Home

Heath Zenith HEATH CB-2011 User's Manual

image

Contents

1. Heat or light from the lamps may be turning the Light Control on and off Re position the lamps away from the sensor Heat being reflected from other ob jects may be affecting the sensor Reposition sensor Light Control is in the Test mode and warming up Flashing is normal un der these conditions Turn Boost off Lights come Light Control may be installed in a relatively dark location Light Control is in Test Set control switch to an ON TIME position Light Control may be sensing small ani mals or automobile traffic re aim sensor Range is set too high Reduce Range setting on in daylight Lights flash on and off Lights come on for no apparent reason Lights flash once then stay off in Manual Mode TECHNICAL SERVICE Do Not Send Products If you experience a problem follow this guide You may also want to visit our Web site at www desatech com If the problem persists call for assistance at 1 800 858 8501 7 30 AM to 4 30 PM CST M F You may also write to DESA Specialty Products P O Box 90004 Bowling Green KY 42102 9004 ATTN Technical Service Specialty Products If contacting Technical Service please have the following information available Model Number Date of Purchase and Place of Purchase No Service Parts Available for this Product Sensor is detecting its own lights Re position lamps to keep area below the sensor relatively dark 1
2. Heati Zeniti Motion Sensor Light Control with Protective Lamp Shields Model CB 2011 Features e Turns on lighting when motion is detected e Automatically turns lighting off e Photocell keeps the lighting off during daylight hours This package includes Mounting Strap Lamp Holders Rubber Plug I Sensor Plastic Hanger Light Control N Mounting Bolt Gasket 2 Wire Connectors Bee awe 3 sizes included 7 2 PAR Lamps Requirements e The Light Control requires 120 volts AC e If you want to use the Manual Mode the control must be wired through a switch e Some codes require installation by a qualified electrician e This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations 2003 DESA Specialty Products OPERATION On Time Works 5 Sec 1 5 20 min Until Dawn resets to Auto Mode at dawn Day Night Test Auto Manual Note When first turned on wait about 1 2 minutes for the circuitry to calibrate TEST Put ON TIME switch on the sensor ON TIME bottom to TEST TEST 1 5 20 AUTO Put the ON TIME switch in the 1 5 ON TIME or 20 minute position TEST 1 5 20 MANUAL MODE Manual mode only works at night because daylight returns the sensor to AUTO
3. 5 YEAR LIMITED WARRANTY This is a Limited Warranty which gives you specific legal rights You may also have other rights which vary from state to state or province to province For a period of fifteen years from the date of purchase any malfunction caused by factory defective parts or workmanship will be corrected at no charge to you Light bulbs are not covered To obtain a refund or a replacement return the product to the place of purchase Not Covered Repair service adjustment and calibration due to misuse abuse or negligence light bulbs and other expendable items are not covered by this warranty Unauthorized service or modification of the product or of any furnished component will void this warranty in its entirety This warranty does notinclude reimbursementfor inconvenience installation setup time loss of use or unauthorized service This warranty covers only DESA Specialty Products assembled products and is not extended to other equipment and components that a customer uses in conjunction with our products THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY WARRANTY REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY PARTICULAR PURPOSE OR USE AND SPECIFICALLY IN LIEU OF ALL SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY ON THE PART OF DESA SPECIALTY PROD
4. UCTS FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS WHETHER OR NOT FORESEE ABLE Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Retain receipt for warranty claims 4 598 1111 01
