Home
Titan Series Pump Installation & Operating Instructions
Contents
1. Titan Series Pump Installation amp Operating Instructions CE INSTALLATION Only qualified licensed personnel should install pump and wiring IMPORTANT ELECTRICAL Electrical Contractors Please Note All 240 volt 50 Hz Titan pumps must be wired to the main power supply through an approved and correctly rated contactor Pump Mount Must Be solid level rigid vibration free Allow use of short direct suction pipe To reduce friction losses amp don t install the pump at more than 3M geometrical height from water level Allow for gate valves in suction and discharge piping Have adequate floor drainage to prevent flooding Be protected from excess moisture All adequate access for servicing pump and piping NOTICE Pump suction and discharge connections have moulded in thread stops DO NOT try to screw pipe in beyond these stops ZOPU09051705 A CAUTION Hazardous suction Can trap hair or body part causing severe injury or death Do not block suction ZODIAC A Routine Maintenance OPERATION NEVER run pump dry Running pump dry may damage seals causing leakage and flooding Fill pump with water before starting motor Before removing lid STOP PUMP before proceeding CLOSE GATE VALVES in suction and discharge pipes RELEASE ALL PRESSURE from pump and piping system NEVER tighten or loosen screws while pump is operation Do not block pump suction To
2. do so with body may cause severe or fatal injury Children using pool must ALWAYS have close adult Supervision Priming Pump Release all air from filter and piping system see filter owner manual In a flooded suction system water source higher than pump pump will prime itself when suction and discharge valves are opened If pump is not in a flooded suction system unscrew and remove lid cover fill housing and pump with water Clean lid inspect housing re install on lid cover Replace lid cover on housing turn clockwise to tighten cover NOTICE Tighten lid cover by hand only Pump should prime now Priming time will depend on vertical length of suction lift and horizontal length of suction piping The only routine maintenance needed is inspection cleaning of leaf basket Debris or trash that collects in basket will block off water flow through the pump Follow instructions below to clean leaf basket 1 Stop pump close gate valve in suction and discharge and release all pressure from system before proceeding 2 Unscrew the lid turn counterclockwise 3 Remove strainer basket and clean Be sure all holes in basket are clear flush basket with water and replace in housing with large opening at pipe connection port between ribs provided If basket is replaced backwards cover will not fit on housing body 4 Clean and inspect lid Ring reinstall on lid cover 5 Clean Ring groove on housing body and Replace lid To help keep
3. lid from sticking tighten hand tight only 6 Prime pump see priming instructions above ZODIAC ZODIAC SERVICE amp REPAIR PARTS Refer all service to your local agent or dealer as his knowledge of your equipment makes him the vest qualified source of information Order all repair parts through your dealer Give the following information when ordering repair parts 1 Unit nameplate data or serial number on label 2 Description of part MOTOR DOES NOT START 1 Disconnect switch or circuit breaker in off position Fuses blown or thermal overload open Locked motor shaft Motor windings burned out Defective starting switch inside singl phase motor Disconnected or defective wiring Low voltage om AOON N O PUMP DOES NOT REACH FULL SPEED 1 Low voltage 2 Pump connected for wrong voltage MOTOR OVERHEATS protector trips 1 Low voltage 2 Motor windings connected for wrong voltage on dual voltage model 3 Inadequate ventilation PUMP DELIVERS NO WATER 1 Pump is not primed 2 Closed valve in suction or discharge line 3 Leakage or air into suction system 4 Impeller clogged LEAKAGE OF WATER AT SHAFT 1 Shaft seal requires replacement TROUBLE SHOOTING LOW PUMP CAPACITY 1 Valve in suction or discharge line partly closed 2 Suction or discharge line partly plugged 3 Suction or discharge line too small 4 Plugged basket in skimmer or hair and lint strainer
4. 5 Dirty filter 6 Impeller clogged HIGH PUMP PRESSURE 1 Discharge valve or inlet fittings closed too much 2 Return lines too small 3 Dirty filters NOISY PUMP AND MOTOR 1 Plugged basket in skimmer or hair in lint strainer Worn motor bearings Valve in suction line partly closed Suction line partly plugged Vacuum hose plugged or too small Pump not supported properly OORA WN AIR BUBBLES AT INLET FITTINGS 1 Leakage of air into suction line at connections or valve stem 2 Cover gasket of hair and lint strainer needs cleaning 3 Low water level in pool NOTE For any further enquiries please contact your local authorised Zodiac dealer or call Zodiac customer service on 1800 688 552 ZODIAC PUMP PARTS FOR ZTS Meyno Description PartNo 7 Drain Plug Plug O ring 10 12 ZTS075 Impeller 3 ZTS100 Impeller ZTS150 Impeller 14 15 16 17 18 19 ZTS075 Motor 20 ZTS150 Motor 23
Download Pdf Manuals
Related Search
Related Contents
Règlement D90 BETRIEBSANLEITUNG - STROBL Beschichtungstechnik JOURNAL 18 - Souriez vous êtes filmés Philips CMQ205/00 User's Manual TAXE DE SEJOUR 2014 - MODE D`EMPLOI Copyright © All rights reserved.
Failed to retrieve file