Home
User Manual SOM-5790
Contents
1. vii SOM 5790 User Manual 3 5 3 6 3 7 3 8 Chapter 4 4 1 Appendix A A 1 Appendix B B 1 Appendix C C 1 C 2 C 3 C 4 SOM 5790 User Manual Figure 3 15Serial Port 1 Configuration setup SCreen 25 Figure 3 16Parallel Port Configuration setup SCreen 26 3 4 11 Serial Port Console Redirection ees ee ee ee AR ee ee 27 Figure 3 17 Serial Port Console Redirection ee ee 27 3 4 12 Switchable Graphics iis ee ee Ee ee ee EA Re RA AA ee ee ee ee ee 28 Figure 3 18Switchable Grapbice iss ee ee nennen 28 3 4 13 Sandybridge DTS Configuration ese ee ee ee ke ee 29 Figure 3 19Sandybridge DTS Confouraton 29 3 4 14 Sandybridge PPM Configuration sesse dees ese ee ee ek ee ee ee ee 30 Figure 3 20Sandybridge PPM Processor Power Module Configu CH AE N ER ER EE 30 OS TE EE EE 31 3 5 1 System Agent SA Configuration ussesenneessnnnennnennnnn nn 31 Figure 3 21System Agent SA Configuration ese ee 31 Figure 3 22 1ntel IGFX Configuration ees see ee ee ee ee 32 Figure 3 23LCD Control 33 Figure 3 24NB PCle Configuration ese ee ee ee ee 34 3 5 2 PCH IO CGonfouraton renerne ee ee AR Re renee 35 Figure 3 25PCH IO Configuration ese ee nennen 35 Figure 3 26USB Contouraton ee ee ee ee ee ee 36 Figure 3 27PCI Express Configuration sees ee ee se ee ee ee ee 37 Boot Settings ee ee ee Re ee AR Re ee EEG ee be ee ee 38 Figur
2. 0010 001F Motherboard resources 0020 0021 Programmable interrupt controller 0022 003F Motherboard resources 0040 0043 System timer 0044 005F Motherboard resources 0060 0060 Standard 101 102 Key or Microsoft Natural PS 2 Keyboard 0061 0061 System speaker 0062 0062 Microsoft ACPI Compliant Embedded Controller 0063 0063 Motherboard resources 0064 0064 Standard 101 102 Key or Microsoft Natural PS 2 Keyboard 0065 0065 Motherboard resources 0066 0066 Microsoft ACPI Compliant Embedded Controller 0067 OO6F Motherboard resources 0070 0071 System CMOS real time clock 0072 007F Motherboard resources 0080 0080 Motherboard resources 0081 0083 Direct memory access controller 0084 0086 Motherboard resources 0087 0087 Direct memory access controller 0088 0088 Motherboard resources 0089 008B Direct memory access controller 008C 008E Motherboard resources 008F 008F Direct memory access controller 0090 009F Motherboard resources 00A0 00A1 Programmable interrupt controller 00A2 OOBF Motherboard resources 00C0 OODF Direct memory access controller OOEO OOEF Motherboard resources OOFO OOFF Numeric data processor 01F0 01F7 Primary IDE Channel 0274 0277 ISAPNP Read Data Port 0279 0279 ISAPNP Read Data Port 02F8 O2FF Communications Port COM2 0378 O37F Printer Port LPT1 03B0 O3BB Intel R HD Graphic 03C0 03DF Intel R HD Graphic 03F6 O3F6 Primary IDE Channel 03F8
3. O3FF Communications Port COM1 0400 041F Motherboard resources 04D0 04D1 Motherboard resources 0500 053F Motherboard resources 0800 087F Motherboard resources SOM 5790 User Manual 50 Table C 1 System I O ports 0A00 OAOF Motherboard resources 0A79 0A79 ISAPNP Read Data Port ODOO FFFF PCI bus C 2 DMA Channel Assignments Channel Function Available Available Available Available Direct memory access controller Available Available AI OOP OND O Available C 3 Interrupt Assignments Table C 3 Interrupt assignments Interrupt Interrupt source NMI Parity error detected IRQ0 System timer IRQ 1 Standard 101 102 Key or Microsoft Natural PS 2 Keyboard IRQ 2 Available IRQ 3 Communications Port COM2 IRQ A Communications Port COM1 IRQ5 Available IRQ6 Available IRQ 7 Available IRQ 8 System CMOS real time clock IRQ 9 Microsoft ACPI Compliant System IRQ 10 Available IRQ 11 Available IRQ 12 PS 2 Compatible Mouse IRQ 13 Numeric data processor IRQ 14 Primary IDE Channel IRQ 15 Available 51 SOM 5790 User Manual C 4 1st MB Memory Map Table C 4 1st MB memory map Addr range Hex Device 00000000 0009FFFF System board 000A0000 OOOBFFFF Intel R HD Graphic 000A0000 OOOBFFFF PCI Bus 000C0000 OOOCFFFF System board 000D0000 OOODFFFF
4. SOM 5790 AD ANTECH Enabling an Intelligent Planet Copyright The documentation and the software included with this product are copyrighted 2011 by Advantech Co Ltd All rights are reserved Advantech Co Ltd reserves the right to make improvements in the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable How ever Advantech Co Ltd assumes no responsibility for its use nor for any infringe ments of the rights of third parties which may result from its use Acknowledgements Intel and Pentium are trademarks of Intel Corporation Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All other product names or trademarks are properties of their respective owners Product Warranty 2 years Advantech warrants to you the original purchaser that each of its products will be free from defects in materials and workmanship for two years from the date of pur chase This warranty does not apply to any products which have been repaired or altered by persons other than repair personnel authorized by Advantech or which have been subject to misuse abuse accident or improper installation Advantech assumes no liability under the terms of this warranty as a consequence
