1. PPH 30 AA TCAN SSNS T N ETT 31 44 21 Switch Port iio rer ERR 32 443 LAN Port 33 ROUTE c HR 34 s Nee ede aa M 35 4 9 Table e e e 37 AO SELECT HPNA I 38 4 6 1 Device Info Test MTT E 39 4 6 1 1 Concentrator Read Packet EEE EEE Eee eee Eee eee eee 41 4 6 1 2 End Point Net Interface uu terae tena tcx tows ca ka repetat ecu duse testa ud Sows aya awed e EEEE EE 42 4 6 1 3 End Point Read Packet nsns nnn nn 44 4 6 2 DEVICE CONTO RO ee en ee ee HH 45 4 6 2 1 EOC mt 47 4 6 2 2 HPNA driver Upgrade and user speed control Bridges canines 49 46 2 3 spool
2. E 51 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 0 2 4 Add User for Bridges e eee i bete cree e da oe eee ce ee 53 463 USeEr PI EU m 57 GARTERS CONFIGURE THE NH 310H VIA CONSOLE 60 SI SEIUPONIVPERTERMINEES diei OE eRe Pie eT eee 60 5 2 RESET THE SYSTEM TO DEFAULT CONFIGURATION 0ccccecccececeeccuecscuceceuseuceeuceeeuseuesecececeueeeueeceeeceueeaueeeeeeceueeauseueeceesuueeeeereeeneeanss 60 5 9 TFTP PROTOCOL FOR FIRMWARE UPGRADE iecit Ph Ev ee bi cuca d eise tea ct ER ERE Rd 61 MRE CABLE REQUIREMENTS nnn 66 PRODUCT SPECIFICATION snnt 69 TROUBLESHOOTING sees 72 COMPLIANCE AND SAFETY INFORMATION 78 HOME NETWORKING INSTALLATION 81 MDU INSTALLATION 91 WARRANTY m 101 CHINESE o E 102 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 IET CIIM Unpacking Information 1 1 Check List Thank you for choosing Netsys NH 310H S Before installing the router please verify the contents inside the package Package Contents NH 310H or 3105 Device 4 x rubber foot
3. The password is changeable in Administrator Settings LOGIN PASSWORD Password eeeee LOGIN CANCEL Figure 4 1 Login Password 18 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 2 Select the Menu Level There is an easy Setup for end users at the setup of NH 310H with LANI ROUTE for detail configurations sys NH310H Networking your world HER ea SYSTEM LAN ROUTE HPNA System Setting The EOC MDU Managed Master supports advanced functions like hacker attack detection client filtering virtual servers special application access and a virtual DMZ host Figure 4 2 Select the Menu Level 19 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 3 Select SYSTEM Select the SYSTEM The menu below will be used frequently It includes the sub menus 79 gt SNMP Reset System Version Info and A screen is displayed as shown in S NH310 Networking your world SYSTEM LAN ROUTE HPNA Administrator Setting Syfte The MDU Managed Master supports advanced functions Firmware Upgrade Reboot Reset System Version info Log Out Figure 4 3 Select SYSTEM in the Entry Screen 20 snetsys NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 3 1
4. 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 2 2 HPNA driver Upgrade and user speed control for Bridges Click on Upgrade button in the line for each bridge and it appears the window which shows the MAC Address and Enable Disable Mode of the bridge It supports Enable or Disable for EOC End Point and also include driver upgrade The window also shows the Firmware New Version i e 2 8 4 A screen is displayed as shown in Figure 4 6 2 1 1 7 EP Firmware upgrade Windows Internet Explorer gl about blank 1 00 05 6e 02 00 02 EUG TR BEAK r 4106 Figure 4 6 2 2 1 HPNA driver Upgrade and user speed control for Bridges 49 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Click on the Start button with the default Enable Mode and it only takes short time to upgrade the driver Mozilla Firefox 3 B http 192 168 16 249 goform fx hpna ep upgrade Figure 4 6 2 2 2 Complete the HPNA driver Upgrade for Bridges 50 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 2 3 Reboot for Bridges Click on the Reboot button in the line for each one bridge and it appears the window which shows the MAC Address A screen is displayed as shown in Figure 4 6 2 3 1 Reboot Mozilla Firefox http 192 168 16 249 hpna_uperade asp Figure 4 6 2 3 1 Reboot for Bridge 51
5. Connect your PC to the Concentrator using Ethernet cable run section 4 6 1 Device Info Test and check that the details of the Concentrator are listed Still using the PC open your Internet browser and check if you have Internet access optional might require password Check that the TV reception is still clear no interference Concentrator Troubleshooting Check to make sure that your PC has a static IP address Check that the power LED and the Ethernet LED are operating If not replace the Concentrator Internet access is available please check with the service provider Ifthe problem occurred when the Concentrator was connected but without power electricity the problem is with the service provider Ifthe problem happens only when the Concentrator is powered on then a HPF Attenuator splitter must be installed between the wall outlet and the TV Repeat the test to make sure that the TV picture is now clear Please note that the EOC Concentrator and Slave signal can not pass any amplifier when you use the amplifier please bypass HCNA signal 5 5 NH 310H S 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 F 3 NH 310S End Point bridge Installation Before beginning the installation it is important to survey the installation site Connects to headofcoax Connectto infrastructure Ethernet devices Connects to Connects to 12V TV input po
6. 5 IGMP OFF OFF ON 6 Rate Control UP 1M 12 Speed Modes 7 Rate Control Down 10M 12 Speed Modes 8 QoS OFF OFF ON 9 Click on Start Note 1 The No is 1 60 2 Remark can type 60 characters 3 The VLAN ID is 0 or 2 4095 In HPNA MDU structure all of the End Points will be isolated Therefore if you don t need use 802 1Q Tag VLAN set VLAN ID 0 When you need IEEE 802 1Q VLAN Tagging application configure VLAN Id during 2 4095 4 The Upstream Rate Control have 12 Speed Modes as Full Speed 512k 1M 2M 3M 4M 6M 8M 10M 16M 20M 30M for EOC End Point 5 The Downstream Rate Control have 12 Speed Modes as Full Speed 512k 1M 2M 4M 6M 8M 10M 16M 20M 30M for EOC End Point 6 The QoS priority packet ratio is 8 4 2 1 Highest High Low Lowest 7 The above configuration settings take effect immediately after 54 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 8 In order to comply with the MDU MTU application NH 310H S is characterized by a bridged and can pass through any packets In addition to the security considerations each of the 3105 is independent 9 Regarding rate control function which must rely on flow control to limit bandwidth If client side device doesn t support flow control the upstream bandwidth control will invalid so for this case client side device must support flow control function User Add Windows I
7. Networking your world Ethernet Cable Figure 3 1 NH 310H S connection diagram 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 EE lt oetsys IP TV Server IP Gateway Etherner Cable Coaxial Cable NH 310H Multi Splitter ZINWELL NH 310H IN L Inf AIN s cm fee SEEN a m o Cote F NH 310S 2 NH 310S a Room1 Room1 3105 Room6 3105 4 NH 310S Switch Switch A g T e Wireless AP Wireless AP Wireless AP Figure 3 2 NH 310H S connection diagram 2 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Configure the NH 310H Via Web Browser The NH 310H provides a built in HTML based management interface that allows configuration of the NH 310H via Internet Browser Best viewed using Chrome or Firefox browsers In order to use the web browser configure the device you may need to allow e Web browser pop up windows from your device Web pop up blocking is enabled by default in windows XP SP2 or above e Java Scripts Enabled by default e Java permissions Enabled by default Launch your web browser and input the default IP address 192 168 16 249 in the Web page Following section user can find default password 4 1 Login The default login password is
8. and Counter test for Bridges A screen is displayed as shown in Figure 4 6 1 MDU Managed Maste No Mode MAC Address Version Spectrum pn Net Test Counter Master 00056001205 234 12 44 000566020003 284 12 44MEHz No 01 0005 6020000284 12 44MHz No 03 Figure 4 6 1 Device Info Test 39 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 The screen contains the following details Test Descriptions Concentrator Read Packet Counter Refer to section 4 6 1 1 Refer to section 4 6 1 2 Refer to section 4 6 1 3 Note 1 Version 2 8 4 EoC driver version please refer to section 4 6 2 Device Control 2 Spectrum HPNA band mode there are three modes namely Full Band 12 44MHz High Band 28 44Mhz Low Band 12 28MHz Please refer to section 4 6 2 1 EOC driver Upgrade for Concentrator 40 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 1 1 Concentrator Read Packet Counter Click on Count button in the end of line for Concentrator and it appears the window which shows the MAC Address of the Concentrator A screen is displayed as shown in Figure 4 6 1 1 and Figure 4 6 1 2 Packet Counter Mozilla Firefox http 192 168 16 249 hpna device info asp Figure 4 6 1 1 1 Concentrator Read Packet Counter Click on the Start button and the example for test resul
9. if applicable and check for image quality If you observe problems determine if the TV is faulty if so inform the homeowner resident Check for devices TVs etc connected directly to coax outlets Disconnect them Such devices can add noise to the coax network 82 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 E 3 Pre Install Inspection For the fastest and smoothest installation address any wiring or connector problems before starting the installation Inspect and Fix Wiring Inside and outside the house or residence check every visible coax or telephone wire for cracks nicks splices and or other types of coating or shielding damage Inspect and Replace Damaged Connectors Inside and outside the residence check every coax connector and splitter Look for missing components damaged connectors corrosion and or other problems Replace any damaged splitters Replace damaged and low quality coax fittings crimp screw in and others with compression type fittings Check these locations Atthe splitter Atthe wall plate On external cables running from the wall to equipment Tip 83 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Check Environment and Wiring Integrity Remember to disconnect any devices that are directly connected to the coax network not connected through an STB Remove all unused coax cables and de
