Home
TRP-C51 User's Manual
Contents
1. Humidity 10 90 Non condensing Dimension 151mm X 75mm X 26mm Weight 400g Hardware Description 2 1 Panel layout DB9 DTE Male TRP C51 Bluetooth To RS232 422 485 Converter PROTECTION Converter Series 2 2 Block Diagram DC Switching 2 4G ANT V DC Regulator RS232 RS232 Driver lt P Bluetooth Hardware UART 2 3 LED Indictor Data Baud Rate Auto Detector RS422 485 Transceiver Surge Protector PWR LED When power is properly supplied to TRP C51 the PWR LED will on LINK LED Turn on Device connects availed TX LED RS232 422 485 data transmitting RX LED RS232 422 485 data receiving 2 4 DIP Switch Select RS232 or RS422 485 2 4 1 The 2 Pin DIP Switch for configuration mode SW1 2 OFF OFF RS232 SW1 2 0N ON RS422 485 2 4 Micro Touch button This button is for configure setting When you push it after the TRP C51 TX led will be blinking and stop all activities 13 Install TRP C51 23 1 Serial Connection The TRP C51 is equipped with one DB 9 male connector which is configured as a DTE data terminal equipment device All PC COM ports are DTE ports A null modem cable is required to make a connection between the PC COM port and the TRP C51 serial port 3 2 Power Connection The TRP C51 is equipped with a 2 pin terminal block and power jack Power can be supplied from terminal block or external DC plug It support wide input range from 10 30V DC 500mA po
2. Step1 Use a Null modem cable crossover female to female cable to make a connection between the TRP C51 DB 9 connector and PC DB 9 connector Host PC Step 2 Run the TRP BT Utility Null Modem Cable DB 9 Female Female crossor cable TRP ColA User may find the TRP BT utility in TRP C51 support CD TRP BT EXE the configuration screen appears TEP C51B Fe TEFP ET Series Converter Configuration TRF BT Series Converter Configuration TART Format Band Rate Parity Check stop Bit v ETAT Flow Read Configuration Factory Default Bluetooth Configuration This device Bluetooth es e Device Name Password i Master Mode Pre defined Remote BD Addres i Slave Mode Status v Write Configuration Step 3 Push the TRP C51 external button the TX light will be blinking Make sure the TRP C51 external switch fixed on the OFF OFF position id TRP BT Series Converter Configuration TRP C51B l x TEF BT Series Converter Conftieuration Com Fort com vi Band Rate Parity Check Nons d sopBt fix DART Format Bluetooth Configuration Thus device Bluetooth onic 27 I1FDEOB Password fiz a4 ie Master Mode Pre defined Remote BD Addie ooe 27 1FDEO4 Slave Mode RISA TS Flow None status Hon Disroverable o Read Configuration Factory Default Write Configuration Step 4 Select the PC RS232 COM Por
3. TRP C51 Version B Bluetooth to RS232 422 485 Converter User s Manual Printed Sep 2015 Rev 1 2 Trycom Technology Co Ltd No 35 Zhongxing Rd Guishan Township Taoyuan County 333 Taiwan Tel 886 3 350 3351 Fax 886 3 350 3352 Web www trycom com tw Copyright Copyright Notice The information in this manual is subject to change without notice to improve reliability design and function and does not represent a commitment on the part manufacturer No part of this manual may be reproduced copied or transmitted in any form without prior written permission by the manufacturer Products mentioned in this manual are mentioned for identification purposes only In this manual product names appearing may or may not be registered trademarks of their respective companies or copyright 1 Introduction The TRP C51 is high stability device that is able to re connect when the external power fail in paired mode it provides a simple and friendly interface that allows user easy to configure the serial data format Based on the 2 49 automatic frequency hopping technology It is widely used in parking towers industrial automation moving rail cars and etc TRP C51 can operate in direct link mode and paired mode when in paired mode the user just need to power two devices and they will automatically connect 1 1 Features ah Bluetooth V1 2 Class 1 compliance 2 5mW 4dBm Transmission range open filed over to 100M Auto re
