INSTALLATION AND OPERATING INSTRUCTIONS

image

Contents

1. thermostat sensor fully into its pocket securing it with a dab of fire cement The thermostat is a delicate instrument and although it is tested and set at the factory it may need re adjusting Thermostat Sensor Damper 4 ee 6 Adjusting the thermostat With the fire cold the thermostat sensor vial in place and the thermostat control turned to 1 the air closure damper plate should be approximately 7 mm open HEATING CIRCUIT The GreenSwitch is for connection to open vented indirect water systems only with a maximum working pressure of 2 bar Every installation must include A pipe thermostat to prevent the pump running if boiler flow temperature drops below c50 C This prevents heat from stored hot water being dumped if the fire dies down and guards against condensation inside the boiler A pipe thermostat set at about 90 C to run the pump and dissipate heat in the event of boiler overheating irrespective of how other controls are set Means to completely drain water from the system A means of dissipating surplus heat such a permanently connected radiator or hot water system Means to allow steam to be released in case of complete thermostat and electrical failure In addition we recommend Radiators fitted with thermostatic valves An anti gravity valve preventing circulation to upper radiators when the pump is not running A room temperature thermostat and single circu
2. Air Supply if fitted Flue Collar 157mm dia wt Welcome to more than one hundred and fifty years of Esse You join the illustrious tribe of Esse fire keepers from Florence Nightingale Captain Scott Mrs Beeton Auguste Escoffier Queen Victoria and most of the Royal Families of Europe to Fred Dibnah and Hugh Fearnley Whittingstall THIS APPLIANCE BECOMES EXTREMELY HOT AND CAN PRODUCE POISONOUS GASES A fire guard should be used if children or the infirm are present The installer is required to EXACTLY follow these instructions and to comply with all local national and applicable international standards LOCATION This appliance is 400mm to 460mm heavy a load distribution plate may be needed on weaker floors The appliance must be located on a flat hearth extending at least 225mm in front of the fire and of suitable material to protect the building from fire Combustible materials including fuels must be at least 225mm away from the room parts of the appliance This stove can fit into fireplace openings of 400 to 460mm wide and 550 to 590mm high If the Outside air kit is used fireplaces must be prepared with an extra opening to the lower right of the face as shown YOUR CHIMNEY makes your fire work It stores surplus heat from the fire which makes the gas inside its hollow flue lighter so that it rises pulling fresh air through the fuel and making it burn The Greenswitch is for connection
3. Dismantle the boiler If the unit is supplied assembled lift off the top of the front and carefully pull the cylindrical brass thermostat sensor from its holder Unfasten the 4 bolts shown lift the front unit up slightly and carefully part the two units Take very great care not to damage the soft seal 2 Prepare the setting fit and test the boiler Place the boiler rear unit on a hearth which will extending at least 250mm in front of the assembled fire noting that the final surface of the fireplace will be just behind the two flanges arrowed In this example the air supply kit has been fixed to the side of the boiler with adhesive tape prior to being cemented in Complete the piping circuit fill and inspect for leaks as you wont be able to repair leaks later 3 Brick up and form the flueway Build up a masonry wall around the boiler forming a smooth connection to the flue with no ledges where debris could collect Fill any space with mortar and rubble Shown part completed 4 Fit fireplace surround Slot a ready made fireplace surround in place or build one up using brick stone or other masonry or metal materials Extra fixing if needed is through the screw holes shown 5 Refit front and check thermostat Bolt the door front unit back in place taking great care that the parts seal Reassemble the interior fittings and check that the door closes and seals properly Push the
4. call the fire brigade Prevent fires by using very dry fuel and having your chimney swept regularly DIRTY WINDOW Is fuel absolutely dry The window will become dirty when the fire operates at low levels for a long time but will usually self clean at higher burn rates MAINTENANCE EVERY MONTH When the fire is cold use the operating tool to pull forward and clean the throat plate Check that the door seals are sound ANNUALLY or more often if smoky fuels are used sweep the entire length of the flue from firebox to chimney outlet REPLACEABLE PARTS Internal parts will last far longer if special care is taken to empty ash from mineral fuels regularly to clean the throat plate and to use completely dry fuel The GreenSwitch has been extensively tested for safety please don t try to modify it and always make sure to get genuine spare parts Your GreenSwitch is guaranteed excluding wearable parts for one year from the date of purchase in addition to your statutory rights 4 SE REPLACEABLE PARTS The Esse 300 and 350 Greenswitch Boiler the Furnesse Chroma and Virtine door designs are registered at the UK Patent Office and protected by Copyright and UK Design Right Glyn Hughes and the Ouzledale Foundry Esse Engineering 1994 2009 The Esse 350 Greenswitch central heating boiler is UK Patent Applied For Esse appliances are forever being developed and improved your applianc
