FX3U-4HSX-ADP INSTALLATION MANUAL

image

Contents

1. follow the directions for usage Associated Manuals Manual name Description Explains FX3U Series PLC specification details for I O wiring installation and maintenance FX3U Series User s Manual Hardware Edition FX3G FX3U FX3UC Series Programming Manual Basic amp Applied Instruction Edition JY997D16501 MODEL CODE 09R516 JY997D16601 MODEL CODE 09R517 Describes PLC programming for basic applied instructions and devices How to obtain manuals For the necessary product manuals or documents consult with the Mitsubishi Electric dealer from where you purchase your product Applicable Standard FX3U 4HSX ADP complies with EC directive EMC Directive and UL standards UL cUL Further information can be found in the following manual FX3u Series Hardware Manual Manual No JY997D18801 Attention e This product is designed for use in industrial applications Note e Manufactured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporation Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany 1 Outline FX3U 4HSX ADP high speed input special adapter hereinafter called high speed input special adapter is a special adapter dedicated to FX3U Series PLC It retrieves pulse signals fro
2. so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Twist the end of strand wire and make sure that there are no loose wires Do not solder plate the electric wire ends Do not connect more than the specified number of wires or electric wires of unspecified size Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed 1 Wire size To connect to the desired unit use a shielded twisted pair cable having a conductor s of size AWG22 20 2 Applicable cable Type Wire size Single wire 0 3mm2 to 0 5mm AWG22 to 20 2 wire 2 pieces of 0 3mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve Manufacturer Caulking tool CRIMPFOXx 6 Phoenix Contact Co Ltd or CRIMPFOX 6T F 2 Al 0 5 8WH 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6 Strand wire single wire Stick terminal with insulating sleeve Insulation sleeve Contact area Crimp area tO 0 31 d zz Leen Leen 2 6mm 0 1 When using a stick term
3. Another equipment Q Another Q Q Independent grounding Best condition Shared grounding Good condition Common grounding Not allowed e The grounding wire size should be AWG 14 2 mm or larger e The grounding point should be close to the PLC and all grounding wire should be as short as possible This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when ins
4. JY997D16301C E JAPANESE S E ENGLISH Aa MITSUBISHI PROGRAMMABLE CONTROLLERS MELSEG F Side B Changes for the Better FX3U 4HSX ADP INSTALLATION MANUAL Manual Number JY997D16301 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective September 2010 Specifications are subject to change without notice 2005 Mitsubishi Electric Corporation F X 3u Safety Precaution Read these precautions before use This manual classify the safety precautions into two categories ODANGER and ZXCAUTION Indicates that incorrect handling may cause hazardous lt gt DANGER conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to
5. al gt FX3U Series User s Manual Hardware Edition Associated high speed counters C235 C236 C237 C241 C242 C244 C244 OP C245 3 C246 C247 C249 C251 C252 C254 C238 C239 C240 C243 C245 OP C248 X003 to X005 X007 5248 0P C250 C253 C253 OP C255 2 Use the terminal of the main unit for reset input if the second high speed input special adapter is not connected First unit X000 to X002 X006 Second unit 3 Use the terminal of the main unit for start input and reset input if the second high speed input special adapter is not connected Caution When connecting a high speed input special adapter same input numbers are allocated to the main unit and this special adapter Must use either one of the input terminals If both input terminals are used assumed action may not be executed because inputs of the high speed input special adapter and main unit are operated in an OR relationship to each other e Do not use wire the input terminal in main unit corresponding to the input number used in the high speed input special adapter e Do not use wire the input terminal in high speed input special adapter corresponding to the input number used in the main unit A 1 3 External Dimensions Part Names and Terminal Layout 4 5 6 9 10 8 7 O000000000 jM 11 9 Special adapter Terminal layout of 6 connector
6. an the following are equivalent to those of the PLC main unit FX3u Series User s Manual Hardware Edition Specification 500V AC for one minute Between input terminal of high speed input special adapter and ground SMQ or more by 500V terminal of PLC main unit DC megger 4 3 Power Supply Specification Item Dielectric withstand voltage Insulation resistance Specification Item Input circuit driving 30mA for 24V DC power supply Internally supplied from the main unit service power supply 30mA for 5V DC 5V DC power is supplied internally from the main unit Adapter driving power supply 4 4 Performance Specification Item Specification 4 points input polni Not counted among the total I O points of the PLC Input type Differential line receiver Equivalent to AM26C32 1 phase 1 input ee celine 1 phase 2 inputs High speed counter operated as hardware counter Maximum input frequency 2 phase 2 inputs 100kHz External cables of input area are insulated from PLC by photo Insulation coupler and transformer Wiring length Maximum 10m 32 9 1 The maximum input frequency for the software counter 2 will be the same as the maximum input frequency of when the main unit counts pulses via the input terminal For details on input frequency refer to the following manual FX3u Series User s Manual Hardware Edition 2 It also means the hardware counter is operated as a so
