Home

User Guide E7000 Series Cable & Antenna Analyzer

image

Contents

1. Counter Resolution Frequency Span Range Sweep and Trigger 56 1 Hz 0 Hz zero span 1kHz to 3000 MHz E7000 Series Cable amp Antenna Analyzer User Guide 1mSec to 250 sec span gt 200 Hz Bandwidth Ratio Range 20 uSec to 500 sec span 0 Hz Accuracy lt 0 2 Trigger Type free run single video TV Resolution Bandwidths Range 10Hz to 3 MHz in 1 3 10 sequence Bandwidth Accuracy lt 10 Selectivity 60 dB 3 dB en Video Bandwidths Range 10 Hz to 1 MHz in 1 3 10 sequence Stability lt 105dBc Hz 100 kHz offset from CW signal Phase Noise lt 90 dBc Hz 10 kHz offset from CW signal lt 85 dBc Hz 1 kHz offset from CW signal Amplitude Specifications Measurement Range displayed average noise level to maximum safe input level Input Attenuator Range 0 dB to 50 dB Step 5dB Internal Preamplifier Frequency Range 1 MHz to 3000 MHz Gain 15 dB Noise Figure 4 dB Max Safe Input 30dBm peak power input attenuation gt 15 dB 100 VDC Displayed Average Noise Level Input Terminated 0 dB Attenuator RBW 10Hz VBW 10Hz Sample Detector preamplifier OFF typical preamplifier ON typical lt 142 dBm 1MHz 1GHz lt 138 dBm 1GHz 3GHz lt 155 dBm 1MHz 1GHz lt 151 dBm 1GHz 3GHz Spurious Responses Second Harmonic lt 70dBc for 20 dBm signal at inpu
2. DISP Style Press this submenu to enter the display style submenu and set the display style Four display styles modern salubrious high contrast and night 1 Modern The style is default style of the system 2 Salubrious The basic background is white in order to save ink when are printing graphics and improve efficiency 3 High Contrast The display style of the instrument increases displays contrast and the level of the display for more clearly for observing in outdoor environment 4 Night The style of the instrument will be used to display all the red lines in order to overcome the problems by the light at night testing Optimization of the night viewing Color Press this menu to set the color about the measure datas The users can set options Data Trace 1 Data Trace 2 Mem Trace 1 Mem Trace 2 Limit Line Reset Color text and grid The users can also set the color of the color setup and reset operation The main function is to enable users to improve the eye fatigue they can select right color according to their own feelings The color format is RGB565 Range of red and blue component values from 0 to 31 green component values range from 0 to 63 The users can press ENTER to switch the color components The selected color components displayed in capital letters others lowercase letters By the rotary knob or arrow keys to change the color component values The step is 1 by the rotary knob but the step o
3. connectors are properly situated in the case top opening You may find it easier to insert the connectors first then pull the corners over the bottom of the E7000 2 E7000 Series Cable amp Antenna Analyzer User Guide Instrument Overview This chapter provides a brief overview of the E7000 Series Cable amp Antenna Analyzer The intent of this chapter is to acquaint the user with the instrument For detailed measurement information refer to a specific measurement guide listed in Measurement Guides This chapter provides information about the following items Turning On the instrument Front Panel Overview Test Panel Connector Overview Display Overview Symbols and Indicators Data Entry Mode Selector Menu E7000 Series Cable amp Antenna Analyzer User Guide 2 1 Turning On the instrument The Deviser E7000 E7100 models are capable of approximately 4 5 hours and the E7000SA E7100SA models are capable of approximately 3 hours of continuous operation from a fully charged field replaceable battery The E7000 Series can also be operated from a 12 Vdc source which will also simultaneously charge the battery This can be achieved with either the AC DC Adapter or Automotive Cigarette Lighter Adapter Both items are included with the instrument CAUTION When using the Vehicle charger Make sure that the supply is rated for a minimum of 60 Watts at 12 VDC and the socket is clean without any dirt or debris If the adap
4. Clock Clock This key brings up a submenu for setting the current system date and time Use the keypad the Up Down arrow Geng keys or the rotary amp knob to select the date and time Network This key brings up a submenu for setting the Beeper network communication information including IP address subnet mask and gateway Enter the IP address through the Display gt number keys and the decimal point key press the ENTER key to complete the setup For example Press keys as follows More pe oe 2 L LST LST LLL a ENTER At this time the IP address is 192 168 0 22 le Beeper This key brings up a submenu for setting the beep status There are two beep types Expert Mode on REE Beep CAUT For the completion of some specific actions 771 the system will issue a short beep to prompt the users The Power Save e users can set this beep status by submenu in order to meet their needs Beep Alarm For setting some illegal value the system will issue a alarm beep to prompt the users The users can set 43 E7000 Series Cable amp Antenna Analyzer User Guide 44 this beep status by submenu in order to meet their needs Display See the display setup menu Confirm This key brings up a submenu to confirm some important operations to prevent pressing the wrong button by the users Press this submenu key to go to the next level Confirm submenu The skilled users can tu
5. E7100 0030 GPS receiver Including antenna Table 1 2 Available Options 1 4 Standard Accessories NP DLO1 NJ 150 2 5m N male N female type RF cable P 110829NJK L29 female N male Adapter Table 1 3 Standard Accessories E7000 Series Cable amp Antenna Analyzer User Guide 1 5 Preventive Maintenance E7000 series preventive maintenance include the unit surface cleaning RF connectors and all accessories cleaning Clean unit surface with a soft lint free cloth dampened with water NOTICE To avoid damaging the display or case do not use solvents or abrasive cleaners Clear the RF connectors and center pins with a cotton swab dampened with denatured alcohol The fingers of the N f connectors and the pins of the N m connectors should be unbroken and uniform in appearance If you are unsure whether the connectors are undamaged gauge the connectors to confirm that the dimensions are correct The test port cable should be uniform in appearance and not stretched kinked dented or broken 1 6 Calibration Requirements amp Annual Verification Local service centers are responsible for instrument maintenance and calibration once a year To ensure performance conformity Deviser recommends a periodical maintenance and calibration The Cable amp Antenna Analyzer is calibrated with OPEN SHORT LOAD calibration components It is especially important to verify the OSL calibration components periodically to ensure performance c
6. Table 1 2 20 E7000 Series Cable amp Antenna Analyzer User Guide DEVISER Cal Status FullSpan ON Data Points 259 Start Stop Freq 25 MHz 4 4 GHz Distance Max 7 78m Cable Name NONE velocity 0 880 Cable Loss 0 079dB m Start Om Cable amp Antenna L AW Stop 4 5m 2011 08 04 15 21 Mode Spectrum gt Analyzer Transmissnb Power Meter PT SC tical L Figure 2 5 Measurement Mode Selection 21 E7000 Series Cable amp Antenna Analyzer User Guide 3 Quick Start Guide 3 1 Introduction This chapter provides a brief overview of the E7000 s basic measurement setup 3 2 Cable amp Antenna Analyzer mode Set the instrument to Cable amp Antenna Analyzer mode as described in the previous section gt Select the Measurement Type Press the MEAS main menu key and select the appropriate measurement Shown in Figure 3 1 DE VISER Cable amp Antenna IS Measure Cal Status KI 1 99m 2 3108 USUR FullSpan ON d Data Points DIF USUR 259 Start Stop Freq 25 MHz Cable Loss 4 4 GH2 Distance Max 7 78m Cable Name fj DUAL e Con pe Velocity Active DISP 0 880 Liss not Cable Loss l l 0 079dB m 1 ful More gt Start Om Stop 4 5m 2011 08 04 15 21 Figure 3 1 Select the Measurement Type 22 gt gt E7000 Series C