10. 1 Figure 5 3 1 boot Loader Menu entry 61 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 2 Execute the TFTP tool and specify current directory which is stored the NH 310H firmware Enter the IP address of the TFTP server interface field Now the TFTP server is ready for firmware upgrading A screen is displayed as shown in Figure 5 3 2 Note We must remind you must set TFTP tool do not miss this step Tftpd 32 by Ph Jounin Current Directory D Firmware M H 31 Server interface 192 168 16 12 Show Dir Titp Server Client DHCP server Syslog server Current Action Listening on port About Settings Help Figure 5 3 2 TFTP tool for f w upgrading 62 snetsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 3 Please enter the number 2 as set TFTP Client Download A screen is displayed as shown in Figure 5 3 3 115200 BRB nl BRO REE HAW FUCO WAD HAMU Download TFTP Client Download Print Boot Parans Set Boot Params Update bootloader Please enter your number 2 Server IP 192 168 16 12 Remote File NH310H Bl dat IP address for this board 192 168 16 235 TFTP Client Menu start download set parameters your option _ 3848012504 ANSIW 1152008 1 Figure 5 3 3 TFTP Client Download 63 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S M
11. 9 95 Installation of bridge End Point Connect the bridge to the power outlet The power LED should be turned ON Connect the bridge coax line to the wall plate coax network The link LED should be turned ON Connect the TV to the bridge TV connection Connect the PC STB to the bridge via the LAN Ethernet connection Make sure that all coax connections are tight and of good quality and that the coax network in the apartment is in good condition 96 6 97 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Verification of bridge installation See the section on troubleshooting if any problems are found On Concentrator side Check if the Concentrator link LED is ON the following tests using the PC Device Info Test Refer to 4 6 1 Device Info Test Check to see that all devices appear and have the same firmware version Net Interface Test Refer to 4 6 1 2 End Point Net Interface Test Verify PER lt 1x10e 5 IPTV or lt 1x10 2 Broadband Access On bridge side Check if your bridge link LED is ON Connect to the internet and surf the web Perform a visual check of each TV to verify good video quality End Point Troubleshooting Connect the bridge directly to the Concentrator with 8dB attenuation and check for a link If yes move the bridge to the main splitter of the apartment floor and check for a link If no link then there is a proble
12. Administrator Setting To add a user or change user s password click on the Administrator Settings link in the left navigation bar A screen is displayed as shown in ys NH310H Networking your world SYSTEM LAN ROUTE Administrator Settings Set a password to restrict management access to the modem If you want to manage the modem from a remote location outside of the local network you must also specify the IP address of the remote PC After Modify Password system will Rebootll Current Password Password Re type password i 3 12 Characters Auto Logout Time 30 Min Auto Logout Time at least gt 1 Min 200 Figure 4 3 1 Administrator Settings Configuration ls 21 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 3 2 System Time Zone User can set Time Zone by connecting to a Simple Network Time Protocol SNTP server allows the Device to synchronize the system clock to the global Internet The synchronized clock in the Device is used to record the security log and control client filtering A screen is displayed as shown in S NH310H Networking your world SYSTEM LAN ROUTE HPNA System Time Zone Connecting to Simple Network Time Protocol SNTP server allows the Modem to synchronize the system clock to the global Internet Set Time Zone GMT Greenwich Mean Time Dublin Edinburgh Lisbon London Current System T
13. NH 310H pre installed on the bottom and you can find the rubber foot inside the inner box right side of the NH 310S 1x AC to DC 12V Power Adapter 1 x RJ 45 Cable Notes 1 Please inform your dealer immediately for any missing or damaged parts If possible retain the carton including the original packing materials Use them to repack the unit in case there is a need to return for repair 2 If the product has any issue please contact your local vendor 3 Do not use sub standard power supply Before connecting the power supply to the device be sure to check compliance with the specifications The NH 310H S supports 12 VDC power input 4 The power supply included in the package is commercial grade Do not use in industrial grade applications 5 Please look for the QR code on the bottom of the product the user can launch the QR code scanning program to scan and download the user s manual electronic format file snetsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 IET Hardware Description This chapter describes the important parts of the device It features the front indicators and rear connectors NH 310S Outward 2 1 Front Panel The front panel provides a simple interface monitoring of the concentrator bridged Figure 2 1 netsys saetsys PWR LAN1 LAN2 LAN3 LAN4 HCNA POWER LAN1 LAN2 NH 31 0 H L LNK ACT LNK ACT N H 3 1 0 S LNK ACT LNK ACT H L F
14. Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment can generate use and radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at owner s expense CE Mark Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substances in electrical and electronic equipment end users of electrical and electronic equipment should understand the meaning of the crossed out wheeled bin symbol Do not dispose of WEEE as unsorted municipal waste and have to collect such WEEE separately 80 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 9 Home Networking Installation Guide Caution Please note this install guide only for construction unit to install the HPNA general of home users do not need read this oi oO el E 1 Before Leaving Office Make sure you have everything you need to install and t
15. aul viet dei Ch Diplexer Multi Splitter Attenuator snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 3 4 HCNA Connections The device has been designed to operate on the coaxial cable installed in homes throughout the world They utilized the same cable and connectors commonly used for television The 2x Coaxial connector are used to connect to TV or coaxial wall socket to another device that connect its RJ 45 to the LAN card of another set of PC notebook or other internet access device or coaxial connector to TV or set top box The device s coaxial connector must support the transmission of data up to 200Mbps across the existing coaxial cable and link establish under 145dBm Hz noise floor But make sure that the connector is inserted properly and lock Ethernet cable used must conform to FCC standard to ensure data integrity and it should not exceed 100meters 328feet The NH 310H EOC Ethernet over coaxial managed MDU concentrator can support up to 60 maximum NH 310S Bridges Clients Notes 1 Please refer to Appendix E installation guide There is introduced how to install HPNA3 1 device 2 Each of the NH 310S can only be connected to 16 nodes Mac Address netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 HPNA3 1 Ethernet over Coaxial Cable MDU Application HOS EOC managed MDU Master snef sys uad Coaxial Cable
16. netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Click on the Start button and it only takes short time to reboot for each one Bridge Mozilla Firefox L3 http 192 168 16 249 goform fx hpna ep reboot Figure 4 6 2 3 2 Reboot for Bridges is done 52 netsys NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 2 4 Add User for Bridges Click the Add button in the line for each bridge and it appears the window which shows the MAC Address and Number Remark fields The Remark field is convenient to apply for the User List information such as address and hotel room number The Maximum numbers of characters is sixty A screen is displayed as shown in Figure 4 6 2 4 1 Note etc To the Number field if you would like to modify the new number of the bridge has been configured it will replace the older information 2 User Add Windows Internet Explorer 00 05 2 00 05 6 02 00 02 ARARE amp 109 Figure 4 6 2 4 1 Add User for Bridges 53 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 For example A screen is displayed as shown in Figure 4 6 2 4 2 1 Fill No as 1 NO 1 NO 60 2 Remark NO 208 TATUNG RD SEC3 HSI CHIH TAIPEI Max characters 60 3 E1 Vlan 10 0 0 No VLAN 2 4095 Tag VLAN 4 E2 Vlan 10 0 0 No VLAN 2 4095 Tag VLAN