5. Disabled for Windows XP Enabled Disabled Execute Disable Bit This item allows users to enable or disable the No Execution page protection technology Enabled Disabled Hardware Prefetcher This item allows users to enable or disable the Mid Level Cache L2 prefetcher Enabled Disabled Adjacent Cache Line Prefetch This item allows users to enable or disable the adjacent cache line prefetch fea ture Enabled Disabled Intel Virtualization Technology This item allows users to enable or disable the Intel Virtualization Technology When enabled a Virtual Machine Manager VMM can utilize the additional hardware capabilities provided by Vanderpol Technology Enabled Disabled 15 SOM 5790 User Manual 3 4 4 SATA Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc SATA Controller s Enabled Figure 3 7 SATA Configuration select RAID and capture m SATA Controller s This item allows users to enable or disable the SATA controller s Enabled Disabled m SATA Mode Selection This item allows users to select the operation mode of SATA controller s IDE AHCI RAID m Aggressive LPM Support Enable PCH to aggressively enter link power state Enabled Disabled Software Feature Mask Configuration RAID option ROM or Rapid Storage Technology driver will refer to this configu ration to control the storage features Alternate ID Report alternate Device ID Enabled
6. 2 Specifications 1 2 1 Standard System On Module functions E Processor Intel Core i7 i5 i3 and Celeron processors For detailed CPU support information please contact your sales representative m BIOS AMI EFI 8MB Flash Chipset Intel QM67 Chipset Intel Smart Cache Intel Core i7 6 MB Quad Core or 4 MB Duo Core Smart Cache Intel Core i5 i3 3 MB Smart Cache Intel Celeron 2 MB Smart Cache E System memory 2 x 204 pin SODIMM support non ECC DDR3 1066 1333 up to 16 GB H Power management Supports enhanced Intel SpeedStep technology SO S3 S4 S5 CO C1 C1E C3 C6 C7 and ACPI APM Mm SATA interface 2 SATAIII channel up to 600MB s and 2 SATAII channel up to 300MB s Mm PATA interface 1 IDE channel m Watchdog timer 6554 levels timer interval from 0 to 6553 sec multi level and multi option WatchDog Timer m USB interface Supports 8 USB 2 0 ports m Expansion Interface Supports PEG x16 5 PCle x1 PCle x4 option PCle to PCI PCle to IDE PCI LPC SMBus DC SOM 5790 User Manual 2 1 2 2 Display Interface 1 2 3 1 2 4 1 2 5 1 2 6 Chipset Intel Core i processor integrated 6th generation graphics core with 12 execution units Support DX10 1 Open GL 3 0 full AVC VC1 MPEG2 HW Decode Display type VGA LVDS Display mode VGA port 2048x1536 LVDS Dual Channel 18 24 bit HDMI DVI 1920x1200 Displayport 2560x1600 GMA driver supports up to 2 independent d
7. 2E8h IRQ 3 4 5 6 7 10 11 12 DMA 1 2 3 25 SOM 5790 User Manual 3 4 10 3 Parallel Port Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc Parallel Port Enabled Figure 3 16 Parallel Port Configuration setup screen M Parallel Port Disable Enable the Parallel port Enabled Disabled m Change Settings Change Parallel port resource setting m Auto lO 378h IRQ 5 lO 378h IRQ 3 4 5 6 7 10 11 12 lO 278h IRQ 3 4 5 6 7 10 11 12 IO 3BCh IRQ 3 4 5 6 7 10 11 12 l0 378h IO 278h 0 3BCh Device Mode Change Parallel port mode setting STD Printer Mode SPP Mode EPP 1 9 and SPP Mode EPP 1 7 and SPP Mode ECP Mode ECP and EPP 1 9 Mode ECP and EPP 1 7 Mode SOM 5790 User Manual 26 3 4 11 Serial Port Console Redirection Aptio Setup Utility Copyright C 2010 American Megatrends Inc Console Redirection Enabled Figure 3 17 Serial Port Console Redirection Console Redirection This item allows users to enable or disable console redirection for Microsoft Windows Emergency Management Services EMS Enabled Disabled E Out of Band Mgmt Port Select the port for Microsoft Windows Emergency Management Services EMS to allows for remote management of a Windows Server OS COM 0 COM 4 m Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection
8. CRT LVDS AC97 HDA Ethernet SATA e USB SMBus amp l2C GPIO e WDT PCLEx1 LPC SPI X2 220pins IDE e PCI e SDVO PCI Ex1 e PEG x16 Pin Assignments for X1 X2 connector Please refer to Advantech_COM_Express_Design Guide Chapter 2 You can download Advantech COM Express Design Guide from http com advan tech com Fan Connector FAN1 Fan Description Wafer 2 0 mm 3P 90D M DIP 2001 WR 03 LF W Lock Pin Pin Name 1 Fan Tacho Input 2 Fan Out 3 GND FAN _3H_2 0mm SOM 5790 User Manual 6 2 2 Mechanical 2 2 1 Jumper and Connector Location Figure 2 2 Board Layout Solder side 7 SOM 5790 User Manual 2 2 2 Board Dimension VEN mm E CH vt a yo a N a Figure 2 4 Board Dimension Solder side SOM 5790 User Manual 8 Chapter 3 BIOS Setup 3 1 BIOS Setup AMIBIOS has been integrated into many motherboards for over a decade With the AMIBIOS Setup program users can modify BIOS settings and control various sys tem features This chapter describes the basic navigation of the SOM 5790 BIOS setup Screens Aptio Setup Utility Copyright C 2010 American Megatrends Inc System Date Figure 3 1 Setup program initial screen AMI s BIOS ROM has a built in Setup program that allows users to modify the basic system configuration This information is stored in flash ROM so it retains the Setup informa
9. Solder side ee ee 8 BIOS Selup sesse I ESE EE EE EE OR EE OE a 10 Figure 3 1 Setup program initial screen 10 da EES ee OR EE side 10 MEER EE OE RE EE ae Reel 11 Figure 3 2 Main setup screen 11 Advanced BIOS Features Setup iss ese ee ee ee ee ee EA Re AA ee ee ee 12 Figure 3 3 Advanced BIOS features setup screen 12 3 4 1 ACPISetlings EE aan 13 Figure 3 4 ACPI Setting uie ese ees ee ke dee kke Re ek dee ed ed 13 3 4 2 TPM Configuration en 14 Figure 3 5 TPM Configuration enable and capture after reset 14 3 4 3 CRU Be eu ue CL LTE 15 Figure 3 6 CPU CGonfouratton Een 15 344 SATA een e UC le ET 16 Figure 3 7 SATA Configuration select RAID and capture 16 3 4 5 Intel TXT LT Configuration nenn 17 Figure 3 8 Intel TXT LT Configuration sense 17 3 4 6 PCH FW ConfiguratiON nenn 18 Figure 3 9 PCH FW Configuration RE 18 3 4 7 AMI Configuration an dede tans on v an api dam sansa ee ee 19 Figure 3 10AMT ConfiguratiON nennen ee ee Re ee ee 19 34 8 USB Configuration TT 21 Figure 3 11USB Contouraton ee ees ee ee ee Re ee ee Re ee nn 21 3 4 9 Embedded Controller Configuration 22 Figure 3 12Embedded Controller Configuration 22 3 4 10 Super IO Configuration ee ee ee RA ee ee ee 23 Figure 3 13Super IO Configuration setup screen 23 Figure 3 14Serial Port 0 Configuration setup SCreen 24