7. activate the system menu The overall structure of the system menu as follows System A Test B Update Cc Help D Print E Printer SYS Setup Display OK a Start Switch SYS Test gt A Panel Cancel Quick Start Output Page Up wae a Config Sys Update gt B gt E Page Down Printer Help Kl C INU Image ES Print gt D Preset Return Return Return Return Figure 5 1 System Menu Overview 40 E7000 Series Cable amp Antenna Analyzer User Guide Setup A Langue B Clock C Network D Beeper E Setup G Confin H Powersae E DateFormat Beep CAUT s Preset Language Year IP Address Confirn G 155 kend ES Ee GPS Test Expert Mode Reset Color Kack ra ES tot Month Subnet Hask nM Kaz EN ER w DD Beep Alarm Power Saveh Delete File Clock gt gt B Day Gateway H An DD HH VY oj wr aas on LEE Netuork C Hour a 2n Beep Alarn Beeper gt D Minute 5m Format b Display F OFF Hore gt Return Return Return Return Return Return Return Return Figure 5 2 System Menu Overview Display A DIS Stye B Color D Color C Menu Hold DISP Style A Hodern Data Trace1 Background 3s Color gt B Data Trace2 Text 5s Menu Hold gt High Hem Trace1 Grid 18s Se lt contrast e
8. araa naenin iare aee EEren EDA ATE AIRSET RERA 40 5 2 System Menu Overview sssssee esse esse eee sese sees sees ennenen ennenen 40 KE ET 42 5 4 System Options Men 43 55 Display Setup MENU aiea er aA E aE 45 5 6 System Test Menu TTT 47 5 7 System Upgrade Menu 48 58 Help MEn eis e a a E aE i 5 9 A id EE 5 10 Select Printer Menu 6 Software Tool HT 53 6 1 Toto l nr a a a i 53 PZ Feature OVervi W iiion e Aa E A E e EA 53 6 3 Install Site Workbench sananne E E AE 54 6 4 Connecting to the Instrument sss ee ee eee eee eee ee eee 54 KE EE 55 7 1 Cable amp Antenna Analyzer 7 2 Spectrum ANALYZER EE E7000 Series Cable amp Antenna Analyzer User Guide 1 General Information This chapter provides information about the following items Introduction Available Models Available Options Standard Accessories Preventive Maintenance Calibration Requirements amp Annual Verification ESD Caution Battery Replacement Soft Carrying Case Technical Support and Service Information E7000 Series Cable amp Antenna Analyzer User Guide 1 1 Introduction E7000 Series Cable amp Antenna Analyzer with integrated spectrum analyzer reduces per site maintenance expense maximizes system up time and breaks away from the traditional fix after failure maintenance mode by finding small problems before major failures occur E7000 Series performs various RF measurements aimed at simplifying cable feedline and antenna analysis Retur
9. file name already exists the system will prompt whether to overwrite the original file File Save Measurement Save Setup Press this submenu key to save the measurement file in the equipment The saved measurement can be named by using ave the numeric keys Measurement Save Image Save Image Press this submenu key to save the bitmap file in the equipment The saved bitmap file can be named by using Recall gt the numeric keys Recall G Press this submenu key to display the Recall menu This menu is for recalling the setup files the measurement files Delete or the image files from internal memory Copy Press this menu to enter the copy menu Press this submenu key to display the copy menu This submenu is for copying files from internal memory or a USB flash drive Delete Press this submenu key to display the Delete menu This submenu is for deleting the setup files the measurement files or the image files from internal memory 35 E7000 Series Cable amp Antenna Analyzer User Guide 4 5 Recall Menu Key Sequence FILE gt Recall Sort By Press this submenu key to sort file by the file name or by the date that the file was saved Sort Order Displays the file in ascending or descending order based on the selection in the Sort By key File Type Press this submenu key to select what type of file is viewed The option are Setup Measurement or Image The Recall file typ
10. immunity 77700 0 Corrected directivity 20 dBm gt 1 0 MHz from carrier freguency lt 42dB after standard calibration lt 38dB after full band calibration Return loss Range 0 00 60 00dB Resolution 0 01dB VSWR Range 1 65 Resolution 0 01 Cable loss Range 0 00 30 00dB Resolution 0 01dB DTF Return loss range 0 00 60dB 55 E7000 Series Cable amp Antenna Analyzer User Guide VSWR range 1 65 Length 0 to data points 1 spanx2 x Vp x C Span frequency range Resolution m Vp x C spanx2 Data points 130 259 517 2065 RF output port Nf type Impedance 500 Display 6 5 TFT LCD 640 480 1 USB2 0 1 mini USB Interface 1 10M 100M LAN port Storage space 1GB memory gt 2000 trace files Operation temperature 10 55 C Store temperature 20 80 C Weight 2 2kg Size LxWxH mm 258 x 173 x74 Power supply Battery 11 1V 5 2AH Continuous Work Time gt 4 5 hours Typ gt 8 hours AC adapter output 15 19VDC AC adapter input 100 240VAC 50 60Hz Language English Chinese 7 2 Spectrum Analyzer Frequency Specifications Frequency Range 100 kHz to 3000 MHz Frequency Reference Aging 1 ppm per year Stability 1ppm Temperature Stability 2 ppm 0 to 502C Marker Count Accuracy S N 25 dB RBW span 0 01 Accuracy 2 ppm 1 count
11. 6 Calibration Requirements amp Annual Verification sssssssssseseserereeeneeee 4 1 7 ESfttGautton e si ces ack d nd nana z das dv anno onde AA 4 1 8 Battery Replacement acreana n steve E A S 5 T9 Soft Carrying e EE 6 2 Instrument OvervieW ssssssssesssessssssscesssssssecccssssseocssssssseoesssssseeesssess 7 2 1 Turning On the Instrument 2 2 Front Panel Overview 2 3 Test Panel Connector Overview D ei a 2 4 Display OVEMleW ie tiit esate tintin A 2 5 Menu Operation ai eenaa ae aa e Ee AREA AAEE aR 2 6 Symbols and Indicators raza dva n n ERN E Data UE 2 8 Mode Selector Menu 3 QUICK Start Guidea siississcieedisesseesssesbessesesssssesssssssessssssdssstesssessassstesess 22 SCH Ipntrodetlog deeg eis 22 3 2 Cable amp Antenna Analyzer mode sese ener 22 3 3 Spectrum Anal 1 Pin e ear entices 26 4 File TTT eskkkEEEKEEKEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEEE EEN 31 ALT uge ele d EE 31 4 27 Managing Fil S x5555 54 4 cre civten cosseesssde cer deeg 32 4 3 File Menu Overview sse eee eee 34 d Ele VBR eee er eee E O Ep pe 35 4 5 REGall MENU iis sce sceessss5icessecacee ed dees i saveecesaaasiaseani ege ee 36 Clg le TEE 37 4 7 Delete Menu dee a aa E E 38 E7000 Series Cable amp Antenna Analyzer User Guide AB FIGS TY PO ais icc ieee eS E ea Se ee 39 5 System Operations ccccccceceeeeeceeecececeeeeecceeceeeeeeecccesseccccceeceeeeeeeeees 40 5 1 Introd ctioN iseen aeina e
12. MAR main menu key 2 Press the More submenu key 3 Press the Counter Mkr submenu key to open or close the frequency counter gt Single Limit Line 1 Press the LIMIT menu key to display the Limit menu 2 Press the Sngl Limit submenu key to display the Limit Type menu Press the submenu key to select limit type 3 Press the engl Value submenu key and use the arrow keys rotary or the keypad to change the single value 4 Press the Limit Test submenu key to open or close auto test function gt CAL 1 Press the CAU main menu key to display the Calibration menu 2 Press the Cal Amp submenu key to set calibration amplitude 3 Press the Amp Corr submenu key to retain calibration amplitude data 4 Press the submenu key to retain frequency response data 30 E7000 Series Cable amp Antenna Analyzer User Guide 4 File Management 4 1 Introduction This chapter will review the file management features of the E7000 and detail the FILE menu The instrument has functions which can antomatic storage patameters Each turn on the instrument which will automatically recover the pre shutdown state therefore it simplifies the setting work The users also can set the instrument state by saving or recalling the configuration files The configuration file contains the measurement mode of the instrument frequency dista
