1. UPS e Do not attach non computer related items such as medical equipment life support equipment microwave ovens or vacuum cleaners to UPS e To reduce the risk of overheating the UPS do not cover the UPS cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces Unplug the UPS prior to cleaning and do not use liquid or spray detergent Do not dispose of battery or batteries in a fire The battery may explode Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic A battery can present a risk of electrical shock and high short circuit current The following precautions should be observed when working on batteries 1 Remove watches rings or other metal objects from the hand 2 Use tools with insulated handles 3 Wear rubber gloves and boots 4 Do not lay tools or metal parts on the top of batteries 5 Disconnect charging source prior to connecting or disconnecting batteries terminal Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When replacing batteries replace with the same number of the sealed lead acid batteries This pluggable type A equipment with battery already installed by the supplier is operator installable and may be operated by
2. p A N 6 Serial Cable Connection To allow for unattended system shutdown for your operating system connect the serial cable as per diagram below 7 Turn On Off To turn on the UPS unit press the power switch lightly To turn off the UPS unit press the power switch again When Switch ON The LED lighting 8 LCD Display Specification The LED will always turns on when UPS works including in off charging mode and fault mode When LCD start to work it will display all information for 3s INPUT BATTERY Unit VDC HzZ VAC OUTPUT LOAD FAULT Unit Hz VAC LOAD LEVEL BATTERY CAPACITY LINE MODE AVR BACKUP MODE 1 When in normal mode it will display as below High Voltage Version Low Voltage Version s EN ds EA INPUT OUTPUT Ay LINE MODE 2 nani B mu Ml E Ag LINE MODE lt 2 mee E null 2 When in AVR mode it will display as below And the mark gt will flicker every 1second High Voltage Version Low Voltage Version Ju Jani a AL INPUT OUTPUT OUTPUT So LINE MODE AVR 8 yy E Ag LINE MODE AVR 28 mul mul 3 When in battery mode it will display as below And the mark will flicker every 1second High Voltage Version Low Voltage Version ninia ar KALAK JH INPUT OUTPUT ios A J BACKUP MODE J Note If I P V lt 40V gt in
3. 3 Battery defect due to 3 Replace with the same type high temperature of battery operation environment or improper operation to battery 1 Software is not 1 Check the setting of the installed well software 2 Cable is not properly 2 Check the RS 232 or USB connected cable is firmly connected to COM1 COM2 of the computer and confirm the setting again broken properly Specification MODEL 100 1400 2000 CAPACITY 1000VA 600W 1400VA 840W 2000VA 1200W Voltage 110 120VAC or 220 230 240VAC INPUT aa 89 145VAC 81 145VAC as 9 162 290VAC 166 290VAC Voltage 110 120VAC or 220 230 240VAC Voltage Regulation ge nae AR Mode Oe OUTPUT Frequency 50Hz p BOHz or 6OH2 sid p BOHz or 6OH2 sid aed oo nggi mens Modified Sine Wave Battery Type 12V7Ah x 2pcs 12V9Ah x 2pcs Back up Time at 2 PC l TOONS 10 307e 6 Hours to 90 after complete Recharge Time after complete discharge discharge 7 TRANSFER l TIME 4 6ms Typical 4 8ms Typical AC Mode Backup INDICATOR a Fault Introduce as Front Panel LCD Backup Mode Mode Sounding every 10 seconds AUDIBLE Battery Low Sounding every 1 second ALARM Overload Sounding every 0 5 seconds PROTECTION Full Protection Overcharge and Overload Protection Overcharge and Overload Protection Overload Protection PHYSICAL A La a rx YY 405 x 205 x 145 mm WEIGHT Net Weight 9 7Kgs LV1400VA 2000VA 12Kg 0 40 C 0 90 Relative Humidity non condensin E
4. NVIRONMENT Operating Environment y 9 Noise Level Less than 45dB Windows family Sun Solaris IBM Aix Compaq True64 0 Jaa UnixWare FreeBSD HP UX Linux and MAC USB Optional Windows family and MAC
5. USER MANUAL Line Interactive 1000VA 1400VA 2000VA Uninterruptible Power System 614 06762 00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive 1000VA 1400VA 2000VA that should be followed during installation and maintenance for the UPS and batteries Safety CAUTI ON e This UPS utilizes voltages that may be hazardous Do not attempt to disassemble the unit The unit contains no user serviceable parts Only factory service personnel may perform repairs e Internal battery voltage is 12Vdc or 24Vdc Sealed lead acid 6 cells battery e Connection to any other type of receptacle other than a two pole three wire grounding receptacle may result in s shock hazard as well as violate local electrical codes e In the event of an emergency turn the power switch to the off position and disconnect the power cord form the AC power supply to properly disable the UPS e Do not allow any liquids or any foreign object to enter the UPS Do not place beverages or any other liquid containing vessels on or near the unit e This unit intended for installation in a controlled environment temperature controlled indoor area free of conductive contaminants Avoid installing the UPS in locations where there is standing or running water or excessive humidity e Do not plug the UPS input into its own output e Do not attach a power strip or surge suppressor to the
