1. Fan Module 1 Fan Module 2 User Manual Ba i SAS to SAS SATA J BOD Subsystem Dual Controller JBOD Controller 1 JBOD Controller 2 a ak HE ee m OF 1 W i E i r l SS L _ i Power Supply Power Supply Fan Module 1 I Fan Module 2 1 4 3 JBOD Controller Module 1 4 3 1 JBOD Controller Panel SAS IN OUT Port RS232 Port SAS IN Port SAS IN OUT Port Mute Link LED System LED Fault LED Access LED R Link Port NOTE SAS IN OUT Port can be flexibly configured as either SAS IN PORT or SAS OUT PORT by customer s request as User Manual SAS to SAS SATA J BOD Subsystem SAS IN Port SAS cable must be connected to this port and to the SAS HBA or other Expansion Chassis s SAS Expansion Port if this chassis is connected in daisy chain SAS OUT Port SAS cable must be connected to these ports and to other SAS IN Port of other expansion chassis for daisy chaining Link LED SAS IN and SAS OUT Green indicates SAS IN OUT Port has connected or linked Access LED SAS IN and SAS OUT Blue indicates SAS IN OUT Port is being accessed RS 232 Port Used for upgrading the Firmware of JBOD controller in the Expansion Chassis Mute Use this button to silence the alarm beeper If another failure event happens the alarm beeper will sound again and this button can be pressed again to silence alarm System LED Green indicates Expansion Chassis is Powered On and
2. 26 User Manual one SAS to SAS SATA J BOD Subsystem 2 Select Transfer amp Send File You must finish within 25 seconds HyperTerminalPort 2 HyperTerminal ys Oj x apie PERE ior Send Text File cmd gt systi ti Pri Please Us Capture to Printer bcol for File Transmission Use Q Or q to quit Download before starting Modem SSSSSEP J ends a file to the remote system PA 3 Select your firmware file path and select Xmodem in the communication protocol and click transfer button E Send File Es Folder C Documents and Settings adm proSUN 6G JBOD Pat Filename C Documents and SettingsAdministrator Deskto E Browse rokocolt Send Eigse EN ees User Manual SAS to SAS SATA J BOD Subsystem 4 Wait for the transfer of file to complete LS eAypenTerminalPorh2 Hyperterminal File Edit View Eal Transres dels cmd gt system upgrade Please Use KModem Protocol for File Transmission Use Q Or q to quit Download before starting KModem SSSSSSSSSSSSSSSSSSyy_ Sending C Documents and Settings Administrator Desktop proSUN 6G JBOD F Packet 1202 Error checking Checksum Retries fo Total retries jo Last error File DOPEESECEORCESRCEERERE TASK of 245K Elapsed 00 00 37 Remaining 00 00 24 Throughput 4092 cps Connected 0 01 16 Auto detect it 15200 8 N 1 FALL CAPS NUM Sanne Print eera Zmodem file send for HyperTerminalPort 2 S
3. Port and the other end to the host bus adapter s HBA external SAS connector or to the SAS Switch The host bus adapter is installed in your Host computer system 2 3 2 Connecting to RAI D Subsystem Attach one end of the SAS cable to the SAS IN Port of the JBOD controller module and the other end to the SAS Expansion Port on the RAID controller of RAID subsystem If configured in redundant mode connect the other SAS cable to the SAS IN Port of the other JBOD controller and the other end to the SAS Expansion Port on the other RAID controller of RAID subsystem 20 User Manual SAS to SAS SATA J BOD Subsystem Chapter 3 Maintenance 3 1 Upgrading Firmware IMPORTANT Before upgrade the J BOD firmware please shut down server first or make sure no array setting on the J BOD disks The new Firmware will effective after J BOD power cycle NOTE Upgrading the firmware must be done from Master J BOD Controller J BOD Controller 1 if the J BOD Subsystem has redundant J BOD Controllers x Steps 1 Used RS 232 Port Phone jack to DB9 link ProSun SAS J BOD in command line please type system upgrade than press Enter i 3g HyperTerminalPort 2 HyperTerminal File Edit view Call Transfer Help cmd gt system upgrade Please Use KModem Protocol for File Transmission Use Q Or q to quit Download before starting KModem SSSVSSyy_ IRD auto detect 1isz00e N 1 Connected 0 00