13. Sequence FILE gt Recall gt File Type Measurement FILE gt Copy gt File Type Measurement FILE gt Delete gt File Type Measurement Setup The configuration file contains the measurement mode of the instrument frequency distance marker and File Type other parameters and calibration data In this way when as the users need to set these information at next time they can call the saved configuration file from the instrument in order to avoid the repeat calibration steps and improve HZ SSR aan work efficiency Meas The measurement files contain all of the besen information in the current field and the measurement data Image The measurement window is saved as a picture for easy viewing and management 39 E7000 Series Cable amp Antenna Analyzer User Guide 5 System Operations 5 1 Introduction This chapter will review the E7000 system operations which the main including system configuration service functions and other operations such as language and clock setup network setup system testing system information system upgrade and so on System menu has six options which are system setup system testing system upgrades help print and restore factory setup When the users select a function option it will activate a sub menu to set the parameters or select the functions 5 2 System Menu Overview To access the functions under the system menu press the key which will
14. User Guide E7000 Series Cable amp Antenna Analyzer Model E7000A E7000A SA E7100A E7100A SA Cable amp Antenna 4 4GHz 4 4GHz 6 1GHz 6 1GHz Spectrum 3GHz 3GHz Transmission 3GHz 3GHz WEVISER Ver 1 08 E7000 Series Cable amp Antenna Analyzer User Guide Conventions This manual has the following conventions for presenting information WARNING A warning alerts you to any condition that could cause personal injury CAUTION A caution alerts you to any condition that could cause a mechanical failure or potential loss of data Make sure the AC power supply voltage meet the equipment requirements otherwise it will cause a equipment failure Make sure to plug the power cable into an electrical outlet that has a safety grounding before turning on the power switch Touch the internal circuit may cause a mechanical failure or personnel injury so only trained engineer can remove the instrument cover and maintain the instrument Guarantee This instrument is guaranteed for a period of 12 months from the date of shipment Under warranty any fault not caused by improper use will be repaired for free Liability of the user Use this instrument according to this instruction manual When this instrument need to be repaired please send it back to our company or our appointed repair center The guarantee is limited only to the instrument and does not involve any damage of equipment personnel and property caused by improp
15. able amp Antenna Analyzer User Guide Set the Frequency Press the FREQ DIST main menu key Press the Start Freq submenu key and use the keypad rotary knob or the arrow keys to enter the start frequency Press the Stop Freq submenu key and use the keypad rotary knob or the arrow keys to enter the stop frequency Set the Amplitude Press the AMPTD main menu key Press the submenu key and use the keypad rotary knob or the arrow keys to edit the top scale value Press Enter to set Press the Bottom submenu key and use the keypad rotary knob or the arrow keys to edit the bottom scale value Press Enter to set Set the amplitude in Auto Scale mode In Auto Scale mode the measurement trace can be displayed on the middle of the display area by setting the top and bottom value of the scale automatically 1 Press AMPTD key to enter the Amplitude menu Press Auto Scale key Turn on Markers Press the MARK main menu key Press the Marker 1 Marker 2 submenu key switch on or off the markers and move the markers Press the More Marker submenu key to enter the next submenu and switch on or off the Marker 3 Marker 4 Marker b Marker 6 Use the arrow keys or the rotary knob to move the marker You can also enter the freguency or distance value o
16. ain menu key to display the Amplitude menu Set Amplitude Reference Level and Scale 1 Press the Ref Level submenu key and use the arrow keys rotary or the keypad to change the reference level Press ENTER to set the reference level value 2 Press the Sacle Div submenu key and use the arrow keys rorary knob or the keypad to enter the desired scale Press ENTER to set the scale value Set the Marker 1 Press the MARK main menu key to display the Marker menu 2 Press the Marker 1 Marker 2 submenu key to open or close the marker Dress the More Marken submenu key to display next submenu which can press the Marker 3 Marker 4 Marker 5 Marker 6 submenu key to open or close the marker 3 Use the rorary knob to place the marker on the desired freguency also use the keypad to enter the marker value Set the Delta Marker 1 Press the MARK main menu key to display the Marker menu 2 Press the More submenu key 3 Press the Delta submenu key to open or close the delta marker Set the Noise Marker 1 Press the MARK main menu key to display the Marker menu 2 Press the More submenu key 3 Press the Mkr Noise submenu key to open or close the noise marker E7000 Series Cable amp Antenna Analyzer User Guide Set the Marker Table 1 Press the MARK main menu key to display the Ma
17. e Print correct printer model Output This option is used to set the print output type you can switch between color and Black amp White When the printer only supports color printing capabilities this color Output feature is effective on La Start Config Printer Click this menu to enter the Select Config Printer screen The equipment supports four major EE manufacturers and hundreds of printers INU Image INV Image on or The menu function is which set anti color graphics switch You can make the measure background input character grid the measure curve datas and the limit line This method is order to save ink when be printing graphics and improve efficiency 51 E7000 Series Cable amp Antenna Analyzer User Guide 5 10 Select Printer Menu Key Sequence gt Print gt Config Printer Printer Switch Page Up Page Down Return 52 Switch Press this submenu to switch between vendors and device Using the rotary knob or arrow keys to select a specific manufacturer and printer model Enter key can also perform the same function Page Up Making the vendor or device page up the list Page Down Making the vendor or device page down the list Return Put the marker on the printer model and then press Return to save the printer model information E7000 Series Cable amp Antenna Analyzer User Guide 6 Software Tool 6 1 Introduction This chapter provide
18. e can be changed with the software keys Sort By Mane pate 1 The setup files contain the measurement mode of the instrument freguency distance marker and other Sort Order parameters and calibration data Eese 2 The measurement files contain all of the information File Type in the current field and the measurement data 3 The measurement window is saved as a picture for Read easy viewing and management Read Read the files which was saved in the memory Different treatment depend on the file type 1 Load the setup file which was saved in the memory 2 Put the measure file into memory in order to achieve comparative analysis and data computation 3 Preview the image file which was saved in the memory 36 E7000 Series Cable amp Antenna Analyzer User Guide 4 6 Copy Menu Key Sequence FILE gt Copy Copy Sort By Sort Order File Type Select All Trans To USB DISK Import From USB DISK anes vat C a mi Sort By Press this submenu key to sort file by name by the date that the file was saved Sort Order Display the file in ascending or descending order based on the selection in the Sort By key File Type Press this submenu key to select what type of file is viewed The option are Setup Measurement or Image The file type can be changed with the software keys Select All Press this submenu key to select all files that was displayed in the screen which