17. update Notes 1 If the machine firmware version is too old after the firmware upgrade user must reset system to default that to avoid the new features can not use or system error occurred 2 Regarding firmware version please refer to section 4 3 7 24 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 3 5 Reboot To reboot the unit click on the Reboot link in the left navigation bar A screen is displayed as shown in Figure 4 3 5 EOC MDU Managed Master Administrator Setting Figure 4 3 5 Reboot NH 310H e Click Reboot to restart the unit e Wait at least 20 sec and refresh the web browser 25 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 3 6 Reset System To reset the system click on the Reset link in the left navigation bar A screen is displayed as shown in Figure 4 3 6 EOC MDU Managed Master Figure 4 3 6 Reset NH 310H e Click Reset to restart the system to default configuration e After upgrade the firmware and then automatically reboot e All settings will cleard and return to the default IP 192 168 16 249 Note 1 Please note that if user reset system to default this process will change all your settings back to the factory default 26 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 3 7 Version Info This function shows the version of Web Interface
18. why NH 310H S is designed to be a cost effective MDU and MTU solution With plug amp play this simply eliminates the pain in modification and high infrastructure cost With the data transmission up to 200Mbps and link establish under 145dBm Hz noise floor it meets the growing demand for high speed multimedia services Most importantly with MDU and MTU applications it allows networking for any locations such as buildings apartments hotels resorts sports center and other places that need a high bandwidth network Caution 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Safety Warnings For your safety be sure to read and follow all warning notices and instructions before using the device 9 9 9 915 DO open the device or unit Opening or removing covers can expose you to dangerous high voltage points other risks ONLY qualified service personnel can service the device Please contact your vendor for further information Use ONLY the dedicated power supply for your device Connect the power to the right supply voltage 110V AC used for North America and 230V AC used for Europe NH 310H S supports 12 VDC power input Place connecting cables carefully so that no one will step on them or stumble over them DO NOT allow anything to rest on the power cord and do NOT locate the product where anyone can work on the power cord DO NOT install nor use your device during a
19. 68 16 249 or it is the address changed by an ifconfig command via the shell running in the terminal The Default value of Subnet Mask display is 255 255 255 0 A screen is displayed as shown in Figure 4 4 1 EOC MDU Managed Master ss Moss Figure 4 4 4 LAN Setting 31 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 4 2 LAN Switch Port Setting The LAN Port Setting mode allows the user to specify the mode setting for the NH 310H Users can choose 10Mb or 100 Mb modes for cases as Force 10Mb Full Auto 10 100 Full Half Force 10Mb Half Force 100Mb Half and Force 100Mb Full The default value is Auto 10 100 Full Half A screen is displayed as shown in Figure 4 4 2 EOC MDU Managed Master Figure 4 4 2 LAN Switch Port Setting 32 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 4 3 LAN Port Status The following information provides a view of the current Ethernet ports status of the unit as below EOC MDU Managed Master Figure 4 4 3 LAN Port Status For this example the NH 310H EOC MDU managed Concentrator is connected to two NH 310S Bridges with Port 3 and Port 4 It appears Port3 Link Status Link Up 100Mb s Full Duplex Port4 Link Status Link Up 100Mb s Full Duplex Port1 Link Status Link Down and Port2 Link Status Link Down A screen is displayed as shown in Figure 4 4 3 Example Table In
20. ANUAL Ver D1 4 Please enter your option s as set parameters then enter TFTP Server IP and Remote File Name as the NH 310H firmware for upgrading A screen is displayed as shown in Figure 5 3 4 115200 BRE 1 BRE ERE WAO FUCO AH Dg 9 2 Server IP 192 168 16 12 Remote File NH310H Bl dat IP address for this board 192 168 16 235 TFTP Client Menu D start download S set parameters X exit Enter your option s Please Enter TFTP Server IP 192 168 16 12 Enter Remote File Name NH310H Bl dat IP address for this board 192 168 16 235 Enter new IP address for this board _ 01 31 40 115200 8 N 1 ROLL CAPS NUM Figure 5 3 4 Set parameters 64 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 5 Enter your option D and it will be beginning the TFTP download After Erasing and Programming flash process and NH 310H new firmware upgrade is completed A screen is displayed as shown in Figure 5 3 5 115200 BRS rate CEO hE RAD FUC MAD RAD TFTP Client Menu start download set parameters exit your option D Starting the TFTP download ESC to stop PASS Programming flash PASS Server IP 192 168 16 12 Remote File NH310H Bl dat IP address for this board 192 168 16 235 384 01 41 58 ANSIW 115200 8 N 1 NUM Figure 5 3 5 Firmware upgrade completed 65 snefsy 5 NH 310H S HPNA3 1 EOC Managed Conc
21. Concentrator and Bridge USER S MANUAL Ver D1 System Diagnostics Power and Cooling Problems If the POWER indicator does not turn on when the power cord is plugged in you may have a problem with the power outlet power cord or internal power supply as explained in the previous section However if the unit power is off after running for a while check for loose power connections power losses or surges at the power outlet and verify that the fan on back of the unit is unobstructed and running prior to shutdown If you still cannot isolate the problem then the internal power supply may be defective In this case please contact your local dealer Installation Verify that all system components have been properly installed If one or more components appear to be malfunctioning e g the power cord or network cabling test them in an alternate environment where you are sure that all the other components are functioning properly Transmission Mode The default method of selecting the transmission mode for RJ 45 ports is 10 100 Mbps Ethernet for coaxial connectors are 200Mbps HCNA It supports auto negotiation and is half duplex Therefore if the link signal is disrupted e g by unplugging the network cable and plugging it back in again or by resetting the power the port will try to reestablish communications with the attached device via auto negotiation If the device does not support auto negotiation communications can be easily lost i e
22. LATION isset 13 3 1 HARDWARE INSTALLATION arra attin tuta uta oi E gk ERE Er ttai Qr Cata ubi epa sd tad Ced E ra x Cum Cul mebad 13 3 2 PRE INSTALLATION REQUIREMENTS 0 c0cccccccccececceccnscceeceesaeseceuaceeaeusaeuenaueeceusuauecaueesaeeaeeseeueesaesseeeuaueaaeusueeseesencauaueuseeueeeaeeueusuess 13 3 9 GENERAL S pai E d DR M RR HA NE DIM des 14 3 4 HCNA CONNECTIONS 25 dc X T 15 GRARTERM CONFIGURE THE NH 310H VIA WEB BROWSER 18 NOM EN CT P 18 4 2 SELECT THE MENU LEVEL mesire oom aoc oe nae ae 19 4 3 SELECT SYSTEM is ELE E e e Lese ES 20 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 23 1 Setting 21 LN NME 22 43 E 23 qm 24 A I RODOO ogee ac lee total ae ORE 25 LE m 26 I iem 27 438 SNMP NC Y 28 44 SELECT
23. PNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 The following figure shows the rear side of the NH 310S Figure 2 3 And the table shows the description Table 2 4 Figure 2 3 Rear panel of the NH 310S Table 2 4 Connectors shown on the rear side of the device Connectors Description Type F type female For connecting HCNA port to another HCNA port with RG59 75ohm cable coaxial cable HCNA port spectrum 12M 44 2 HCNA snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Installation 3 1 Hardware Installation This chapter describes how to install the device and establish the network connections The NH 310H S may be installed on any level surface e g a table or shelf However please take note of the following minimum site requirements before you begin NH 310S must be stick the 4 rubber feet at the bottom and the NH 310H pre installed 4 rubber feet 3 2 Pre installation Requirements Before you start the actual hardware installation make sure you can provide the right operating environment including power requirements sufficient physical space and proximity to other network devices that are to be connected Verify the following installation requirement Power requirements 12VDC 1A or above The device should be located in a cool dry place with at least 10cm 4in of space at the front and back for ventilation Place the device away fr
24. WOE S Networking 24 HPNA3 1 EOC Managed Con enfi ZI Bridge 310 5 USER S MANUAE iHttp www netsys com tw _ snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Copyright Copyright 2011 by National Enhance Technology Corp All rights reserved Trademarks NETSYS is a trademark of National Enhance Technology Corp Other brand and product names are registered trademarks or trademarks of their respective holders Legal Disclaimer The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics With respect to any examples or hints given herein any typical values stated herein and or any information regarding the application of the device National Enhance Technology Corp hereby disclaims any and all warranties and liabilities of any kind including without limitation warranties of non infringement of intellectual property rights of any third party Statement of Conditions In the interest of improving internal design operational function and or reliability NETSYS reserves the right to make changes to the products described in this document without notice NETSYS does not assume any liability that may occur due to the use or application of the product s or circuit layout s described herein Maximum signal rate derived from IEEE Standard specifications Actual data throughput will vary Network conditi