7. ath or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Associated Manuals Manual name Description FX3U Series JY997D16501 Explains FX3U Series PLC User s Manual MODEL specification details for I O wiring Hardware Edition CODE 09R516 installation and maintenance FX3G FX3U FX3UC Series Programming Manual Basic amp Applied Instruction Edition JY997D16601 Describes PLC programming for MODEL basic applied instructions and CODE 09R517 devices How to obtain manuals For the necessary product manuals or documents consult with the Mitsubishi Electric dealer from where you purchase your product Applicable Standard FX3U 4HSX ADP complies with EC directive EMC Directive and UL standards UL cUL Further information can be found in the following manual FX3u Series Hardware Manual Manual No JY997D18801 Attention e This product is designed for use in industrial applications Note e Manufactured by Mitsubishi Electric Corporation 2 7 3 Marunouchi Chiyoda ku Tokyo 100 8310 Japan e Manufactured at Mitsubishi Electric Corporation Himeji Works 840 Chiyoda machi Himeji Hyogo 670 8677 Japan e Authorized Representative in th
8. cover 2 or 5 is removed Input number Second unit Input LED 7 Input number First unit X000 Name X0 3 Unit mm inches Weight 80g 0 18 Ibs 1 DIN rail mounting groove DIN rail DIN46277 2 High speed I O special adapter connector cover Remove this cover for connecting high speed I O special adapter on the left side 3 Name plate 4 Special adapter slide lock Used to connect special adapter on left side of this special adapter 5 Special adapter connector cover Remove this cover for connecting special adapter on the left side 6 Terminal block for inputs European type Connects output signals of differential line driver type 7 Input LED red Lit when input turns ON if input turns ON and OFF alternately at high speed the LED flickers fast 8 POWER LED green Lit while power is properly supplied from main unit 9 Direct mounting hole 2 holes of 64 5 0 18 mounting screw M4 screw 10 Special adapter fixing hook 11 DIN rail mounting hook 12 Special adapter connector Used to connect the communication special adapter or analog special adapter to this adapter on left side 13 High speed I O special adapter connector Used to connect the high speed I O special adapter to this adapter on left side 2 Installation The product can be mounted on DIN rail DIN46227 or mounted directly using screws For installation uninstallat
9. e e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system a MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN
10. e European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany 1 Outline FX3U 4HSX ADP high speed input special adapter hereinafter called high speed input special adapter is a special adapter dedicated to FX3U Series PLC It retrieves pulse signals from a rotary encoder of which the output type is a differential line driver to a high speed counter or SPD instruction FNC 56 Up to two units of this high speed special adapter can be connected to the main unit per system For details on system configuration refer to the following manual FX3u Series User s Manual Hardware Edition 1 1 Incorporated Items Check if the following product and items are included in the package Product Accessories FX3U 4HSX ADP high speed input special adapter Installation manual 1 2 Input Allocation and Usable High Speed Counter Number When the power is turned on input numbers of the high speed input special adapters are allocated as shown in the table below in the order of unit position to the main unit See the table below for usable device number of associated high speed counter For details on high speed counters refer to the following manual FX3u Series User s Manual Hardware Edition Second unit First unit Analog Analog Analog High High High High special special special speed Space ee speed Mai i i f inpu outpu outpu Inpu ain unl function function funct
11. e version number can be checked by monitoring D8001 as the last three digits indicate it Note Cannot be connected to FX3UC Series PLC 4 2 General Specification For the general specification refer to the manual of the PLC main unit The items other than the following are equivalent to those of the PLC main unit FX3u Series User s Manual Hardware Edition Item Specification 500V AC for one minute Between input terminal of high speed input special adapter and ground SMQ or more by 500V terminal of PLC main unit DC megger 4 3 Power Supply Specification Dielectric withstand voltage Insulation resistance Item Input circuit driving 30mA for 24V DC power supply Internally supplied from the main unit service power supply 30mA for 5V DC 5V DC power is supplied internally from the main unit Specification Adapter driving power supply 4 4 Performance Specification Item Specification 4 points Input points Not counted among the total I O points of the PLC Input type Differential line receiver Equivalent to AM26C32 1 phase 1 input Maximum input f 200kHz High speed counter operated as 1 phase 2 inputs x frequency hardware counter 1 2 phase 2 inputs 100kHz External cables of input area are insulated from PLC by photo Insulation coupler and transformer Wiring length Maximum 10m 32 9 1 The maximum input frequency for the software counter 2 will be the same as