10. button is pressed Suspend Disabled S1 CPU Stop Clock S3 Suspend to RAM Lock Legacy Resources This item allows users to lock legacy devices resources Enabled Disabled m Wake system with fixed time Enable or disable system wake on alarm event System will wake on the hr min sec specified Enabled Disabled m Wake up hour Select 0 23 For example enter 3 for 3am and 15 for 3pm Default 0 m Wake up minute Range from 0 59 Default 0 m Wake up second Range from 0 59 Default 0 13 SOM 5790 User Manual 3 4 2 TPM Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc TPM SUPPORT Disable Figure 3 5 TPM Configuration enable and capture after reset TPM Support Disable or enable Trusted Platform Module TPM support Reset of platform is required Enabled Disabled TPM State TPM hardware is required Turn TPM Enable Disable System will reboot after restart in order to change this option Enabled Disabled SOM 5790 User Manual 14 3 4 3 Aptio Setup Utility Copyright C 2010 American Megatrends Inc Hyper threading Enabled Figure 3 6 CPU Configuration Hyper Threading Technology Enabled for OS optimized for Intel Hyper Threading Technology If Disabled only one thread per enabled core is enabled Enabled Disabled Active Processor Cores This item allows users to set number of processor cores is active 1 2 ALL Limit CPUID Maximum
11. have completed system configuration select this option to save changes exit BIOS setup menu and reboot the computer if necessary to take effect of all system configuration parameters m Discard Changes and Exit Select this option to quit Setup without making any permanent changes to the system configuration P Save Changes and Reset When users have completed system configuration select this option to save changes exit the BIOS setup menu and reboot the computer to take effect of all sys tem configuration parameters m Discard Changes and Reset Select this option to quit Setup without making any permanent changes to the system configuration and reboot the computer E Save Changes When users have completed system configuration select this option to save changes without exiting the BIOS setup menu Discard Changes Select this option to discard any current changes and load previous system configu ration H Restore Defaults The SOM 5890 automatically configures all setup items to optimal settings when users select this option Optimal Defaults are designed for maximum system perfor mance but may not work best for all computer applications In particular do not use the Optimal Defaults if the user s computer is experiencing system configuration problems SOM 5790 User Manual 40 m Save User Defaults When users have completed system configuration select this option to save changes as user defaults without exiting BIOS setup menu m R
12. of such events Because of Advantech s high quality control standards and rigorous testing most of our customers never need to use our repair service If an Advantech product is defec tive it will be repaired or replaced at no charge during the warranty period For out of warranty repairs you will be billed according to the cost of replacement materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example CPU speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defective obtain an RMA return merchandize authorization number from your dealer This allows us to process your return more quickly 4 Carefully pack the defective product a fully completed Repair and Replacement Order Card and a photocopy proof of purchase date such as your sales receipt in a shippable container A product returned without proof of the purchase date is not eligible for warranty service 5 Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer Part No 2006579001 Edition 2 Printed in Taiwan Novemb
13. the manufacturer s instructions Note Notes provide optional additional information Document Feedback To assist us in making improvements to this manual we would welcome comments and constructive criticism Please send all such in writing to support advan tech com Packing List Before setting up the system check that the items listed below are included and in good condition If any item does not accord with the table please contact your dealer immediately m 1x SOM 5790 Module Mm 1x Heatspreader 125 95 11mm SOM 5790 User Manual iv Safety Instructions 10 11 12 13 14 15 16 Read these safety instructions carefully Keep this User Manual for later reference Disconnect this equipment from any AC outlet before cleaning Use a damp cloth Do not use liquid or spray detergents for cleaning For plug in equipment the power outlet socket must be located near the equip ment and must be easily accessible Keep this equipment away from humidity Put this equipment on a reliable surface during installation Dropping it or letting it fall may cause damage The openings on the enclosure are for air convection Protect the equipment from overheating DO NOT COVER THE OPENINGS Make sure the voltage of the power source is correct before connecting the equipment to the power outlet Position the power cord so that people cannot step on it Do not place anything over the power cord All cautions an
