Home
        User Guide*
         Contents
1. Calibration    For calibration  see manufacturer   s instruction guide or contact Liko     Accuracy class     Readout   Tolerance     Max  load   Min  load   Reset    Power supply     Technical Data    Class III according to the requirements of the  NAWI 90 384 EEC Directive    Sensitive to 0 2 kg   10 99 9 kg     0 2 kg   100 350 kg     0 4 kg   350 kg  772 Ibs    10 kg  22 Ibs    One button reset  9    Battery 9 V                Battery  9 V Alkaline  PP3  MN1604  6LR61  E block   S  Battery life  about 3000 readings S   Display  Digital  liquid crystal  LCD  2   Size  76 x 76 x 134 mm  3 x 3 x 5 3 in    W x Lx H   gt    Weight  0 575 kg  1 3 Ibs  o   Temperature range   5  C to  35  C   41  F to  95  F    Humidity range  0  95    J Lik   4 UKO   A CES company www liko com   Distributor  Manufacturer    Liko AB SR Instruments  Inc      SE 975 92 Lule   600 Young Street            Sweden Tonawanda  NY 14150     info liko se USA N    Ii      J Liko  a CED company    User Guide     7EN160175 04  2009 08 10            lt  000 0    Liko                        v       LikoScale 350  Prod  No  3156228    LikoScale 350 is a convenient  easy to use scale that is intended for weighing patients   in Liko mobile or stationary lifts  Together with Liko   s lifts and lifting accessories    LikoScale 350 enables safe and easy weighing    The weight is shown on the scale   s digital display in kg    LikoScale 350 is certified according to the European directive NAWI 90 384  Non Automatic  
2. Installation of battery    1  Open the door on the back of the scale   2  Install the battery    3  Close the door     When the battery needs to be replaced  a small battery symbol will  appear in the upper left corner of the display     NOTE  Old batteries should be left at the nearest recycling station     Assembly Instructions  Follow the assembly instruction for the appropriate Liko lift     Likorall  MasterLift  Golvo  Fixed assembly    as  Always use one of the sleeves  included with the scale     1  Remove the lifting accessory from the lift     2  Place one sleeve on the scale   s lower attachment point   Mount the lifting accessory under the scale  using bolt  and locking nut provided     3  Mount the scale on to the lift  using bolt and locking nut  provided  N        Sleeve       Viking  Uno  Fixed assembly with adapter  Always use two sleeves  included with the scale         1  Remove the lifting accessory from the lift  Ci    2  Mount the appropriate adapter  see previous page   on to the lift in accordance with the assembly instruction     3  Place one sleeve on the scale   s lower attachment point   Mount the lifting accessory under the scale  using bolt and  locking nut provided  pi   4  Place one sleeve on the scale   s upper attachment point     i   Mount the scale in its upper attachment to the adapter  using a caer    bolt and locking nut provided        A When disassembling the scale  the adapter must be removed from the lift  before a lifting accessory i
3. Weighing Instruments   The scale should only be used in combination with approved lifts  and accessories in accordance with the instructions in this guide           LikoScale 350 can be used with the following Liko lifts    Viking  S  M  L  XL      require Adapter 12 mm  Prod  No  2016504    Uno  all models       Uno models with serial numbers from 31825 require  Adapter 12 mm  Prod  No  2016504      Uno models with serial numbers up to 31824 require  Adapter 8 mm  Prod  No  2016502     As the lifting height is limited when LikoScale is used in combination with LikoLight or Viking XS  we  do not recommend these alternatives     Golvo  all models     Likorall  all models   Multirall  all models     Liko MasterLift  all models          This user guide is a complement to the complete documentation issued by the manufacturer of the  scale  The intention with this document is to make it easier for our customers to use LikoScale in com   bination with Liko   s products  For detailed information regarding the scale we refer you to the manufac   turer   s instruction guide  attached            Before assembly  make sure you have the following       Tool kit  2 screws  2 locking nuts e Certificate of EU approval  e 2 sleeves e Declaration of Conformity  e Battery e Instruction Guide from manufacturer  e User Guide from Liko e Declaration of Calibration       Installing replaceing the battery    LikoScale 350 is delivered with a 9 V battery with a battery life of about 3000 readings   
4. s reassembled on to the lift     2 www liko com       Multirall  Likorall 200   R2R  Quick release assembly    Liko lifts equipped with  Q Link  quick fastener require the  Adapter Kit LikoScale  Prod  No  3156232    Always use one of the sleeves  included with the scale     Mount the Adapter Kit LikoScale in accordance with the  assembly instruction           Operation  The normal range for operation of LikoScale 350 is a temperature between  5  C and   35  C   41  F and  95  F  at a relative humidity not exceeding 95    The scale must not be stored at temperatures below  20  C or above  50  C   4  F and   122  F    When the scale is stored for more than 6 months  the battery should be removed   Follow instructions for installing replaceing the battery     Before weighing  ensure the scale has been installed in accordance with the Assembly  Instructions on pages 2 3     A Before lifting  check that the lifting accessory is hanging vertically and can  move freely     Weighing with LikoScale 350   The scale can be reset to zero with or without the sling  If the scale is reset to zero   without the sling attached to the sling bar  the weight of the patient will include the weight   of the sling  Therefore the weight of the sling must be subtracted to obtain the correct  weight of the patient    Resetting the scale with the sling is described below    1  Connect the sling to the sling bar    2  Start the scale by pressing the    button    3  Reset the scale by pressing the   but
5. ton    Dashes will move across the display for a few seconds while the scale is resetting   When the scale is ready  the value    0 0    will appear on the display   Note  No more than 35 kg  77 Ibs  can be tared to zero    4  Remove the sling from the sling bar and apply the sling to the patient in accordance  with the instruction guide for the sling and lift  Connect the sling to the sling bar    5  Raise the sling bar so the patient rises slightly  Never lift a patient higher than  necessary    6  When the lifting motion has stabilized  press the F button  The patient   s weight can  now be read on the display  The scale turns off automatically after about 60 seconds   For further readings  press the f   button    7  Lower the patient carefully and remove the sling from the sling bar     www liko com    
    