5. is a renewable fuel and because a burning log can t give out any more carbon than the tree itself absorbed while living it is considered to be greenhouse gas neutral Fresh wood may seem dry but its cells are full of water Burning such green wood wastes heat in making steam and produces tarry condensation which will damage your appliance and chimney Logs should be split and dried in a well ventilated place for one to three years Only ever use thoroughly dried out wood The white residue from burned wood is not ash but cell walls which can burn if kept hot enough so with wood alone don t de ash the fire until absolutely necessary JOINERY WASTE can be a useful fuel if completely dry but don t use timber with preservatives as it can emit very poisonous fumes PEAT The nearly black moorland or bog peat should be dried and treated as for wood LIGNITE is a mineral between peat and coal It lights easily and burns well though may produce excessive ash and smoke ANTHRACITE is a natural hard shiny smokeless form of coal It burns with great heat and lasts a long time BRIQUETTES are compressed blocks of fuel generally able to burn for long periods and remarkable for their consistency NOT RECOMMENDED PETROLEUM COKE is very high in acid and will damage your appliance BITUMINOUS HOUSECOAL is cheap but rarely value for money burns with violent flame and tarry smoke It will stain the window is difficult to control and can explod
6. the door and lift out the ashpan Let ash cool before disposing in plastic bins There is no need to empty every speck but make sure that ash from mineral fuels never builds up so that it touches the underside of the grate or the grate will melt EXTENDED BURNING Allow the fire to burn down to a low hot fire bed Empty the ash and well fill with smaller pieces of hard fuel such as anthracite CLEANING Wipe the body when cool Soot will condense on the window if the fuel is damp or if the fire operates at low outputs for long periods Deposits will normally burn off when the next fast burning cycle comes round but persistent stains can be removed with a household bleach spray cleaner when the fire is cold DOOR Your GreenSwitch is designed to be operated only with the door closed Open the door slowly to minimise fumes emission AUTOMATIC CONTROL Your GreenSwitch has three controls Boiler thermostat This senses the temperature of water in the boiler and automatically allows air in to make the fire burn more or less fiercely so that water always leaves the boiler at about 50 C on setting 1 to about 90 C at 10 1 2 GreenSwitch control Simply pull out for wood push in for mineral fuels like anthracite 3 Door air control a slide or spinwheel fitted on some models for compatibility with non boiler versions Keep it closed at all times FUEL must be dry with no dust or pieces smaller than about 40mm WOOD
7. to a single flue which must be Able to operate safely at temperatures of up to 500 C Free from even the slightest leak and absolutely incapable of spilling fumes into the dwelling Smooth internally unobstructed and able to be swept along its entire length Generate a continuous up draught in use of at least 14Pa 0 06insWG These ends will often be achieved by the chimney being constructed entirely of masonry or insulated metal components having an internal size of more than 150mm but less than 300mm being substantially vertical with no severe bends or horizontal portions being at least 5m high and terminating at least 1m above any roof AIR SUPPLY All fuels need a continuous supply of fresh air from to burn There must be an air supply into the room from outside the building incapable of being closed off and equal to a total of least 55cm c7 5cm square Leakage around doors and windows is not always sufficient while an extractor fan or another fuel using appliance even in a different room can remove this air and cause dangerous fume emission An air supply kit is available to bring combustion air directly from outside the building to the GreenSwitch boiler greatly reducing the risk of draughts and significantly improving performance TYPICAL INSTALLATION INTO MASONRY CHIMNEY This is the traditional method used in Britain and Ireland Other methods of installation are possible ask Esse for a leaflet 1
8. GreenSwitch BY SSe BIOMASS MINERAL FUEL FIREPLACE INSET ROOMHEATER WITH THERMOSTATIC BOILER Different front styles are available Z Ss INSTALLATION AND OPERATING INSTRUCTIONS LEAVE THIS DOCUMENT WITH THE HOUSEHOLDER STRUCTION CONFo S5 SEN 13240 EUROPEAN STAND Water For use only with open vented indirect water systems Maximum pressure 2 bar Can be inter connected with combi boilers amp other heat systems using Esse Centraliser Unit C All mechanical thermostatic air supply to fire in response to boiler temperature No electrical ontrol System connections or parts Can be controlled by time clocks room thermostat etc For installation in masonry firep with a single dedicated chimney Fireplace ee lie pinata fie araugnt dea ops i i Clearance Physical space 100mm around in room parts From combustibles 225mm Extended Burn Variable with fuel heat demand and chimney conditions Anthracite c12 hrs MAXIMUM PERFORMANCE With door closed Biomass Wood Logs Mineral Fuel Ancit burning dry fuel with flue draught of 14Pa With type 395 Boiler With type 395 Boiler Mean flue temperature 395 C 364 C Flue gas flow 8 52 g sec 13 6 g sec Mean CO in flue as if at 13 02 0 4 0 12 Efficiency 75 7 72 7 Total output from appliance 14 7 kW 50 443 Btu 14 6 kW 49 802Btu Output to room 3 6 kW 12 437 Btu 2 8 kW 9 714Btu Output to water 11 1 kW 38 006 Btu 11 8 kW 40 088Btu F
