1. Thank you for buying a high performance DLS Power Cap capacitor To avoid possible injury and damage to your audio system please first read this manual carefully before you start to install the Cap We recommend you to keep the manual and all original accessories including the charge discharge light bulb in the packing box for possible future use Operating features The Power Capacitor is an energy storage capacitor It is designed to supplement audio amplifiers power supply during high current demand The overall bass response of your audio system will be enhanced with the using of this device due to it s ability to store a large amount of current and discharge it in a short period of time Combined with a good car battery and powerful DC wiring will make you experience a new dimension in the bass sound Another significant feature of the Power Cap is it s ability to filter noise induced in the system by the amplifiers power supply or from the car alternator which could cause objectionable noise to be induced into the audio system We recommend using a capacitor of 1 Farad for each 500 Watts amplifier power You can never have too much capacitance in an audio system Installation The Power Cap should be mounted as close to the amplifier as pos sible and keep the wires short to reduce voltage drop in the cable Use the two mounting brackets to fix the capacitor near the amplifier The Power Cap may be mounted in any position
2. Care should be taken to ensure the venting plug on capacitors top is unobstructed at all time The plug is a pressure relief valve when the polarity be comes reversed If reversed voltage is applied to the capacitor fluid will leak through this vent plug and rendering the capacitor useless Wiring Use the same cable area to the capacitor as to the amplifier The Po wer Cap should be fused at the battery don t place any fuse between the Power Cap and the amplifier Mount the fuse as in the drawing below Use the same cable area for the ground wire The capacitor should be connected in parallel with the positive feed to the amplifier If you have a model with the power block included on the top of the capacitor use this for connecting Capacitor with power block w o DVM A small wire must be connected between the amplifier remote and the remote terminal on the ca pacitor This is for starting the LED display To amplifier remote Battery Technical Assistance For technical assistance ask the shop where the product was sold or the distributor in your country You can also send an e mail to info dis se Warranty service This product is covered by warranty depending on the conditions in the country where it is sold If it is returned for service please include the original dated receipt or a copy with the product DLS Svenska AB 2009 05 04 Safety Considerations To prevent injury and damage to the product p
3. ed when the bulb stops to glow and can be stored away Discharging with the bulb in parallel with the and termi nals Don t hold the bulb with your fing ers it becomes hot More facts Capacitance 1 Farad 1 Farad with DVM Both models have a power block installed Max voltage 20 DCV 20 DCV Tolerance 10 50 10 50 Max temp 95 C 95 C Size TT X 243 mm TT X 243 mm Art no 10 49510 10 49511 DLS Svenska AB P O Box 13029 SE 402 51 G teborg Sweden Phone 46 31 84 00 60 Fax 46 31 84 40 21 E mail info dls se www dls se Tack f r att du k pt en DLS Power Cap kondensator Det r viktigt att du l ser denna bruksanvisning f re installationen den inneh ller viktig information Felaktigt f rfarande vid inkopplingen kan f rst ra kondensatorn Vi rekommenderar att du sparar f rpackningen med bruksan visningen sexkantnycklarna och lampan som medf ljer de kan beh vas i framtiden Funktion En Power Cap kondensator fungerar som en energireserv d r f rst r karen kan h mta extra str m vid stora effektuttag t ex vid kraftiga at tacker i basen Bas tergivningen i ett ljudsystem r beroende p om f rst rkaren f r all den str m som kr vs i alla gonblick annars blir basljudet tr tt och anstr ngt och kommer att sakna den riktiga Sn r ten En DLS Power Cap ger snabbt f rst rkaren den extra str m som erfordras Att dessutom kombinera med ett bra batteri och kraftiga str mkab
4. kopplad till jord Uppladdningen tar ca 60 sekunder Kondensatorn kan skadas om den inte laddas upp med en lampa f re inkoppling f rsta g ngen F rst lyser lampan med starkt sken f r att sedan avta N r lampan slocknat r konden satorn laddad och d kan pluskabeln kopplas in permanent Om du tappat bort den medf ljande lampan s kan du an v nda en 12 Volt 1 2 Watts gl dlampa for bil OBS Om du kopplar in 12 volt direkt utan att f rst laddat upp kondensatorn s f rst rs den Laddas med lampan i serie med kabeln till terminalen H ll inte i lampan den blir varm Laddtid 60 sekun der Urladdning av kondensatorn Om kondensatorn kopplas ur systemet f r att inte anv ndas igen p ett tag skall den laddas ur Urladdning g rs med samma lampa som anv ndes vid uppladdning Koppla lam pan direkt mellan plus och minuspolen p kondensatorn och ha den kvar tills den slocknat Laddas ur genom att koppla lampan mel lan och anslut ningarna H ll inte i lampan den blir varm Mer fakta Kapacitans 1 Farad 1 Farad med DVM Bada modellerna har monterat power block Max spanning 20 DCV Tolerans 10 50 10 50 Max temp 95C 95 C Storlek TT X 243 mm 75 X 243 mm Art nr 10 49510 10 49511 DLS Svenska AB Box 13029 402 51 G teborg Tel 031 84 00 60 Fax 031 84 40 21 E mail info dls se www dls se