25. airs for amplifier bypass along with the following per device Other basic tools for a coax Power supply installation and replacement parts Ethernet cable TAPs Splitters etc Coax cable 91 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 F 2 NH 310H Concentrator Installation Before beginning the installation survey the installation site Connects to ONU Connects to CATV or backbone access signal source Connects to Connects to the Connects to 12V ground optional root of coax infrastructure power adapter e 9 o c lt Determine the Concentrator s location Draw the connection tree coax network map of the site Attenuation map depends on the number of splitters taps and length of the coax cable Locate amplifiers if exist in the network and show them in the connection tree Find the location of the main splitter Are there other services connected to the coax cable TV SAT Docsis Moca Check that the TV reception is clear no interference Know the room and outside temperature during summer and winter If possible check that there is active Internet service to the building 9 9 9 9 92 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Pre Installation Inspection For the fastest and smoothest installation address any wiring or connector problems if seen before starti
26. allation or to alteration or repairs made or performed by any person not under control of the original owner The above warranty is in lieu of any other warranty whether express implied or statutory including but not limited to any warranty of merchantability fitness for a particular purpose or any warranty arising out of any proposal specification or sample We shall not be liable for incidental or consequential damages We neither assume nor authorize any person to assume for any other liability WARNING Warranty Void If Removed WARNING 1 NOT TEAR OFF OR REMOVE THE WARRANTY STICKER AS SHOWN OR THE WARRANTY IS VOID 2 WARRANTY VOID IF USE COMMERCIAL GRADE POWER SUPPLY IS USED AT HARSH ENVIRONMENTS 101 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Chinese SJ T 11364 2006 He i t Pb AREXAR PBB A O O O O O O EH O O O O O O BIRHEN d O O O O O O ARM e Ro EME ZAA RS SIE 5 11364 2006 AX PRA FETED ETERS PE Se SJ T 11364 2006 Ext 102
27. ame location and contact person for the switch Fill in the system options data and then click Apply to update the changes on this page 2 Community strings serve as passwords and can be entered as one of the following 3 Trap Manager A trap manager is a management station that receives traps the system alerts generated by the switch If no trap manager is defined no traps are issued Create a trap manager by entering the IP address of the station and a community string Note 1 NH 310H supports SNMP V1 V2 29 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 4 Select LAN Select LAN The menu below includes the sub menus of EE ETATIS ES INEST ISl and SIENTE A screen is displayed as shown in NH310t Networking your world SYSTEM LAN ROUTE HPNA LAN Settings x reri System Setting LAN Port Status The EOC MDU Managed Master supports advanced functions Figure 4 4 Select LAN in the Entry Screen 30 lt 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 4 1 LAN Settings The form below is used to change the IP address of the LAN Local Area Network port the NH 310H and the adm0 IP address is the CPU IP address of NH 310H for PC to remote control the NH 310H with network management The proposed IP address is either the default address of adm0 i e 192 1
28. ce Info Test penes cana Device Control Firmware Rate Control Reboot User List User User No MAC Address Version Spectrum List Firmware Reboot Add 284 12 44MHz 284 i e Upgrade Reboot Aa 284 12 44MHz Reboot 1 Master 00 05 6 00 00 29 2 EP 00 05 62 00 11 12 2 8 4 12 44MHz S 3 EP 00 05 6e 02 00 02 e Figure 4 6 2 Device Control 45 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 The screen contains the following details Function Descriptions Upgrade EOC driver Upgrade for Concentrator Notes 1 EoC driver and web firmware is different due to the Web firmware is control web UI management the EoC driver is control NH 310H and NH 310S HPNA function Please see the current driver version is 2 8 4 such as the Figure 4 6 2 2 EoC driver contains the web firmware If user would like to upgrade latest EoC driver please refer to point 3 and section 4 6 2 2 3 The first user need to upgrade latest web firmware and user need to access Device Control menu and then click the Upgrade from the Firmware table to upgrade EoC driver A screen is displayed as shown in Figure 4 6 2 46 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 2 1 EOC driver Upgrade for Concentrator Click o
29. connected directly to the bridge add a HPF or connect the TV directly to the bridge s TV connector Case 2 In case the TV connects directly to the bridge and the TV picture is still poor replace the bridge If there are still problems with the TV picture after replacing the bridge then check the connection with the service provider 99 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Case1 TV Wall Plate HPF TV TV Wall Plate TV Before leaving Concentrator unit only Rerun Device Info Test and Net Interface Test and service tests TV reception These tests ensure the performance of the full MDU network When running Device Info Test make sure you see all units When running Net Interface Test make sure the PER is less than 10e 5 and that the rates are equal to or higher than 128Mbps 100 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Warranty The original owner that the product delivered in this package will be free from defects in material and workmanship for one year parts after purchase There will be a minimal charge to replace consumable components such as fuses power transformers and mechanical cooling devices The warranty will not apply to any products which have been subjected to any misuse neglect or accidental damage or which contain defects which are in any way attributable to improper inst
30. en 12Mhz 44Mhz CATV and Antenna lis over 50Mhz 73 NH 310H S HPNA3 1 EOC ee Concentrator and Bridge USER S MANUAL Ver D1 TT 1 pere E PON NON EEE NOU TM RU ca R Be Owe NOE UMP NU RD EUR E DEP UE Please verify that the following items to help you clarify the problem 1 Verify coaxial cable use 59 75 ohm cable 2 Verify TV signal source and if available 3 Check TV signal need to over 50MHz that will be passed 4 Add TV signal repeater before NH 310H if TV signal source is too weak 5 Add attenuator before TV if TV signal is too strong 11 Weakened by the output television signal is due to environmental factors NH 310H S support signal pass through but can not guarantee to be able to maintain an appropriate TV signal output to TV If the connection distance is too long lead to output of TV signal no signal or attenuation 2 Please note NH 310H S TV signal input power is unlimited user does not need add the attenuator before NH 310H S to weaken the TV signal source 3 If TV signal is too strong leading to the advent of television ripple please add an attenuator before TV 4 1 must use 75 ohm coaxial cable If use 50 ohm impendence the performance will be less
31. entrator and Bridge USER S MANUAL Ver D1 42 Cable Requirements A 3 4 5 UTP unshielded twisted pair cable is typically used to connect the Ethernet device to the device 10Base T cable often consists of four pairs of wires two of which are used for transmission The connector at the end of the 10Base T cable is referred to as an RJ 45 connector and it consists of eight pins The Ethernet standard uses pins 1 2 3 and 6 for data transmission purposes Table A 1 Table A 1 RJ 45 Ethernet Connector Pin Assignments MDI MDI X PIN Media Dependant Media Dependant Signal Signal interface interface cross 1 TX Transmit Data RX Receive Data 2 TX Transmit Data RX Receive Data 22 3 RX Receive Data TX Transmit Data 4777 4 Unused Unused 5 Unused Unused 6 RX Receive Data TX Transmit Data Figure A 1 Standard RJ 45 repectacle connector 7 Unused Unused 8 Unused Unused Note Please make sure your connected cables are with same pin assignment as the table above before deploying the cables into your network 66 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 White Orange White Orange ES Orange BS Orange ES White Green White Green Blue Blue White Blue White Blue Green Gree
32. est results are unclear disconnect the splitter outputs and test each segment separately or two segments through the splitter to determine which segment is faulty Inspect and replace any poor quality or damaged coax connectors Tighten each coax connector along that segment Use a wrench on the splitter connections Check for any damaged coax cables Be sure to untangle any cables that have been forced behind wall plates Also check for damaged or loose barrel connectors 1 Replace the splitter s Locate any secondary splitters Look inside wall junction boxes and behind coax jacks t Detach the input to any secondary splitters Install a 56 Ohm or 65 Ohm resistor on the input of any secondary splitter s and re attach the input to the resistor Disconnect all non HomePNA devices from coax in the home those devices might add to the noise Replace the RG and STBs one by one to determine which is causing the problem 90 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 MDU Installation Guide Caution F 1 Before Leaving the Office Make sure that you have everything you need to install and test the MDU network Equipment to Install Equipment for Testing Supplies and Tools The product package includes a Notebook PC with Windows High Pass filters Concentrator and or End point device One Ethernet cable Diplexer p
