        User's manual Primor 2000 / Level 15
         Contents
1.     9 Power supply and battery change    The lock is power supplied by one 9 V block battery alkaline  no rechargeable batteries    When battery voltage is insufficient   after entering the code a warning tone occurs repeatedly and the red LED flashes alternately  Change the battery as quickly as  possible  The programmed codes stay valid during battery change    Always dispose used batteries in an environmentally friendly way        Fig  1   Input unit Primor RO       8 04 05 2012    
2. Ce WITTKOPP       User   s manual  Primor 2000   Level 15       Content    1 General instructions       1 1 Liability notes       1 2 Operating notes       1 3 Notes on safety       2 Visual and acoustic signals       3 Input unit       4 Operating the lock       4 1 Opening       4 2 Locking       5 Programming the lock       5 1 Master and user codes       5 1 1 Programming a user code  programme 1        5 1 2 Changing the master or user code  programme 0        5 1 3 Deleting a user  programme 3        5 2 Time delay and opening window       5 2 1 Adjusting the time delay and opening window  programme 9     5 2 2 Opening with activated time delay and opening window          5 2 3 Deleting the time delay  programme 9        5 2 4 Opening with the instant opening code       6 Operation blocking  programme 2        7 Overview users  programme 7        8 Testing the system  programme 5        9 Power supply and battery change    co CO NN N OBO Oo Oo fF HR KR BR FBP Ww Ww WB WwW NY NY NY NY WN          Carl Wittkopp GmbH   Errors and omissions excepted       User   s manual no  9999 116 1    CeWITTKO PP Primor 2000   Level 15       1 General instructions    e Please read the operating instructions carefully  before activating the lock     1 1 Liability notes    e We don   t assume liability for malfunctions due to incorrect operation  use of force or inappropriate handling  In cases of  damage to property or valuables  which are due to incorrect locking of the safe  we also do
3. n   t assume liability   e If your safe  however  does not open correctly with the following instructions  please contact the manufacturer of the safe     1 2 Operating notes    e Assess a person to administer the lock  This person will be the master  Up to 9 users can be programmed  They receive PIN  1 9  PIN   Personal identification number    The code of the user 9 is also the instant opening code when a time delay is  activated    e When programming  the electronic lock has to be opened    e If the lock is not opened or closed within 3 seconds after entering the code  the electronics switch off  Re enter the code and  repeat the process    e When the time between touching keys exceeds 10 seconds the process of programming and entering is deleted  The old  code or programmes stay valid    e Every correct input while entering the code is confirmed by an acoustic signal and flashing of the red LED  These signals will  not be considered in this instruction    e The red LED flashes during the whole process of programming  These signal will not be considered in this instruction    e Never use force    e Do not open the lock case  otherwise you compromise the function of the lock and warranty will be void     1 3 Notes on safety    e For your security  change the factory code 1 2 3 4 5 6 7 immediately    e For your new code  do not use any personal data like birthdays or any other data  which could be known by knowledge of  your person    e After entering the new code  the elect
4. ndow e g           AJi2J s 4J s  sj 7        Input unit Primor RO    The lock is opened           Turn the input unit clockwise within 3 seconds into opening position                    e An active time delay can be interrupted by pressing any key     5 2 3 Deleting the time delay  programme 9   The time delay can only be deleted within the opening window   The opening window runs after deleting the time delay for the last time           1    Enter your 7 digit code e g  mastercode           Gangoor       2    Wait until the end of the time delay        3    Opening window starts                                               4    Press and hold the key    9    until the red LED flashes permanently       EE  a  5    Enter your 7 digit master code e g  aesae  EE    6    Delete the time delay  ofo   7    Delete the opening window  og EE l  8    Delete the time delay again   o  o   9    Delete the opening window again   oj  EE D             04 05 2012          Primor 2000   Level 15 CeWITTKO PP       5 2 4 Opening with the instant opening code    The instant opening code is meant to bypass the time delay        The instant opening code is assigned to user 9  A corresponding user code has to be activated                 The code that is entered first  must not be identical to the code of user 9  vA X  1    Enter your 7 digit code e g  mastercode  Cejas  EE    2    Time delay starts  xy             3    Enter your 7 digit instant opening code e g   eje joj ojo  ejo  EE      Input u
