Home
Mammography Film Digitizer User's Manual
Contents
1. MICROTEK h ed i 5000 Mammography Film Digitizer User s Manual Preface Copyright 2013 Microtek International Inc all rights reserved This document may not be reproduced or copied in any way stored electronically or translated into any language without the permission of Microtek International Inc Trademarks Microtek ScanMaker ArtixScan ScanWizard and ColoRescue are trademarks or registered trademarks of Microtek International Inc All other trademarks or registered trademarks are the property of their respective holders Specifications software and hardware bundles are subject to change without notice Not responsible for typographical errors Disclaimer The contents of this manual have been checked carefully for accuracy and every effort has been made to ensure that there are no errors However Microtek makes no guarantee as to the accuracy of the contents of this document and reserves the right to make changes to the contents without prior warning 149 004788 B September 2013 Microtek International Inc No 6 Industry East Road 3 Science Based Industrial Park Hsinchu 30077 Taiwan EVESTAR GmbH D 47877 Willich Germany Microtek International Inc 6 Industry East Road 3 Science Based Industrial Park Hsinchu 30077 Taiwan Tel 886 3 5772155 Fax 886 3 5772598 http www microtek com 2 Medi 5000 User s Manual FCC Compliance Statement This equipment Model MMS 6400MU2
2. Moving and Storing the Film Digitizer A e Always ensure that the digitizer is stored properly before shipping or moving it Quick stops excessive force and uneven surfaces may cause the product to overturn when moving A A e Do not hit or drop the digitizer The digitizer may be damaged if it receives a strong jolt which may result in fire or electric shock if the digitizer is used without being repaired A A e Do not place the digitizer on any slippery slanted or unstable surface The product may slide or fall causing serious injury to people as well as serious damage to the product Medi 5000 User s Manual 7 A AN e Do not use the digitizer near water Never spill liquid of any kinds on the product or it may result in electric shock or other hazards A e This digitizer should be situated away from heat sources such as radiators heat registers stoves or other products including amplifiers that produce heat A e Do not store the digitizer in which it may be exposed to direct sunlight Using the Digitizer gt e Before using the digitizer make sure the area of the glass surface is clear from obstacles The digitizer is only designed and used for digitizing mammography films or reflective materials Do not attend to use it for other purposes gt Maintenance and Service e When the digitizer is going to be cleaned ensure to turn off the power of each device and unplug the power cable from the AC outle
3. Legal Signature Hsinchu Taiwan 02 11 2011 Place Date 6 Medi 5000 User s Manual Safety Precautions Before using your digitizer read the following safety guides carefully which detail the proper operation of the digitizer and its accessories to prevent injuries or damage to users or equipment Meanings of Symbol Signs This indicates hazardous situation which if not payed CAUTION attention could result injury or damage to users or equipment J WARNING This indicates hazardous situation which if not payed attention could result serious injury or death to users Power Supply N Use a power source only with a power rating specified on the marking label A AN e Ensure to turn off the power of each device before connecting or disconnecting the cables AA A AX Insert the plug completely into the outlet as a loose connection may cause arcing and result in fire Ensure to hold the plug or connector to disconnect the cable otherwise if you pull the cable only it may damage the core wire and result in fire or electric shock A e Place and route the power supply cord such that it is not likely to be walked on or pinched by items placed upon or against them paying particular attention to the cord near the power plugs convenience receptacles and at the point where it exits from the outlet A e When the digitizer is left unattended and unused for long periods of time unplug it from the wall outlet
4. MHz and 80 dB from 80 MHz Applicable to 100 MHz The minimum at 20 MHz is 100 dB and the minimum at 80 MHz is 80 dB The ME system when installed in such a shielded location is suitable for use in all establishments other than domestic and those directly connected to the public low voltage es power supply network that supplies buildings used for domestic purposes Medi 5000 User s Manual 5 CE Declaration of Conformity CE DoC Microtek International Inc 7 6 Industry East Road 3 Tel 886 3 5772155 Mi R TER Science Based Industry Park Fax 886 3 5772598 Hsinchu Taiwan 30077 R O C DECLARATION OF CONFORMITY DoC Supplier Name Microtek International Inc Address No 6 Industry East Road 3 Science Based Industrial Park Hsinchu Taiwan 30077 R O C Declares that Type of Equipment Medical Image Digitizer Model Number MMS 6400MU2L Complies with following Standard Directive EN60601 1 1990 A1 1993 A2 1995 93 42 EEC EN 60601 1 2 2007 93 42 EEC Emissions EN55011 2007 A2 2007 Group 1 Class B EN 61000 3 2 2006 A2 2009 Class A EN 61000 3 3 2008 Immunity IEC 61000 4 2 Ed 2 0 2008 IEC 61000 4 3 Ed 3 2 2010 IEC 61000 4 4 Ed 2 1 2010 IEC 61000 4 5 Ed 2 0 2005 IEC 61000 4 6 Ed 3 0 2008 IEC 61000 4 8 Ed 2 0 2009 IEC 61000 4 11 Ed 2 0 2004 Declared by Derek Tang Name Surname R amp D center Vice President Position Title Da ek ET A