14. Disabled E Port 0 3 Enable or Disable SATA Port Enabled Disabled Hot Plug Designates this port as Hot Pluggable Enabled Disabled m External SATA External SATA support Enabled Disabled SOM 5790 User Manual 16 m SATA Device Type Identify the SATA port is connected to Solid State Driver or Hard Disk Drive Hard Disk Driver Solid State Driver Spin up Device SATA Host Bus Adaptor HBA sequences disk drive initialization and spin up PHY communications is initiated via a host issued COMRESET Enabled Disabled 3 4 5 Intel TXT LT Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc Figure 3 8 Intel TXT LT Configuration Secure Mode Extensions SMX Intel CPU SMX support Enabled Disabled E Intel TXT LT Support Intel TXT support Enabled Disabled 17 SOM 5790 User Manual 3 4 6 PCH FW Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc gt Firmware Update Configuration Figure 3 9 PCH FW Configuration E Firmware Update Configuration This item allows users to Enable or disable Management Engine ME firmware re flash function Enabled Disabled SOM 5790 User Manual 18 3 4 7 Aptio Setup Utility Copyright C 2010 American Megatrends Inc Intel AMT Enabled Intel AMT Enable or disable Intel Active Management Technology BIOS extension AMT hardware is always enabled This option just controls the BI
15. O Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc PCH LAN Controller Enabled Figure 3 25 PCH IO Configuration E PCH LAN controller Enable or disable onboard Network Interface Card NIC Enabled Disabled m Wake on LAN Enable or disable integrated LAN to wake the system Enabled Disabled m Azalia Controls detection of the Azalia High Definition Audio device Choices are Disabled or Enabled If Auto is selected Azalia will be enabled if present Enabled Disabled Auto M Azalia Internal HDMI codec Enable or disable the Azalia internal HDMI DisplayPort codec Enabled Disabled High Precision Timer Enable or disable the High Precision Event Timer Enabled Disabled m SLP S4 Assertion Width Select a minimum assertion width of the SLP_S4 signal 1 2 Seconds 2 3 Seconds 3 4 Seconds 4 5 Seconds m Restore AC Power Loss Select AC power state when power is re applied after a power failure Power Off Power On Last State 35 SOM 5790 User Manual 3 5 2 1 USB Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc Enabled Figure 3 26 USB Configuration EHCI1 EHCI2 Control the USB Enhanced Host Controller Interface EHCI functions Enabled Disabled m USB Ports Per Port Disable Control Controls each of the USB ports 0 7 individually Enabled Disabled m USB Port 0 1 2 3 4 5 6 7 Disable Disable USB port Enabled D
16. OS extension exe cution Enabled Disabled Intel AMT Setup Prompt Enable or disable AMT setup prompt to wait for hot key to enter setup Enabled Disabled BIOS Hotkey Pressed This item allows users to enable or disable BIOS hotkey press Enabled Disabled MEBx Selection Screen This item allows users to enable or disable Management Engine BIOS Exten sion MEBx selection screen Enabled Disabled Verbose MEBx Output This item allows users to enable or disable MEBx verbose output Enabled Disabled Hide Un Configuration ME Confirmation Hide un configure ME without password confirmation prompt Enabled Disabled MEBx Debug Message Output This item allows users to enable or disable MEBx debug message Enabled Disabled 19 SOM 5790 User Manual Un Configure ME This item allows users to un configure ME without password Enabled Disabled Mm Intel AMT Password Write Enable This item allows users to enable or disable Intel AMT password write Password is writable when set enable Enabled Disabled Amt Wait Timer Set timer to wait before sending ASF_GET_BOOT_OPTIONS Default 0 m ASF This item allows users to enable or disable Alert Specification Format Enabled Disabled Activate Remote Assistance Process This item allows users to enable or disable trigger Client Initiated Remote Access CIRA boot Enabled Disabled m USB Configure This item allows users to enable or dis
17. PCI bus 000E0000 OOOFFFFF System board SOM 5790 User Manual 52 53 SOM 5790 User Manual AD ANTECH Enabling an Intelligent Planet www advantech com Please verify specifications before quoting This guide is intended for reference purposes only All product specifications are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of the publisher All brand and product names are trademarks or registered trademarks of their respective companies Advantech Co Ltd 2011
18. Set tings page for more Help with Terminal Type Emulation VT100 VT100 VT UTF8 ANSI 27 SOM 5790 User Manual 3 4 12 Switchable Graphics Aptio Setup Utility Copyright C 2010 American Megatrends Inc Figure 3 18 Switchable Graphics E SG Mode Select This item allows users to select switchable graphics mode Either mode requires Primary Display set to SG MUXed MUXless SOM 5790 User Manual 28 3 4 13 Sandybridge DTS Configuration Aptio Setup Utility Copyright C Inc CPU DTS Disabled Figure 3 19 Sandybridge DTS Configuration m CPU DTS This item allows users to configure ACPI thermal management If enabled ACPI thermal management uses a Digital Thermal Sensor DTS mechanism to obtain CPU temperatures If disabled ACPI thermal management uses EC reported temperature values Enabled Disabled 29 SOM 5790 User Manual 3 4 14 Sandybridge PPM Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc Enabled Figure 3 20 Sandybridge PPM Processor Power Module Configuration m EIST Configure Intel Enhanced Intel SpeedStep Technology CPU runs at its default clock speed if disabled CPU speed is controlled to be dynamically changed if enabled Enabled Disabled M Turbo Mode This item allows users to enable or disable Intel Turbo Mode Technology which can dynamically overclock processing cores to improve performance Enabled Disabled CPU C3 C6 C7 R