4. Ready Fault LED Red LED is on indicates there is problem within the Expansion Chassis If LED is off the Expansion Chassis is in normal condition R Link Port Use to connect to Telnet for upgrading the Firmware of J BOD controller 1 5 Power Supply Fan Module PSFM The JBOD subsystem contains two 300W Power Supply Fan Modules All PSFMs are inserted into the rear of the chassis User Manual og SAS to SAS SATA J BOD Subsystem 1 5 1 PSFM Panel Power On Fail Indicator Power On Off Switch AC Power Input Socket The panel of the Power Supply Fan Module contains the Power On Off Switch the AC Inlet Plug and a Power On Fail Indicator showing the Power Status LED indicating ready or fail Each fan within a PSFM is powered independently of the power supply within the same PSFM So if the power supply of a PSFM fails the fan associated with that PSFM will continue to operate and cool the enclosure When the power cord connected from main power source is inserted to the AC Power Inlet the power status LED becomes RED When the switch of the PSFM is turned on the LED will turn GREEN When the Power On Fail LED is GREEN the PSFM is functioning normally l NOTE Each PSFM has one Power Supply and one Fan PSFM 1 has Power 1 and Fan 1 and PSFM 2 has Power 2 and Fan 2 When the Power Supply of a PSFM fails the PSFM need not be removed from the slot if replacement is not yet available The fan will still work a
5. SAS to SAS SATA J BOD Subsystem User Manual SAS to SAS SATA J BOD Subsystem Table of Contents Chapter 1 Introduction 0oooooeeeeeeeeesssseessssssscccccccceceeeeesssssessccecccceeeeseeeeseesssee 3 LA PEO eea E E EE A E E AE E A A 4 12 Technical 5 DS CINCH IONS eesi A E A Eaa EO eir EEEE Eae 5 13 Unpacking the JBOD SUDSYSTEIMI xs cacossesseccsciecechceszenncsdesecasnearsicatondadeainestunt aee a A rE ei 6 1 4 Identifying Parts of the JBOD SUDSYStEM ec cesessesesssesessesessssesssesessesesssseseesessseseseeseessseeeeseaee 7 il Os RONEN ON A vente centr errata ee ave tmrere Soret sere toe nen fier 7 TAZ RSM N N r E E E ore cabesssc eeetomtosees ean esessecseeeeeeuuerees 7 143 JBOD C ntroier Modula seerne en eee ne eE EE e eevee aaae 8 143 1 JBOD Controler Panels sssrin seeectecicec gecetotcetacbecicoacusescicvacsascnunstqreseecaetsercteceioeeszcegeeeee 8 1 5 Power Supply Fan Module PSFM aetna cae cease veetecet ec onebscttac ee dseacew tae atest cue naan 9 EL PORN PAINS keea E EE E E E eats 10 E LCT DEAR R E nO et error ee 11 LOL ECP Pane TED e en e E E E ee ee E eee ere 11 6 2 LCD Panel Function BUON S seisis pen e e S ode E 12 Eoo Mona DaO a eee net nee onneT a eer et rene een mt mn ea ee 13 17 Drive Camer Ys 0 aemen ete nent tee ener mene meer E eee ote ene eee ee 14 17 1 Disk Drive Status INdicatOrS sisseseade meiset eee ech ceeds 14 Chapter 2 Installation of J BOD Subsysten cccssssssecee
6. ch 2U rackmount JBOD unit It features the latest SASII 6Gb s interface and designed to fit in with the environments which needed highly reliable and relentless data growth The JBOD subsystem is also a versatile SAS2 SATA3 disk expansion system ideal for high capacity and scalability storage in IT demands Based on the 6G SAS technology the JBOD subsystem supports the choice of SAS2 and SATA3 drive configurations to deliver the best cost performance index with higher bandwidth User Manual CE SAS to SAS SATA J BOD Subsystem 1 1 Features High Density Available 24 hot swappable drive bays in a rackmount 2U chassis Support the latest 2 5 enterprise class SAS2 SATA3 disk drives High Availability Single Dual SAS JBOD controller module Each SAS JBOD controller module consist of three mini SAS 4X ports Power supply Power Supply and cooling system contained in 1 module for efficient cooling Two 300W redundant hot swappable power supplies Enclosure Incorporates a cableless design for maximum signal integrity SES Utilizes industry standard SCSI Enclosure Services to monitor enclosure and disk environmental conditions Enclosure Monitoring S E S support for standard enclosure management System LED indications Fan speed monitoring Power supply monitoring System voltage monitoring System temperature monitoring System alarm a User Manual SAS to SAS SATA J BOD Subsystem 1 2 T