5. auto crop the scan frames perform scanning in a single pass for multiple films at one time and save the scanned images into your selected folder or send them to your selected application By the help of this method the busy medical professionals or staffs can save time to convert X ray films into digital files effortlessly e One pass Scan for Multiple Jobs This feature allows the digitizer to perform scanning in a single pass for all the selected scan jobs e Energy saving LED light source Adopting LEDs as the light source when the scanner is detected by the system there are no requirements for any warm up time before carrying out the scan which boots your productivity and reduces energy costs amazingly With its stable performance the image quality will remain consistent even after used for a certain period of time e Premium Image Quality With a high resolution of 3200 dpi the 16 bit grayscale and a high dynamic range of 4 5 maximum optical density the Medi 5000 is able to capture a wide range of gray tones providing excellent details when digitizing mammography images e Exclusive Mammography Film Holders These specially designed mammography film holders are used to hold mammography films in place By loading mammography film holders on the scan bed before scanning film you can ensure perfect alignment of your mammography images and achieve consistent scans The Medi 5000 provides two types of mammography film holders
6. for scanning 18 x 24 cm and 24 x 30 cm mammography films e 12 x17 scan bed The flatbed of the Medi 5000 lets you easily digitize various sizes of X ray films up to 12 x16 and reflectives up to 12 x 17 which offers more flexibility for storing old X ray films or records e Smart Touch button A Smart Touch button Scan locating at the front panel of the scanner provides you a quick and easy way to capture images that can be automatically saved as files or sent to another application for further processing later Medi 5000 User s Manual 13 Microtek ScanWizard Medi software The friendly user interface of ScanWizard Medi stores X ray images in a computer readable format offering an easy and quick access and management Easy to operate clean and maintain The Medi 5000 requires virtually no routine maintenance and no daily cleaning which is ideal for busy radiology departments System Requirements In order to use your Medi 5000 your computer must satisfy the following system requirements CD ROM drive for installing software Color display with 24 bit color output capability 512 MB RAM or above Pentium IV PC or higher with Hi Speed USB USB 2 0 Microsoft Windows XP Vista or Windows 7 14 Medi 5000 User s Manual Unpacking Your Film Digitizer Looking for Damage While unpacking your digitizer inspect the shipping carton for any signs of mishandling or damage The digitizer s packing
7. panel or the Scan button on the Medi 5000 unit to scan the image e If ScanWizard Medi is launched as a stand alone program the scanned image can be saved after the scan to a file opened in an image editing program or sent to a printer e If ScanWizard Medi is launched as a plug In from an image editing program the scanned image is delivered after the scan to your application where the image can be saved printed or modified further Type Gray Scale 12 bit 7 Resolution 600 Scan Frame x Scaling Output P ill wi 8 52 l mo m k Image Size 8 52 N 49 220 KB D M Sampling QO None gt White Black Pts Tone Curve Brt Contrast a Filter q Descreen No Correction v E No Correction No Correction None 9 None ll E 8 Automatic Color Restoration Reset ah MICROTEK ScanMaker s450 Material MICROTEK selecting press CTRL key to keep aspect ratio selection or press SHIFT key to add new job Medi 5000 User s Manual 39 Care and Cleaning To ensure optimal performance for the Medi 5000 it is important to clean the glass surface of the digitizer on a regular basis Cleaning the Glass Surface 1 Lift up the TMA of the digitizer 2 Use the cleaning cloth come with your package or a soft non abrasive and lint free cloth to gently wipe the glass surface area