4. connect when the external power lost Auto clear serial buffer when the data continuity input when re boot Auto directionally RS485 signal communication Option to 1KM when replace the direction antenna Support all common baud rate from 1 2K to 256Kbps Friendly interface TRP BT configuration windows utility RS422 and RS485 signal auto switching LED indicators for Power Link TX RX Surge protection on RS422 RS485 Power supply Screw terminal or external DC adapter Wide input range power supply DIN rail and panel mount support 2 Specifications Power requirement DC voltage input from 10V to 30V RS232 signal TXD RXD GND RTS CTS RS422 485 connection industrial plug in screw terminal RS485 signal differential 2 half duplex wires D D RS422 signal differential 4 full duplex wires TX TX RX RX Baud rate 1 2Kbps to 256Kbps Data bit 8 Support Parity check None Even Odd Stop bit 1 2 RS232 flow control RTS CTS Enable Disable Host PC com port to TRP C51 connection use null modem female female cable Plug in screw terminal wiring Accepts AWG 12 30 wires 2 Wireless transmission distance Open filed 100M Antenna cable length 1530mm RS422 485 distance up to 4000ft 1200M LED indicator Power Link TX and RX Power input type Screw terminal or DC plug 5 5 2 1 12mm 500mA Power consumption 1 2 watt Operating temperature 10 to 50 C Storage temperature 20 to 65C
5. link mode and paired connection mode User can use the host PC or Notebook which with integrated bluetooth interface to wirelessly connect TRP C51 after the installation system will generate a COM Port for TRP C51 If host PC or Notebook does not equip with Bluetooth interface you need to add USB dongle as the connection interface The approved USB dongle is Ergotech type ET BD121 that is an optional accessory for TRP C51 however TRP C51 is compatible with most of USB dongle in the market User may use own USB dongle for Bluetooth interface In the next TRP C51 operating descriptions we use ET BD121 as example Direct Mode Virtual COM 7 Pe Se TRP C51 EE EG 5 Host PC With Bluetooth Interface 5 1 Direct link mode Step1 Power on TRP C51 and select TRP C51 as slave TRP C51 accepts 10 30V DC 500mA power supply When power is correctly supplied the PWR LED will start lighting the system is up and discoverable Use TRP BT utility to select TRP C51 as slave Step 2 Install Bluetooth ET BD 121 USB dongle driver and utility User may find ET BD 121 USB dongle driver and utility it the ET BD 121 support CD Insert the CD in the CD drive on the PC the driver CD will auto run The following InstallShield screen appears Press Next gt to continue Welcome to the InstallShield Wizard for TOSHIBA Bluetooth Stack The Installshield R Wizard will install TOSHIBA Bluetooth Stack on Your computer To continue click Ne
6. rd Select a COM port Set the COM port for use we recommend using the default COM port Assignment of COM Port Mame Ww Auto Connect Auto Connect means TRP C51 will automatically connect when encounters unexpected disconnection User may choose the function enable or disable Step8 Select the installed TRP C51 icon and click mouse right button to check or change options User may rename or delete the TRP C51 here 4 Bluetooth Settings E BK Bluetooth View Help EI Bluetooth Delete Detail Create Shortcut on Desktop Rename Change Icons Connection Select Connect option you are requested a Bluetooth passkey Please Input TRP C51 password which must be same as the setting by TRP BT utility press OK TRP C51 will go into searching mode the LINK LED start to fast blinking Bluetooth Manager Bluetooth Security a Bluetooth Passkey PIM If left blank the default FIN will be used Request Device Bluetooth Device Address O0 11 B1 41 00 E4 Bluetooth Device Name TRPF CA Cancel Step9 When TRP C51 is successfully connected user may see the next screen the LINK LED stop fast blinking and turn to lighting TRP C51 is available to data communication or control You also may find TRP C51 has already been added in system device manager i Bluetooth Settings Bluetooth View Help J Bluetooth r Connection E Device Manager File Ac