19. easure ment modes not available in Spectrum Analyzer or Power Meter modes HOLD When in the Hold mode this key starts the E7000 sweeping and provides a Single Sweep Mode trigger when in the Continuous mode it pauses the sweep When in the Hold mode the hold symbol appears on the display ESC Exits the present operation or clears the status window If a parameter is being set pressing this key will clear the value currently being entered and restore the last valid entry Pressing this key again will close the parameter ENTER Press this key to finalize data input or select a highlighted item from a list pis 0 E7000 Series Cable amp Antenna Analyzer User Guide Measurement Function Keys Measurement function keys are active when the instrument is not in parameter edit mode Press this key to set sweep type points RF immunity RBW data averaging and data smoothing etc TRACE Manipulating the trace menu enables you to find the difference between the active trace and a saved trace or to do data math etc LIMIT Display the limit line menu for the current operating mode when in cable and antenna analyzer or spectrum analyzer mode SAVE STP Save the current system setup to an internal memory location When the key is pressed a Setup File Name appears Use the numeric keys to enter characters for the setup file name and press the ENTER key to implement RECALL STP Recall a previously saved setup from a memory
20. entry The secondary function of the number keypad is to list various menus or to implement various measurements LED Indicators Charging LED is located on the test panel the LED is red when the battery is charging and is green when the battery is fully charged The Power LED is located to the right of the On Off key the LED is green when the unit is on N E7000 Series Cable amp Antenna Analyzer User Guide 2 3 Test Panel Connector Overview The connectors and indicators located on the test panel Figure 2 2 are listed and described below USB Mini B Type LAN port TEE D Se External USB A Type DC Out RF Output RF Input Power Supply Figure2 2 E7000 Test Panel Connector External Power The external power connector is used to power the unit and for battery charging Input is 12 5 VDC to 19 VDC at up to 3 42A USB Interface Type A The E7000 has a Type A USB connectors that accept USB Flash Memory devices for storing measurements setup data and screen images or a GPS modual USB Interface Mini B The USB 2 0 Mini B connector can be used to connect to a PC LAN port The LAN port is used to connect to a PC loaded the Site Workbench software providing a simple and easy way to manage archive analyze print measurement reports customize your cable list antenna list signal standards list 13 E7000 Series Cable amp Antenna Analyzer User Guide RF In 50 Type N fema
21. er use of the instrument E7000 Series Cable amp Antenna Analyzer User Guide Limitation of Guarentee The warranty is not applicable for the faults resulted by improper use or inadequate maintenance including software or interface and unauthorized open of the instrument Within the 12 months warranty period calibration maintenance service and consultation shall be free After the 12 months warranty period fees for material and repair workman will be charged appropriately The following items are not under warranty A Damage caused by improper voltage input B Deformation or damage of panel switches devices and case as well as defects involving interval parts caused by external mechanical force shocking and dropping etc C Defects caused by unauthorized repair D Defects caused by the instrument worked beyond the required technology specification Updates Updates if any can be downloaded from the Deviser web site at http www devisertek com Deviser Part No DK11820E7000 Tianjin Deviser Electronics Instrument Co Ltd All rights reserved Printed in CHINA May 2012 CE E7000 Series Cable amp Antenna Analyzer User Guide Table of Contents 1 General Information EEN 1 1 1 uge ie e TR 2 1 2 Available Models sinansa a p E aieas 2 T3 Available aeie ETT 3 1 4 Standard AcCeSSOrieS 0 2 0es ssseesceeveceseanies aY 92 TTRa 929 R 25T ATTE 3 1 5 Preventive Maintenance srasni sole A 4 1
22. f the arrow keys is 5 45 E7000 Series Cable amp Antenna Analyzer User Guide If you need to restore the initial factory state color scheme press Reset Color submenu to complete Menu Hold By this option the users can set to keep time for the menu on the screen There are five options 3 seconds 5 seconds 10 seconds 30 seconds and always Select always state after the menu has been displayed on the screen When no other options selected key operating time than the set time automatically hidden menu to get a larger display measurement area Title Label Press this submenu to set the title text Through the number keys to enter the title name only support space numeral and letter The characters up to a maximum of 8 Press ENTER key to complete Title text displayed on the screen above the title bar 46 E7000 Series Cable amp Antenna Analyzer User Guide 5 6 System Test Menu Key Sequence gt SYS Test Display This menu function is that the color of the screen will turn Test all white all black all red all green and all blue which can detect the existence of the dead pixels Display Panel Panel Press the submenu button to enter the test screenwhich displays the panel buttons The users clicks the corresponding button on the panel at the same time the button on the interface will respond Exit the test screen if press continuously the key twice 47 E7000 Series Cable amp Ante
23. f the marker via the numeric keys directly Delta Markers are available for each of the six reference markers For the 23 E7000 Series Cable amp Antenna Analyzer User Guide selected marker Toggle the Delta On Off submenu key to turn on the Delta marker gt Auto Markers When making Return Loss and VSWR measurements the Peak Valley Auto feature can be used to automatically turn on Marker 1 to peak Marker 2 to valley and display M1 and M2 in the Marker Table When making DTF measurements the Auto feature can be used to automatically turn on Marker 1 to Maximum Peak Marker 2 to next Peak Marker 6 to Minimum Peak 1 Press the MARK main menu key 2 Press Auto Search key gt Single Limit Line 1 Press LIMIT to enter the Limit menu 2 Press the Limit Test key to turn on the Limit 3 Press the Sngl Limit key to choose the type of the Limit 4 Press the Sngl Value key and then use the numeric keypad the arrow keys or the rotary knob to change the limit value and then press Enter gt DTF Setup In Distance To Fault DTF mode the length of the transmission line distance and cable type are selected The cable type determines the velocity propagation and cable attenuation factor The following procedure can be used to set the distance and select the appropriate cable type NOTE Selecting the correct cable is ver
24. is order to convenient to copy Press ENTER key to select or deselect the file to be copied Trans to USB Disk Transfer the files selected in the top window to the root directory of U disk Import from USB Disk According to the current file type import the corresponding files from the root directory of U disk 37 E7000 Series Cable amp Antenna Analyzer User Guide 4 7 Delete Menu Key Sequence FILE gt Delete Sort By Press this submenu key to sort file by name by the date that the file was saved Sort Order Display the file in ascending or descending order based on the selection in the Sort By key Delete File Type Press this submenu key to select what type of ASLEN file is viewed The option are Setup Measurement or Name Date gt Image The file type can be changed with the software Sort Order keys sel pess Select All Press this submenu key to select all files that File Type was displayed in the screen which is order to convenient setup to copy Press ENTER key to select or deselect the file to be copied Select ATI Delete Press this submenu key to delete the seleted files Delete NOTICE When the submenu Delete File option in the submenu Confirm menu is turned on press this submenu to activate the next level submenu the users reguire to confirm whether to delete the files 38 E7000 Series Cable amp Antenna Analyzer User Guide 4 8 Files type Key
