply set the intensity value for each colour from 0 to 255 to mix the desired colour output 5 2 3 Demo Fast Slow Manual Colour Mode aw 001 001 MESH 001 This mode runs a continious colour run on all connected LED fixtures As the names suggest the only difference between both modes is the running speed This mode is often used for system testing during setup Demo Mode Fast Demo Mode Slow 5 2 4 Manual Patch If you press SHIFT ENTER you can copy the contents of the Quickpatch into the maunal patch Be aware that this command cannot not be undone and a previously setup Manualpatch will be overwritten If you press QUIT the Manualpatch is not overwritten Setup Options in Manual Patch Input field Output number of the LED output on the Systemnetzteil 4 Input field Channel the channel on the selected output 1 60 channel 1 is t
4. SCHNICK SCHNACK SYSTEMS USER MANUAL LED POWER SUPPLY 4 Version 1 7 Mk2 english Content 1 0 2 0 3 0 4 0 4 1 5 0 5 1 5 2 5 2 1 23 2 2 5 2 3 5 2 4 5 2 5 5 2 6 6 0 1 0 7 1 8 0 SCH NICK SCHNACK SYSTEMS Overview Connectivity Setup System Wiring Example Wiring Schemes Menu Structure equence of Operating Modes Menu selection Quickpatch Manual RGB Demo Fast Slow Manual Patch Info Error Message Contact Technical Data Connector Wiring Declaration of Conformity www schnickschnacksystems com 1 0 Overview The LED Systemnetzteil 4 is the power and data To connect the LED Streifen you need Intelligences supply for the RGB LED Kachel B and the RGB LED to convert the control signal into LED dimming Streifen B The Systemnetzteil 4 features 4 independent outputs with XLR 4 pin Connectors Each output can be independently adressed Each output supports up to 20 Kachel B or up to The unit is able to control the connected 8 meter LED Streifen B25 250 or up to 4 meter LED fixtures even if there is no DMX signal LED Streifen B12 250 2 0 Connectivity You find the following connections on the back panel of the unit Air inlet Air inlet DO NOT COVER DO NOT COVER clean frequently clean frequently pt wem joba drip up Ro Ed ST i at a C protinr ted signal sutpoti ott a
5. he the red channel of the first connected LED fixture Overwrite Patch with Quickpatch Shift Enter Quit Value 0 MX eur 15 Input field Type select INT to output a constant value on this channel Select DMX to set a DMX input channel to this channel Input field Value Either the value of the constant intensity or the DMX input channel according to Type setting SCHNICK SCHNACK SYSTEMS 5 2 5 Info The menu function Info shows information on the S i chnick unit type and the version of the software on Schaack LED PSU4 the display Systems Version 1 7 5 2 6 Error Message If one of the outputs fuses fails the display backlight will start flashing and you will see the following Output Error display RADIO OK OK 6 0 Contact Schnick Schnack Systems GmbH Fon 0221 99 2019 0 Mathias Br ggen Stra e 79 Fax 0221 99 2019 22 50829 Koln info schnickschnacksystems com Germany www schnickschnacksystems com 7 0 Technical Data Housing 19 2 Height Units 2 HU 483mm x 88mm x 430mm WxHxL Operating Voltage 100 240 V AC 50 60 Hz Power consumption 700 VA Output current max 6 A per output Mains connector Neutrik Powercon DMX in Neutrik XLR 5 pin DMX out Neutrik XLR 5 pin Protocol DMX 512A 1990 USITT isolated and protected LED outputs 1 4 Neutrik XLR 4 pin Weight 1 1 kg 7 1 Connector Wiring DMX 4 XLR 4 Pol Ausgang 1 2 3 4 Housing 24 Volt
6. latine output to the loop input www schnickschnacksystems com 4 1 System Wiring Schemes The following wiring schemes give an overview on different wiring variants babi dami Sabi giii t IL E Il Systemnetzteil 4 DMX router amp power supply DMX XLR 5 pol cabel gt power amp DMX XLR 4 pol cabel amp pcb linkcabel 3 Output No 24V oc R G B anodes pcb linkcabel 3 Output No SCHNICK SCHNACK SYSTEMS a L a TP _ No 10 No 11 3 also with max 6A and 60 channels of DMX 4 also with max 6A and 60 channels of DMX www schnickschnacksystems com 5 0 Menu Structure Shift Edit Down Up Quit Enter 5 1 Menu Sequence Quickpatch Manual RGB Demo Fast Demo Slow Manual Patch 5 2 Menu Selection To go to the menu selection press the button QUIT and confirm the Question Change Mode with Change Mode ENTER The buttons UP and DOWN select the desired Quit Enter mode confirm selection with ENTER or press the QUIT button to go back to the recent running mode SCHNICK SCHNACK SYSTEMS 5 2 1 Quickpatch There are two setup entries for each output DMX G O O D Out Out ut Ou Every column represents one output The upper input 2 3 4 field labeled Start Ch shows the DMX starting eje 001 001 001 001 adress of the output The lower field Mode is Mode used to select patterns of channel combinatio
7. n and repetitions The active input field is indicated by an inverted display of the content To change to the next input field keep pressing the EDIT button until the display is inverted The UP and DOWN buttons change the contents of the active input field On the top left corner of the display you can find information on the recieved DMX signal NONE shows that no valid DMX signal is recognized G00D shows reception of DMX packets without errors The following table shows the combination modes Table of combination modes ALL all connected RGB LED fixtures work on 3 channels of DMX with the red LED starting on the selected start channel Combine C 2 Combine 2 2 LED fixtures are buddied together C3 Combine 3 3 LED fixtures are buddied together C4 a Combine 4 4 LED fixtures are buddied together C5 Combine 5 5 LED fixtures are buddied together C6 Combine 6 6 LED fixtures are buddied together C 7 z Combine 7 7LED fixtures are buddied together C8 Combine 8 8 LED fixtures are buddied together C9 Combine 9 9 LED fixtures buddied together C10 Combine 10 10 LED fixtures are buddied together Repeat R2 Repeat 2 every second fixture has the same adress R3 Repeat 3 every third fixture has the same adress R4 Repeat 4 every fourth fixture has the same adress R5 Repeat 5 every fifth fixture has the same adress R6 Repeat 6 every sixth fixture has the same adress R7 Repeat
8. tput SCHNICK SCHNACK SYSTEMS the front plate from mechanical load and to make servicing more easy Connect the DMX input and if necessary the DMX output as well as the LED outputs you are going to use Switch on the Systemnetzteil 4 by twist locking the powercon connector or activating the power supply There is no Main switch on the unit It will take about 1 second for the unit to be operative Do not operate the unit in direct sunlight Do not clean the Systemnetzteil 4 with aggressive solvents or water A moist towel will be sufficent in most times If necessary you might use a mild cleaner on the towel that features a XLR 4pin input a XLR 4pin output and two sets of PCB cable inputs and outputs If you place the Adapterplatine on the outside of a decoration element with LEDs inside you connect the elemnet to the Systemnetzteil 4 with the XLR 4pin cable and do the wiring inside the element with PCB cables The following table shows all possible combinations and the maximum number of LED fixtures 20 Kachel B or 6 Intelligenzes with 6 Streifen B25 250 each 36 Streifen total or 20 Streifen B25 2501 with Intelligenzes max 20 Intelligenzes max current 6 A max 60 DMX adresses max 20 m XLR 4pin cable to the Adapterplatine Per output of the Adapterplatine 10 Kachel B or 16 Streifen B25 250 or 8 Streifen B12 250 max current 3 A max 16 Intelligenzes max 6m pcb cable wiring from the Adapterp