Home
mtc2092a0601h
Contents
1. variety of process connections The process connection on the tank and its opening should be arranged so that the float can be inserted Should it not be possible the float should be removed from the sensor shaft After suggested opening inserting the shaft the float should be pulled onto the guide tube inside the vessel The word UP etched on the float is to ensure mounting the float in correct position To complete procedure the retaining pin should be inserted into its hole and legs bent Note before installation it is advisable to perform a preliminary operational check similar to the procedure described in the Calibration section 4 WIRING After unscrewing and removing the housing cover from the unit the cable should be pulled through the conduit opening The unit contains CMOS components which can be damaged by static electricity Therefore the shielding of the cable should be connected to the ground screw first After the shield is grounded the wire and wire of the terminal J1 should be connected Is the shield also grounded at the power supply an equaliser cable should be applied between the two ground screws liquid end positioner Terminal J1 gt ag 5 SETUP PROCEDURE CALIBRATION After power up the unit is fully operational Factory Setting Operation mode in accordance with the order normal or reverse Range maximum or in accordance with the order Damping 1s
2. Operating mode selection Jumper J1 Direction of the output change assigned to the level change can be the same or reversed Note Jumper J1 is factory set It must not be changed in the field Normal operation Reverse operation 2 6 2 6 JP1 position S 1 5 1 5 Low level 4 mA 20 mA High level 20 mA 4 mA Local current meter Jumper JP2 Jumper JP2 allows for the connection of an auxiliary current meter Move Jumper JP2 from pins 1 2 to pins 2 3 3 2 1 p CO Dm O The yellow LED will illuminate indicating possibility of the measurement Connect the meter J4 positive and J5 negative and the LED will go out Move the Jumper JP2 back to pins 1 2 after measuring the current Calibration Normal operating mode Move the float to the desired top position for the 20 mA output Adjust SPAN clockwise to increase and counter clockwise to decrease the output to 20 mA 0 01 mA Move the float to the desired bottom position for the 4 mA output Adjust ZERO clockwise to increase and counter clockwise to decrease the output to 4 mA 0 01 mA Repeat steps 1 and 2 several times until the outputs at the set points remain 0 01 mA Reverse operating mode It is the same procedure as with the normal operation The only difference is that the 4 mA in the top position should be set by the potentiometer SPAN and that the 20 mA in the bottom position should be set by the potentiometer ZERO Adjustment of damp
3. Thank you for choosing a NIVELCO instrument We are sure that you will be satisfied with it throughout its use NIVYOTRACK MAGNETOSTRICTIVE TRANSMITTERS 1 APPLICATION NIVOTRACK MTL1 2 series float type magnetosrictive level transmitter is a two wire precision measuring instrument for clean liquids both in normal and hazardous location These instruments re quire minimum maintenance since the float is the only moving part 2 TECHNICAL DATA Insertion length L 0 5m 3 7 m according to the Order Codes maximum up to the bumping point of the float Range minimum 0 6 x Insertion length Zero offset maximum 0 4 x Insertion length Process pressure maximum 2 5 MPa 25 bar for steel floats 0 3 MPa 3 bar 20 C for plastic floats Medium density min 0 7 g cm with float 52mm min 0 5 g cm 95mm Medium temperature PP 20 C 80 C PVDF 20 C 130 C Ex 40 C 70 C 40 C 130 C Ambient temperature 40 C 70 C Float size material 52x59 mm 1 4571 95 mm 1 4571 76x87 mm PP or PVDF Material of wetted parts Stainless steel 1 4571 DIN PP or PVDF float see Order Codes Output Normal operation 4 mA bottom 20 mA top Reverse operation 20 mA bottom 4 mA top on special request Accuracy 0 04 or 1mm Linearity 0 035 or 0 8mm Repeatability 0 01 or 0 4mm Maximum load resistance Rr Ur 10 5 V 0 02A Ut powe