8. software on the Medi 5000 CD click each software program in the order that it appears on the screen to install and follow the on screen instructions 5 Click EXIT on the Microtek Software Installer screen when all the software has been installed 6 Restart your computer Drivers amp Software Upgrades After you finish the installation of software if you found that the installed drivers and software cannot run your product or your computer system properly later please go to the Microtek Download Service site at ww7 microtek com tw service php to download and install any updates you may require For additional information about Microtek products please visit our website at www microtek com Medi 5000 User s Manual 23 Unlocking the Digitizer 1 Remove the yellow Unlock sticker from your digitizer 2 With the digitizer power off turn the digitizer on its side and locate the locking screw at the bottom of the digitizer 3 Using a screwdriver push and turn LA the locking screw counterclockwise to the unlock position W When successfully unlocked the unigcked screw will push out a little protruding slightly from the bottom of the digitizer NOTE To lock the digitizer for shipping and other purposes follow the steps below 1 Turn off the digitizer 2 Turn the digitizer back on When the indicators on the front of your digitizer stop blinking use a screwdriver an
9. the TMA has been properly installed with its connector securely connected to the scanner s 15 pin accessory port If not plug the connector of the TMA into the digitizer s 15 pin accessory port To the Power Cord 1 Connect the power adapter to the back of the digitizer 2 Plug one end of the power cord into a wall outlet or other power source To the Hi Speed USB Cable 3 Connect one end of the Hi Speed USB cable to your computer 4 Connect the other end of the Hi Speed cable to the digitizer s USB port Medi 5000 User s Manual 27 5 Turn the Power switch on the back of the digitizer to On and wait for the lights to stop blinking and stay on steady The digitizer will be detected by your system automatically 28 Medi 5000 User s Manual Digitizing Mammography Films To scan Mammography film use the holders included with your package There are two types of holders 18 x 24 cm Film Holder and 24 x 30 cm Film Holder Use the holder that correctly matches the film size to be scanned The use of the individual Mammography film holder is explained in the succeeding pages of the manual Positioning Mammography Films A Using the 18 x 24 cm Film Holder To scan 18 x 24 cm Mammography film use the 18 x 24 cm Film Holder which can hold up to two 18 x 24 cm Mammography films at atime 1 Place 18 x 24 cm Mammography Film Holder on the digitizer glass surface Make sure to orient the
10. 18 Medi 5000 User s Manual How to Repack Your Film Digitizer for Shipping To ship back your Medi 5000 for repairing maintenance services or other reasons in order to not damage your Medi 5000 it is strongly recommended that using the original carton and other packing materials Follow the steps below to repack your Medi 5000 correctly 1 Wrap the digitizer with the plastic bag and then insert it into one foam support 2 Cover down the other foam support on r r 3 With both hands hold the two sides of foam supports firmly and then insert them into the shipping carton four sides of the carton 4 Put the cardboard each by each back into A 5 Medi 5000 User s Manual 19 5 Put the accessary bags inside the two cardboards on each side of the carton Then put back the bag containing the film templates on the top of the digitizer 6 Put back two cardboards on the top of the shipping carton and finally close the top cover of the shipping carton and seal it with tape 20 Mbedi 5000 User s Manual Taking a Closer Look Front Open View E V No Names of Parts Functions of Parts 1 Locking Unlocking screw Used to lock and unlock the TMA 2 TMA Transparent Media Adapter is used to scan X ray films 3 Glass Surface Scan bed for scanning X ray films or reflectives 4 Vertical Ruler Used to measure the length of the images 5 Smart Touc
11. L has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures e Reorient or relocate the receiving antenna e _ Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help Note A shielded Hi Speed USB interface cable with ferrite core installed on the film digitizer connector end must be used with this equipment Caution Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two con
12. an the width of the digitizer glass surface align the film against the top corners left and right of the U shaped ruler located at the front of the digitizer When placing the film make sure that the Calibration window on the digitizer glass surface is kept clear and free of obstruction at all times If the width of the film is smaller than the width of the digitizer glass surface do not align the film against the U shaped ruler located at the front of the digitizer When placing the film make sure that the Calibration strip on the digitizer glass surface is kept clear and free of obstruction at all times Medi 5000 User s Manual 35 2 Follow the procedures steps 2 through 6 for Scanning Mammography Films to launch the ScanWizard Medi software and to specify your scanning requirements 3 Click the Smart Scan button on the control panel or the Scan button on the Medi 5000 unit to start scanning If you do not use a supplied Microtek Scan Wizard Medi Smart holder then start the scanning process when the overview is Image preview is complete Continue to scan si ae H i If YES adjust scan settings in the interface right now After done finished ScanWizard Medi will Grass S E acai prompt you a window to ask if If NO press Cancel button to redo image preview you want to continue the Back i scanning You can select the Scan Frame tool from the Toolbar in the Preview windo
