Home
OWNERS MANUAL
Contents
1. A AGA CERT 7795 Fully certified to AS2658 2008 COMP825 OWNERS MANUAL Es es E 4 INTRODUCTI N IT IS IMPORTANT THAT YOU READ THESE INSTRUCTIONS CAREFULLY AND UNDERSTAND THE OPERATION amp SAFETY FEATURES OF THIS APPLIANCE FAMILIARISE YOURSELF WITH THE APPLIANCE BEFORE CONNECTING IT TO THE GAS CONTAINER KEEP THESE INSTRUCTIONS SAFE FOR FUTURE REFERENCE YOUR AQUACUBE INCLUDES A y A GAS WATER HOSE 12V DC LEAD AC ADAPTOR WATER FLOW QUICK CONNECT SILICONE SHOWER CARRY REGULATOR AND PUMP AND CIGARETTE ADJUSTMENT FITTING HOSE HEAD BAG CONNECTION 1 DIGITAL CONTROL PANEL 2 WATER FLOW ADJUSTMENT 3 TAP OUTLET 4 SHOWER OUTLET 5 FLOW SWITCH INTRODUCTION 2 6 GAS REGULATOR 7 TAP OUTLET 8 UNIT POWER INLET 9 PUMP POWER OUTLET 10 WATER INLET 1 BOARD 7 OVER ela IGNITION BATTERY CUTOUT 8 0UTGOING WATER TEMPERATURE 2 BURNER OPERATING 3 INCOMING WATER TEMPERATURE 4 OPERATIONAL 9 CONTROL OUTLET 5 POWER ON OFF 10 PUMP CONTROL 6 GAS TEMPERATURE GAS CONTROL WARNINGS 2 CAUTION DO NOT Operate this appliance before reading the instruction booklet DO NOT Place articles on or against this appliance DO NOT Place chemicals or flammable materials or spray aerosols near this appliance DO NOT Operate with panels covers or guards removed from this appliance DO
2. If the appliance is not being used or is stored it must be recharged every three months to guarantee the battery life expectancy failure to do so may result in battery failure CARE GUIDELINES AND TROUBLESHOOTING DISCONNECTING FROM CYLINDER 1 Check that the appliance 1 fully extinguished the gas cylinder control valve is in the fully off position and all surfaces are cool 2 Loosen the connection to the gas cylinder in a clockwise direction TROUBLE SHOOTING This guide should be followed in case of failure of the appliance to operate correctly If symptoms persist contact Customer Service on 1300 555 197 DO NOT ATTEMPT TO REPAIR OR MODIFY THE APPLIANCE PROBLEM CAUSE Check that appliance is switched on Check sufficient water is available Check that the pump is connected to the Water will appliance not flow from Check that adequate DC power is shower head available Check DC fuse in cigarette lighter fitting Check that the shower flow water regulator is in the open position Check that gas cylinder is turned on and that there is gas in cylinder Check that the water is flowing from shower head Check that the water is not over temperature Burner will not light Check gas control Check source water temperature Cycle the water through the system back in to the source reservoir then through the appliance again Water is not hot enough sa 277 Y d lt CA
3. adaptor Attach the shower hose using the Quick Connect Fitting and ensure that the Flow Switch on the shower head is in the open position Position the gas control in the central position then depress the Pump Button water will start to flow within a few moments The electronic ignition should be heard igniting the burner when lit the Flame icon on the display will illuminate and the outlet water temperature read out will increase Taking care to measure the temperature of the water from the shower head the temperature can be adjusted by turning the gas control until the desired level 1 reached The water flow can be stopped at any time by sliding the Flow Switch to the OFF position the burner will extinguish and the pump will continue to operate To reignite the burner slide the Flow Switch to the on position and water will flow from the shower head and the burner will reignite within 5 to 10 seconds IMPORTANT Water remaining in the heat exchanger while the flow is stopped may become hot When the flow is resumed the user must check the temperature output to ensure that it 1 suitable and not too hot Once the user has finished with the appliance slide the Flow Switch to the OFF position and depress the PUMP button to stop the flow of water to the appliance OPERATING INSTRUCTIONS Step 1 Press t
4. free from direct sunlight heat and ignition sources being stored indoors ensure that the location complies with the standard AS NZS1596 This appliance must only be serviced by an authorised service agent return to your place of purchase for service amp repair DANGER This appliance is designed for outdoor use only Do not use the appliance if t has a leak worn deteriorated or damaged seals Handle with care even after brief use always pick up using the handle not the cylinder It may be hazardous to attempt to fit other types of gas containers or cartridges Use only in well ventilated areas This appliance shall only be used in an above ground open air situation with natural ventilation without stagnant areas where gas leakage and products of combustion are rapidly dispersed by wind natural convection Do not use adaptors or modify appliance to fit other connectors or cylinders When using this appliance children must be supervised by an adult at all times Never leave appliance unattended when operating Do not use as a cooking appliance or modify for any other reason CARBON MONOXIDE HAZARD A This appliance produces carbon monoxide which has no odour Using the appliance in enclosed spaces for example caravan car boat or mobile home could cause DEATH 2 WARNINGS OUTDOOR USE ONLY The appliance must be used outdoors only and 1 to be operated no closer than 800mm fr