5. lar g r att du kommer att uppleva en helt ny dimension i basljudet En annan f rdel med en Power Cap r att den fungerar som en filter kondensator som hj lper till att effektivt filtrera bort st rningar som genereras i f rst rkarens n tdel eller fr n bilens generator Vi rekommenderar en kondensator p 1 Farad f r varje 500 Watts f rst rkareffekt Du kan aldrig ha f r stor kondensator Installation Kondensatorn skall monteras s n ra f rst rkaren slutsteget som m jligt H ll kablarna s korta som m jligt Anv nd de b da byg larna f r att f sta kondensatorn Kondensatorn kan monteras st ende eller liggande Se till att ventilen p kondensatorns ovansida inte kan p verkas Detta r en tryckventil som ppnar om kondensatorn kopplas in med felaktig polaritet Om den kopplas med fel polaritet ppnas ventilen och det kommer ut kondensatorv tska fr n ventilen dessutom blir konden satorn obrukbar Kabeldragning Anv nd samma kabelarea till kondensatorn som till f rst rkaren Anv nd ingen s kringsh llare mellan kondensator och f rst rkare S kring skall i st llet monteras n ra batteriet enligt skissen nedan s att den avs krar b da f rst rkare och kondensator Anv nd samma kabelarea ven till jordanslutningen med kortast m jliga kabel Kon densatorn kopplas allts parallellt med plusmatningen till f rst rkaren s n ra denna som m jligt Har du k pt en kondensator med inbyggt powerblock a
6. lease read and follow the instructions in this manual If you feel unsure about installing the system yourself have it installed by a qualified DLS installer Observe polarity during installation to eliminate the pos sibility of damaging the capacitor the battery or other as sociated equipment Charging the capacitor Before connecting the capacitor in the system it must be charged slowly The charging process is accomplished by connecting the attached light bulb in series between the bat terys positive pole and the capacitors positive terminal see the photo below Connect the negative terminal to ground At first the bulb glows but after 60 seconds the lamp stops to glow Now the capacitor is fully charged The capacitor can be damaged if it s not charged with a lamp the first time it s used If you have lost the original lamp you can charge recharge the capacitor with the use of a 12 volt 1 2 Watt vehicle lamp NOTE Never connect 12 Volt to the capacitor without charging it this will destroy the capacitor Charging with the bulb in series with the terminal Don t hold the bulb with your fingers it becomes hot Charging time 60 seconds Discharging the capacitor The capacitor must be discharged when it is removed from the system Simply place the same buld that was used in the charging process across the terminals of the capacitor to eliminate the stored power the capacitor will be fully dischar g
7. nv nds detta f r inkoppling Kondensator med power block utan DVM En tunn kabel m ste anslu tas mellan kondensatorns lilla uttag och f rst rkarens remoteing ng Detta f r att LED displayen ska t ndas n r f rst rkaren startar S kring Kondensator med DVM power block S kring Till f rst rka rens remote Batteri Teknisk hj lp Beh ver du teknisk hj lp s v nd dej i f rsta hand till den butik som s lt produkten Du kan ven kontakta DLS p telefon 031 84 00 60 eller skicka ett e mail till info dls se Garantiservice DLS l mnar ett rs garanti mot material och fabrikationsfel Vid re klamation skall kopia av kvitto eller annat k pbevis bifogas repara tionen DLS Svenska AB 2009 05 04 T nk p s kerheten F r att undvika skada p person eller produkt l s f rst igenom bruksanvisningen noggrant innan du p b rjar installationen Om du k nner dig det minsta os ker hur du g r s verl t installationen till en kvalificerad installat r Var noga med att du kopplar in med r tt polartitet Vid felaktig inkoppling kan du skada kondensatorn batteriet eller annan elektrisk utrustning i fordonet Uppladdning av kondensatorn Innan kondensatorn kopplas in i systemet skall den laddas upp l ngsamt Detta sker med hj lp av den bipackade gl d lampan Denna kopplas i serie med pluskabeln fr n batteriet enligt bilden nedan Minuspolen p kondensatorn m ste ock s vara

Download Pdf Manuals

image

Related Search

Related Contents

Guía de configuración  STELA V2 5 2 release note  保証書 商品修理規定 も く じ - スターバックス コーヒー ジャパン  SAR User Manual v2.2 - Ministry of Forests, Lands & Natural  ES 3584 Bedienungsanleitung/Garantie  GB Power Planer Instruction Manual F Rabot - MHD  Samsung Ativ S Bruksanvisning  NEWCAT manual,part1 - ProNivo Messgeräte Handels  LG GSL545WBYV side-by-side refrigerator  User manual - Hire Destination  