19. able USB configure function Enabled Disabled PET Progress This item allows users to enable or disable PET events progress to receive PET Platform Event Trap events or not Enabled Disabled Intel AMT SPI Protected This item allows users to enable or disable Intel AMT SPI write protect Enabled Disabled AMT CIRA Timeout OEM defined timeout for Management Presence Server MPS connection to be established 0 use the default timeout value of 60 seconds 255 MEBx waits until the connection succeeds Default 0 D WatchDog This item allows users to enable or disable WatchDog Timer Enabled Disabled m OS Timer Set OS watchdog timer Default 0 m BIOS Timer Set BIOS watchdog timer Default 0 SOM 5790 User Manual 20 3 4 8 USB Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc Legacy USB Support Enabled Figure 3 11 USB Configuration m Legacy USB Support Enable the support for legacy USB Auto option disables legacy support if no USB devices are connected Enabled Disabled Auto m EHCI Hand Off This is a workaround for the OS without Enhanced Host Controller Interface EHCI hand off support The EHCI ownership change should claim by EHCI driver Enabled Disabled m USB transfer time out Set the time out value for Control Bulk and Interrupt transfers 1 sec 5 sec 10 sec 20 sec Device reset time out Set USB mass storage device Start Unit comm
20. and time out value 10 sec 20 sec 30 sec 40 sec Device power up delay Set the maximum time of the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Auto Manual Device power up delay in seconds Delay ranges from 1 to 40 seconds Default 5 21 SOM 5790 User Manual 3 4 9 Embedded Controller Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc EC iManager WatchDog IRQ Figure 3 12 Embedded Controller Configuration EC iManager WatchDog IRQ This item allows users to set the IRQ number of EC WatchDog Disabled IRQ 5 IRQ 7 IRQ 14 m EC Power Saving Mode This item allows users to set board s power saving mode when system off Normal Deep Sleep CPU Shutdown Temperature This item allows users to set the value of CPU shutdown temperature Disabled 70 C 75 C 80 C 85 C 90 C 95 C 100 C 105 C m EC iManager Smart FAN This item allows users to enable or disable Smart FAN feature Enabled Disabled Backlight Enable Polarity Switch backlight enable polarity for Native or Invert Native Invert SOM 5790 User Manual 22 3 4 10 Super IO Configuration Aptio Setup Utility Copyright C 2010 gt Floppy Disk Controller Configuration Figure 3 13 Super IO Configuration setup screen m Floppy Disk Controll
21. d warnings on the equipment should be noted If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage Never pour any liquid into an opening This may cause fire or electrical shock Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel If one of the following situations arises get the equipment checked by service personnel M The power cord or plug is damaged Liquid has penetrated into the equipment m The equipment has been exposed to moisture MH The equipment does not work well or you cannot get it to work according to the user s manual M The equipment has been dropped and damaged m The equipment has obvious signs of breakage DO NOT LEAVE THIS EQUIPMENT IN AN ENVIRONMENT WHERE THE STORAGE TEMPERATURE MAY GO BELOW 20 C 4 F OR ABOVE 60 C 140 F THIS COULD DAMAGE THE EQUIPMENT THE EQUIPMENT SHOULD BE IN A CONTROLLED ENVIRONMENT CAUTION DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER S INSTRUCTIONS The sound pressure level at the operator s position according to IEC 704 1 1982 is no more than 70 dB A DISCLAIMER This set of instructions is given according to IEC 704 1 Advantech disclaims all responsibility for the accuracy of any state
22. e 3 28Boot Setup Utility ee ee ee ee ee 38 Security Setup iese ee ee ee AR ee ee ee ee ee ee ee ee ee ee ee ee 39 Figure 3 29Password Configuration 22440 nn 39 Savo amp EX see koka ee Ee AE Ee ek ee SERE ai ki al a ao in pin a pi ia ee a pi a kn pa 40 Figure 3 30Save amp Exil 40 S W Introduction 8 Installation 43 SAW INMPOGUCTION EE 44 Driver Installation saae er ren ee ee Re ee ee Re ee ee ee ee ee ee ee ee 44 4 2 1 Windows XP professional 44 EE 44 Watchdog Timer 1 45 Programming the Watchdog TimMer nennen 46 Programming GPIO essens sees sees 47 GPIO Register aaa 48 System AssignmentsS sees sesse 49 System VO de EE ia euere 50 Table C 1 System VO porte 50 DMA Channel Assignment ee ee ee ke ee ee Re ee ee Re ee ee ek Re ee ee ner 51 Table C 2 DMA channel assionments ee ee nen 51 lge ln CET 51 Table C 3 Interrupt assignments eee ee cette cette ee ke ee ee 51 Ist MB Memory Map iese esse dese ees see ee ee Se ee ee ee ee ee ee Re ee ee ee de ee ke ee ee 52 Table C 4 1st MB memory map 52 viii General Information This chapter gives background information on the SOM 5790 CPU System on Module Sections include m Introduction E Specification 1 1 Introduction SOM 5790 is a COM Express Basic Module with Type 2 pin out that fully complies with the PCI Industrial Computer Manufactures PICMG COM Express standard The new CPU module int
