LCM-40(DA), LCM-60(DA) installation manual

image

Contents

1. 2 Connection of LED Lamps Press down the push button by a slotted screw driver to insert or remove the cable Vi oo A 0 e ka Vor o an az oft of ACIN o NEUTRAL Blue or white ACIL 90 LIVE Brown or black http www meanwell com 3 Connection of Dimming Functions a 0 10Vdc or 10V PWM non DA version only c Push dim DA version only PUSH Push Button oo000 AC N AC L o NEUTRAL Blue or white o LIVE Brown or black Note ONLY use open push button without indicator light Warning Risk of short circuit The push button can only be linked between the PUSH and the AC L brown or black DALI DA version only DA DA ooo000 ALI controller Note Maximum DALI cable length is 300m based on a 1 5mm or 14AWG cable DO NOT connect the push button to the AC N blue or white Dimming control mechanism Function Pushing time It will always dim up when light intensity is lower than 10 whereas it will j j j H i i 9 Turn ON OFF OA wees always dim down when light intensity is higher than 90 Factory dimming setting 100 Dim UP DOWN 1 5 10 sec Reset
2. LCM 40 DA LCM 60 DA installation manual hat GOW WWW o sev AN se CE Features 180 295VAC input only Class I power unit ungrounded Built in active PFC Built in 12V 50mA auxiliary output Output current level selectable by DIP switch Full plastic case enclosed Built in DALI interface and push dimming function DA version No load power consumption lt 1W 1 2W for DA version e Built in 0 10Vdc and PWM signal dimming function Non DA version Protections Short circuit Over voltage Over temperature Power supply synchronization function up to 10 units 3 year warranty Temperature compensation function by external NTC Suitable for intelligent LED lighting Wiring Housing with cable clamp for remote installation Use wires with an adequate cross section see 5 Use suitable mounting tools to do the wiring and mounting see 5 Use a MCB miniature circuit breaker with an adequate current rating to protect the lighting system see 6 Environmental limitations Maximum ambient temperature must not exceed 60 C Always allow adequate ventilation clearances 50mm around the unit in use to prevent it from overheating Only install the unit in interior environments Cautions This unit must be installed by a qualified electrician e This unit is not suitable for applications that DC DC converters are connected before LED lamps Settings and connections 1 Output Current Level Settings The L
3. 16 c10 C16 LCM 40 DA 10 16 17 28 LCM 60 DA 9 15 16 26 Note These calculated values are based on MCB S201 series manufactured by ABB http www meanwell com
4. CM can provide various output currents by setting the DIP switch The settings of the DIP switch are shown in the tables below LCM 40 DA LCM 60 DA uae a ais 4s weena 2 14100V 350mA 2 90V 500mA lt a 2 80V 500mA ON 2 90V 600mA ON 2 67V 600mA ON ON 2 86V 700mA ON ON 2 57V 700mA ON ON ON ON 2 67V 900mA ON ON ON ON 2 45V 900mA ON ON ON ON ON 2 57V 1050mA ON ON ON ON ON 2 40V 1050mA ON ON ON ON ON ON 2 42V 1400mA ON ON ON ON ON ON Note 1 Factory default setting is 700mA 2 Output voltage and output wattage must not exceed the rated values Terminal blocks assignment for LCM 123 5mm 23mm Fae CT 732 B88 EE ol Zm Vo Vo oo oo DM DIM NTC NTC FAN HO FaN O 81 5mm DA DA PUSH ACIN ACIL W If 000 00
5. gt 11 sec None lt 0 05 sec d Synchronization operation The lights driven by LCM units slaves can be dimmed synchronously through a LCM unit the master directly controlled via 0 10Vdc 10V PWM DALI or push dim dimming function The wiring is shown as below Master Slave 1 Slave 2 SYN SYN SYN Mating housing for SYN connectors JST B2B XH or equivalent Maximum number of the LCM units 10 1 master 9 slaves Maximum cable length between each units 20m based on a cable with cross section of 0 15mm 0 3mm or AWG No of 22 26 Note DO NOT connect dimming circuitry to slaves 4 NTC Connection NTC NTC 5 Recommended Screwdriver Wire and Torque Setting The cover Screw terminal Push terminal Type the blue one FAN NTC DIM ACL N PUSH DA Vo Solid wire wee p 0 404 1p 0 643MM p 1 024 1 628mm Stranded wire 7mm 0 27 3mm Philips 2 88 kgf cm 2 5 Ib in 10mm 0 39 3mm Philips American wire gauge Wire stripping length Screwdriver 6mm Philips 4 6 kgf cm 4 Ib in Recommended tightening torque Suggested push down strength 3 4 kp 1 36 1 81 IbF 6 Suggested Maximum Number of the LCM Units that can be Connected to a MCB miniature circuit breaker at 230Vac Model B10 B