5. NOT Operate in an enclosed area without ventilation DO NOT Operate in a boat caravan or tent IMPORTANT This appliance 1 designed to be used with a source water temperature of 20 or below The maximum temperature lift from the appliance is 25 to 30 C from the source water temperature For safety the appliance is designed to shut off the burner when the water temperature from either of the outlets reaches 50 The average run time for the appliance from a fully charged battery is 20 to 30mins before it will require recharging The appliance can be operated whilst connected to AC or DC however the battery will only receive charge when pump is not operating When the pump is off the battery will receive charge THIS APPLIANCE IS NOT INTENDED FOR THE SUPPLY OF DRINKING WATER THIS APPLIANCE IS INTENDED FOR THE SUPPLY OF HEATED WATER FOR THE PURPOSE OF WASHING AND CLEANING ONLY CHECK AND CONFIRM SAFE WATER TEMPERATURE BEFORE USING THIS APPLIANCE WATER FROM THIS APPLIANCE MAY BE VERY HOT GENERAL WARNINGS This appliance shall only be used with the regulator supplied with the appliance and must only be connected to non refillable 468g disposable Cartridges certified to DOT 39 UN1075 This appliance 1 to be stored in a dry amp well ventilated location free from direct sunlight Do not store when still connected to the cylinder Make sure that the cylinder 1 disconnected and 1 stored in a well ventilated area
6. RE INSTRUCTIONS Using warm soapy water with a mild detergent wipe down all surfaces and areas of the appliance taking care not to allow water to enter the burner outlets DO NOT submerge the appliance in a sink or bowl DO NOT use abrasive cleaners or bleach SPECIFICATIONS Water flow 3 litres per minute Average Inlet voltage 12V DC 5A 42 x 262 x 434mm Weight 8 5kg ERROR CODES The appliance is fitted with a number of operational amp safety features that can be identified by the following error codes in the event that the unit will not operate No Burner not lit E6 Over Temp Shut Off E7 Outlet Water Temp Exceed 48 C E8 Tilt Switch Activated IGNITION INLET TEMP OUTLET WATER TEMP NOTES cOoOmPanionTa Companion 1 distributed by Primus Australia Pty Ltd Bundoora Victoria 3083 www companionleisure com au
7. e from obstructions and closure AIR INLET IMPORTANT This appliance is designed to be used with a source water temperature of 20 or below if the temperature of the outlet water exceeds 45 50 the burners will shut off and will only relight once the outlet water temperature falls below 45 C This appliance 1 designed to raise the outlet water temperature by a maximum average of 25 above the source water temperature and can be adjusted by the gas control In the event that the temperature lift is insufficient simply run water through the appliance once returning the heated water to the source water reservoir Run again through the appliance until the desired temperature is reached SAFETY FEATURES SAFETY FEATURES This appliance is equipped with the following safety features e Over Temperature Sensor the appliance will not allow the burner to remain in operation once the outlet water temperature reaches 45 50 the burner will automatically relight once the outlet temperature falls below 45 e Water Flow Sensor water must be flowing through the system to allow the burner to ignite In the case that the water supply is restricted or ceases le the Flow Switch is in the off position the burner will be extinguished and will not relight until the water flow recommences e Tilt Switch in the event that the appliance is moved during operation or is being operated on an unstab
8. he power button and the unit will switch on automatically selects the shower outlet depress the OUTLET button and the tap icon will illuminate Step 2 Check the Battery Indicator that sufficient power is available if not connect to the AC or DC adaptor Step 3 Swing the tap away from its storage position and locate towards the side of the appliance and locate a basin or bucket beneath and locate the water flow to the central position Step 4 Position the gas control in the Max position then press the Pump button water will start to flow within a few moments Step 5 The electronic ignition should be heard igniting the burner when lit the Flame icon on the display will illuminate and the outlet water temperature read out will increase Step 6 The water temperature can be adjusted by moving the flow valve between Min amp Max as this will slow or increase the water flow resulting in an increase or decrease in the outlet temperature IGNITION BATTERY CUT OUT INLET TEMP OUTLET WATER TEMP IGNITION BATTERY CUT OUT Doc Ak ogc rit 00 INLET TEMP OUTLET WATER TEMP e 2 STORING YOUR AQUACUBE STORING THE APPLIANCE Step 1 Press the Power button amp turn the appliance off Step 2 Disconnect all hoses and hold vertically allowing all excess water to drain from them With the shower head check that the flow regulatio