23. egrates Intel 2nd Generation Core i7 i5 i3 and Celeron proces sors code named Sandy Bridge which support Intel 6th generation graphics core with AVC VC1 MPEG2 HW decode It also integrates QM67 codename Cougar Point chipset which provides state of the art interface such as PCI Express Gen 2 and SATA Gen3 In a basic form factor of 125mm x 95mm the SOM 5790 provides a scalable high performance and easy to integrate solution for customers applications by utilizing a plug in CPU module on an application specific customer solution board The SOM 5790 with advanced I O capacity incorporates serial differential signaling technologies such as PCI Express Serial ATA USB 2 0 and LVDS interfaces while maintaining digital parallel signal support such as PCI and IDE SOM 5790 is the best choice for the customers looking for migration toward higher computing speeds and compatibility with older carrier board design SOM 5790 complies with the Green Function standard and supports Doze Standby and Suspend modes The small size 125 mm x 95 mm and use of two high capacity connectors based on the proven COM Basic form factor allow the COM Basic mod ules to be easily and securely mounted onto a customized solution board or our stan dard SOM DB5700 development board The SOM 5790 provides excellent processing ability via its Intel 2nd Gen Core i pro cessor dual channel LVDS DDR3 non ECC memory up to 16 GB and high defini tion audio interface 1
24. eport This item allows users to enable or disable CPU C state report to OS Enabled Disabled SOM 5790 User Manual 30 3 5 Chipset O 3 5 1 System Agent SA Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc Enabled Figure 3 21 System Agent SA Configuration E VT d This item allows users to enable or disable Intel Virtualization Technology for Directed UO VT d Enabled Disabled 31 SOM 5790 User Manual 3 5 1 1 Aptio Setup Utility Copyright C 2010 American Megatrends Inc Primary Display Figure 3 22 Intel IGFX Configuration Primary display Select which IGFX PEG PCI graphics device should be Primary Display or select SG for Switchable graphics Auto IGFX PEG PCI SG Internal Graphics This item allows users to enable or disable Internal Graphics Device Enabled Disabled Auto GTT Graphics Translation Table Size This item allows users to select the size of Translation Look aside Buffer LTB 1MB 2MB Aperture Size This item allows users to select graphics aperture size 128MB 256MB 512MB DVMT Pre Allocated This item allows users to select Dynamic Video Memory Technology DVMT pre allocated Fixed graphics memory size OMB 32MB 64MB 480MB 512MB DVMT Total Gfx Mem This item allows users to select DVMT 5 0 total graphics memory size 128MB 256MB MAX Gfx Low Power Mode This option is applicable for sma
25. er 2011 SOM 5790 User Manual ii Declaration of Conformity CE This product has passed the CE test for environmental specifications when shielded cables are used for external wiring We recommend the use of shielded cables This kind of cable is available from Advantech Please contact your local supplier for ordering information CE This product has passed the CE test for environmental specifications Test conditions for passing included the equipment being operated within an industrial enclosure In order to protect the product from being damaged by ESD Electrostatic Discharge and EMI leakage we strongly recommend the use of CE compliant industrial enclo sure products FCC Class B Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installa tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfer ence to radio or television reception which can be determined by turning the equip ment off and on the user is encouraged to try to correct the interference by one o
26. er Configuration Disable Enable the floppy disk controller Enabled Disabled m Change Setting Change an optimal setting floppy disk controller m Auto IO 3f0h IRQ 6 DMA 2 IO 3fOh IRQ 3 4 5 6 7 10 12 DMA 1 2 3 IO 370h IRQ 3 4 5 6 7 10 12 DMA 1 2 3 E Device Mode Change mode of floppy disk controller Read Write Write Protect 23 SOM 5790 User Manual 3 4 10 1 Serial Port 0 Configuration Aptio Setup Utility Copyright C Serial Port Enabled Figure 3 14 Serial Port 0 Configuration setup screen Serial Port Enable or Disable Serial Port COM Enabled Disabled Mm Change Settings Select an optimal setting for serial port 0 m Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 SOM 5790 User Manual 24 3 4 10 2 Serial Port 1 Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc Serial Port Enabled Figure 3 15 Serial Port 1 Configuration setup screen Serial Port Enable or Disable Serial Port COM Enabled Disabled m Change Settings Select an optimal setting for serial port 0 m Auto IO 3E8h IRQ 7 IO 2F8h IRQ 3 4 5 6 7 10 11 12 IO 3F8h IRQ 3 4 5 6 7 10 11 12 IO 2E8h IRQ 3 4 5 6 7 10 11 12 IO 3E8h IRQ 7 DMA 3 IO 3F8h IRQ 3 4 5 6 7 10 11 12 DMA 1 2 3 IO 2F8h IRQ 3 4 5 6 7 10 11 12 DMA 1 2 3 IO 3E8h IRQ 3 4 5 6 7 10 11 12 DMA 1 2 3 IO
27. estore User Defaults The users can select this option to restore user defaults 41 SOM 5790 User Manual SOM 5790 User Manual 42 S W Introduction amp Installation 4 1 S W Introduction The mission of Advantech Embedded Software Services is to Enhance quality of life with Advantech platforms and Microsoft Windows embedded technology We enable Windows Embedded software products on Advantech platforms to more effectively support the embedded computing community Customers are freed from the hassle of dealing with multiple vendors Hardware suppliers System integrators Embedded OS distributor for projects Our goal is to make Windows Embedded Software solu tions easily and widely available to the embedded computing community 4 2 Driver Installation The Intel Chipset Software Installation CSI utility installs the Windows INF files that outline to the operating system how the chipset components will be configured 4 2 1 Windows XP professional To install the drivers please connect to the website http support advantech com tw download the drivers that you want to install and follow Driver Setup instructions to complete the installation 4 2 2 Other OS To install the drivers for other Windows OS or Linux please connect to the website http support advantech com tw to download the setup file SOM 5790 User Manual 44 Watchdog Timer This appendix gives you the infor mation about the watchdog timer programming o