12. ftware counter For conditions of a hardware counter which operates as a software counter refer to the following manual FX3u Series User s Manual Hardware Edition 4 5 Connectable Device Caution The rotary encoder all of the following conditions Item Output type Output voltage connected to the input terminal of FX3U 4HSX ADP has to fulfill Specifications Differential line driver 5V DC or less 1 If the rotary encoder which fulfills the above stated conditions fails to operate please confirm specifications in advance 4 6 Internal Circuit of Input Interface For connection example and wiring refer to the following manual FX3u Series User s Manual Hardware Edition Rotary encoder etc Noninverting 4 output PASS a Pace az A B Z Ground resistance 1002 or less High speed input special adapter Equivalent to AM26C32 Grounding 1 X00D indicates input number of the high speed input special adapter 2 SG of the first unit and SG of the second unit are insulated from each other Grounding Grounding should be performed as stated below e The grounding resistance should be 1002 or less e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the following manual gt FX3U Series User s Manual Hardware Edition Another equipment
13. gh speed input special adapter corresponding to the input number used in the main unit A 1 3 External Dimensions Part Names and Terminal Layout 2 Installation The product can be mounted on DIN rail DIN46227 or mounted directly using 4 5 6 9 10 screws For installation uninstallation and safety precautions refer to the following manual 8 7 FX3uU Series User s Manual Hardware Edition INSTALLATION PRECAUTIONS DANGER AA e Make sure to cut off all phases of the power supply externally before EIRON attempting installation or wiring work A S Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS NCAUTION e Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur When drilling screw holes or wiring make sure that cutting and wiring debris do not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect the s
14. inal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25N m Do not tighten terminal screws with a torque exceeding the regulation torque Failure to do so may cause equipment failures or malfunctions 4 Specification STARTUP AND MAINTENANCE PRECAUTIONS CAUTION Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric distributor Do not drop the product or exert strong impact to it Doing so may cause damage DISPOSAL PRECAUTIONS Z CAUTION e Please contact a certified electronic waste disposal environmentally safe recycling and disposal of your device company for the TRANSPORT AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product 4 1 Applicable PLC Model name Applicability FX3U Series PLC Ver 2 20 from the first product and later The version number can be checked by monitoring D8001 as the last three digits indicate it Note Cannot be connected to FX3UC Series PLC 4 2 General Specification For the general specification refer to the manual of the PLC main unit The items other th
15. ion Special special special special adapter adapter adapter adapter adapter adapter adapter 1 Expansion board An expansion board is required to use any special adapters other than high speed I O special adapters For system configuration refer to the following manual gt FX3U Series User s Manual Hardware Edition Inputnumber Associated high speed counters D C235 C236 C237 C241 C242 2 C244 C244 OP First unit X000 to X002 X006 C236 ia j C245 3 C246 C247 C249 C251 C252 C254 Second C238 C239 C240 C243 C245 OP C248 unit X003 to X005 X007 5248 0P C250 C253 C253 OP C255 2 Use the terminal of the main unit for reset input if the second high speed input special adapter is not connected 3 Use the terminal of the main unit for start input and reset input if the second high speed input special adapter is not connected Caution When connecting a high speed input special adapter same input numbers are allocated to the main unit and this special adapter Must use either one of the input terminals If both input terminals are used assumed action may not be executed because inputs of the high speed input special adapter and main unit are operated in an OR relationship to each other e Do not use wire the input terminal in main unit corresponding to the input number used in the high speed input special adapter e Do not use wire the input terminal in hi
16. ion and safety precautions refer to the following manual FX3u Series User s Manual Hardware Edition INSTALLATION DANGER PRECAUTIONS e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product INSTALLATION PRECAUTIONS CAUTION Use the product within the generic environment specifications described in PLC main unit manual Hardware Edition Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur When drilling screw holes or wiring make sure that cutting and wiring debris do not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Do not touch the conductive parts of the product directly Doing so may cause device failures or malfunctions Connect the special adapter securely to their designated connectors Loose connections may cause malfunctions 2 1 Connection to the FX3U Series PLC e Refer to the procedure 2 for configuring a new system e Refer to the procedure 1 for adding product to an existing system Procedure 1 Turn off the power Disconnect all the cables c
17. ircuit or high voltage lines 2 Ground the shield wire or shield of the shielded cable at one point on the PLC However do not use common grounding with heavy electrical systems Make sure to properly wire to the European terminal board in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Twist the end of strand wire and make sure that there are no loose wires Do not solder plate the electric wire ends Do not connect more than the specified number of wires or electric wires of unspecified size Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed 1 Wire size To connect to the desired unit use a shielded twisted pair cable having a conductor s of size AWG22 20 2 Applicable cable Type Wire size Single wire 0 3mm to 0 5mm AWG22 to 20 2 wire 2 pieces of 0 3mm2 AWG22 3 Termination of cable end Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve Al 0 5 8WH 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6 Ma