25. le connector Maximum input is 30 dBm at 50 VDC RF Out Reflection In RF output 50 2 impedance for reflection measurements Maximum input is 25 dBm at 50VDC 14 E7000 Series Cable amp Antenna Analyzer User Guide 2 4 Display Overview Figure 2 3 describes Antenna measurement mode DTF the return loss measurement type at some of the important information nO N a 2 gZ o DEVISER Tne Cable amp An i S m l G Z BN cal status CDMA China 1 A 4 gege o s o a FAIL 3 Dafa Points Cable Loss stop Dist a z 6 196 dB m 2 8 Start StopFreq MIN 6 dB n 1 ae 889 MHz MAX 5 dB m Units 3 915 MHz er Jm 5 Distance Max 3 A Windowing gt 3 Mornar Zz M1 Cable Name Z c Velocity M2 m3 Na M5 j Velocity Start Om Stop 30m ES 0 840 RefDist Ref Ampl Delta Dist Delta Ampl 2 135m 101 i Cable Loss 3 Fim 1 00 are 4 21 15m 1 00 iia 0 196dB m 5 25 59m 1 00 able gt 6 7 26m 2 25 Parameter Frequency Test Result Measurement Setting standard Indicatoin Type Trace Title Mode eS Icon USB Battery Charge X Do you want to replace file N39 07 57 E117 07 71 2011 01 01 06 27 Marker Table Note information GPS Location Date Time Figure 2 3 Cable amp Antenna Analyzer DTF VSWR Measurement Display 15 E7000 Series Cable amp Antenna Analyzer User Guide 2 5 Menu Operation There are 7 typical men
26. location When the key is pressed a Setup File selection box appears on the display Select a setup using the Up Down arrow key and press the ENTER key to implement SAVE MEAS Save displayed traces to memory When the key is pressed the Measurement File Name appears Use the numeric keys to enter characters for the measurement file name and press the ENTER key to save the trace RECALL MEAS Recall a previously saved trace from memory When the key is pressed a Measurement File selection box appears on the display Select a trace using the Up Down arrow key and press the ENTER key to implement 11 E7000 Series Cable amp Antenna Analyzer User Guide VSWR Implement the VSWR measurement RETURN LOSS Implement the RETURN LOSS measurement CABLE LOSS Implement the CABLE LOSS measurements DTF VSWR Implement the DTF VSWR measurement DTF RL Implement the DTF Return Loss measurement M P Arrow Keys The arrow keys can often be used to change a value or to change a selection from a list This function is similar to the function of the rotary knob The arrow keys are also used to move markers Rotary Knob Turning the rotary knob changes numerical values scrolls through selectable items from a list and moves markers Values or items may be within a dialog box or an edit window Pressing the Rotary Knob is used as ENTER key Number Keypad The Number keypad has two functions The primary function is number
27. m Night Hen Trace2 30s Limit Line Reset Color Return Hore Ki gt D Return Return Figure 5 3 System Menu Overview 41 E7000 Series Cable amp Antenna Analyzer User Guide 5 3 System Menu Key Sequence System S S Setup SYS Test SYS Update Help Print Preset 42 SYS SYS Setup Press this submenu key to go to the next level Setup submenu See 5 4 SYS Test Press this submenu key to go to the next level Test submenu see 5 5 SYS Update Press this submenu key to go to the next level Update submenu see 5 6 Help Press this submenu key to go to the next level Help submenu see 5 7 Print Press this submenu key to go to the next level Print submenu see 5 8 Preset Press this submenu key which the system will run an initialization program and restore the factory setting state E7000 Series Cable amp Antenna Analyzer User Guide 5 4 System Options Menu Key Sequence gt SYS Setup Language This submenu key brings up a selection submenu allowing selection from a menu of built in languages for the Setup E7000 displays The languages currently available are English and Chinese Language GPS This submenu key shows and sets the GPS status If o you do not receive the GPS location information it is Con EEE displayed three gray horizontal line Please make sure the GPS antenna access to an eguipment and the outdoor antenna does not block other objects
28. n Loss SWR Cable Loss Distance to Fault DTF 1 port phase and smith chart The E7000 is an integrated multi functional analyzer that eliminates the need to carry and learn multi instrument The E7000 is a cable amp antenna analyzer that can be configured to include 3 GHz spectrum analyzer 2 port Transmission Measurement with a bias tee and a High Accuracy GPS receiver for location stamping The bright 6 5 inch color display provides visibility even in broad daylight Built in Li lon battery can work more than 4 5 hours Even with spectrum analysis option the working time is still more than 3 hours The internal 1G flash memory is large enough to store approximately 2 000 traces or setup files Measurements data and setup files can also be stored in a USB flash disk or transferred to PC via the LAN cable Site Workbench a PC based software program provides a simple and easy way to manage archive analyze and print measurement reports customize your cable list antenna list and signal standards list 1 2 Available Models Table1 1 lists the E7000 models and frequency ranges described in this User Guide E7000A E7000A SA E7100A E7100A SA Cable amp Antenna 4 4GHz 4 4GHz 6 1GHz 6 1GHz spectrumAnalyer LL som som Table 1 1 Available Models E7000 Series Cable amp Antenna Analyzer User Guide 1 3 Available Options E7000 E7100 Description E7000 0010 E7100 0010 Transmission Measurement E7000 0030
29. nalyzer mode X Calibration status OFF The E7000 has not been calibrated Xx Calibration status Full Span ON The E7000 has been calibrated with discrete Open Short and Load components This is a Full Span calibration indicating it is possible to change the frequency range and trace points after calibration 3x Calibration status Standard ON The E7000 has been calibrated with discrete Open Short and Load components This is a Standard calibration indicating it is possible to change trace points but it is impossible to change the frequency range after calibration without performing another calibration Battery Symbols x i Green Battery is 30 to 100 charged x Yellow Battery is 10 to 30 charged te MMB Red Battery 0 to 10 charged Ww LE Lightning Bolt Battery is being charged When either the AC DC Adapter or the 12 VDC adapter is connected the battery automatically receives a charge and the battery symbol with the lightning bolt is displayed Caution Use only use batteries adapters and chargers provided with this instrument 18 E7000 Series Cable amp Antenna Analyzer User Guide When operating from external power without a battery installed the battery symbol is replaced by a plug body as shown in Figure 2 4 F Figure 2 4 Battery Not Installed Other Symbols x CG Network Connection The instrument is communicating with PC via the LAN port x USB connection The usb device is busy f
30. nce marker and other parameters and calibration data In this way when the users need to set these information at next time they can recall the saved configuration file from the instrument in order to avoid the repeat calibration steps and improve work efficiency The function of the measure files stored is order to watch and manage the measurement results by the users The function of the measure files stored into the memory is order to achieve a compatative analysis and data calculation The PC management software can download the measurement files so that detailed analysis management and generate report The instrument supports other functions save the bitmap pictures preview information import the U disk and so on The measurement window is saved as a picture for easy viewing and management 31 E7000 Series Cable amp Antenna Analyzer User Guide 4 2 Managing Files File Manage DEVISER Image File KH Copy Name Size SaveTime Select sort By Mane Date 600 05 KB 2000 01 01 03 21 600 05 KB 2000 01 01 03 21 Sort Order 600 05 KB 2000 01 01 05 03 600 05 KB 2000 01 01 03 26 600 05 KB 2000 01 01 03 27 File Type Select All Trans To USB DISK Import From USB DISK Return 7 files Figure 4 1 File Manage 32 E7000 Series Cable amp Antenna Analyzer User Guide File Type File Type Suffix File Type Suffix Mea