33. est the home network Please bring extra equipment in case a part or component is faulty Equipment to Install Equipment for Testing Supplies and Tools Residential Gateway RG Notebook PC with Windows Compression type male female coax Set top boxes STB One 1 to 2 coax splitters with two short connectors HomePNA adapters coax cables approximately 3 feet One short CAT 5 Ethernet cable DSL tester Barrel coax connectors joiners Coax wall outlets 99 5 Coax plates Coax splitters 1 2 1 4 etc Series resistors High pass filters Coax cable RG 6 type or RG 59 75 ohm AC power strips Coax connector installation tool Wire cutter 90 degree angle connectors Other basic tools as needed 9 9 99 9 99 9 95 81 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 E 2 Homeowner Site Survey Before beginning the installation it is important to survey the installation site and plan the job Meet With the Homeowner and Survey the Home Tip Note the location of the main splitter and any secondary splitters The main splitter usually connects to an outside coax cable Locate a coax connection if one exists near every place where the customer wants a TV Try to find a location for the RG where you can connect it back to the coax network Note Some RGs may require a grounded power outlet Turn on all TVs with existing TV service
34. etc Explain New Services to the Consumer Follow the service provider s protocol How to Perform a HomePNA Network Test The test can be performed from either HomePNA handheld tester or aPC pre loaded with test tool software and connected to the Ethernet port of a bridge or other device on the coax network The HomePNA test consists of netinf short HomePNA test 1000 packets Refer to 4 6 1 2 End Point Net Interface Test To pass we recommend the HomePNA test need to achieve ZERO packet error rate for all test lines PER Reference Only 88 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 physical data rate gt 96 Mb sec Reference Only Tip 89 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 E 6 Troubleshoot amp Repair f your HomePNA test passed but your TV service does not work properly Check your DSL service or replace the RG and or STB equipment If your HomePNA test failed follow these steps to pinpoint and fix the problem s After each step re run the HomePNA test if the test still fails continue to the next step Verify that INPUT on the main splitter is disconnected All connections to coax wall jacks must come from splitter outputs Remove the cable service provider s connection to INPUT on the main splitter Use the test results to identify which network segment is failing If t
35. face signal ground 5 GND Serial Port Connector Data set ready input 6 I DSR 1 S S Not used 7 E OO Not used 8 pu Not used 9 B 9 Figure A 3 1 1 2 2 Pin1 2 3 3 E 4 4 lor 5 5 25 So 6 6 8 8 m 9 9 Pin1 Pin2 Figure A 4 Pin Assignments and Wiring for an RS 232 Cable 68 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Product Specification Key Features amp Benefits Compliant with HomePNA3 1 HomePNA3 0 over Coaxial cable HCNA specifications ITU T G 9954 Compliant with IEEE802 3 10Base T and IEEE802 3u 100Base Tx standards Compliant with IEEE802 3x Flow Control standard Provide 4 x 10 100M auto negotiation RJ 45 Ethernet ports with auto MDI MDIX NH 310H only Provide 2 x 10 100M auto negotiation RJ 45 Ethernet ports with auto MDI MDIX NH 3105 only Provides 2 x F type female coax connectors for HCNA 12M 44MHz and TV 47M 1GHz Support transmission speed up to 200Mbps over coaxial cable and link establish under 145dBm Hz Noise Floor Support point to multipoint application Support HPNA Master Endpoints driver upgrade Support IEEE802 1p Priority Mapping and IEEE802 1p TOS Priority Queue Support IEEE802 1Q Tag VLAN Pass Through Support Web Management HTTP Telnet for Remote Management NH 310H only Support HTTP and TFTP protocol for firmware upgrade NH 310H only Support monitor all endpoint NH 310S of ver
36. firmware and EOC Driver A screen is displayed as shown in ys NH310H Networking your world __ SYSTEM li AN ROUTE HPNA m Version Info Web Interface Version B4 Driver Version 2 83 Figure 4 3 7 Version Info Note 1 Web interface version is also called firmware version the NH 310H firmware extension file format is dat 27 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 3 8 SNMP Any Network Management running the simple Network Management Protocol SNMP can manage the switch provided the Management Information Base MIB is installed correctly on the management station The SNMP is a Protocol that governs the transfer of information between management and agent A screen is displayed as shown in 5 NH310H Networking your world SYSTEM LAN ROUTE HPNA SNMP Settings To export MDU Master functions in MIB Brower you must enable SNMP Server settings Enable SNMP lv n System Name HPNA MDU Master System Location System Contact Read only community public Read Write community private Enable trap i Trap hostiP 10 10 10 254 Trap port 162 Trap community public SNMP Transport UDP IPv4 d Port eae Figure 4 3 8 SNMP Settings 28 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 1 Use this page to define management stations as trap managers and to enter SNMP community strings User can also define a n
37. hey do you will be notified in advance in order for you to make necessary modifications to maintain uninterrupted service This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs Important Safety Instructions 99 5 Caution The direct plug in wall transformer serves as the main product for disconnecting The socket outlet shall be installed near the product and be readily accessible Caution Use only the power supply included with this product In the event the power supply is lost or damaged In the United States use only with CSA certified or UL listed Class 2 power supply rated 12Vdc 1A or above IN Europe use only with CE certified power supply rated 12Vdc 1A or above Do not use this equipment near water for example in a wet basement Avoid using a telephone during an electrical storm There may be a remote risk of electrical shock from lightning Do not use the telephone to report a gas leak in the vicinity of the leaking area If you experience trouble with this unit please contact customer service of your dealer immediately DO NOT DISASSEMBLE THIS EQUIPMENT It does not contain any user serviceable components 79 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 FCC Warning This equipment has been tested to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC
38. igure 2 1 NH 310H and 3105 Front Panel snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 2 2 Front Indicators The NH 310H has Six LED indicators The following Table shows the description Table 2 1 Table 2 1 LED Indicators Description and Operation LEDs Color Status Descriptions LAN1 Ethernet LED The HCNA is receiving the power and also functioning properly The HCNA is not ready or has malfunctioned The LAN port is connected to Ethernet devices The LAN port is not connected to any Ethernet devices The LAN port is connected to Ethernet devices The LAN port is not connected to any Ethernet devices The LAN port is connected to Ethernet devices The HCNA is transferring data The LAN port is not connected to any Ethernet devices LAN2 Ethernet LED LAN3 Ethernet LED The LAN port is connected to Ethernet devices The HCNA is transferring data The LAN port is not connected to any Ethernet devices The HCNA is link to another HCNA end point device The HCNA is active and it is transferring data LAN4 Ethernet LED HCNA HCNA LED The NH 310S has Six LED indicators The following Table shows the description Table 2 2 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Table 2 2 LED Indicators Description and Operation Status Descriptions On HCNA is receiving the p
39. ime Thu Jan 1 00 21 15 GMT 1970 eae Figure 4 3 2 System Time Configuration e Choose Set Time Zone and Click Apply to enable the SNTP function 22 snetsys 4 3 3 System Time NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 If user can t connect to a SNTP server to allows the Device to synchronize the system clock to the global Internet User can setup System Time A screen is displayed as shown in saetsys Networking your world NH310H SYSTEM LAN ROUTE HPNA System Time Ifyou can t connect to SNTP server to allows the Modem to synchronize the system clock to the global Internet You can setup system time Current System Time Thu Jan 1 00 23 10 GMT 1970 Month Month setup 01 12 Date Date setup 01 31 Hour Hour setup 01 24 Minute Minute setup 01 60 Year Year setup 1970 2037 Figure 4 3 3 System Time Configuration 23 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 3 4 Firmware Upgrade To update the system firmware click on the Firmware Upgrade link in the left navigation bar A screen is displayed as shown in Figure 4 3 4 EOC MDU Managed Maste Administrator Setting System Time Zone Figure 4 3 4 Firmware Upgrade The screen contains the following detail e Click Browse to select a specific file name in preparation upgrade the firmware e Click APPLY to start the firmware
40. ions to splitters are tight and of good quality Tip 86 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Install the Residential Gateway and STBs Set Top Box Test the RJ 11 jack to ensure a good DSL signal using a DSL tester Plug the RG into the power outlet Power up the RG and let it synchronize with the DSL service Verify the DSL rate on the RG Plug the RG into the coax outlet Go to the coax outlet where the first STB will be installed Plug the handheld tester or a bridge with the laptop running the diagnostic tools into the coax outlet and run the HomePNA test See shaded box in step 5 for instructions Repeat the HomePNA test for each coax outlet one at a time before attaching any STBs If all lines test fine then connect the STBs and power them up If the lines do not test well go to Appendix C troubleshoot 5 996 o RG near main splitter RG away from main splitter Main 87 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 E 5 Complete Installation Verify that the entire home network is functioning correctly Test and Verify the Home Network Run a long HomePNA test 20 000 packets or more with all devices connected See shaded box on right for instructions As the test runs Clean Up Your Work Area Sweep up and dispose of cut wires packaging materials spare parts broken parts tools
