1. message it will show your accumulation memory The user will not be able to save the same load value twice The load will have to be lifted twice not just saved twice on the same lift Therefore the user will only see SAVE displayed once on the screen per each lift Operation Display Function CLEAR Confirms deletion of accumulation value Operation Display Function Holds the weight press again to HOLD D a M ry 3 Voltage Displa Display Function MR F1 Display current battery voltage Power Off Display Function OFF Displays current battery voltage and powers off 14 Adelaide A NOBLE amp SON LTD World Class Lifting Solutions 08 8260 6688 Also includes Electronics Division Whyalla Roxby Downs Port Lincoln Melbourne Sydney Newcastle Darwin Brisbane Rockhampton Perth Karratha Port Hedland 08 8645 0322 08 8671 2080 08 8683 3955 03 9706 9333 02 9748 1166 02 4953 7966 08 8947 4884 0732779222 0 4922 6636 08 9272 5666 08 9185 2244 08 9140 1333 For detailed information and specifications Nobles extensive range of lifting and rigging equipment and electronic load cells and load weighing systems visit us at www nobles com au 100 Australian Owned amp Operated
2. RIG MATE Electronic Crane Scale USER GUIDE A NOBLE amp SON LTD www nobles com au WORLD RECOGNISED ACCREDITATION IMPORTANT Thank you for choosing a Nobles RIG MATE crane scale To ensure a long and trouble free service life please read this manual carefully before operation TABLE OF CONTENTS SAC eene nn a A A 3 Product 3 Schematic 2 Dimensions amp WelghtS oooocccccccccccccccccccccnncnnnnnnnnn 4 Operation Guide mne 4 Care in USe se essen esee nnns 6 Display UNCON Seen en dias o tarea teni sori 6 o AAA 7 Remote Control 7 SAFETY GUIDE Please read the following instructions and advice before using the RIG MATE crane scale Overloading is strictly prohibited Continued and prolonged loading will decrease the accuracy and shorten the life of the Crane Scale Check the shackle and hook prior to use to ensure there are no signs of overloading such as deformation cracks or excessive corrosion Check the battery voltage and re charge the battery as required Only use the recharger supplied with the unit Do not disassemble the unit or try and repair it if a fault occurs return the unit to A Noble amp Son Ltd for repair PRODUCT FEATU
3. RES 30mm LCD display Manual or Remote Operation Easy to replace lead acid battery and AC to DC power adaptor recharger 6V 10Ah rechargeable battery included Infrared remote controller with operating distance of 20m Display Functions Load weight hold tare accumulation conversion gross net conversion PRODUCT SPECIFICATIONS 2 000 kg 1 kg Display Increments 5 000 kg 2 kg 10 000 kg 5 kg 100 Max Capacity 125 Max Capacity 400 Max Capacity 60 hours Minimum Operation Time 100 hours Maximum depends on operation mode Battery Type Fully Sealed lead acid battery 6V 10Ah DC9V 1500mA Operating Temperature 10 C 40 C Operating Humidity lt 85 RH under 20 C Batteries in Remote Control AA Batteries 1 5V x 2 SCHEMATIC DIAGRAM Control Key Remote Control Load cell gt Amplifier ES A D Ep Display DIMENSIONS amp WEIGHTS F TRRMCS02000 TRRMCS05000 TRRMCS10000 44 kg OPERATION GUIDE Turning ON Press the button OFF ON Display will read Flashes Maximum capacity is displayed Current battery voltage is displayed Waits for stable signal Green Steady light is illuminated The unit is now ready for operation Zeroing 0 shows after turning the scale on You can also press the 0 button on the remote control Tareing After hanging any rigging on the scale press the Press ons
4. cale IA TARE button to TARE subtract the weight bs of the rigging from Press on controller the overall load 5 LJ The red tare light will illuminate Battery Checking The voltage Press on scale should be higher OFF ON than 5 8V Press pa on controller _MR Fi Press CI Load Weight Holding After the reading is stable press the HOLD button A square indicator dot will appear in the top left hand corner of the display Press hold again to resume the reading Low Power Warning When the battery voltage is lower than 5 8V the display will flash The scale will continue to work until the Lb is displayed which is followed by an automatic power off 1 minute afterwards Battery recharging is then required Overload Warning The oL is displayed when the load tare net exceeds the rated dn L la capacity of the scale The scale SHOULD NOT be overloaded as O this could cause damage to the scale and increase the possibility of the scale failing Power Saving The is displayed when the weight load on the scale has not changed for a 15 minute period The load display resumes when the weight load changes The scale will also automatically power off when the weight load on the scale has not changed for 60 minutes Battery Recharging 1 Turn off the scale Connect the adaptor to 220 240V AC power supply and attach its connector into the socket at the rear of the scale When the in