7. t for TRP C51 USART Format Com Part id Step 5 Click the Read Configuration button to read the TRP C51 setting configuration Step 6 Select the baud rate from 1200 bps 256 K bps UART Format Com Part Baud Fate Data Bit Parity Check Stop Bit RTS CTS Flow Control Step 7 Select the Parity Check LART Format Com Port 40M ti Baud Aate J600 b Data Bit 8 Parity Check None bi Mone Odd RTS TS Flow Control None z Step 9 Select the Stop Bit UART Format Com Fort COM p Baud Fate 3600 vi DataBit z Parity Check None d Stop Bit RTS CTS Flow Control Step 10 Select the RTS CTS Flow Control USAT Format Com Port OM Baud Rate 9800 Data Bit Br Parity Check Nore i Stop Bit RTS CTS Flow Control HELE z Hone Step 11 Select the device name and password Bluetooth Configuration This device Bluetooth foot 27 1FDEOE Device Name TRP C51B Password 1234 fa Master Mode Pre defined Remote BD Addie D01C 97 1FDE04 EC Slave Mode Non Distoverable In TRP C51 paired mode it is necessary to set same name and password for both TRP C51 Master and Slave Step12 Select the Master or Slave mode TRP C51 can be defined as Master device or Slave device here If define TRP C51 as a Master and input a Slave BD address this Master of TRP C51 will search only for the matched BD address of Slave device 5 How to use TRP C51 TRP C51 support direct
8. tected and converted between each other The communicating range can up to 100M 4 3 How to set up TRP C51 paired connection mode Step 1 Use TRP BT utility to set one TRP C51 as master and another TRP C51 as slave Both TRP C51 devices name and password must be same Step 2 If define TRP C51 as a Master and input a Slave BD address this Master of TRP C51 will search only for the matched BD address of Slave device Step 3 When both units LINK LED become constant lighting both TRPC51 had been successfully connected each other the system is ready and workable Paired Mode PU 4 0 gt OS a TRP C 51 Ebacfranic scales ree Ramala VO NR TRP C51 K SF med AJ 6 Er WALSE Control System Client React PLC 6 How to test TRP C51 Trycom Technology Co Ltd offers test utility this is utilities may help user to demo and test TRP C51 fast and easily User may find the utilities in Trycom support CD or download from Trycom web www trycom com tw direct to perform TRPCOM exe from the directory 6 1 RS232 Loop Back Test RS232 loop back test wiring connection 6 2 RS422 Loop Back Test RS422 loop back test wiring connection P RS485 RS422 1 DC 10 30V 6 3 Loop Back Test Software STEP1 Run the TRPCOM EXE utility STEP2 Click the Setting to set the com port and baud rate then press OK g TEPCOM 2013 Test Utility communication configuration Initial Set
9. ting eomz 3600 Communication Protocal ASCII Co Wodbus RTU Default Exit Description TRPCOM utility is designed to test TRP Series modules In the settings menu be sure to select the ASCII Modbus protocal com port parameters FP ASCH Checksum Enable from the drop down menus and selecting Checksum Selects Enable or Disable before continuing Please note COM is an example of COM port number the real COM number is assigned by user PC STEP3 Click the Terminal then select Loop back enable the counter value and pass value will be synchronized counts F J TRPCOM Test Utility Version 2013Q3 Pe E Terminal command Input send Command ABCDEF GHIJKLMNOPGRSTUVARYZ I 2 34567590 Response ABCDEFGHUELMANIOPORS TUM 1234567090 Instruction Send M Auto fao mS Clear Ei Checksum m Command Checksum The Termial Function Test Rodos Send the command and get R5405 device response 2 Test Road Ro Zd2hvith hardware control or Ro422 loop back wiring 6 4 RS485 Test RS485 test mode it can be connected to RS485 Device such as connecting TRP C28 send 01M instruction from the client side when the TRP C28 received command that will response lI01TRPC28 indicates execution completed ID 01 ID 02 ees 6 RX TRP C28 4in4out ske Slave Device gt Remote I O RX Step1 Run the TRPCOM EXE utility Step2 Click the Se
10. tion View Help General Driver Details ag na Soren EF Toshiba BT Port COME Monitors y BB Network adapters ah a devices Device type Forts COM amp LPT PCI Moder i a PCMCIA adapters Manufacturer Toshiba z of Ports COM amp LPT Location on Bluetooth RFCOMM from TOSHIBA aF Toshiba BT Port COM10 a Toshiba BT Port COM11 Device status aF Toshiba BT Port COM12 7 Toshiba BT Port COM13 a Toshiba BT Port COM14 IF pou are having problems with this device click Troubleshoot to af Toshiba BT Port COM20 start the troubleshooter ay Toshiba BT Port COM21 a Toshiba BT Port COMS iy Toshiba BT Port COMB m af Toshiba BT Port COM Troubleshoot ee Processors L Sound video and game controllers Storage volumes z System devices Use this device enable h l Universal Serial Bus controllers This device i working properly Device usage User may back to the Windows screen and Click Start Program file Bluetooth Bluetooth setting to start the second TRP C51 installation The number of TRP C51 that a Host system may install is depended on the COM Port number that the system or OS can offer 5 2 Paired mode TRP C51 paired mode allows user to make a wireless connection between 2 RS232 422 485 devices or PLC Programmable Logic Controller without hardware or software changes In this mode the data line signal and data format can be auto de
