Home
User Manual Model:TS-10B
Contents
1. ZP TRUE SOURCE User Manual Alternating Bubble Pad amp Pump System Model TS 10B A AN li C FE IPXO No AP APG UM 10B E V1 0 Copyright 2010 by TRUE SOURCE Technology Co Ltd Table of Contents 1 S alely Criteria EE A de e e Ee e fe e Tuer EE 4 Product Setup Content EIERE ebe 6 MaE En a DE 7 Power Unit Settings Content 8 Routine Maintenance and CGleammmg Ee DRE e Kee Eege e Le WE 11 Technical Specifications wrcdsccteviccssaevencsanwsacadesenndiacaenisontesesedens e E 1 Safety Criteria CE EN60601 EN60601 1 EN 60601 1 2 FCC Part 18 Class B Type BF Applied part Attention consult Accompanying documents Operating instructions C FE No AP APG IPXO Medical Device Classification Class 2 A Warnings The product is only intended to be used as an auxiliary device The manufacturer does not have the absolute responsibility and obligation to uarantee its full effects Power Unit Do not open the power unit without guidance to prevent danger Do not insert items into any opening of the power unit Do not drop the power unit Do not use the power unit in places exposed to water liquids oil smoke and flammable chemicals Use fuses as marked T1A 250V The product is contraindicated to anesthesia procedures and is only indicated for use by the user in normal conditions This the power unit is not AP APG protected Bubble Pad
2. Prevent the patient from placing his her head or neck between the bubble pad and the side rail Do not use sharp or pointed objects since this will damage the bubble pad or use high temperature objects since this may accidentally destroy the bubble pad Do not use the bubble pad in places exposed to water liquids oil smoke and 3 flammable chemicals The product is contraindicated to anesthesia procedures and is only indicated for use by users in normal conditions This the air mattress is not AP APG protected Product Functions Purpose The product is for the purpose of aiding the prevention of pressure ulcers and effective treatment of patients Pressure ulcers are commonly known as bedsores They occur when there is damage caused by pressure or shear or friction to the skin or even the underlying tissues muscles and bones Pressure ulcers are a common problem of patients suffering from long term physical immobility including those who are inflicted with spinal cord injury bedridden for a long term not clearly conscious inflicted with bladder or bowel incontinence diabetes skin fragility physical weakness or malnutrition It is an extremely complex task to treat pressure ulcers once they occur In a minor case the wounds take weeks to heal In a severe case sepsis amputation or death may occur This not only damages health but also is a burden to and waste of medical resources Using the bubble pad can aid the
3. Environment ix Storage Temperature 5 C 45 C yx Storage Humidity 10 to 80 12 Warranty The warranty period for the power unit is 12 months and the bubble pad is 6 months as of the purchase date of the product provided that the product is used in normal conditions Repair outside the warranty period is subject to charge The maintenance service for the product is warranted for 5 years Upon the completion of maintenance outside the warranty period an additional 6 month warranty period is provided During this period the same general terms and conditions of warranty apply Only function failure repair is covered during the warranty period The warranty does not include general maintenance e g replacement of the cotton filter cleaning setting adjustment or component renewal The warranty does not cover maintenance conducted by opening the power unit without authorization careless dropping or use of the product other than for its intended purpose and repair of such is subject to charge Purchase date Manufactured for en 1 1 J LJc TRUE SOURCE Technology Co Ltd 4F 523 Chung Chueng Road Hsin Tien City Taipei Hsien Taiwan Tel 886 2 8667 1780 Fax 886 2 8667 1782 http www truesource com tw air index_new asp Signatures
4. prevention of pressure ulcers and effective treatment of patients The bubble pad can be placed on the overlay of a standard medical bed The bubble pad can be alternately inflated and deflated with two rows of coupled air hoses that are connected to the power unit and activated in the Alternating Pressure Mode Theory of Alternating Pressure Mode This process allows effective arrangement in a way that a single area of the body remains in a completely pressure free and lifted state for a fixed period This allows body tissues to be temporarily relieved of pressure and blood to circulate smoothly around the tissues This in turn heals improves and prevents the occurrence of pressure ulcers Product Setup Contents 1 One the power unit 2 One the bubble pad 3 One the power cord 4 One the user manual 5 One the air hose 5 Product Features Enhanced Design Features of the Power Unit 1 For hanging the safest iron material is used for hanging hooks and its withstanding ability is far higher than plastic material 2 For shock absorption the deflation pump inside is equipped with a specially designed suspension shock absorption system and a foot mat is provided outside the unit in order to reduce the shock when the unit is in contact with the patient s bed 3 he compact size feature The system is of a compact size making it easy for placement and storage and taking into account the streamlined system appearance and practicalit