41. ith the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver The equipment and the receiver should be connected to outlets on separate circuits Consult the dealer or an experienced radio television technician for help ee Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment If this telephone equipment causes harm to the telephone network the telephone company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Also you will be advised of your right to file a complaint with the FCC if you believe it is necessary 78 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 The telephone company may make changes in its facilities equipment operations or procedures that could affect the proper functioning of your equipment If t
42. ity LED NH 32 bit MIPS 4KC CPU Microprocessor NH 310S LED Indicators Max Noise Floor 145dBm Hz SAT HCNA Transmission 12MHz 44MHz and coexist at 47MHz Spectrum Operating 0 50 C 32 F 122 F Temperature Storage 20 C 70 C 4 F 158 F External Power Adapter 12VDC 1 71 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Troubleshooting Diagnosing the Device s Indicators The Device can be easily monitored through its comprehensive panel indicators These indicators assist the network manager in identifying problems the hub may encounter This section describes common problems you may encounter and possible solutions Cause The output level of voltage is too high for short connection ee must use the attenuator to be connected with MDU Concentrator NH 310H and End Point 3105 to attenuate the transmission power level to 10dBm 5M 850MHz at least 1 M Solution Defective External power supply heck the power adapter plugging to another device or check another power adaptor plugging INH 310H S that is functioning properly If these measures fail to resolve the problem please place a power adaptor via a qualified vendor NH 310H S supports DC 12V 1A power adaptor Cause LL Solution Network interface ex a networ
43. k adapter card on the attached device network cable or coaxial cable or Ethernet port is defective netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 iThe problem is not with the HomePNA network Check your DSL service or replace the RG and or TB equipment 1 1 1 1 1 1 LLL S PRO eee OE OVIEOFOPTEDETEOPUTOFOPOPUCDEOEOPUPOEOVOTUTOFUTOFUPDFUCUEOEDEOEO UVOTUCOPUTOPOFOVOEUFOCOTOIUOEUUOTUITOF TENE DT OE TE OES EOE TE DT EE OEE DEO Tae DE ETE OE DE LENE DE EOE LE EON EDT ee DEDEDE OEE DS EOE eT ee J Answer The TV port of Concentrator connect to HCNA port of Slave is not correct It why can link establish the reason using a short cable causing HPNA signal of 3105 too strong and pass to HPNA port lof NH 310H through TV port 50MHZ high pass filter build in of NH 310H so you can create a Weak connection but as long as extend coaxial over 350m length or plug a 20db attenuator this link will be loss We recommend add a 10dB attenuator 5M 850MHz to establish a basic connection Answer Only select the rate of 12 speed modes as Full Speed 512k 1M 2M 3M 4M 6M 8M 10M 16M 20M 30M for EOC End Point Therefore you can not create a new kind of rate You can use the CATV signal you can also use the Antenna signal as long as not to conflict with Answer the HPNA signals due to HPNA working frequency is betwe
44. ly set the HyperTerminal A screen is displayed as shown in Figure 5 1 Properties Connect To Port Settings B NH 310H Bits per second v Enter details for the phone number that you want to dial Data bits 8 E Country region pats T Area code E Stop bits 1 v Phone number Flow control None v Connect using Y Figure 5 1 HyperTerminal Configuration 5 2 Reset the system to default configuration At the CLI command type the command rawaccess to reset the system to default configuration After the commencement of the previous command then type reboot command to restart the system 60 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 5 3 TFTP Protocol for firmware upgrade 1 Powered on and execute HyperTerminal within three seconds press the lt space gt to enter Loader menu You will see the boot Loader menu with the items of function selection A screen is displayed as shown in Figure 5 3 1 115200 BREME BRO REO HAW FUCO WED HAU Da 25 f CPU ADM5120 175MHz SDRAM 32MB Flash NOR 4MB Boot System Linux 2 4 18 5120 Loader Version 1 02 00 PNA Creation Date 2005 08 03 Press lt space gt key tree times to enter boot menu 2 Xmodem Download TFTP Client Download Print Boot Params Set Boot Params Update bootloader Exit Please enter your number 3848 01 07 29 ANSIW 1152008 N
45. m with the coax connection between the Concentrator and the floor and you should continue to debug this by moving closer to the Concentrator with each test If there is a link then the problem is between the main splitter of the floor and the wall plate in the apartment Again you should debug by moving closer to the wall plate with each consecutive test 98 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 If these tests don t solve the problem replace the bridge and retest Tighten all screws and check connectors jacks coax cable replace if necessary Test the Concentrator and bridge units back to back with 8dB attenuation Rx power should receive atleast 8dBm If neither of these actions solves the problem replace the bridge and retest 9 Wait for 30 seconds If the quality LED has not changed check the device if connected properly Tighten all screws and check connectors jacks coax cables replace if necessary Test the Concentrator and bridge units back to back with 8dB attenuation The quality LED should be Green Check the bridge over the coax network until you find the problematic area and fix it If not change the malfunctioning device If Device Info Test and Net Interface Test function properly then the problem is with the service provider Please check with them to verify that the service is operational e 9 Case 1 In case that TV is not
46. n OF 208 00 05 6e 01 2d 27 U Enable RD SEC3 HSI CHIH TAIPEI T Down 1 Down Down Down Down Down Figure 4 6 3 User List 24 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 J KWH Google Chrom User Erase Mo 1 Figure 4 6 3 1 Erase the No and click Start Delet Google Chrom Lo e 192 168 16 205 soform ifx hpna ep delet User Erase done Figure 4 6 3 2 User Erase done 58 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 User Edit Windows Internet Explorer about blank E ow Fur speed TEZE OFF v Figure 4 6 3 3 Edit User Config of End Point Notes 1 If user needs to change the settings in the User Information please click on the Edit to change the configuration 2 Change the settings user need click on the User list button to refresh the User Information Please refer to Figure 4 6 1 3 If need user can disable or enable IGMP and QoS function 4 IGMP support v1 v2 59 snetsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Configure the NH 310H via Console 5 1 Setup on HyperTerminal Open the HyperTerminal and set the baud rate to 115200 8N1N to proper
47. n Upgrade button in the line for Concentrator and it appears the window which shows the MAC Address the New Version and Band Mode of the firmware which contains the EOC Concentrator driver for upgrading To Band Mode it supports Full Band 12 44MHz High Band 28 44MHz Low Band 12 28MHz User can selected band mode to configure HPNA operating band frequency The pop window also shows the Firmware New Version i e 2 8 4 Note 1 If user changed Band Mode Concentrator and all End Points will auto change the same operating band frequency 2 The band mode will used in the different environments and different applications For example if your equipment noise signal i e 20MHz conflict to the EOC working frequency you have to change EOC band from full band to High Band for preventing the EOC signal overlap the video noise 9 Master Firmware upgrade Mozilla Firefox B http 192 168 16 244 hpna upgrade asp High Band 28 44MHz Low Band 12 28MHz Figure 4 6 2 1 1 EOC driver Upgrade for Concentrator 47 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Click on the Start button and it only takes short time to upgrade the driver A screen is displayed as shown in Figure 4 6 2 1 2 Mozilla Firefox L3 http 7192 168 16 248 go0fonmn fx hpna master upgrade Figure 4 6 2 1 2 Complete the EOC driver Upgrade for Concentrator 48 netsy S NH 310H S
48. n HS White Brown Eg White Brown Brown Brown Figure A 2 Pin Assignments and Wiring for an RJ 45 Straight Through Cable 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 ES White Orange ES White Green Orange Green ES White Green White Orange Blue Eg White Brown White Blue Brown BS Green Orange Eg White Brown Blue Brown White Blue Figure A 3 Pin Assignments and Wiring for an RJ 45 Crossover Cable 67 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Serial Console Interface Connector Pin Assignments The serial console interface connector is a 9 pin RS 232 D type DTE connector A null device cable is required to connect a workstation running the Linux or Windows operating system Table A 2 lists the pin assignments for the serial console interface connector Table A 2 RS 232 Connector Pin Assignments Description Pin I O Signal Name The device have one standard serial port connector located on the Not used 1 back of the device Figure A 3 shows the pin number assignments for Receive data input 2 In RXD the 9 pin male D shell serial port connector on the back of the Transmit data output 3 Out TXD device These pin number assignments conform to the industry Data terminal ready output 4 Out DTR standard for RS 232 communications Inter