5. as a 1 2 minute warm up period before it will detect motion When first turned onorwhen switching modes wait 1 2 minutes O Turnthe RANGE control to the mid position and the ON TIME control to the TEST position Bottom of Sensor Avoid aiming the sensor at Objects that change temperature rapidly such as heating vents and air conditioners These heat sources could cause false triggering Areas where pets or traffic may trigger the control Nearby large light colored objects reflecting light may trigger the shut off feature Do not point other lights at the sensor 240 8 ft 2 4 m 70 ft 100 ft 21m 30 5 m Boosted Maximum Range Maximum Coverage Angle The detector is less sensitive to motion directly towards it Sensor Least Sensitive Most Sensitive 598 1111 01 O Loosen the clamp screw in the sensor ball joint and gen amp z Screw tly rotate the sensor AD Walk through the coverage XN Ball area noting where you are Joint when the lights turn on Move the sensor head up down or sideways to change the coverage area Keep the sensor at least 1 2 5 cm Aim Sensor away from the lamps Down for Short J Adjust the RANGE as Coverage needed RANGE set too high may increase false triggering O Secure the sensor head s aim by tightening the clamp screw Do not over tighten the screw Aim Sensor Higher for Long Coverage O Set the amount of TIME you want the lights to s
6. iring The small end of the plastic hanger can be threaded through the hole in the center of the cover plate The small end then goes into one of the slots on the mounting strap O Route the Light Control s wires through the large gasket hole UU O Twistthe junction box wires and fixture wirestogether as shown Secure with wire connectors Mounting White to White Black to Bolt Set Junction box ground wire to green ground screw on fixture Mount THE LIGHT CONTROL O Align the Light Control cover plate and cover plate gasket Secure with the mounting bolt Push the Rubber Plug firmly into place Ifa wet location junction box was not used caulk the wall plate mounting surface with silicone weather sealant UU To avoid water damage and elec trical shock keep lamp holders below horizontal Keep lamps at least 1 2 5 cm from the PE sensor Do notallow the lamps to block Lens the lens Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180 from the factory setting When screwing in the floodilamps do not overtighten CAUTION To avoid fire or burn hazards keep fixture at least 2 51mm from combustible mate rials Do not aim at objects closer than 3 1m 598 1111 01 TEST AND ADJUSTMENT O Turn on the circuit breaker and light switch NOTE Sensor h
7. tay on after motion is detected 1 5 or 20 minutes SPECIFICATIONS Range Up to 70 ft 21 m 100 ft 30 5 m with Range Boost varies with surrounding temperature Sensing Angle Up to 240 Electrical Load Up to 300 Watts Maximum In candescent Up to 150 Watts Maximum each lamp holder Power Requirements 120 VAC 60 Hz Operating Modes TEST AUTO and MANUAL MODE Time Delay 1 5 20 minutes DESA Specialty Products reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold SYMPTOM Lights will not come on TROUBLESHOOTING GUIDE OSSIBLE CAUSE Light switch is turned off Flood light is loose or burned out Fuseis blown orcircuit breaker is turned off Daylight turnoff is in effect recheck after dark Incorrect circuit wiring if this is a new installation Lights stay on continu ously Aflood lamp is positioned too close to the sensor or pointed at nearby ob jects that cause heat to trigger the sensor Reposition the lamp away from the sensor or nearby objects Light Control is pointed toward a heat source like an air vent dryer vent or brightly painted heat reflective surface Re aim the sensor to cover desired Reposition sensor Reduce Range area Light Control is in Manual Mode Switch to Auto
8. we o Flip the light switch off for one second then back on to toggle between AUTO 1 Second OFF and MANUAL MODE oD Manual mode works only with the ON TIME switch in the 1 5 or 20 aL position 4 back on Mode Switching Summary Move ON TIME Switch to 1 5 or 20 minutes Flip light switch off for one second then back on MANUAL MODE If you get confused while switching modes turn the power off for one minute then back on After the calibration time the control will be in the AUTO mode 598 1111 01 INSTALLATION For easy installation select an existing light with a wall switch for replacement Wall Mount Eave Mount For under eave installation the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock For eave mount only Swingthe sensor head towards the clamp screw joint O Then rotate the sensor head clockwise 180 so the controls face down If the sensor pops out of the ball joint loosen the clamp screw and push the sensor back into the ball joint Tighten the clamp screw when done WIRE THE LIGHT CONTROL Turn power off at the fuse or circuit breaker Remove the existing light fixture Install the mounting strap as shown using two screws that fit your junction box The plastic hanger can be used to hold the fixture while w

Download Pdf Manuals

image

Related Search

Related Contents

型番 iCMP-FM3  C1-5シリーズ  NASGRO v6.1 Release Notes  KSB UMA 150 B  EXT: Shop System - Architektur macht Schule  ExtremeWare 7.3.2b3 - Installation and Release Notes  FAKOPP 3D  自動体外式除細動器(AED)使用報告書  Stop/Exit    

Copyright © All rights reserved.
Failed to retrieve file