7. eceeesees 15 as Wk a Fl Oee a E E E A 15 22 DIK Drive InstalatiO kesenin nee cede ner cee eee wee te renee eee oe EEEa EEEREN a 16 2 2 1 Installing a SAS Disk Drive in a DISK Tray csssssesessssssecssessessscssssecssesssseseeessesessssseeeseseees 16 2 2 2 Installing a SATA Disk Drive Dual JBOD Controller Mode in a Disk Tray 18 2 3 Connecting the JBOD SubsysteM secscschcsacsec sack cecantdectessedcuscacabdlsaleestidbenhccatedacneselisicaieiecdaccsbeannciesteels 20 2al Lonnecing tO SAS HDA scrierea E 20 23 2 Connecting to RAID SUSY STO IV accccdeciccteacatteateycsidicwscacablsedenstaeaeeucscabiotecruenndicsidtieedaecsbinexcs stvele 20 Chapter 3 Maintenance cccccccccccccccsscssssssscccccccccsccccccscssssessessssseceeees 21 s4 Upgrading FNAN oreren eE E ERE EEE 21 3 2 Replacing JBOD Subsystem COMPONENMMS cccsesessssesesesesesessssesesessesssesessesssessssesssesssesesseseeeees 25 3 2 1 Replacing JBOD Controller MOdUI cc sesesecsssesessesesesessssesesecsssssesssseseesesssessssesesesseseens 25 3 2 1 1 Replacing Controller Module with Blanking Plate sescseseeeseseeeseseeceeseees 26 3 2 2 Replacing Power Supply Fan MOU ccsesessesesesessesescsessesesessssessscsssscsnssesesesssseeeeesseseees 27 3 2 2 1 Replacing Power Supply Fan Module with Plate Cover 28 O a User Manual SAS to SAS SATA J BOD Subsystem Chapter 1 Introduction The 24 bays J BOD Subsystem The JBOD subsystem is a 19 in
8. echnical Specifications eee SS of Hot Swap Trays Twenty four 24 2 5 Small Form Factor SFF trays Disk Status I ndicator Access Fail LED Power requirements AC 90V 264V Full Range 6A 3A 47Hz 63Hz oe 10 C 40 C 50 F 104 F Temperature Physical Dimension 559 L x 483 W x 88 H mm 15 Weight Without Disk 14 Kgs Specifications are subject to change without notice User Manual 5S SAS to SAS SATA J BOD Subsystem 1 3 Unpacking the J BOD Subsystem The shipping package contains the following JBOD Subsystem Unit Two 2 power cords One 1 serial cable for single JBOD controller Two 2 serial cables for dual J BOD controllers One 1 mini SAS cable for single JBOD controller Two 2 mini SAS cables for dual J BOD controllers One 1 Ethernet LAN cable for single JBOD controller Two 2 Ethernet LAN cables for dual J BOD controllers One 1 JBOD Controller Blanking Plate Note For dual JBOD controllers One 1 PSFM Plate Cover User Manual NOTE If any damage is found contact the dealer or vendor for assistance 6 User Manual SAS to SAS SATA J BOD Subsystem 1 4 Identifying Parts of the J BOD Subsystem The illustrations below identify the various parts of the expansion chassis 1 4 1 Front View Smart LCD Panel Disk Trays Slot 1 24 Right to Left 1 4 2 Rear View Single Controller JBOD Controller Module Power Supply Power Supply
9. ending C Documents and Settings AdministratorsDesktopprnoSUN 6G JBOD F Packet 1640 Eror checking Checksum Retries fo Totalreties O Last eror File AACECECEEEEEELEEETETEEEEETEEEI 202K of 237K Elapsed 000052 Remaining 00 00 09 Throughput 3970 cpe User Manual Da SAS to SAS SATA J BOD Subsystem 5 When the transfer and firmware update is complete please power cycle the J BOD HyperTerminalPort 1 HyperTerminal File Edit view Call Transfer Help Dle 2 3 Ol cmd gt system upgrade Please Use KModem Protocol for File Transmission Use Q Or q to quit Download before starting KModem SSSEy Received 251526Bytes Buffer Download Complete cmd gt _ Connected 0 01 27 ANSIW 115200 8 N 1 FSFI E CARS NUM BaP Print Esha 6 In command line type system info you can see the Expander firmware version HyperTerminalPort1 HyperTerminal File Edit View Call Transfer Help Ole 5 3 2a Password x cmd gt system info 24 Bay system Power num 2 Expander F W V 82E Expander ID PRO_MASTER Dual Control MASTER YVendorID Prowar e Model EP 2246JD BACKUP cmd gt Connected 0 00 17 VI 100 it 15200 8 N 1 Em CAPS num Contre Print espa o 24 User Manual SAS to SAS SATA J BOD Subsystem 3 2 Replacing J BOD Subsystem Components 3 2 1 Replacing J BOD Controller Module When replacing a failed JBOD Controller Module please follo