5. unit and the power cord disconnect the power unit and the hose at the feet end of the mattress 3 Put the power unit and the power cord in the box and place in a dry place 4 When the power unit is put away and not in constant use it is necessary to switch it on for 3 hours at regular intervals to lengthen its life 5 Follow the national requirement to dispose the power unit Howto store the Bubble Pad 1 Clean the bubble pad Caregivers must wear gloves and masks and protected with disinfection 2 Roll up the bubble pad and the air hose 3 Place in a dry place 10 Troubleshooting Inspection Procedure Possible Solution 1 Power unit 1 1 Check if the two ends of the 1 1 Confirm if the wall socket does not power cable are safely has power supply operate connected to the power unit and the socket 1 2 Check if the power switch 1 2 If not switch to ON on the side of the power unit is switched to ON 1 3 Check if the fuse has burnt 1 3 Turn off the power and out or not properly installed check the fuse 2 1 Check if air comes out of 2 1 If the unit operates the power unit and if the normally but no air comes connector is properly out it is possible that the connected power unit has something wrong inside and needs repair 2 Power unit is working but bubble pad is not inflating 2 2 Check if the bubble pad connector is bent or falls Off 2 3 Repair or replacement i
6. s needed if the connector is deformed and cannot be restored or the material is not in its normal state 2 3 Check if the air hose is damaged 2 4 Repair or replacement is needed if the air hose is damaged 2 4 Check if the air cotton filter is heavily soiled and the air is blocked 2 5 Replace the filter if it is heavily soiled 3 Bottom in 3 1 Check weight setting 3 1 Increase weight setting contact with the overlay 3 2 Check if air leaks from the 3 2 Replace the air cells if mattress damaged 3 3 Check if the air cotton filter 3 3 Replace the filter if it is is heavily soiled and the air heavily soiled is blocked 4 Others Problems other than the above Contact the local distributor for handling 11 Technical Specifications The Power Unit Specification E Input AC220 240V 50Hz OR AC100 120V 60Hz Power Consumption 10W max Fuse Rating T1AL 250V Weight 1 3Kg approx Dimension L26cm W8cm H13cm Air flow rate 3 8 liter min Alternating cycle time 5 6 min pre Class Type BF The Bubble Pad Specification Standard State lt gt Material 100 PVC lt gt Dimension L200cm W90cm H5cm lt Weight 2 5Kg approx lt Air Hose Length 150cm Temperature amp Humidity Limited Operating Temperature 5 C to 45 C 41 F to 113 F A Transportation Temperature 10 C to 45 C 14 F to 113 F N Transportation Humidity 5 to 95 Storage
7. s based on the user s the bottom that can t contact with the overlay The softness and hardness of the bubble pad can be selected from the number 1 to 10 to provide users comfortable Suggestion Normal setting in number 5 user weight limit 30kg to 100kg 8 Routine Maintenance and Cleaning The Power Unit 1 Avoid using the unit when the air is poor Do not smoke especially to prevent nicotine and greasy tar like substance from entering the unit and resulting in the deterioration of internal pipes and the need for frequent replacement of the air cotton filter 2 Thoroughly wipe down the dust or smear stuck on the exterior of the unit with a dry cloth and neutral detergent it is recommended to clean the pump once a week Caregivers must wear gloves and masks and protected with disinfection 3 An air purifier can also be used to maintain the air quality 4 Replacement of the air cotton filter it is recommended to replace the filter once a month Please purchase the filters from the dealer The Bubble Pad 1 With a dry cloth and neutral detergent or the 70 5 medical alcohol Caregivers must wear gloves and masks and protected with disinfection 3 To avoid the bubble pad be reused in next patient that hygienic control for the system will cause cross infection 9 Storage How to store the Power Unit 1 It is necessary to turn off the power switch in side panel unplug the power cord 2 Disconnect the power
8. y 4 Ihe cotton air filter is to be replaced outside Therefore the replacement can be done without opening the unit 5 he use of the double external fuse holders allows the unit to provide better safety protection 6 The specialized power management with an independent power cord and a master power switch on the side can better ensure safety 6 Installation Step 1 Place the bubble pad evenly on the overlay and to fix it in the overlay to turn over the front amp behind of the flat piece The end with a connector to the power unit is the feet end Step 2 Check if the securing position of the bubble pad is centered Step 3 Hang the power unit on the panel at the feet end Step 4 Connect the air hose at the feet end of the bubble pad to the air outlet of the main unit Step 5 Connector the power cord to the AC Inlet of the power unit step 6 Plug the power cord of the power unit to a socket with power supply Step 7 Turn ON the power switch on the side of the power unit and the green indicator turns on Air starts to enter the bubble pad in a few seconds step 8 Comfort Range Knob select 1 to 10 See Power Unit Settings Contents step 9 Please wait until all the air cells are inflated by at least 2 3 of their volume approx 20mmHg or for 15 minutes before the user is allowed to lie on the bubble pad 7 Power Unit Settings Contents Adjustment of the comfort range The adjustment range i
Download Pdf Manuals
Related Search
Related Contents
Gigabyte GA-MA770-ES3 motherboard Installation Manual Manual de instalación Fifth Wheel Mounting 6176M-IN001A-DE-P, VersaView Light vin «nature» rosés et clairets de bordeaux Fibre to SAS/SATA RAID Subsystem User Manual GE OBE Installation Guide Video Recording Manager - Bosch Security Systems Copyright © All rights reserved.
Failed to retrieve file