13. anned image is delivered after the scan to your application where the image can be saved viewed or printed further Medi 5000 User s Manual 33 Microtek ScanWizard Medi Scan To Save As Save in My Images e Image001 tif Image002 tif Ti Image tif 7 Frame Magnify Pan Material File name Image003 Save Save as type Tagged Image File Format tif zi Cancel Auto suffix serial numbers to the given root filename File Option I Save multiple images as a single file I Send image to application after saving E Adobe Photoshop QO Scan Job Untitled2 gt O E Gray Scale 12 bit v Q resoiution jeo Scan Frame x Scaling Output wi 9 32 J32 mD o Image Size 34 517 KB M Sampling Q While Reset ath MICROTEK era selecting press CTRL key to keep aspect ratio selection or press SHIFT key to add new job After scan After scan 34 Medi 5000 User s Manual Digitizing X ray Films without Film Holder If the supplied film holder is not going to be used the Medi 5000 also allows you to scan various sizes of X ray films up to 12 x 16 1 Place the X ray film to be scanned on the digitizer glass surface Proper positioning of the film on the digitizer is important for getting a correct image Incorrect positioning of film will result in an incorrect image e If the width of the film is larger th
14. carton and padding material have been carefully chosen to prevent damage to the unit in shipping and can withstand a reasonable amount of pressure After unpacking your digitizer package refer to the later section to ensure that you received all of the parts necessary for digitizer setup If there are any damaged or missing parts notify the shipper immediately or contact customer service NOTE Save the carton and all packing materials If you need to ship the digitizer later it is recommended that you should repack it using the original wire ties plastic bags foam supports and cartons which protects your digitizer from unnecessary damage Refer to the later section How to Repack Your Film Digitizer for Shipping for the detail Unpacking Package Contents After unpacking the shipping carton follow the steps shown below to take out your digitizer and other accessory components 1 Ensure that you put your shipping carton toward the right direction Then open the top cover 2 Remove two cardboards from the top of the shipping carton 3 Take out the bag containing the film templates on the top of the digitizer Then take out two accessory bags from the insides of two cardboards on each side of the carton Medi 5000 User s Manual 15 4 Remove each cardboard from four sides of the carton 5 With both hands hold and lift up two sides of the foam supports firmly Before putting down the package on a stea
15. d then push and turn the locking screw clockwise to the locked position SS When the screw has been tightened this indicates that your v digitizer is locked 3 Turn off your digitizer Locked 24 Medi 5000 User s Manual Installing the TMA 1 Attach the TMA by sliding the posts at the rear of the TMA into the holes 2 Plug the connector of the TMA into the digitizer s 15 pin accessory port Medi 5000 User s Manual 25 3 Unlock the TMA a b c Remove the yellow Unlock sticker from the TMA Look for the locking knob at the base of the TMA Turn the locking knob counterclockwise to the unlock position fp Unlocked NOTE To lock the TMA for shipping and other purposes follow the steps below a b c d Make sure the TMA is connected to the digitizer then turn off the digitizer if your digitizer is on Turn the digitizer back on The TMA s carriage will move to the standby position in a few moments When the indicators on the front of your TMA and digitizer stop blinking turn the locking knob clockwise on to the lock position f Turn off your digitizer and disconnect the TMA connector from the digitizer The TMA is ready for transport Locked 26 Medi 5000 User s Manual Connecting the Digitizer Before connecting the Medi 5000 with your computer make sure that
16. d to your computer and plugged into a power source 2 The Add Remove Hardware Wizard appears on your screen Click the Cancel button and close the ScanWizard Medi Disconnect the Hi Speed USB cable from the back of your computer and refer to the installation instructions in this document 3 When trying to scan an error message appears on your screen that reads Can t Find Scanners Make sure your digitizer is unlocked see Step 3 and 4 in the Initial Setup section Make sure your digitizer is connected to your computer and plugged in to a power source see Step 5 in the Initial Setup section Uninstall and reinstall the ScanWizard Medi software 4 After clicking scan a blank screen appears Make sure your digitizer is unlocked see Step 3 and 4 in the Initial Setup section Uninstall and reinstall the ScanWizard Medi software 42 Medi 5000 User s Manual Having trouble scanning X ray films Make sure the TMA Transparency Media Adapter is properly installed with its connector securely connected to the digitizer s 15 pin accessory port Make sure you place the film holder with the loaded film properly on the scan bed Do not block the calibration area as indicated in the Positioning Mammography Films section Make sure you are in the X Ray scanning mode If not click the Scan Material icon in the Preview window then select X Ray as your scanning mo