49. ng the installation Inspect and replace damaged splitter and F connectors Check every coax connector splitter tap and amplifier if exists Look for missing components damaged connectors corrosion and or other problems Replace any damaged splitters taps Replace damaged and low quality coax fittings crimp screw in others Installation of the Concentrator Connect the Concentrator to the power outlet Connect the Concentrator coax line to the main splitter of the building Connect the TV service to the Concentrator TV connection Connect the Broadband or IPTV service to the Concentrator via the LAN Ethernet connection Ifthere are any amplifiers in the coax network check that they are bi directional and pass the 12 44MHz band If not a bypass network must be installed using 2 diplexers see diagram If there is an apartment which does not have an MDU unit installed and the attenuation between the Concentrator and the non HPNA apartment TV is less than 15dB an attenuator HPF should be installed at the entrance to that apartment home Without this there will be problems with the TV reception 93 5 5 NH 310H S 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Network with Diplexer Network with TAP EP Master 94 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Verification of Concentrator Installation
50. ntemet Explorer 00055e012027 0205 TATUNG RD SEC3HSICHH 8 SF NO 208 TATUNG RD SEC3 HSI CHIH TAIPEI 4 Figure 4 6 2 4 2 Example for adding new user for Bridge 55 netsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 The User Add is done Mozilla Firefox meS htp 192 168 16 249 g0form ifx_hpna_ep_add Figure 4 6 2 4 3 Example for adding new user for one Bridge 3105 tag vlan web ui examples 1 ISP ethernet switch VLAN ID 3 NH 310H NH 310S VLAN ID 3 Access 2 ISP ethernet switch VLAN ID 3 NH 310H NH 310S VLAN ID 4 Reject access 3 1 x NH 310S VLAN ID 3 NH 310H another NH 310S VLAN ID 3 Reject access 4 A NH 310S VLAN ID 3 of Ethernet port 1 NH 310S VLAN ID 4 of Ethernet port 2 Both reject access 5 A NH 310S VLAN ID 3 of Ethernet port 1 NH 310S VLAN ID 3 of Ethernet port 2 Access 56 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 3 User List Follow the example in 4 6 2 4 add a bridge there are several information appears in User Information window User can click the Edit button to modify each bridge or click the Erase button to delete each the bridge information A screen is displayed as shown in Figure 4 6 3 1 1 2 Rate Rate MAC Address Link Enable Remark Vian Vian IGMP Control Control QOS Erase Edit ID Dow
51. of NH 310H click on the Routing Table link in the left navigation bar A screen is displayed as shown in Figure 4 5 2 EOC MDU Managed Master Static Routing Routing Table List Destination Subnet Mask Gateway Metric Interface IP 192 168 160 2352552550 0000 eo Figure 4 5 2 Routing Table List The screen contains the following details Click Refresh to update currently routing list of the NH 310H 37 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 Select HPNA Select the HPNA The menu below includes the sub menus of 773 0191169 and 85 A screen is displayed as shown in S NH310tF Networking your world SYSTEM LAN ROUTE HPNA Device Info Test i Device Control System Setting User List The EOC MDU Managed Master supports advanced functions Figure 4 6 Select in the Entry Screen Note The HPNA can configure and manage NH 310H Concentrator and NH 310S Bridge HPNA functions please refer to the Function Introduction as below 38 netsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 1 Device Info Test This sub menu for Device Info Test appears the HPNA Device Information of the Numbers gt Mode Concentrator bridge MAC Address Firmware Version Spectrum for the Concentrator bridge It also includes Counter test for Concentrator and Net_Test
52. om direct sunlight heat sources or areas with a high amount of electromagnetic interference If you trying to setup basic connection between NH 310H and NH 310S you need to add at least 10dB attenuator 5M 850MHz Check if the network cables and connectors needed for installation are available Avoid installing this device with radio amplifying stations nearby or transformer stations nearby 5 5 NH 310H S 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 3 3 General Rules Before making any connections to the device take note the following rules Ethernet Port RJ 45 All network connections to the concentrator Ethernet ports must be made using Category 5 UTP or above for 100 Mbps Category 3 4 UTP for 10Mbps No more than 100 meters of cabling maybe use between the MUX or HUB and an end node HCNA Port Coaxial All Home network connections we recommend use RG59 75ohm coaxial cable and link establish under 145dBm Hz noise floor Diplexer Multi Splitter All Home network connections could be use Diplexer or Multi Splitter or use mix of them as you would like to connect an end point device Please choose according to different environments to different specifications of the Diplexer 5M 45MHz 47M 1GHz or Multi Splitter 5M 1Ghz Attenuator Establish the basic link for NH 310H and NH 310S please add a attenuator at least 10 dB 5M 850MHZz vat D ial 4 st
53. ons and environmental factors including volume of network traffic building materials and construction and network overhead lower actual data throughput rate Netsys does not warrant that the hardware will work properly in all environments and applications and makes no warranty and representation either implied or expressed with respect to the quality performance merchantability or fitness for a particular purpose Make sure you follow in line with the environmental conditions to use this product snetsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Foreword Attention Be sure to read this manual carefully before using this product Especially Legal Disclaimer Statement _of Conditions and Safety Warnings Netsys NH 310H and NH 310S are the latest technological innovation of HomePNA3 1 Ethernet over coaxial managed concentrator and bridged client respectively NH 310H EOC managed concentrator is designed to connect with NH 310S MDU bridged for MDU and MTU applications that leverage the two most popular network connections for home use 10 100Mbps Ethernet connection and coaxial cable connection It is a norm that MDU and MTU are equipped with wired network that simply transfer small files and shared applications but the need for triple play services like transferring large multimedia files such as music video photo and deliver high speed VOIP data are ever increasing This is
54. ower and also functioning properly Of HCNA is not ready or has malfunctioned On LAN port is connected to Ethernet devices The HCNA is transferring data Of The LAN port is not connected to any Ethernet devices On LAN port is connected to Ethernet devices The HCNA is transferring data Of The LAN port is not connected to any Ethernet devices On The HCNA is link to another HCNA device Power LAN1 Ethernet LED LAN2 Ethernet LED HCNA is active and it is transferring dat It IS tran rrin HCNA LED e IS active an 5 transte g aata Of HCNA is not connected Actual HCNA link speed is gt 128MB Link Quali D Actual HCNA link speed is gt 64MB and 128MB HCNA LED On Actual HCNA link speed is 64MB 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 2 3 Rear Panel The rear panel provides the physical connectors connected to the power adapter and any other network device Figure 2 2 Figure 2 2 Rear panel of the NH 310H And the table shows the description Table 2 3 Table 2 3 Connectors shown on the rear side of the device Connectors Type Description F type female For connecting HCNA port to another HCNA port with RG59 75 coaxial cable coaxial cable HCNA port spectrum 12M 44MHz HCNA LAN1 LAN2 mm LAN3 LAN4 45 or connecting to an Ethernet equipped device 5 5 NH 310H S H
55. put 1 Output 1 Input 3 Output 3 Input 4 Output 4 33 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 5 Select ROUTE Select the ROUTE The menu below includes the sub menus of 1107 and 1 SS A screen is displayed as shown in S NH310t Networking your world Static Routing basse System Setting The EOC MDU Managed Master supports advanced functions Figure 4 5 Select LAN in the Entry Screen 34 snetsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 5 1 Static Routing To setup Static Routing click on the Static Routing link in the left navigation bar A screen is displayed as shown in Figure 4 5 1 EOC MDU Managed Master Static Routing Routing Table List Destination LAN IP Subnet Mask Gateway i Figure 4 5 1 Static Routing The screen contains the following details Fields in Static Routing Field Description Destination LAN IP Enter the IP Address 0 0 0 0 of routing entry Gateway Enter the Gateway address of routing entry e Click Add to add the information that has been entered 35 snetsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Notes 36 lt 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 5 2 Routing Table List To view the Routing entry table list