18. l adapter e Install an expansion board when using a special adapter other than a high speed I O special adapter in combination with a high speed I O special adapter e Connect all the high speed I O special adapters before connecting other special adapters when they are used in combination Do not connect a high speed I O special adapter on the left side of an special adapters other than other high speed I O special adapters 3 Used cables and Tightening Torque on Terminal For connection example and wiring refer to the following manual FX3u Series User s Manual Hardware Edition WIRING PRECAUTIONS DANGER e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product PRECAUTIONS NCAUTION e When wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the main circuit line together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main c
19. m a rotary encoder of which the output type is a differential line driver to a high speed counter or SPD instruction FNC 56 Up to two units of this high speed special adapter can be connected to the main unit per system For details on system configuration refer to the following manual FX3u Series User s Manual Hardware Edition 1 1 Incorporated Items Check if the following product and items are included in the package Product FX3U 4HSX ADP high speed input special adapter Accessories Installation manual 1 2 Input Allocation and Usable High Speed Counter Number When the power is turned on input numbers of the high speed input special adapters are allocated as shown in the table below in the order of unit position to the main unit See the table below for usable device number of associated high speed counter For details on high speed counters refer to the following manual FX3u Series User s Manual Hardware Edition Second unit First unit High speed input special adapter High speed output special adapter High speed output special adapter High speed input special adapter Analog Analog Analog special special special function function function adapter adapter adapter Main unit Expansion board An expansion board is required to use any special adapters other than high speed I O special adapters For system configuration refer to the following manu
20. nufacturer Caulking tool CRIMPFOX 6 or CRIMPFOX 6T F 2 Phoenix Contact Co Ltd Strand wire single wire Stick terminal with insulating sleeve Insulation sleeve Contact area Crimp area dike td v 0 35 2 6mm 0 1 When using a stick terminal with insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions or otherwise the wire cannot be inserted easily The tightening torque must be 0 22 to 0 25N m Do not tighten terminal screws with a torque exceeding the regulation torque Failure to do so may cause equipment failures or malfunctions 4 Specification STARTUP AND MAINTENANCE CAUTION PRECAUTIONS Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric distributor Do not drop the product or exert strong impact to it Doing so may cause damage DISPOSAL EOE Z CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device TRANSPORT AND STORAGE PRECAUTIONS CAUTION e The product is a precision instrument During transportation avoid any impacts Failure to do so may cause failures in the product After transportation verify the operations of the product 4 1 Applicable PLC Model name Applicability FX3U Series PLC Ver 2 20 from the first product and later Th
21. onnected to the PLC main unit and special adapter Dismount the main unit and special adapter mounted on DIN rail or mounted directly using screws 2 Install an expansion board to the main unit For installation of expansion board refer to the following manual FX3u Series User s Manual Hardware Edition 3 Remove the high speed I O special adapter connector cover Right fig A and the special adapter connector cover Right fig B on the main unit In case of connecting this product to a high speed I O special adapter as an addition please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace the following procedures similarly 4 Slide the special adapter slide lock Right fig C of the main unit 5 Connect the high speed I O special adapter Right fig D to the main unit as shown on the right 6 Slide back the special adapter slide lock Right fig C of the main unit to fix the high speed I O special adapter Right fig C Connection precautions e Install the expansion board to be used before connecting a special adapter e Install an expansion board when using a special adapter other than a high speed I O special adapter in combination with a high speed I O special adapter e Connect all the high speed I O special adapters before connecting other special adapters when they are used in combination Do not connect a high s
22. pecial adapter securely to their designated connectors Loose connections may cause malfunctions fecos000000 00000000 11 9 Special adapter Terminal layout of 6 connector cover 2 or 5 is removed Input number First Second unit unit X000 X003 Input LED 7 2 1 Connection to the FX3u Series PLC e Refer to the procedure 2 for configuring a new system e Refer to the procedure 1 for adding product to an existing system Procedure 1 Turn off the power Disconnect all the cables connected to the PLC main unit and special adapter Dismount the main unit and special adapter mounted on DIN rail or mounted directly using screws 2 Install an expansion board to the main unit For installation of expansion board refer to the following manual FX3u Series User s Manual Hardware Edition 3 Remove the high speed I O special adapter connector cover Right fig A and the special Input number Unit mm inches Weight 80g 0 18 Ibs 1 DIN rail mounting groove DIN rail DIN46277 2 High speed I O special adapter connector cover adapter connector cover Right fig B on the Remove this cover for connecting high speed I O special adapter on the left side main unit 3 Name plate In case of connecting this product to a high 4 Special adapter slide lock speed I O special adapter as an addition Used to connec