17. de Uninstall and reinstall the ScanWizard Medi software Having trouble scanning reflective originals Make sure you place the reflective original to be scanned properly on the scan bed Make sure you are in the Reflective scanning mode If not click the Scan Material icon in the Preview window then select Reflective as your scanning mode Uninstall and reinstall the ScanWizard Medi software Medi 5000 User s Manual 43 Specifications Type Image Sensor Light Source Scanning Modes Resolution Dynamic Range Scanning Area Product Life Cycle Interfaces Dimensions L x W x H Weight Voltage Power Consumption Environment Important Desktop flatbed film digitizer CCD Charge Coupled Device LED Grayscale in a single scanning pass Input 16 bit grayscale Approx 65 536 shades of gray 8 bit grayscale Approx 256 shades of gray Output 16 bit grayscale Approx 65 536 shades of gray 12 bit grayscale Approx 4 096 shades of gray 8 bit grayscale Approx 256 shades of gray Optical 3200 dpi H x 6400 dpi V 4 5 Dmax Max Transparent 12 x 16 305 mm x 406 mm Reflective 12 x 17 305 mm x 432 mm 100 000 scans or 5 years Hi Speed USB USB 2 0 24 7 x 14 7 x 7 1 627 5 x 375 9 x 180 5 mm 35 4 Ibs 16 1 kg AC 100V to 240V 47 63 Hz 1 5A Max Input 54 9 W Max Operating temperature 50 to 104 F 10 to 40 C Relative
18. ditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Medi 5000 User s Manual 3 CE CE 0120 Compliant Device 0120 CE CE Compliance Statement This device complies with CE Certification pursuant to EN 55011 2007 A2 2007 EN 60601 1 2 2007 FDA 501 K Certification 501 K Number K091288 SFDA Certification Certified Number 1310488 WEEE Compliance Statement x lt Microtek International Inc operates under full compliance with the WEEE Directive Among the requirements of the Directive are the marking of any applicable equipment placed in the EU market with the WEEE symbol a crossed out wheeled bin as shown at left demonstration of the implementation of a take back program and meeting recycling targets ISO Compliance Statement Comply with the requirements of the international standard ISO 9001 2000 and ISO 13485 2003 4 Medi 5000 User s Manual Guidance and Manufacturer s Declaration for EMC Directive For EQUIPMENT or ME SYSTEM that are not LIFT SUPPORTING Recommended separation distances between rtable and mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM The ME EQUIPMENT or ME SYSTEM is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the ME EQUIPMENT or ME SYSTEM can h
19. dy surface do not go off either of hands from holding the foam supports NOTE Due to the heavy weight of the package about 44 pounds make sure you can handle it properly before removing it from the carton 6 Turn over the foam supports and make them stand vertically 16 Medi 5000 User s Manual 7 Lift up the upper foam support 8 Pull out the Transparent Media Adapter 2 1 TMA from the bottom foam support Then pull out the digitizer Finally remove the digitizer from the wrapped plastic bags and place them on a flat and stable surface where there is enough space for positioning the components Once the digitizer has been placed in a suitable location and is ready to be connected to the computer you are ready to step forward to the installation of the necessary software and hardware for the digitizer Medi 5000 User s Manual 17 Package Contents After you have unpacked your digitizer package please check for the major components listed below steno con ee eames Medi 5000 digitizer lower base 141 015620 Mammography 18 x 24 cm Film Holder PN 215 00 770103 Transparent Media Adapter TMA 141 015625 g Software CD Hi Speed USB cable 141 015676 PN 121 44 150504 Mammography C 24 x 30 cm Film Holder PN 215 00 770104 Power cord PN EU 121 46 032005 a A ee R PN US 121 46 500000 PN TWN 121 46 570000
20. e of the 24 x 30 cm Mammography films at a time 1 Place 24 x 30 cm Mammography Film Holder on the digitizer glass surface Make sure to orient the film holder with the Microtek logo facing up Important Align the holder s front corners firmly against the top corners left and right of the U shaped ruler located at the front of the digitizer When placing the film holder make sure that the Calibration window on the glass surface is kept clear and free of obstruction at all times Note that the arrow marks on both the film holder and digitizer s top ruler are pointing to each other Calibration window Medi 5000 User s Manual 31 2 Place the 24 x 30 cm Mammography film to be scanned inside the frame of the film holder with the letter R or L oriented correctly and with the correct side up 32 Medi 5000 User s Manual Scanning Mammography Films ScanWizard Medi is a scanning software designed by Microtek for X ray films or reflectives scanning used for a medical purpose Its user friendly interface enables you to easily start the scanning process and finish all the scan jobs Refer to the ScanWizard Medi software manual for more details 1 Follow the procedures for Positioning Mammography Films to place the film holder and mammography film on the digitizer glass surface Launch ScanWizard Medi either as a stand alone by clicking the program icon or by using the File lmpor