9. e HOUSEHOLD WASTE Plastics create toxic fumes Batteries amp aerosols explode Never use liquid fuels SMOKE Compliance with smoke regulations is the responsibility of the user To ensure low smoke emissions on wood 1 Make sure the fuel is absolutely dry less than 15 water 2 Split logs into pieces no more than about 100mm diameter 3 Refill little and often 4 Try to load logs criss cross so that plenty of air can circulate around them It is often beneficial to burn a little clean mineral fuel such as anthracite along with the wood SUMMER SHUT DOWN Before a long period of non use leave all the air controls open to allow ventilation to reduce condensation PROBLEMS NOT ENOUGH HEAT Is fuel really dry Is chimney draught correct Are the room and fire controls set correctly The GreenSwitch is designed to provide heat into water when installed in a large room a radiator will be needed too LACK OF CONTROL Are the door seals sound Some types of wood lignite and coal are difficult to control CONDENSATION happens when water vapour touches a cool surface inside the fire mixing with combustion products to make sticky tar Water comes from the fuel Even dry wood may hold a 150mm cupful in every 1kg log Prevent condensation by using only absolutely dry fuel and fit the correct thermostat to prevent cold water from circulating through the boiler DIFFICULTY BURNING FOR EXTENDED PERIODS The GreenSwitch is thermostat
10. e you may differ from the one in this booklet This document Issued 28 10 2008
11. ic it will keep on making the fuel burn vigorously for as long as there is a demand for heat so if water still circulates through radiators eg at night the fire will continue to burn consider adding an anti gravity valve to stop unwanted circulation when the pump is off or simply turn the boiler thermostat down at N 0 Hughesi S97 Design Made With WolframHTS HEAT RESIST ALLOY STEEL night Are the door seals sound Is the flue free from cracks For longest burn use hard fuels like anthracite SMOKE COMING INTO ROOM Occasional fumes while loading or de ashing may occur but persistent emission to the room must not be tolerated First and always measure the chimney draught it must be at least 14Pa in use Causes of poor draught include LEAKS Even the tiniest crack in the flue can spoil the draught BLOCKED FLUE Pull out the throat plate to inspect In any case of doubt have the chimney professionally swept COLD FLUE Smoke only rises if kept hot Is chimney fully insulated LACK OF FRESH AIR Make sure there is an unobstructed fresh air supply to the fire DOWNDRAUGHT Wind can blow down the flue if there is something higher near the chimney such as a tree hill or high building Fit an anti downdraught cowl to the chimney top CHIMNEY FIRE In the rare event of deposits inside the chimney igniting roaring sound dense smoke and sparks from the chimney immediately close the door shut all air controls and
12. it time clock controlling the running of the circulating pump The diagram shown one possible arrangement MULTI BOILER SYSTEMS with simultaneous automatic control of the GreenSwitch and gas oil cooker boilers heat stores combi boiler etc can be achieved using an Esse Centraliser unit Details are available separately COMMISSIONING The installer must complete the notice at the beginning of this document demonstrate the method of lighting control and cleaning and point out the safety requirements to the householder GETTING THE BEST FROM YOUR GreenSwitch Every fuel chimney and condition of use is different Only experience will show which is the best for you We suggest trying several different fuels or mixtures and different settings of the controls GREENSWITCH GETS VERY HOT Use a glove or the tool supplied to manipulate hot parts and controls LIGHTING After a period of non use do check the chimney for blockages first Empty the ashes Place two or three firelighters close together or screwed up paper covered with dry sticks at the back of the grate and light them When they are burning well gently fill the fire with dry fuel to the level shown Don t over fill or allow fuel to touch the throat plate EMPTYING ASHES Use the tool to pull the de ashing mechanism on the right hand side of the fire back and forth If it jams don t force it but wait a few minutes for any obstructing fuel lump to burn away Open
13. uel per hour at maximum 3 8 kg 2 4 kg Maximum achieved at refuelling interval of 1 hr 2hr NOTE Figures are for heat from the appliance only There will typically be additional often substantial heat gains from the masonry of the fireplace and chimney and consequent higher total efficiency Total performance for a particular building can be calculated by the method of EN13384 Manufactured by Esse Engineering Ltd Long Ing Barnoldswick Lancashire BB18 6BN England www esse com This document when completed by the installer constitutes a Hearth Notice for purposes of the England and Wales Building Regulations 2000 App Doc J4 It must be left with the householder and placed where it can easily be found APPLIANCE SERIAL NUMBER INSTALLED AT LOCATION Flue Draught measured on BY commissioning EMERGENCY TELEPHONE SIGNED DATE Fuel used on Who certifies that this installation is safe has been demonstrated to the householder commissioning conforms with current building regulations and with these instructions TO FIND A QUALIFIED INSTALLER FUEL SUPPLIER or CHIMNEY SWEEP CONTACT UK The Solid Fuel Association 7 Swanwick Court Alfreton Derbyshire DE55 7AS Tel 0845 601 4406 www solidfuel co uk Rol Irish Nationwide Fireplace Organisation 162 Capel Street Dublin 1 Tel 01 801 5959 www fireplace ie 1 Read these instructions Use only recommended fuels BSP in Female Parallel 332mm Outside