10. nd provide necessary airflow inside the enclosure In replacing the failed PSFM refer to section 3 2 2 of this manual NOTE After replacing the Power Supply Fan Module and turning on the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the RPM becomes stable When Fan RPM is already stable the RAID controller will then power on the Power Supply This process takes more or less 30 seconds This safety measure helps prevent possible Power Supply overheating when the Fans cannot work ery User Manual SAS to SAS SATA J BOD Subsystem 1 6 LCD Display Panel 1 6 1 LCD Panel LED Power LED Power Fail LED Fan Fail LED Over Temperature LED Voltage Warning LED Reserved for RAID Subsystem n Parts Function Power LED reen indicates power is ON If one of the redundant power supply unit fails this LED will turn to RED and alarm will sound Turn RED when fan 1 or 2 fails or Fan Fail LED speed is lower than 3000 RPM Power Fail LED If system temperature is over 70 C or disk temperatures exceed Over Temperature LED 55 C the Over Temperature LED will turn RED and alarm will sound An alarm will sound if detected voltage in the controller is Voltage Warning LED g g abnormal and LED will turn RED User Manual ETEN SAS to SAS SATA J BOD Subsystem 1 6 2 LCD Panel Function Buttons Up and Down Arrow b
11. of the disk tray align with the holes of the hard drive 16 User Manual SAS to SAS SATA J BOD Subsystem 4 Install the mounting screws on the bottom part to secure the drive in the disk tray 5 Slide the tray into a slot 6 Press the lever in until you hear the latch click into place The HDD Fault LED will turn green when the subsystem is powered on and HDD is good User Manual ETZ SAS to SAS SATA J BOD Subsystem 2 2 2 Installing a SATA Disk Drive Dual J BOD Controller Mode ina Disk Tray 1 Remove an empty disk tray from the subsystem 2 Prepare the dongle board and two screws 3 Place the dongle board in the disk tray Turn the tray upside down Tighten two screws to secure the dongle board into the disk tray ers User Manual SAS to SAS SATA J BOD Subsystem 4 Place the SATA disk drive into the disk tray Slide the disk drive towards the dongle board 5 Turn the disk tray upside down To secure the disk drive into the disk tray tighten four screws on the holes of the disk tray Note in the picture below where the screws should be place in the disk try holes mre Fa W 6 Insert the disk tray into the subsystem User Manual ETE SAS to SAS SATA J BOD Subsystem 2 3 Connecting the J BOD Subsystem 2 3 1 Connecting to SAS HBA The Enclosure supports SAS interface which provides fast 600MB data transfer rate using SAS phy Attach one end of the SAS cable to the SAS IN
12. r depends on the RAID card or RAID Controller definition ry User Manual SAS to SAS SATA J BOD Subsystem Chapter 2 Installation of J BOD Subsystem 2 1 Powering On 1 Plug in the power cords into the AC Power Input Socket located at the rear of the subsystem Power On Off Switch AC Power Input Socket NOTE The subsystem is equipped with redundant full range power supplies with PFC power factor correction The system will automatically select voltage 2 Turn on each Power On Off Switch to power on the subsystem 3 The Power LED on the front panel will turn green User Manual 15 SAS to SAS SATA J BOD Subsystem 2 2 Disk Drive Installation This section describes the physical locations of the hard drives supported by the Subsystem and give instructions on installing a hard drive The subsystem Supports hot swapping allowing you to install or replace a hard drive while the subsystem is running NOTE In this model it is recommended to use 6Gb s hard drive disks 4 a 2 2 1 Installing a SAS Disk Drive in a Disk Tray NOTE These steps are the same when installing SATA disk drive in Single Controller Mode 1 Press the Tray Open button and the Disk Tray handle will flip open i 4 d d Tray Open Button 2 Pull out an empty disk tray Pull the handle outwards to remove the tray from the enclosure 3 Place the hard drive in the disk tray Make sure the holes