21. elp prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the ME EQUIPMENT or ME SYSTEM as recommended below according to the maximum put power of the communications equip metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE 1 At 80 MHz and 600 MHz the separation distance for the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people The ME declaration electromagnetic Emission The ME system is intended for use in the electromagnetic environment specified below The customer or the user of the Model 006 should assure that it is used in such an environment Immunitytest IEC 60601 Test Level Electromagnetic environment guidance The ME system must emit electromagnetic energy in order to perform its intended function Nearby electronic equipment may be affected The ME system must be used only in a shiekied location with a minimum RF Shielding effectiveness and for each cable that exits the shielded location a Harmonic emissions ca o RF filter attenuation of 80 dB from IEC 61000 3 2 10 MHz to 20 MHz 100 d6 from 20 MHz to 80
22. film holder with the Microtek logo facing up Important Align the holder s front corners firmly against the top corners left and right of the U shaped ruler located at the front of the digitizer When placing the film holder make sure that the Calibration window on the glass surface is kept clear and free of obstruction at all times Microtek logo Note that the arrow marks on both the film holder and digitizer s top ruler are pointing to each other Calibration window Medi 5000 User s Manual 29 2 Place the 18 x 24 cm Mammography film to be scanned inside the individual frame of the film holder with the letter R or L oriented correctly and with the correct side up e Place the film containing the image of the right breast inside the frame labeled with R mark on the top of the holder Orientation of the film is critical Make sure that the side of the film with the right breast image is positioned toward the right side of the frame e Place the film containing the image of the left breast inside the frame labeled with L mark on the top of the holder Orientation of the film is critical Make sure that the side of the film with the left breast image is positioned toward the left side of the frame 30 Medi 5000 User s Manual B Using the 24 x 30 cm Film Holder To scan 24 x 30 cm Mammography film use the 24 x 30 cm Film Holder which can hold one piec
23. g for Taiwan shipping as T Keep in a dry place MA Keep away from magnets The storage direction of the top of the box T Fragile handle with care 6 Store 6 layers of boxes in one pallet 10 Medi 5000 User s Manual Table of Contents Pr PAGC 2 2csscste2ccecieccecsescees cade secs aeeciecceeccaced eee avacenesendi esaceeeuiead rinkuna Tapn 2 Safety Regulations i iicsciccicccciecccscsceccsccscscsscsccecccscnsescssssceetecsccscvesseceeees 3 FCC Compliance Statement ccccceeeeeee cece eee ee ee ee eens tena eeeee ease eenaeae 3 Regulations eoio a E E E E 4 Guidance and Manufacturer s Declaration for EMC Directive 5 Safety Precautions cicera ea a aE E a EE 7 Labels and Markings isivicsiatcvnndiaieaita stains voddctuleseaswannimadsiteetwetalty En EE 9 On The DEVICE siiosesacidivessiuiberdeauedencashineetedededonmespungawneduad scnenienerenate 9 On The Package Carton ccccceeee eee eee cece eee eens eee na eens E 10 Knowing about Your Film Digitizer 2 2 2 0 ceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 13 Features of the Medi 5000 eececeee cece teeter eee nett eee ee eee nae 14 System RequireMents cceceee cece eect eee ee eee ee tenet eens teste tae eS 14 Unpacking Your Film Digitizer 20 2cececeeeeeeeeeeeeeeeeeeeeeeeeneeeeeeeeeeee 15 LOOKING for Dam g sirenita eiae ties 15 Unpacking Package Contents ccccecceeee eset eens tenets ee ea teeta eae eeeeeae
24. h button Scan Press to execute the scan function fast 6 POWER Indicator Amber Indicates the digitizer is on or off 7 READY Indicator Green Indicates the status of the digitizer For more details refer to the Troubleshooting section of this manual 8 U shaped Horizontal Ruler Used to measure the width of the images Medi 5000 User s Manual 21 No Rear View Names of Parts Functions of Parts Power Switch Turns the digitizer on or off Power Connector Connects the digitizer to the power cord Hi Speed USB Port Connects the Hi Speed USB USB 2 0 cable to the computer Bl ow N gt 15 pin Accessory port Connects the TMA to the digitizer 22 Medi 5000 User s Manual Installing Your Film Digitizer Installing the Software Important Do not remove the yellow stickers from your digitizer until you are told to do so You must install all software before connecting your digitizer Always close any open programs and turn off Anti virus utilities before installing software 1 Turn on your computer 2 Place the Medi 5000 CD into your CD ROM drive 3 Follow the on screen instructions to install the driver and software NOTE If the Microtek Software Installer screen does not come up automatically double click the following in succession My Computer the CD ROM icon then cdsetup exe to start the installer program 4 To install the