31. nna Analyzer User Guide 5 7 System Upgrade Menu Key Sequence gt SYS Update The upgrade folder exists in the root directory of U disk U disk insert into the equipment USB port press the menu to enter the upgrade submenu then choose whether to upgrade Press the OK sub menu to upgrade Lower left of the screen prompts to upgrade then do not pull out the U disk wait until you are prompted to complete After the upgrade is complete you need to restart the equipment When the software needs to upgrade the users can ask the latest program by the electronic letter 48 E7000 Series Cable amp Antenna Analyzer User Guide 5 8 Help Menu Key Sequence gt Help Press the submenu About key to display the informations of the equipment system including the equipment name OS version information software version information DSP Version information serial number Cable amp Antenna frequency range battery capacity the system current temperature and storage details DEVISER About a Help E7100A Cable amp Antenna Analyzer OS Version 2 6 33 rc42 0 Software Version 1 1 2 Quick Start DSP Version 1 0 1 Guide Serial Number Cable Antenna Freq Range 25MHz 6100MHz Battery 100 12 49 Battery Run Time to Empty Temperature 54 C 129 2 F Total Free Space 256 0 MB 210 5 MB Return 2011 08 01 14 41 Figure 5 4 System Menu Overview 49 E7000 Series Cable amp Antenna Anal
32. onformity 1 7 ESD Caution E7000 series like other high performance instruments is susceptible to electrostatic discharge ESD damage Coaxial cables and antennas often build up a static charge which may damage the E7000 input circuitry E7000 operators must be aware of the potential for ESD damage and take all necessary precautions It is recommended to discharge the static by connecting a short or load device to the cable or antenna before connecting them to E7000 It is important to remember that the operator may also carry a static charge that can cause damage Following the practices outlined in the above standards will ensure a safe environment for both personnel and equipment E7000 Series Cable amp Antenna Analyzer User Guide 1 8 Battery Replacement The battery can be replaced without the use of any tool The battery compartment is located on lower side of rear when you are facing the measurement display Wring out two screws slide the cover down and remove the battery Installation is the opposite of removal NOTE When inserting the battery the battery label should face the back of the instrument and the guide slot on the battery should be below the contacts If the battery door does not latch ed the battery may be inserted incorrectly Figure1 1 Battery Compartment Door NOTE Use only batteries adapters and chargers provided with this instrument CAUTION When using the Vehicle charger Make
33. op frequency Enter the Center Frequency 1 Press the FREQ DIST main menu key 2 Press the Center Freq submenu key 3 Enter the desired center freguency using the keypad the arrow keys or the rotary knob When entering a freguency using the keypad the submenu key labels change to GHz MHz kHz and Hz Press the appropriate unit key Pressing the ENTERI key has the same affect as pressing the MHz submenu key The center freguency and span is shown at the bottom of the screen Select a Signal Standard 1 Press the FREO DIST main menu key 2 Press the Signal Standard submenu key 3 Press the Select Standard submenu key The Signal Standards dialog box opens 4 Highlight a signal standard and press ENTERI to select 5 Press the Channel submenu key to change the channel value in the Channel Editor The signal standard is shown in white at the top of the screen Set the Measurement Frequency Bandwidth 1 Press the SWEEP main menu key 2 Press the Bandwidth submenu key to display the BW menu Press the RBW and or the VBW submenu key to manually change the values Set RBW and VBW automatically by pressing the Auto RBW submenu key or the Auto VBW submenu key 3 Press the RBW VBW submenu key to change the resolution 27 E7000 Series Cable amp Antenna Analyzer User Guide 28 bandwidth and video bandwidth ratio Set the Amplitude Press the AMPTD m
34. or data exchange x Hold The measurement pauses and the trace is not refreshed 19 E7000 Series Cable amp Antenna Analyzer User Guide 2 7 Data Entry Parameter Setting You can set parameters with the numeric keys the arrow keys and the rotary knob It is simple to change the parameters quickly with the arrow keys You can change the parameter continuously with the rotary knob Edit in position displayed On a measurement display Many parameters are listed in place You can move the highlight cursor at the place where a parameter shows and press the Enter key to begin setting The numeric keys arrow keys and the rotary knob can be used to set the parameter Press Enter to exit Submenu Entry When pressing the corresponding submenu key Parameter shows on the upper left corner of the display You can set the parameter using the numeric keys arrow keys or the rotary knob and press Enter to exit the editor Text Entry When saving a Measurement a Setup or a BMP file you have to enter the characters and numbers to name it 2 8 Mode Selector Menu Press the MODE hard key to enter the measurement mode selection display Figure 2 5 You can select the desired measurement mode or enter the next level menu You can also press the shortcut measurement function keys at the bottom of the keypad to implement the measurement NOTICE The measurement mode depends on the E7000 model and installed options Refered to Table 1 1 and
35. parameter edit mode otherwise measurement function keys are active Note Keep the fan inlet and exhaust ports clear of obstructions at all times for proper ventilation and cooling of the instrument Main Menu Keys Five main menu keys are below the display screen Press the key then select a measurement mode by pressing the corresponding sub menu key NOTE Available mode selections will vary according to model number and options installed FREQ DIST Displays the Frequency or Distance to Fault soft key menus depending on the measurement mode AMPTD Displays the amplitude soft key menu for the current operating mode MEAS Displays the measurement soft key menus for the current operating mode Displays the marker soft key menus for the current operating mode E7000 Series Cable amp Antenna Analyzer User Guide Sub Menu Keys There are eight keys that change function depending upon the current mode selection The current key function is indicated in the soft key menu area on the right side of the screen Main Function Keys There are six main function keys on the top of the panel FILE Active the file management function to use for saving or recalling the setup files measurement files and graphics files SYS Allow selection of system and application setup parameters the display language system upgrade and printing etc CAL Starts the calibration in SWR Return Loss Cable Loss or DTF m