4. at 76mm flange PP PVDF cylindrical float 76mm fl A838 PVDF PP cylindrical float 76mm flange PP Ex PVDF cylindrical float 76mm flange PP Ex PVDF Cylindr float 76mm fl A38 PVDF Ex O o 2 to Note 1 Reverse operation on request 20 4 mA 2 Not all code variations can be selected 3 INSTALLATION The NIVOTRACK MTO 2 should be located in an area which allows easy access for service calibration and monitoring Accuracy of the measurement will be affected by waves on the surface or excessive wk i vibration Therefore the instrument should be located away from the inlet and outlet as far as possible The process fluid should be free of any 2 3 DIMENSIONS OD VZ S r RX Cl cL O m o a as gt ao A a kk Ambient temperature 70 130 C Medium temperature suspended solids or material that could stick between the float and the guide rod If used at temperatures in exess of 70 C the maximum ambient temperature allowed will be in accordance with the derating diagram range f insertion length 5 3 7 mM insertion length I IC 0 5 3 7 m inactive max meas inactive max meas 05 Benyulasi hossz 0 5 3 7 m track db i i According to the order code The unit should be protected against heat radiation NIVOTRACK MT_ 2 series is offered with a
5. ing Jumper JP3 Jumper JP3 allows for the adjustment of the damping time This jumper is factory set between pins 1 2 for 1 second Damping 1s 5s JP3 position ZERO SPAN JP3 JP1 5 1 POWER SUPPLY FOR EX PROOF UNITS The unit can be connected to a current loop with duly certified EEx ia IIB power supply and with technical data according to the Technical Data mumn Ex Ex 5 aal 230v ac Umax 28 4 V DC max 99 MA Pmax 0 67 W C 150 nF Ly 4 2mH 6 MAINTENANCCE AND REPAIR The unit does not require routine maintenance however the shaft may need occasional cleaning to remove surface deposits Repairs will be performed at the manufacturer premises Units returned for repair should be cleaned or desinfected by the customer 7 STORAGE CONDITIONS Ambient temperature 30 C 60 C Relative humidity max 98 8 WARRANTY Nivelco provide a warranty for the period of 2 two years Repairs under warranty are performed at the Manufacturer s premises costs of dismantling reinstalling or shipping are borne by the Customer Claims for guarantee are not valid in respect of failures due to abnormal usage breakage disaster or incompetent installation or usage mtc2092a0601h 2002 01 02 Technical specification may be changed without notice
6. r supply voltage Maximum output Fault indication value 24mA Damping 1 sec 5 sec adjustable Supply voltage 10 5 36 VDC Ex protection Ex power supply EEx ia IIB T5 Umax 28 4 V DC Imax 99 MA Pmax 0 67 Watt Electric protection Ingress Protection Ill Protection Class IP 67 Process connection According to the order codes Electric connection 2xPg 16 and2x o NPT thread shielded cable 0 75 1 5 mm Enclosure Powder paint coated aluminium Mass 2 1 ACCESSORIES User s Manual Warranty sheet 2 x Pg 16 cable gland 2 2 kg guiding tube 0 35 kg m See derating diagram under 3 2 2 ORDER CODES NIVOTRACK Modei Process connection USER S MANUAL Manufacturer Nivelco Process Control Co H 1043 Budapest Dugonics u 11 Telephone 36 1 369 7575 Fax 36 1 369 8585 E mail sales nivelco com http www nivelco com Version Ex aman lenrth Om 0 1m 1 2m 2 3m 3 Sealing ring for connection with BSP thread only klingerit a my 2 BSP 1 4571 1 NPT 1 4571 1 fy NPT 1 4571 2 NPT 1 4571 1 BSP sliding sleev 1 1 2 BSP sleeve 2 BSP sleeve 1 NPT sleeve 1 1 2 NPT sleeve 2 NPT sleeve DN 80 DN 100 Steel ball float 95mm Steel cylindrical float 52mm Steel ball float 95mm Ex Steel cylindrical float 52mm Ex PP cylindrical float 76mm flange PP PVDF cylindrical flo