56. reset to the wrong mode whenever the attached device is reset or experiences a power fluctuation The best way to resolve this problem is to upgrade these devices to a version that support Ethernet and 200Mbps HCNA 76 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Physical Configuration If problems occur after altering the network configuration restore the original connections and try to track the problem down by implementing the new changes one step at a time Ensure that cable distances and other physical aspects of the installation that do not exceed recommendations System Integrity As a last resort verify the switch integrity with a power on reset Turn the power to the switch off and then on several times If the problem still persists and you have completed all the preceding diagnoses then contact your dealer 77 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Compliance and Safety Information FCC Radio Frequency Interference Statement This equipment has been tested and found to comply with the limits for a computing device pursuant to Part 15 subpart B of FCC class A rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generate uses and can radiate radio frequency energy and if not installed and used in accordance w
57. results for the SNR the speed rate the receive power transmitted packets and the PER 43 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 1 3 End Point Read Packet Counter Click on Count button in the line for each bridge and it appears the window which shows the MAC Address of the bridge A screen is displayed as shown in Figure 4 6 1 3 1 7 Packet Counter Mozilla Firefox Mpi 192 168 16 249 hpna device info ssp YI D X I I u TW O Figure 4 6 1 3 1 End Point Read Packet Counter Click on the Start button and the example for test result of End Point Read Packet Counter will be as below Mozilla Firefox E a http 192 168 16 249 goform ifx pna counter o lalo lialo laa CN CIC Jo CR RR RR RR RN RN RN D u M Ia nsm Q Figure 4 6 1 3 2 Output of End Point Read Packet Counter 44 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 2 Device Control Select Device Control The menu below includes the sub menus of Numbers Mode MAC Address and Spectrum for the Concentrator bridge The table also includes User List Firmware driver Upgrade Reboot and User Add for Bridges A screen is displayed as shown in SYSTEM LAN ROUTE HPNA jF Devi
58. sion SNR Rate RX power and packet counter NH 310H only Support max connecting up to 60 endpoint client Support auto speed from 32Mbps up to 200Mbps Support Endpoints Clients Rate control 512k 1M 2M 3M AM 6M 8M 10M 16M 20M 30M Support VLAN function for each Endpoint Client isolation and IEEE802 1Q Tag VLAN Support rate control of Full Speed auto Fix Speed setting 69 netsys NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 e Support auto logout user list and each endpoint isolation e Guaranteed QoS based on HomePNA3 1 Parameterized QoS e Supports SNMP v1 v2 e certified by CE and FCC VCCI Product Specification Items Descriptions Standard IEEE802 3 IEEE802 3u ITU T G 9954 standard NH 310H Interfaces 4 x RJ 45 10 100Mbps Ethernet port 1 x F type female coax connector for HCNA 1 x F type female coax connector for STB TV 1 x 12Vdc 1A power jack 1 x DB9 Console port 3105 Interfaces 2 x RJ 45 10 100Mbps Ethernet port 1 x F type female coax connector for HCNA 1 x F type female coax connector for STB TV 1 x 12Vdc 1A power jack NH 310H LED Indicators 1 x Power LED 1 x HCNA Link Activity LED 4 x Ethernet Link Activity LED 2 x Link Quality LED 70 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 1 x Power LED 1 x HCNA Link Activity LED 2 x Ethernet Link Activity LED 2 x Link Qual
59. t of Concentrator Read Packet Counter will be as below 7 Mozilla Firefox 1 httpJ 192 168 16 249 goformhtfx pna counter pu sms se eel fo lo fo fo fe fo e em fo fo la Figure 4 6 1 1 2 Output of Concentrator Read Packet Counter 41 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 4 6 1 2 End Point Net Interface Test Click on Net_Test button in the line for each bridge and it appears the window which shows the MAC Address of the bridge A screen is displayed as shown in Figure 4 6 1 2 1 In the pop up window shows WARNING All data transmission in the network will pause during the test Test Mozilla Firefox SEE http 192 168 16 249 hpna_device_info asp 00 05 6 00 10 01 START Figure 4 6 1 2 1 End Point Net Interface Test 42 netsy S NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Click on the START button wait for some time you will see the Concentrator Read Packet Counter test results such as the example of Figure 4 6 1 2 2 below Mozilla Firefox SEE http 192 168 16 249 20form fx pna netinf 00 05 6e 00 10 01 gt 00 05 6e 00 2 1 90 33 43 192Mbps 17 30 1000 1000 0 000 00 05 6 00 21 90 gt 00 05 6 00 10 01 33 43 192Mbps 16 56 1000 1000 0 000 Figure 4 6 1 2 2 Output of End Point Net Interface Test It shows the network information regarding the network test
60. than half oS ee ee ee a er eee Solution Notes 74 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Answer Each of the NH 310S can only be connected to 16 nodes Mac Address H H H H H H a a ll 4 if you forgot the NH 310H password only use the console command line to reset system to default value Please refer to the following steps for your reference Please connects NH 310H s console port to PC or laptop PC series port Launch Hyper Terminal into terminal window your Set Bits per second 115200 on the content window Set Data bits at 8 on the content window Set Parity none the content window Set Stop bits at 1 the content window Set Flow control at none the content window Power NH 310H wait some time until the login menu appears At the CLI command type the command rawaccess to reset system to default 0 At the CLI command type the command reboot to reboot the NH 310H Answer Note Default IP is 192 168 16 249 Default password is admin snefsy 5 NH 310H S HPNA3 1 EOC Managed
61. thunderstorm There may be a remote risk of electric shock from lightning DO NOT expose your device to dampness dust or corrosive liquids DO NOT use this product near water for example in a wet basement or near a swimming pool Connect ONLY suitable accessories to the device Make sure to connect the cables to the correct ports DO NOT obstruct the device ventilation slots as insufficient air flow may harm your device DO NOT place items on the device DO NOT use the device for outdoor applications directly and make sure all the connections are indoors or have waterproof protection place Be careful when unplugging the power because it may produce sparks Keep the device and all its parts and accessories out of the reach of children Clean the device using a soft and dry cloth rather than liquid or atomizers Power off the equipment before cleaning it This product is recyclable Dispose of it properly snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Table of Contents welcome 1 de cnjuerb 2 SAFETY WARNINGS RR E 3 MNS UNPACKING INFORMATION 7 EEUU 7 NaON 8 2 VFRONT PANE E A ati I LIA CE LAE ene LLL M LL 8 22 FRONT INDICATORS OE LII MI E eee 9 2 3 REAR 11 INSTAL
62. vices attached to coax wall outlets Examples of a Compression F Connector CORRECT CONNECTOR CONDITION A Stinger is right length it protrudes a bit beyond the rim Metal Fittings Coax Line Check for signs of rust or corrosion Visually check visible coax for replace if necessary nicks splits and tangling 84 5 5 NH 310H S 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 AVOID THESE BAD CONDITIONS Low dielectric a gap between the dielectric and ridge will cause packet loss dielectric should be flush with the ridge C Debris inside connector for example loose shielding strands wrapped around the stinger will cause 30dB attenuation Note We recommend use RG59 75ohm coaxial cable to establish HomePNA network 85 5 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 E 4 Install Hardware Now you are ready to install the Customer Premises Equipment Disconnect the Existing Service Find the main splitter where the service enters the house If the RG is far away from the main splitter create a splitter tree see diagram on right Remove the cable service provider s connection to the INPUT on the main splitter It is critical that no HomePNA device is connected to the INPUT on this splitter Do not put a resistive end cap on the input If you want to cap the input use only a plastic cap Make sure all other connect
63. wer adapter Apartment site survey If there was a prior MDU installation in the building check to make sure that there is no HPF connected to the splitter of the specific apartment If there is a HPF it should be disconnected before installing the bridge Note the location of the main splitter and any secondary splitters The main splitter usually connects to an outside coax cable Locate the coax connection near where the customer wants the TV for IPTV applications and or where the customer places their computer for broadband access Check for devices TVs etc connected directly to coax outlets 96 snefsy 5 NH 310H S HPNA3 1 EOC Managed Concentrator and Bridge USER S MANUAL Ver D1 Pre Install Inspection For the fastest and smoothest installation address any wiring or connector problems before starting the installation Inspect and replace damaged splitters and F connectors Check every coax connector and splitter Look for missing components damaged connectors corrosion and or other problems Replace any damaged splitters Replace damaged and low quality coax fittings crimp screw in others Inspect and replace damaged coax cables and wall plates Check every visible coax cable for cracks nicks splices and or other types of coating or shielding damage Check inside the wall plates for corrosion or poor connections or disconnections Verify that the TV service is clear prior to installing the bridge 9 9