9. k if gas remains in the cylinder disconnect from the appliance and hold the cylinder in a vertical position then shake from side to side If there is a sound or a feel of liquid movement inside the cylinder the cylinder contains gas When changing gas cylinders ensure this 15 conducted outside in a well ventilated location free from people animals ignition sources such as naked flames pilot lights electrical equipment with heaters or elements Y SAFETY INSTRUCTIONS lt SAFETY INSTRUCTIONS This appliance must only be used in an above ground open air situation with natural ventilation without stagnant areas where gas leakage is rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used should comply with one of the following A enclosure with walls on all sides but with no overhead cover B Within a partial enclosure that includes an overhead cover and no more than two walls C Within a partial enclosure that includes an overhead cover and more than two walls the following must apply 1 At least 25 of the total wall area is completely open 2 30 or more in total of the remaining wall side back and front wall areas 15 open and unrestricted 3 In the case of balconies 20 or more of the total wall area must remain open and unrestricted Important During operation ensure that all air inlets amp exhausts are kept fre
10. le or non solid surface the appliance will shut down and must be switched off until a suitable surface is located y s Y SETTING UP INSTRUCTIONS SETTING UP Step 1 Remove all components from the storage bag and place the appliance on a solid non combustible surface and straighten out all hoses to remove any kinks or twists Step 2 Check that the power switch is OFF then connect the pump assembly to the water inlet and the power lead to the outlet marked PUMP Step 3 Attach the gas cartridge to the regulator by rotating in a clockwise direction then attach the regulator to the Aquacube Check for gas leaks with soapy water Do not use a flame If a leak is detected remove the gas cartridge amp retighten all connections then retest Step 4 Submerge the pump a suitable reservoir of water DO NOT use water direct from rivers lakes or the ocean DO NOT use salt water with this appliance Open Flow regulation switch Ensure Gas control 15 4 in central 27 position IGNITION SHOWER OPERATING INSTRUCTIONS OPERATING THE SHOWER Step 1 Step 2 Step 3 Step 4 Step 5 Step 6 Step 7 Step 8 Press the Power Button and the unit will switch on and automatically selects the shower outlet Check the Battery Indicator to see if sufficient power is available if not connect to the or DC
11. n switch is in the ON position Step 3 Return the tap to its locked position if being used Step 4 Unscrew the regulator assembly from the appliance amp remove the gas cartridge Step 5 Tip the appliance towards the back and to one side to drain excess water from the heat exchanger via the water inlet POWER AND CHARGING 2 APPLIANCE POWER 8 CHARGING Step 1 The appliance 15 fitted with 12V 2 5A hr battery pack and can be recharged from either the AC or DC adaptors supplied Step 2 To recharge the appliance from either AC or DC the unit must be switched on and the Battery Indicator illuminated Step 3 Connect to the power inlet socket at the rear of the appliance and the Battery Indicator will start to flash and move from Red to Green confirming that the battery 15 now charging IGNITION BATTERY CUTOUT Step 4 AC Connect the three 3 pin plug to a suitable outlet then connect to the appliance amp switch on the AC outlet Step 5 DC Connect the adaptor to the appliance and then connect to a suitable outlet via the cigarette lighter fitting INLET TEMP DO NOT USE AC to DC converters modify the adaptors supplied with the appliance Charge time from either power source is 4 hours 50 battery capacity can be reached after 2 hours however to maintain battery life amp condition it is recommended that the unit is allowed to charge for the full 4 hours IMPORTANT
12. om the sides and 800mm from above all combustible surfaces fabrics and flammable materials Must only be used on solid amp stable horizontal surfaces made from non combustible or non flammable materials and should be protected from direct drafts and ina well ventilated place Caution Accessible parts may be very hot Keep young children away Avoid twisting amp kinking the Propane gas hose If you smell gas immediately turn the gas off at the cylinder and move the appliance amp cylinder to a well ventilated area outside keeping well away from sources of heat such as naked flames amp pilot lights Do not attempt to move or relocate the appliance when it 1 operating Extinguish the burner amp allow to cool disengage the gas cylinder then move the appliance CHECKING FOR GAS LEAKS Check that all connections are tight and that the gas cylinder connection has been tightened before you turn the cylinder gas valve on NEVER check for leaks with a flame or pilot light Using soapy water coat all connections If bubbles appear turn the cylinder gas control off and retighten the connection before re testing Inspect the appliance regularly for signs of wear leaks or incorrect operation If symptoms such as flaring of the burners issues with lighting damages to hoses or connections or leaks from seals or gas controls are identified do not attempt to repair contact Customer Service 1 555 197 chec