36. rker menu 2 Press the More submenu key 3 Press the Mkr Table submenu key to display or close the marker table Set Peak Function of the Marker 1 Press the MARK main menu key 2 Press the More Peak Options submenu key to display the Peak menu 3 Press the Peak Search submenu key to search the maximum value of the amplitude and display the freguency 4 Press the Next Peak Left submenu key to search the next maximum value of the amplitude from the current place 5 Press the Next Peak Right kubmenu key to search the next maximum value of the amplitude from the current place 6 Press the Peak Track kubmenu key to auto search the maximum value of the amplitude after every sweep 7 Press the Morel submenu to display the next menu 8 Press the Peak Peak submenu to display the frequency difference and amplitude difference of the maximum and minimum amplitude at the current sweep Press the submenu to display the frequency and amplitude of the minimum amplitude at the current sweep 10 Press the Threshold submenu key and use the arrow keys rotary or the keypad to change the threshold value so Set Frequency Counter The function of frequency count is which can be accurate Hz to the frequency of the maximum amplitude about the current sweep equivalent to frequency counter 29 E7000 Series Cable amp Antenna Analyzer User Guide 1 Press the
37. rn off this feature to improve the operating speed Press F1 to enter the confirmation setup menu There are three confirmation setups described as follows Preset To restore the factory setup required for the user to confirm Reset Color To reset colors required for the user to confirm Delete File To delete files required for the user to confirm Expert Mode To facilitate the professional test you can turn off the expert mode completely in the daily basic test The expert mode can be activated some menus of the unique features in an equipment For example In expert mode the system setup in the display menu increases the three functions namely grid on off Prompt on off and Sweep Lines on off The menu is used for professional use with the current test case in order to achieve the purpose of convenience test Power Save This key brings up a submenu for setting the power saving mode which a total of six options 15 seconds 30 seconds 1 minute 2 minutes 5 minutes and turn off Select Off the screen s backlight will remain light When no other options be selected key operating time is greater than the setting time the equipment will automatically dim the backlight brightness to save battery power E7000 Series Cable amp Antenna Analyzer User Guide 5 5 Display Setup Menu Display DISP Style Color Title Label m Menu Hold gt always Key Sequence gt SYS Setup gt Display
38. rt to RF Out and press the ENTER key Connect load to RF Out and press the ENTER key Verify that the calibration has been properly performed by checking that the calibration status message at the top left of the display area is displaying Standard ON or FullSpan Cal ON 25 E7000 Series Cable amp Antenna Analyzer User Guide 3 3 Spectrum Analyzer SSet the instrument to Spectrum Analyzer mode as press MODE key and then choose Spectrum Analyzer gt Measurement Style Press MEAS key to display the measurement style shown in Figure 3 2 DEVISER Spectrum Analyzer CE Measure REF Offset 0 0 dB occ BW D Attenuation 10 dB Ch Power gt Pre Amp OFF a ACPR L RBW 3 MHz VBW 1MHz Sweep Time 60 ms Detection k Measurement Posi Peak OFF AVG Count OFF i Center 1 5 GHz Span 3 GHz 2011 10 09 12 37 Figure 3 2 Measurement Style Set Start and Stop Frequencies 1 Press the FREQ DIST main menu key 2 Press the submenu key 3 Enter the desired start frequency using the keypad the arrow keys or the rotary knob When entering a frequency using the keypad the submenu key labels change to GHz MHz kHz and Hz Press the appropriate unit key Pressing the key has the same affect as pressing the MHz submenu key 4 Press the Stop Freg submenu key 26 E7000 Series Cable amp Antenna Analyzer User Guide 5 Enter the desired st
39. s a brief overview of Site Workbench For detailed information refer to the Site WorkBench Manual The Deviser Site WorkBench Software Tools is a Microsoft Windows 2000 Windows XP and Windows 7 compatible program for transferring and editing saved measurements markers and limit lines to a PC The Site Workbench Software Tools will not function on earlier versions of the Microsoft Windows operating system 6 2 Feature Overview gt Display and Analyze Traces The management software can recall files which saved by the measurement equipments It can also display the measurement traces and analyze the measurement data The main features are changing the trace of the scale displaying Marker editing and limit line editing gt Context Menu The context menus are accessed by right clicking the mouse on an active measurement screen in the graphic display editor window lts mainly functions include some common features image editing of the current window gt Editor Features Provide the cable editor the signal standard editor and other commonly used editor You can upload and download data from the equipment gt Remote Control Software When PC management software connect to the equipment properly which can control the equipment through the relevant procedures The purpose is to reach the remote control 53 E7000 Series Cable amp Antenna Analyzer User Guide gt Superimposed Trace This feature allows multiple
40. sure that the supply is rated for a minimum of 60 Watts at 12 VDC and the socket is clean without any dirt or debris If the adapter plug becomes hot to the touch during charging Please discontinue use immediately NOTE Deviser recommends removing the battery for long term storage of the instrument E7000 Series Cable amp Antenna Analyzer User Guide 1 9 Soft Carrying Case The E7000 can be operated while in the soft carrying case On the back of the case is a large storage pouch for accessories and power supply Figure1 2 Instrument Inserted into the Soft Carrying Case To install the instrument into the soft carrying case 1 The front panel of the case is secured with hook and loop fasteners Fully close the front panel of the case When closed the front panel supports the shape of the case while you are inserting the E7000 2 Place the soft carrying case face down on a stable surface with the front panel fully closed and laying flat NOTE The soft case has two zippers near the back The zipper closer to the front of the case opens to install and remove the instrument The zipper closer to the back of the case opens an adjustable support panel that can be used to provide support for improved stability and air flow while the instrument is in the case This support panel also contains the storage pouch 3 Open the zippered back of the case 4 Insert the instrument face down into the case take care that the
41. surement files SWR Measurement files DHA VSWR Phase Measurement files RTL Measurement files SMI Return loss Smith Chart Measurement files CBL Setup file STP Cable Loss Measurement files DVS Graphics files BMP DTF VSWR Measurement files DRL DTF Return Loss File Name The file name can only be based on letters numbers and spaces Use the numeric keys to input the file name The file name set up Max to 12 characters 33 E7000 Series Cable amp Antenna Analyzer User Guide 4 3 File Menu Overview Open this menu by pressing the key the overall structure of the File menu File A Recall B Copy C Delete D File Type Save Sort By Sort By Sort By setup pel rr lr size Save Sort Order Sort Order Sort Order Measurement Measurenent Delen D lpes Dit Save File Type File Type File Type Image ee ac Recall gt A Read ge See Trans To Copy gt B ege Delete perete gt oC a Return Return Return Return Figure 4 2 File Menu Overview 34 E7000 Series Cable amp Antenna Analyzer User Guide 4 4 File Menu Key Sequence FILE Save Setup This key will save the current setup with a user defined file name The file name is changed using the numeric keys which only be based on letters numbers and spaces then press ENTER to save this file If you input the