5. dicator turns from green to red charging is completed Recharging time should not exceed 8 hours but the scale is fitted with over charging protection so excessive charging will not damage the battery 2 Ifthe scale needs to work non stop a spare battery pack may be required to facilitate immediate battery changing and minimise charging down time Turning OFF Battery voltage is Press Ojon scale for 3 seconds LU b J O displayed OFF ON Press the controller for 3 seconds Is displayed for 2 seconds before power off CARE IN USE 10 Never overload the crane scale Do not lift loads over people Do not stand or walk under a lifted load Do not try to swivel the load with the standard crane scale hook and shackle If a load is required to swivel then an approved swivel must be incorporated in the rigging system or the standard eye hook must be replaced with an approved swivel hook Always ensure the scale is loaded evenly and in line through the top shackle to the bottom hook if loading is not in line this will place excessive forces on the S type load cell and could result in a dangerous situation For optimum performance and to ensure a long service life the scale should be treated with care When not is use the scale should be hung in a dry and well ventilated area Do not leave the scale on the floor for extended periods of time The scale should be cleaned periodically to stop the built up of dust and oth
6. emote distance functioning correctly Remote not functioning Remote batteries are flat REMOTE CONTROL OPERATIONS Zero SOLUTION Check the battery Connect the battery Re charge the battery Check and or clean ON OFF button Check and or clean Zero button Check the recharger and the plug Stabilise the load Check or replace the load cell Keep the scale in a dry environment Wait 3 5 minutes after power on Scale should be suspended by top shackle Replace the battery Check or replace the recharger Check and or clean the receiver Replace the AA batteries in the remote Display Function Set 0 when no load is on the scale 12 Operations Display Function Red TARE light illuminates press again TARE to show gross weight load If these two buttons are pushed in order MR M from left to right you will enter your accumulation data Clears your memory in other words all your past accumulations will be deleted CLEAR after pressing these two buttons in order This is your scroll button when you are inside the accumulation data memory By continuing to press TARE it will eventually scroll to the total accumulation value This is your memory button When pressed it will memorise the current load on your Rig mate crane scale By pressing this button in normal mode you will cause your Rig mate crane scale display to show SHIFT on screen If you press after that
7. er contaminants Do not use the scale in the rain the scale is designed primarily for indoor use and will not tolerate excessive rain or moisture Even loading will ensure accurate readings avoid shock loading of the scale Scale waiting for stable signal E cr ID Accumulation weight does not exceed minimum capacity Accumulation exceeds 30 times Accumulation exceeds 99999 r l3 Accumulation is repeated multiple accumulation will not function Confirms accumulation clearance ima CL r Cancel accumulation deletion B BH Confirm accumulation deletion No accumulation 5 H FE Switch to different mode Battery voltage SC L E Calibration SEEUP Parameter setting 1 d d Battery adjustment Other display modes are Overload Low Power Warning Power Saving Mode and Power Off as described in OPERATION GUIDE 11 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE PROBLEM No display on power up Battery is not connected Display flashes Low battery power Cannot turn on or off ON OFF button damaged Recharger indicator does Defective recharger or not come on recharger not connected Load is in motion Overload or defective Unstable display load cell Scale is damp Load cell not yet ready to The display does not work show zero when there is no load Load is not placed correctly Defective battery Cannot recharge Defective recharger or connector Remote receiver not Short r