6. laymen During the installation of this equipment it should be assured that the sum of the leakage currents of the UPS and the connected loads does not exceed 3 5mA The mains socket outlet that supplies the UPS shall be installed near the UPS and shall be easily accessible System Description Front Panel 1 LCD Back Light 4 2 Power ON OFF Switch 2 Back Panel 3 USB Port Option 7 Circuit Breaker 4 RS232 Port 8 AC Output 5 Cooling Fan 9 AC Input 6 Modem Phone Line Surge Protection 1000 D gt E 20 O 0 oS Kp a d er SS ee ae D le Oe JE pte a D NEMA 6 IEC 4 1400 2000 IEC 4 NEMA 6 Installation and Operation Installing the UPS is as easy as following the steps shown Be aware of the Power Switch must be kept in the ON position otherwise the UPS will be disabled and your equipment will not be protected during a power failure 1 Inspection Remove the UPS from its packaging and inspect it for damage that may have occurred during shipping If any damage is discovered repack the unit and return it to the
7. ormal 14 45 Root 9 BLAN 9 ng gana Voltage 2170 Y Voltage 2170 Y a l Frequency 599 Hz 9300 Load 20 151 i 2 backup am AC LINE er ar a de m LOAD ON Model OFF LINE roma v roma v 8 Y Com Port COMI ed Standard 120 Y Temp 380 C ed Capacity 1000 2004 01 20 14 44 33 Agent Start gt I nstallation procedure 1 Goto the website http www ups software download com winpower htm 2 Choose the operation system you need and follow the instruction described on the website to download the software 3 When downloading all required files from the internet enter the serial No 511C1 01220 0100 478DFAA to install the software When your computer restarts the WinPower software will appear as a green plug icon located in the system tray near the clock Trouble Shooting Use the table below to solve minor UPS installation or operation problems If any abnormal situations occur that are not listed above please call service people immediately Symptom Possible Cause 1 Missing battery 1 Charge battery up to 10 hours 2 Battery defect 2 Replace with the same type of battery 3 When the Input cord 3 Press the power switch isn t electrified and again or electrify the Input Power switch is not cord Alarm buzzer Overload of the UPS Verify that the load matches beeps continuously the UPS capability specified in the specs failure back up load low more
8. place of purchase 2 Placement Install the UPS unit in any protected environment that provides adequate airflow around the unit and is free from excessive dust corrosive fumes and conductive contaminants Do not operate your UPS in an environment where the ambient temperature or humidity is high On the other hand place the UPS unit away from monitor at least 20cm to avoid interference 3 Charging This unit is shipped from the factory with its internal battery fully charged However some energy may be lost during shipping so the battery should be recharged before using it Plug the unit into an appropriate power supply and allow the UPS to charge fully by leaving it plugged in for 10 hours 10 hours 4 Computer Connection Connect one computer related device into each of the power receptacles supplied on the back of the UPS maximum of three devices ww i KA NANA NAN KAN AR AL AAA 5 Modem Phone line Connection Plug incoming internet line into the In socket at the back of the UPS Use one more Internet line cable and plug one end of the Internet line cable to the Out socket at the back of the UPS Plug the other end to the modem input socket as shown Incoming Internetline N TA b A SS Q Sul NG N 4 y 7 A 2 gt yy pl 2 A ya WP
9. put voltage will display 000 4 When in off charging mode it will display as below High Voltage Version Low Voltage Version i E Note the output voltage always is displayed as 000 in off charging mode 5 When in fault mode it will display as below FAULT character and the reason of fault only a os FAULT Note the fault code will be showed in fault mode 6 Load level definition Load LEVEL Load Bar I ndication 7 For 12V battery capacity definition Battery LEVEL Battery Bar I ndication Battery voltage lt 11V 11V lt Battery voltage lt 11 5V 11 5V lt Battery voltage lt 12 5V SLi Battery voltage gt 12 5V 7 For 24V battery capacity definition Battery LEVEL Battery Bar I ndication a Battery voltage lt 22V 23V lt Battery voltage lt 25V 2000 8 When over load the mark ST vill flicker every 1 second 9 When battery low the mark will flicker every 1 second Software I nstallation winPower Monitoring Software WinPower is a UPS monitoring software which provides user friendly interface to monitor and control your UPS This unique software provides safely auto shutdown for multi computer systems while power failure With this software users can monitor and control any UPS on the same LAN no matter how far from the UPS 2 WinPower Manager Ver 1 0 Iof xj System Logs UPS Tools Monitor Preference Language Help At JEMEK UPS Status UPS N