42. t mixer TOI gt 15dBm two 20 dBm signals at input mixer 57 E7000 Series Cable amp Antenna Analyzer User Guide with gt 1 MHz separation and att 0 Residual Responses Input Terminated and lt 85 dBm 1 MHz to 3000 MHz 0 dB Attenuator Display Range Log Scale 0 1 to 1 dB div in 0 1 dB step 1 to 40 dB div in 1 dB step Linear Scale 10 divisions Scale Units dBm dBmV dBuV mV Marker Readout 0 03 dB for log scale Resolution 0 03 of ref level for linear scale Traces 3 traces Trace Detector sample posi peak neg peak normal average Marker E n tions peak next peak marker to center marker to ref etc Marker Display normal delta fix marker amp frequency counter Reference Level 130 dBm to 30 dBm Level Accuracy lt 1dB 259C typical Inputs Outputs RF INPUT Input N connector Input Impedance 500 VSWR lt 1 8 typical 58 E7000 Series Cable amp Antenna Analyzer User Guide Tianjin Deviser Electronics Instrument Co Ltd Add No 8 Haitai Chuangxin 3 Road Hi Tech Industrial Development Area Tianjin China 300392 Tel 86 22 2768 2088 Fax 86 22 2764 5002 Http www devisertek com E mail overseasbiz deviser com cn 59
43. ter plug becomes hot to the touch during charging Please discontinue use immediately Ca row esc ewen Main Function z Keys Sub Menu Fan J Keys Exhaust i Port 7 Fan Inlet Port d Numeric Keypad Measurement lo function Keys o DEVISER E7000 Cable amp Antenna Analyzer Main Menu Keys Backlight Control On Off Button Figure 2 1 E7000 Overview To turn on the instrument press the red On Off button for 2s on the front panel Figure2 1 The instrument takes approximately twenty seconds to complete power warm up and to load the application software At the completion of this process the instrument is ready for use E7000 Series Cable amp Antenna Analyzer User Guide 2 2 Front Panel Overview The E7000 Series menu driven interface is easy to use and requires little training The E7000 uses the keypad for data input The five main menu keys below the screen and eight submenu keys on the right side are menu keys Function keys on the right consist of six main function keys and twelve measurement function keys The twelve measurement function keys are dual purpose depending upon the current mode of operation The dual purpose keys are labeled with a number on the key itself and the alternate function is printed in black below each of the keys Numeric keys are active in
44. traces compared 6 3 Install Site Workbench Site Workbench is provided on the CD ROM included with the equipment Insert the CD ROM into a PC to run the installer Follow the onscreen instruction 6 4 Connecting to the Instrument Use a crossover network cable supplied with the test instrument to make the connection 1 The instruments through the network port access computer networks Connect the network cable to the port on the computer and to another port on the test instrument 2 Turn on the test instrument set the legitimate IP address 3 Run Site WorkBench management software enter the IP address of connected instrument 4 Press the Connect menu and press the connect to the specified IP address option So that the computer and instruments to build up the communication 54 E7000 Series Cable amp Antenna Analyzer User Guide 7 Specifications 7 1 Cable amp Antenna Analyzer E7000A E7100A Measurement VSWR Return Loss Cable Loss Distance to Fault DTF Return Loss Distance to Fault DTF VSWR 1 Port Phase Smith Chart Frequency range 25MHz 4400MHz 25MHz 6000MHz Freguency resolution 1kHz 25MHz 4 4GHz 2kHz 4 4GHz 6 1GHz Frequency accuracy 5 ppm Output power level gt 0dBm 25MHz 4 4GHz gt 5dBm 4 4GHz 6 1GHz 1 5mS point Return Loss Sweep time 2 5mS point DTF Data points 130 295 517 1033 S l 13 dBm within 10 kHz of the carrier frequency RF
45. us and each is described below in detail Setting Parameters Press the corresponding menu and the parameter Start Freg shows in the middle of the screen Use the 25 mz numeric keys arrow keys or Rotary Knob to set the parameter and press the Enter key to exit Two functions switch G PS Press the corresponding menu button to switch on LEE or the two functions Enter the next submenu no parameter SUS SECupD Press the corresponding menu key enter the next submenu Enter the next submenu with parameters Press the corresponding menu key enter the next Menu Hold gt submenu to select an option and then return to ais the previous menu automatically 16 E7000 Series Cable amp Antenna Analyzer User Guide Implement the menu function Data To Press the menu key to implement the Hemor y corresponding function Select to implement function Press the menu key and select a submenu to implement the corresponding function and then return to previous menu No operation Some of the menu are available that have to be pata amp Mem right state No opration When the menu grays out 17 E7000 Series Cable amp Antenna Analyzer User Guide 2 6 Symbols and Indicators The following symbols and indicators indicate the instrument status or condition on the display Calibration Symbols The current calibration status and type is displayed when in Cable amp Antenna A
46. y important for accurate measurements and for identifying faults in the transmission line Selecting the incorrect cable or using the correct cable out of its proper frequency characteristics type will shift the DTF trace vertically and horizontally making it difficult to accurately locate faults 24 E7000 Series Cable amp Antenna Analyzer User Guide Press the MODE main menu key and then press the Cable amp Antenna submenu key Select DTF VSWR or DTF Return Loss mode the default Start Distance is setO Press the FREQ DIST main menu key Press the Start Dist submenu key and use the keypad rotary knob or the arrow keys to edit the start distance value Press Enter to set Press the Stop Dist submenu key and use the keypad rotary knob or the arrow keys to edit the stop distance value Press Enter to set press key select the appropriate cable from the cable list and press Enter The cable loss and propagation rate will be set automatically Calibration Press the FREQ DIST main menu key and enter the appropriate frequency range Press the CAL main function key Press the Cal Type key to select Standard or FullSpan Cal Press Start Cal and follow instructions on screen Connect Open to RF Out and press the ENTER key Connect sho
47. yzer User Guide Press the submenu Quick Start Guide key to display the Quick Start Guide describe the basic steps DEVISER Quick Start Guide Help Set the Frequency 1 Press the FREQ DIST main menu key About 2 Press the Start Freq submenu key and use the keypad rotary knob or the arrow keys to enter the start frequency 3 Press the Stop Freq submenu key and use the keypad rotary knob or the arrow keys to enter the stop frequency Set the Amplitude 1 Press the AMPTD main menu key 2 Press the Top submenu key and use the keypad rotary knob or the arrow keys to edit the top scale value 3 Press the Bottom submenu key and use the keypad rotary knob or the arrow keys to edit the Bottom scale value Auto Scale The auto scale function is used to tailor top and bottom automatically in such away that traces will appear in the proper sizes on the screen for easy observation 1 Press the AMPTD main menu key 2 Press the Auto Scale submenu key Turn on Harkers 1 Press the MARK main menu key Return 2 Press the Marker 1 Marker 2 Marker 3 Marker 4 Marker 5 2011 08 01 16 21 Figure 5 5 System Menu Overview 50 E7000 Series Cable amp Antenna Analyzer User Guide 5 9 Print Menu Key Sequence gt Print Start Press the submenu to print the current displayed screen informations Before you start printing make sure what the printer is connected and whether select th

Download Pdf Manuals

image

Related Search

Related Contents

  Topo novembre décembre 2012 - Bibliothèque municipale de Lyon  製 品 価 格 表  Les références immobilières du notariat  Digital Spectrum MV-1500 Digital Photo Frame User Manual  Samsung DVD-R120 User Manual  Acer Aspire 605-MT12  ご契約の しおり スバルマイカーリース  JVC KD-G207 User's Manual  HT 1800/1  

Copyright © All rights reserved.
Failed to retrieve file