23. peed I O special adapter on the left side of an special adapters other than other high speed I O special adapters 3 Used cables and Tightening Torque on Terminal For connection example and wiring refer to the following manual FX3u Series User s Manual Hardware Edition WIRING PRECAUTIONS lt SDANGER e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product WIRING PRECAUTIONS CAUTION e When wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the main circuit line together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100mm 3 94 or more away from the main circuit or high voltage lines 2 Ground the shield wire or shield of the shielded cable at one point on the PLC However do not use common grounding with heavy electrical systems Make sure to properly wire to the European terminal board in accordance with the following precautions Failure to do
24. s e Independent grounding should be performed for best results When independent grounding is not performed perform shared grounding of the following figure For details refer to the following manual FX3U Series User s Manual Hardware Edition Q Another Another equipment equipment Q Q Independent grounding Shared grounding Common grounding Best condition Good condition Not allowed e The grounding wire size should be AWG 14 2 mm or larger e The grounding point should be close to the PLC and all grounding wire should be as short as possible This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human lif
25. t special adapter on left side of this special adapter please replace the main unit in the above description with a special adapter and perform the procedure as indicated Please replace the following procedures similarly 4 Slide the special adapter slide lock Right fig C of the main unit 5 Special adapter connector cover Remove this cover for connecting special adapter on the left side 6 Terminal block for inputs European type Connects output signals of differential line driver type 7 Input LED red Lit when input turns ON if input turns ON and OFF alternately at high speed the LED flickers fast 8 POWER LED green Lit while power is properly supplied from main unit 9 Direct mounting hole 2 holes of 64 5 0 18 mounting screw M4 screw 5 Connect the high speed I O special adapter Right fig D to the main unit as 10 Special adapter fixing hook shown on the right 11 DIN rail mounting hook 6 Slide back the 12 Special adapter connector special adapter Used to connect the communication special adapter or analog special adapter to slide lock Right this adapter on left side fig C of the main unit to fix the high speed I O special adapter Right fig C 13 High speed I O special adapter connector Used to connect the high speed I O special adapter to this adapter on left side Connection precautions e Install the expansion board to be used before connecting a specia
26. talling the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system ata MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN HIMEJI WORKS 840 CHIYODA CHO HIMEJI JAPAN side JY997D16301C B E A JAPANESE B ENGLISH ate MITSUBISHI crores ror tne Better PROGRAMMABLE CONTROLLERS MELSEGIP FX3U 4HSX ADP INSTALLATION MANUAL F 2 This manual describes the part names dimensions mounting and specifications of the product Before use read this manual and manuals of relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions And store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the end user Registration The company name and the product name to be described in this manual are the registered trademarks or trademarks of each company Effective September 2010 Specifications are subject to change without notice 2005 Mitsubishi Electric Corporation Safety Precaution Read these precautions before use This manual classify the safety precautions into two categories KODANGER and XCAUTION Indicates that incorrect handling may cause hazardous DANGER conditions resulting in de
27. the maximum input frequency of when the main unit counts pulses via the input terminal For details on input frequency refer to the following manual FX3u Series User s Manual Hardware Edition 2 It also means the hardware counter is operated as a software counter For conditions of a hardware counter which operates as a software counter refer to the following manual FX3u Series User s Manual Hardware Edition 4 5 Connectable Device Caution The rotary encoder connected to the input terminal of FX3U 4HSX ADP has to fulfill all of the following conditions Item Specifications Output type Differential line driver Output voltage 5V DC or less 14 If the rotary encoder which fulfills the above stated conditions fails to operate please confirm specifications in advance 4 6 Internal Circuit of Input Interface For connection example and wiring refer to the following manual FX3u Series User s Manual Hardware Edition Rotary encoder etc High speed input special adapter V Noninverting E ea a e output i gt ren HX XX Q A Inverting output BaS Q OV Equivalent to AM26C32 Grounding Ground resistance 1002 or less X00D indicates input number of the high speed input special adapter 2 SG of the first unit and SG of the second unit are insulated from each other Grounding Grounding should be performed as stated below e The grounding resistance should be 1002 or les