28. is root bridge Default 4K 3 6 Boot Settings Aptio Setup Utility Copyright C 2010 American Megatrends Inc Setup Prompt Timeout Figure 3 28 Boot Setup Utility Setup Prompt Timeout SOM 5790 User Manual 38 Selects number of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Default 1 Bootup NumLock State Selects the Power On state for NumLock Off On Quiet Boot If this option is set to Disabled the BIOS displays normal POST messages If Enabled an OEM Logo is shown instead of POST messages Enabled Disabled Option ROM Message Sets display mode for optional ROM message Force BIOS Keep Current Interrupt 19 Capture This item allows optional ROM messages to trap Interrupt 19 Enabled Disabled sm 1st 2nd 3rd 4th 5th 6th 7th Boot This item allows users to set boot device order Floppy Drive Other Drives BBS Priorities Specifies the BIOS Boot Specification priority sequence from available floppy drivers other drives Aptio Setup Utility Copyright C 2010 American Megatrends Inc Administrator Password Figure 3 29 Password Configuration Administrator User Password Sets administrator or user password Please refer to Password Description in BIOS Setup 39 SOM 5790 User Manual 3 8 Aptio Setup Utility Copyright C 2010 American Megatrends Inc Save Changes and Exit Figure 3 30 Save amp Exit P Save Changes and Exit When users
29. isabled SOM 5790 User Manual 36 3 5 2 2 PCI Express Configuration Aptio Setup Utility Copyright C 2010 American Megatrends Inc gt PCI Express Root Port 0 Figure 3 27 PCI Express Configuration m PCI Express Root Port x This item allows users to configure PCI Express root ports m PCI Express Root Port Controls the PCI Express root port Enabled Disabled m ASPM Support Sets Active Power State Management level Disabled LO L1 LOsL1 Auto E URR Enable or disable Unsupported Request Reporting Enabled Disabled m NFER Enable or disable device Non Fatal Error Reporting Enabled Disabled m CER Enable or disable device Correctable Error Reporting Enabled Disabled HM CTO Enable or disable Completion Timer TO Enabled Disabled E SEFE Enable or disable System Error on Fatal Error Enabled Disabled E SENFE 37 SOM 5790 User Manual Enable or disable System Error on Non Fatal Error Enabled Disabled E SECE Enable or disable System Error on Correctable Error Enabled Disabled m PME SCI Enable or Disable Power Management Event System Control Interrupt Enabled Disabled Hot Plug Enable or Disable Hot Plug Enabled Disabled m Extra Bus Reserved Extra Bus Reserved 0 7 for bridges behind this root bridge Default 0 E Reserved Memory Reserved Memory and Prefetchable 1 20MB range for this root bridge Default 10 H Reserved I O Reserved VO 4K 8K 12K 16K 20K range for th
30. isplays Four independent display supported with hybrid multi monitor capability inte grated and discrete graphics working simultaneously Audio function Audio interface Intel high definition audio interface Ethernet Chipset Intel 82579LM Gigabit Ethernet Base on IEEE 10BASE T 100BASE TX and 1000BASE T standard iManager m Board information Multi level stage WDT IRQ SCI HW restart and power off P Hardware monitor for 12 V 5 VSB CMOS Battery CPU temperature m Smart fan full speed manual speed auto speed SMBus I2C Bus E Deep Sleep Mode in S4 S5 Mechanical and environmental Dimensions COM Express Basic form factor 125 mm x 95 mm 4 92 x 3 74 Power supply voltage 12 V power only 5 VSB is needed for ACPI and ATX power Power requirement SOM 5790FG U1A1E w DDR3 1333 2GB non ECC Memory 5 34A 12V Max 0 95A 12V Win Idle Operating temperature 0 60 C 32 140 F Operating humidity 0 90 relative humidity non condensing Weight 0 103 Kg weight of total package 3 SOM 5790 User Manual SOM 5790 User Manual Mechanical Information This chapter gives mechanical and connector information on the SOM 5790 CPU System on Mod ule Sections include Connector Information m Mechanical Drawing 2 1 2 1 1 2 1 2 Connectors Board Connector There are two connectors at the rear side of SOM 5790 for connecting to carrier boards X1 220pins e
31. ll form factor only Enabled Disabled SOM 5790 User Manual 32 3 5 1 2 LCD Control Aptio Setup Utility Copyright C 2010 American Megatrends Inc Primary IGFX Boot Display VBIOS Default Figure 3 23 LCD Control Primary IGFX Boot Display Selects Integrated Graphics Video Device at POST stage This has no effect if external graphics are present VGA modes will be supported only on primary display VBIOS Default CRT LFP Secondary IGFX Boot Display Select secondary display device Disabled CRT LFP m LCD Panel Type This item allows users to select appropriate resolution and color depth for LCD panels Supported resolution may refer to BIOS setting and others based on request VBIOS Default H Panel Scaling This item allows users to enable or disable panel scaling Auto Force Scaling Off 33 SOM 5790 User Manual 3 5 1 3 NB PCle Configuration Aptio Setup Utility Copyright C PEGO Gen X Auto Figure 3 24 NB PCle Configuration PEGO Gen x Select NorthBridge PCI Express BO D1 FO standard from generation 1 or 2 Auto Gen1 Gen2 m Always Enable PEG Force PEG slot to be enabled or detect hardware signal Enabled Disabled m PEG ASPM This item allows users to enable or disable PEG Active State Power Manage ment ASPM This has no effect if PEG is not the currently active device Disabled Auto ASPM LOs ASPM L1 ASPM LOsL1 SOM 5790 User Manual 34 3 5 2 PCH I