25. humidity 20 to 85 Storage temperature 14 to 140 F 10 to 60 C Relative humidity 20 to 95 Specifications software bundles and accessories are subject to change without notice Not responsible for typographic errors 44 Medi 5000 User s Manual
26. on the digitizer s flatbed NOTE Do not use any detergents synthetic cleaning solutions cleaning naphtha or other solvents to clean the glass surface directly 40 Medi 5000 User s Manual Maintenance After usage for a period of time the parts inside your digitizer such as the light source may become worn out and a problem such as insufficient light supply may occur In this cases contact your local dealers or wholesales for the maintenance services NOTE Your digitizer need a professional to perform the required service or maintenance Do not attend to fix or perform the maintenance by yourself or it may cause dangers to you or the digitizer Medi 5000 User s Manual 41 Troubleshooting The green LED on the front panel indicates the status of the digitizer The amber LED beside it stands for power and should always stay on steady when the digitizer is on All On Ready to scan j Green Flashing Scanning L J I All Off digitizer is off READY Indicator Green POWER Indicator Amber If you encounter any problems check the section below and follow the suggested solution if your problem is listed You may also want to go over installation steps 1 to 5 as described in the Initial Setup section of this document to make sure that you have followed all procedures properly 1 No light comes on when the digitizer is turned on Make sure your digitizer is connecte
27. s 2 2 0 cesceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee 38 Care and Cleaning isciiscccccccccccccccsceccsssccccasescascscsscecseascssssaccsscvcessecsoess 40 Cleaning the Glass Surface ccccceeee eee ee cess ences ee ee teens ea eetenaeeeeeeaes 40 Maintenance ii 5 lt ic2ec22 cece ies cnceesceced cc ee ce eee aaar Eara ERA ANAT NaP RTE aaisa 41 APPONx oiicccccccccccccsccccsesessceas cease cecsncscsceccstecaseanadecsdcsseseseacacesnscasesasees 42 Troubleshooting seee nea ia agli nated a Aaa e NA Mee oe 42 Specificato MS scierie neiaa a iama a a a a a a a ei a 42 12 Medi 5000 User s Manual Knowing about Your Film Digitizer The Medi 5000 can capture details in bright and dark areas of mammography films and provide the medical professionals a convenient method to digitize the roentgenogram for the electric data storage Features include 16 bit grayscale resolution of 3200 dpi and scanning area of 12 x 16 which easily transfer mammography films into digital format images Additionally the Medi 5000 features the scanning capabilities of the other types of X ray films and reflectives such as photographs documents or prints as well Features of the Medi 5000 The Medi 5000 comes with several important features including the following e Smart Scan The Smart Scan function provides you an intelligent method for scanning X ray films With this function applied the digitizer can detect the film holder with the loaded films
28. s 15 Package Contents iis iedenccnwedascnapnneetia svat aie ictus taeds vaedautiel Ee oee 18 How to Repack Your Film Digitizer for Shipping cceeeeeeeeeee eee 19 Taking a Closer LOOK 2 1 c0sceceeceeeeeeeeeeeee eens eee eeeceeeeeeseseeeeeeeeeeeeeees 21 Front Open VIGW sis ceccrccnsedeenaswine a stengrenatedemegiend eins 21 Rear ViIGW sascccinenesecetar dese taeteamannedaccnsnavicnseadhedester eewcadnebeceendr ETa iaa 22 Installing Your Digitizer 2 2 2 2cececeeeeeee eee ee ee eee eee eee ee seen eee eeeeeeeeeeeeee 23 installing the Softwa sser noriai aa E 23 Unlocking the Digitizer sirisser aiana aa iaa 24 Installing the TMA 2 csscriedsacstveie prionsa n a Ea 25 Connecting the DIGHIZEN rsrsrsrs iri eradnpnan aa arainn Na n Ea iia 27 To the Power Adapter cccececece cence iinan an a 27 To the Hi Speed USB USB 2 0 Cable ccc ceeee cece eee ee eee eee 27 Medi 5000 User s Manual 11 Digitizing Mammography Films 0 0 010s0seeeeeeeeeeeeeeee eee ee eeeeeeeeee 29 Positioning Mammography FilMS ecceeee eee eee eee eee teeta e nena ee eeee 29 A Using the 18 x 24 cm Film Holder ccceceeeeeeeee test ee eeeaes 29 B Using the 24 x 30 cm Film Holder ccce 31 Scanning Mammography FiIMS cece eee eee eee eee eee eee estate ee ea enee 33 Digitizing X ray Films without Film Holder 2 2 22 ceeeeeeeeeeeeeeees 35 Digitizing Reflective Original