11. tting to set the com port and baud rate then press OK MATRICOM Test Utility Version 2013 Q3 0 x Termial Scan Communication Configuration Initial Setting Com 3600 Communication Protocal f ASCII Co o Modbus RTU Default Exit ASCII Checksum Enable Description TRPCOM utility is designed to test TRP Series modules In the settings menu be sure to select the ASCII Modbus protocal com port parameters from the drop down menus and selecting your Checksum Selects Enable or Disable before continuing Step3 Send command 01M and press Send button Step4 TRP C28 response received Fa TRPCOM Test Utility Yersion 2013 Q D gt TEPP IDIYTRPO28 ommand and get Ro vit 1 fla dyyare cor ntr D T of RE Ay ar iE IC 5 TRP C51 Application Direct Mode Virtual COM Host PC With Bluetooth Interface Saing R5232 Pairan Mode ped sad gt RS485 RS422 Control System Client
12. wer supply When power is correctly supplied the PWR LED will turn on and the system is ready If the power input from external Please use the power plug specification 5 5 2 1 12 mm Warning User can only choose one of following 2 power sources 1 External DC adapter 2 Screw terminal DC input Do not use both power input simultaneously 3 3 RS232 wiring connection RS232 Device GND 5 GND TXD 3 R D RXD 2 t TYD 3 4 RS485 wiring connection The RS485 mode supports the Transmit and Receive channels using 2 wire half duplex operation Refer to the pin assignment for connection as below RS465 Slave Device RS485 Slave Device TX D fE D D pan aa POO SOOS OD RX if RX The RTS CTS must be disable if the user using the RS422 485 function 3 5 RS422 wiring connection The RS422 mode supports 4 channels with full duplex operation for Receive and Transmit The data lines are in differential pairs Refer to the pin assignment for connection as below TX D l TX D RX LE TH te RX je J x X Tx R5422 Slave Device The RTS CTS must be disable if the user using the RS422 485 function 4 Getting start 4 1 TRP C51 default Settings Bluetooth Status Name TRP C51 Password 1234 Connection Mode Slave Device Discoverable UART Status Baud Rate 9600 Data Bit 8 Parity Check None Stop Bit 1 RTS CTS Flow Control Disable 4 2 Configure TRP C51
13. xt Step3 Plug in the ET BD121 USB dongle The InstallShield Wizard will request user plug in ET BD121D3 during the installation then user must plug in ET BD121 on the PC s USB port After plug in ET BD121 press Next to start installation The whole process will take few minutes when installation completed press Finish to end the process Step4 Bluetooth setting After ET BD121 driver installed back to the Windows screen and Click Start Program file Bluetooth Bluetooth setting The Bluetooth settings screen appears t Bluetooth Settings Bluetooth View Help PD 3 Bluetooth Detail Delete Step5 Click on New connection icon into the Add New Connection Wizard the USB dongle start to search all discoverable TRP C51 units Suppose just only 1 TRP C51 unit need to be installed we can see there is only one Bluetooth device been searched with the device name TRP C51 Click Next gt to continue Add New Connection Wizard Select a device Step6 Select installation mode select Express Mode The COM port is assigned by system Custom Mode Allow user freely to assign the COM Port to TRP C51 Confirm with Next gt In the next description we select Custom mode for explanation Add New Connection Wizard Welcome to the Add New Connection Wizard Step7 Assign a appropriate COM port for TRP C51 and confirm with Next gt Add New Connection Wiza
Download Pdf Manuals
Related Search
Related Contents
ユーロカーブ総合カタログ Verordnung über den Bau und Betrieb von Garagen DW088 - Service après vente HD-7084P Manual - Winegard Direct.com V7 Replacement Battery for selected Lenovo-IBM Notebooks Chapitre 7 - Intégrité des contenants – PDF Coyote (BL2500) - Digi International ASUS VC60 User's Manual Copyright © All rights reserved.