13. uttons Select button Exit button Use the Up or Down arrow keys to go through the information on the LCD screen This is also used to move between each menu This is used to enter the option you have selected Press this button to return to the previous menu NOTE This button can also be used to silence the alarm beeper when in main menu If you are in submenu and a failure event happens press the EXIT button few times as necessary to go back to main menu and press again to silence the alarm 42 User Manual SAS to SAS SATA J BOD Subsystem 1 6 3 Menu Diagram Model Name XXX XXX XXX XXX l ID XXXXXXXXXX F W V x x xx Temperature aa Enclosure 30 C Chip 35 C HDDO1 33 C HDD24 30 C Power Status _ Power0Ol Good Good PowerO2 Good FAN Status Fan0l1 3970 rpm Good Fan02 3970 rpm Voltage Status p LV 1 03V Good 5V_ 4 94V 3 3V 3 24V B12V_ 12 48V Alarm Status gt Disable Enable Alarm Enabled System Reset Enter Password User Manual 13 SAS to SAS SATA J BOD Subsystem 1 7 Drive Carrier Module 1 7 1 Disk Drive Status I ndicators Disk Activity Indicator ee oe ee ll BReRELE LET fT a a ae cee Status LED Activity LED This LED will blink blue when the hard drive is being accessed Disk Status Indicator Green LED indicates power is on and hard drive status is good for this slot If there is no hard drive the LED is off The fault indicato
14. w these steps Loosen the thumbscrews on the sides of the JBOD Controller Module drawer 2 Use the Controller handle to pull out the defective JBOD Controller Module drawer 3 Insert and slide the new JBOD Controller Module in Note that it may be necessary to remove the old defective JBOD Controller Module from the drawer case and install the new one recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature IMPORTANT When replacing a failed component online it is not 4 Tighten the thumbscrews on the sides of the J BOD Controller Module case User Manual 25 SAS to SAS SATA J BOD Subsystem 3 2 1 1 Replacing Controller Module with Blanking Plate When replacing a failed JBOD Controller Module with Blanking Plate please follow these steps 1 Loosen thumbscrews of the failed JBOD Controller Module drawer 2 Use the Controller Module handle to remove the failed JBOD Controller Module drawer from the subsystem 3 Insert the JBOD Controller Blanking Plate 4 Tighten the screws of the Blanking Plate When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature rr User Manual SAS to SAS SATA J BOD Subsystem 3 2 2 Replacing Power Suppl
15. y Fan Module When replacing a failed power supply fan module PSFM please follow these steps Turn off the Power On Off Switch of the failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the PSFM Use the handle to pull out the defective PSFM Before inserting the new PSFM make sure the Power On Off Switch is on Off Ui BP WU N e state 6 Insert and slide the new PSFM in until it clicks into place I MPORTANT When the subsystem is online and a Power Supply fails and the replacement Power Supply module is not yet available the failed Power Supply Module can be replaced with the Plate Cover This is to maintain proper airflow within the enclosure Refer to next section When replacing a failed component online it is not recommended to remove the failed component for a long period of time proper air flow within the enclosure might fail causing high controller disk drive temperature 7 Connect the power cord to the AC Inlet Plug of PSFM 8 Tighten the thumbscrews of the PSFM 9 Turn on the Power On Off Switch of the PSFM NOTE After replacing the Power Supply Fan Module and turning on the Power On Off Switch of the PSFM the Power Supply will not power on immediately The Fans in the PSFM will spin up until the RPM becomes stable When Fan RPM is already stable the RAID controller will then power on the Power Supply This process takes more or less 30 seconds This safet
16. y measure helps prevent possible Power Supply overheating when the Fans cannot work User Manual ee SAS to SAS SATA J BOD Subsystem 3 2 2 1 Replacing Power Supply Fan Module with Plate Cover When replacing a failed power supply fan module PSFM with Plate Cover please follow these steps Turn off the Power On Off Switch of the failed PSFM Disconnect the power cord from the AC Inlet Plug of PSFM Loosen thumbscrews of the failed PSFM Pull out the defective PSFM Insert the PSFM Plate Cover carefully Se SY rs User Manual