5. nit Primor RO       Turn the input unit clockwise within 3 seconds into opening position                 The lock is opened              6 Operation blocking  programme 2           Only the master can enable or disable all user codes at the same time   Have user codes been disabled  the lock can be opened only with the master code  id xX       1    Press and hold the key    2    until the red LED flashes permanently   2  EE m             2    Enter your 7 digit master code e g  Jiejia  EE  m                         7 Overview users  programme 7        This function provides an overview of the number of free or already occupied users                       Only the master can perform this function  Z x  1    Press and hold the key    7    until the red LED flashes permanently   7  EE    2    Enter your 7 digit master code e g  aesae  EE a  3    Enter the user PIN that has to be checked e g  users 3  5  6     3   5  ion ee ocoupied  4    End the query   o  LE                               04 05 2012 7    CeWITTKO PP Primor 2000   Level 15       8 Testing the system  programme 5        Press every number once  A functional key will be confirmed by a double signal  A key that was not identi        fied is confirmed by a long signal and the functional test is aborted  The system has to be checked  Ya bd  1    Press and hold the key    5    until the red LEDs flash permanently   5  EE                           2    Press every key in its order of appearance  Oefa     J o  an        
6. rogramme 1  ral x  The master is able to program a user code  but not vice versa   1    Press and hold the key    1    until the red LED flashes permanently   J EE    2    Enter your 7 digit master code e g  Haagen an    3    Enter the user PIN e g  user 3   3  EE D             4    Enter the new 7 digit user code e g  Wooo ES E ED is                  5    Re enter the new 7 digit user code e g  ooo ES ET E EE                           e A new user code will be allowed only if the code is differing in two places by a single digit from an existing code   e Should the new code be denied  restart the process of programming        5 1 2 Changing the master or user code  programme 0  Z       1    Press and hold the key    O    until the red LED flashes permanently   o  an      2    Enter your old 7 digit code e g  user code  ojo ES ES E E an    3    Enter your new 7 digit code e g  5  6  7  8  oJ iJ 3  an    4    Re enter your new 7 digit code e g     s 6j7J 8  oJ ij 3  an i    e A new user code will be allowed only if the code is differing in two places by a single digit from an existing code   e Should the new code be denied  restart the process of programming                                                                          5 1 3 Deleting a user  programme 3  s      x  The master is able to delete a user  but not vice versa   1    Press and hold the key    3    until the red LED flashes permanently   3  an    2    Enter your 7 digit master code e g  OJ  EE    3    Enter 
7. ronic lock should be opened and locked several times with the safe door opened    e After each locking doublecheck if the safe is closed     2 Visual and acoustic signals                            Signal Explanation Comment  S Right code  xX Wrong code or code denied  a Short signal  Es Long signal  LED flashes every 10 seconds Blocking time is active   i LED flashes every 2 seconds Time delay is active   ELL Battery warning Battery should be changed soon                       2 04 05 2012    Primor 2000   Level 15 CeWITTKO PP       3 Input unit    Primor RO    2  5  118  0    WITTKopp       4 Operating the lock       4 1 Openin  p g ei x             1    Enter the 7 digit code e g  master code  CJs  EE m    Input unit Primor RO       Turn the input unit clockwise within 3 seconds into opening position   The lock is opened                          e After 4 consecutive wrong code inputs  a blocking time of 5 minutes occurs  During this blocking time the red LED flashes  every 10 seconds and every input is accompanied by a long signal tone  After the blocking time has passed 2 further incor     rect inputs will restart the blocking time     4 2 Locking          Input unit Primor RO    Close the door at the safe and turn the input unit counterclockwise into  locking position  The lock is closed                          04 05 2012    CeWITTKO PP Primor 2000   Level 15       5 Programming the lock    5 1 Master and user codes                      5 1 1 Programming a user code  p
8. the user PIN of the user who has to be deleted e g  user 1  OJ EE                              4 04 05 2012    Primor 2000   Level 15 CeWITTKO PP       5 2 Time delay and opening window  Only the master can program or delete the time delay     Time delay  01   99 minutes   time to wait until the lock can be opened   Opening window  01   19 minutes   within this time window the master or the user can open the lock with his code     Code input     beginning of the time delay    Wait during the time delay       Opening window     re enter code                                     5 2 1 Adjusting the time delay and opening window  programme 9  p M  1    Press and hold the key    9    until the red LED flashes permanently       EE  acest  2    Enter your 7 digit master code e g  ulej sjaje  EE E  3    Enter the time delay e g  20 minutes   2Jo    4    Enter the opening window e g  10 minutes  Ujio  EE D  5    Re enter the time delay e g  20 minutes   2Jo   6    Re enter the opening window e g  10 minutes  Ujio  EE                              e The time delay can be increased at any time  It can be reduced only during the opening window        04 05 2012 5       Ce WITTKOPP    Primor 2000   Level 15       5 2 2 Opening with activated time delay and opening window          1    Enter your 7 digit code e g  mastercode           AJ2Js 4J s 6J7        2    Wait until the end of the time delay        3    Opening window starts        4    Re enter your 7 digit code within the opening wi
    