32. ments contained herein V SOM 5790 User Manual Safety Precaution Static Electricity Follow these simple precautions to protect yourself from harm and the products from damage M To avoid electrical shock always disconnect the power from your PC chassis before you work on it Don t touch any components on the CPU card or other cards while the PC is on m Disconnect power before making any configuration changes The sudden rush of power as you connect a jumper or install a card may damage sensitive elec tronic components SOM 5790 User Manual vi Contents Chapter 1 1 1 1 2 Chapter 2 2 1 2 2 Chapter 3 3 1 3 2 3 4 General Information cscsecsesee0001 Introduction nee ee nee 2 Specifications ke was ake e von een een 2 1 2 1 Standard System On Module functions nennen 2 ae AL Gie EE EE la 3 1 2 3 Audio function 3 1 24 Ethernet soiin RR EE EE OT 3 1 2 5 Manager 3 1 2 6 Mechanical and environmental 3 Mechanical Information D ln ee 6 2 1 Board CONNECTON sea kan detan sand atan van js and ai ee lad ane 6 2 1 2 gt Fan Connector issie ed ian rn eks disa GR ea 6 Mechanical a He and 7 2 2 1 Jumper and Connector Location 7 Figure 2 1 Board Layout component side ee ee 7 Figure 2 2 Board Layout Solder sde 7 2 2 2 Board Dimension scsi ian anne adsense 8 Figure 2 3 Board Dimension Component side ese 8 Figure 2 4 Board Dimension
33. n the SOM 5790 CPU System on Module Sections include m Watchdog Timer Programming A 1 Programming the Watchdog Timer Trigger Event Note IRQ IRQ7 9 11 default disable IRQ can be set in BIOS NMI N A SCI Power button event Power Off Support H W Restart Support External WDT N A For details please refer to Manager amp Software API User Manual Chapter 6 Pro gramming Overview 6 2 Watchdog WDog Functions Class SOM 5790 User Manual 46 Programming GPIO This Appendix gives the illustra tion of the General Purpose Input and Output pin setting Sections include E System I O ports B 1 GPIO Register GPIO Byte Mapping H W Pin Name BITO GPOO BIT1 GPO1 BIT2 GPO2 BIT3 GPO3 BIT4 GPIO BITS GPI1 BIT6 GPI2 BIT7 GPI3 For details please refer to Manager amp Software API User Manual Chapter 6 Pro gramming Overview 6 3 GPIO I O Functions SOM 5790 User Manual 48 System Assignments This appendix gives you the infor mation about the system resource allocation on the SOM 5790 CPU System on Module Sections include E System I O ports m DMA Channel Assignments E Interrupt Assignments E ist MB Memory Map C 1 System I O Ports Addr range Hex Device 0000 000F Direct memory access controller 0000 OCF7 PCI bus
34. r more of the following measures Reorient or relocate the receiving antenna m Increase the separation between the equipment and receiver MH Connect the equipment into an outlet on a circuit different from that to which the receiver is connected MH Consult the dealer or an experienced radio TV technician for help iii SOM 5790 User Manual Technical Support and Assistance 1 Visit the Advantech website at http support advantech com where you can find the latest information about the product 2 Contact your distributor sales representative or Advantech s customer service center for technical support if you need additional assistance Please have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application software etc Acomplete description of the problem The exact wording of any error messages Warnings Cautions and Notes Warning Warnings indicate conditions which if not observed can cause personal injury Caution Cautions are included to help you avoid damaging hardware or losing data e g A There is a danger of a new battery exploding if it is incorrectly installed Do not attempt to recharge force open or heat the battery Replace the battery only with the same or equivalent type recommended by the man ufacturer Discard used batteries according to
35. tion when the power is turned off 3 2 Entering Setup Turn on the computer and then press lt F2 gt or lt DEL gt to enter Setup menu SOM 5790 User Manual 10 3 3 Main Setup Aptio Setup Utility Copyright C 2010 System Date Figure 3 2 Main setup screen m System time System date Set the system time and date Press the lt Tab gt key or the lt Arrow gt keys to move between fields The date must be entered in MM DD YY format The time must be entered in HH MM SS format 11 SOM 5790 User Manual 3 4 Advanced BIOS Features Setup Aptio Setup Utility Copyright C 2010 Launch PXE OpROM Disabled Figure 3 3 Advanced BIOS features setup screen E Launch PXE OpROM Enable or disable PXE option ROM for legacy network devices Enabled Disabled MH Launch Storage OpROM Enable or disable storage option ROM for legacy mass storage devices Enabled Disabled SOM 5790 User Manual 12 3 4 1 ACPI Settings Aptio Setup Utility Copyright C 2010 American Megatrends Inc Enable ACPI Auto Configuration Disabled Figure 3 4 ACPI Setting Enable ACPI Auto Configuration This item allows users to enable or disable BIOS ACPI auto configuration Enabled Disabled m Enable Hibernation Enable or disable system ability to hibernate S4 sleep state This option may be not effective with some OS Enabled Disabled ACPI Sleep State This item allows users to set the ACPI sleep state when the suspend
Download Pdf Manuals
Related Search
Related Contents
Elkay LR2522PD2 Installation Guide TOSHIBA Satellite A60 Portable Personal Computer User's Manual Audiovox PR-130 User's Manual HP 40gs - Calculatrices-hp e+p E 59 power extension Digitaler Servoverstärker SERVOSTAR 601...620 Philips Lumea SC2008 OM, McCulloch, M200-117T, 960410298, 2013-01 El Marcado “CE” en los Detectores de Gas: Problemática. Copyright © All rights reserved.