29. t A e When you need a repair service unplug the digitizer from the power outlet and consult qualified service personnel e When replacement parts are required use replacement parts that are specified by the manufacturer or have the same characteristics as the original parts e For safety reasons ensure to inspect the device before using it In addition carrying out a regular inspection at least once a year 8 Medi 5000 User s Manual Labels and Markings On The Device HRS MICROTEK fave axssw Medi 5000 A caution A FE MICROTEK KATA aleurwran asuere 0 AS TYPE i ms 00M AONNE BR OTRE UEBA INPUT RAJ AC 100 2400 1 54 pams Pm 4763H Gaze Saum Cex 6 0120 s saua O TWN Power label Commodity label for Taiwan shipping only BRAMER AR BROCK RM Microtek International Inc Resse No 6 Industry East Road 3 Science Based Industrial Park 0120 neh 07 Talman eae Ec REP iment anak Linsellesstra8e 127 129 RAM TNL RMR RE S D 47877 Wilich Germany ITONO A HTONOA TFDA label CE 0120 label for Taiwan shipping only Medi 5000 User s Manual 9 On The Package Carton i meai 5000 MICROTEK Binedi sooo RBH EC ce A 02 FE x CE 0120 label TFDA label for EU US AP shippin
30. t or Scan command from an application program Make sure you are in the X Ray scanning mode If not click the Scan Material icon in the Preview window then select X Ray as your scanning mode Reflective Select your image output type in the Type drop Gray Scale Soinen v Gray Scale 12 bit Select Gray Scale to scan the image eee in 8 bit grayscale Select Gray Scale 12 bit to scan the image in 12 bit grayscale Select Gray Scale 16 bit to scan the image in 16 bit grayscale Select your desired image output resolution in the i 4 Resolution Hal M Resolution drop down menu The recommended resolution is 600 dpi or above The default setting is 600 dpi for the X Ray mode If necessary click the Window Expansion button to reveal the image correction tools to adjust image quality Click the Smart Scan button on the control panel or the Scan button on the Medi 5000 unit to start scanning e f ScanWizard Medi is launched as a stand alone program a window Scan To Save As dialog box will appear Click the Save button then the scanned image can be saved into your selected folder or sent to your selected application To view the scanned image double click the MSmart Images icon on your desktop default folder assigned by the software or retrieve it from your assigned folder e If ScanWizard Medi is launched as a Plug In from an image editing program the sc
31. the reflective original to be scanned face down on the digitizer glass surface towards the front of the digitizer Center the top of the original along the U shaped ruler on the digitizer Launch ScanWizard Medi either as a stand alone by clicking the program icon or by using the File Ilmport or Scan command from an application program Make sure you are in the Reflective scanning mode If not click the Scan Material icon in the Preview window then select Reflective as your scanning mode Click the Overview button to perform a preliminary scan of the image which will appear in the preview window If you wish to resize the preview image drag on the edge or corner of the scan frame the floating dotted lines around the preview image This allows you to determine the final area to be scanned Specify your scanning requirements in the Settings window a Select a desired image type b Select a desired resolution c Adjust the scan frame settings if necessary 38 Medi 5000 User s Manual Scan Job Untitled1 7 Adjust image quality if necessary using the Advanced Image Correction AIC tools Clicking the Window Expansion button to reveal the image correction tools 8 If the colors in your reflective originals e g photos are faded and need restoring check the Automatic Color Restoration box in the Settings window 9 Click the Scan to button on the control
32. w and directly resize the scan frame floating dotted line around the image by dragging on the edge of corner of the scan frame When done click the Scan button to continue your scanning e If ScanWizard Medi is launched as a stand alone program a window Scan To Save As dialog box will appear Click the Save button then the scanned image can be saved into your selected folder or sent to your selected application To view the scanned image double click the MSmart Images icon on your desktop default folder assigned by the software or retrieve it from your assigned folder e If ScanWizard Medi is launched as a Plug In from an image editing program the scanned image is delivered after the scan to your application where the image can be saved viewed or printed further 36 Medi 5000 User s Manual Scan Job Untitled1 v Type Gray Scale 12 bit v Resolution 600 gt 27 Scan Frame x Scaling Output W 19 40 E Material 5 100 bd 7 04 i Image Size 34 912 KB 0 Reset th J ern ved Pee inane sa selecting press CTRL key to keep aspect ratio selection or press SHIFT key to add new job MICROTEK es Medi 5000 User s Manual 37 Digitizing Reflective Originals To scan reflective originals such as photographs documents or prints you can still use the Medi 5000 with the TMA Raise the TMA and place
Download Pdf Manuals
Related Search
Related Contents
Manual de Instalación ZyXEL PES-1014 User's Manual Juicemaster Complete ALS installation and operating instructions Samsung VCDC20 Canister VC with Twin Chamber System™, 2000 W User Manual (Windows 7) Mangrove Box 3178.000 Black Mangrove 3178.500 取扱説明書 - 日立の家電品 07/2012 ION Audio iED04 Paulmann Window 1 Copyright © All rights reserved.