Home

Landis & Gyr RAV 91 Operating Instructions

image

Contents

1. 7 8 That you can switch the automatic heating program off without erasing it 9 That with CHRONOGYR you can operate and also switch off your heating system from your living room That CHRONOGYR switches your heating system automatically off when it is warm enough outside and on again when this becomes necessary Siemens Building Technologies HVAC Products RAV91 5 6 That CHRONOGYR offers energy savings with frost protection operation when you leave the house for several days e g during your holiday 9d Replacing the Batteries 1 Insert screw driver in the slot of the black baseplate and press slightly down see fig 1 2 Remove unit by swinging it upwards see fig 2 3 Remove old batteries 3 pieces and replace by new batteries according to symbols Recommended type of battery Alkaline type leaking proof 4 Replace unit in baseplate an swing downward must engage in baseplate 5 Check if the unit is fitted properly 6 Set correct time Siemens Building Technologies HVAC Products RAV91 6 6
2. is automatically put into the operation and maintains a room temperature of 8 C whenever there is a risk of frost in the living room 10 Indication of the actual mode of operation Window is red normal heating program Window is blue reduced heating program 11 Override Switch This switch is used to manually override the automatic time switch program This means that you can change over from normal red to reduced blue heating and vice versa After the next switching operation the heating system returns to the automatic time switch program Note The override switch is operative only if The program selector slider 9 is set to 9a The last automatic switching operation took place more than 45 minutes ago 12 Battery Check This light is used to check the condition of the batteries Procedure Move the program selector slider 9 upwards Red lamp lights up Batteries are still in good condition Red lamp does not light up replace batteries with new ones 13 Operation Check Must turn in steps of seconds 14 Instructions for replacing the battery Batteries are replaced every 4 to 5 years see also item 20 Siemens Building Technologies HVAC Products RAV91 4 6 Heating and Saving Tips Maintain your room temperature at 20 C to 21 C 4 never above because every additional degree increases your heating costs by 6 to 7 percent However if you feel comfortable at 18 C then set the temperatu
3. SIEMENS Landis amp Gyr RAV 91 Operating Instructions WIG 6b 40 12 14 Yee 6a 7a 8 7b sur o 12 14 Siemens Building Technologies HVAC Products RAV91 1 6 Operation Settings Readings 1 Setting wheel for time switch When setting the time switch note items 2 and 3 wheel can be turned in both directions 2 24 Hour Scale Showing the 24 hour day This scale is used to select the heating program by means of the setting sliders 6a 6b 7a 7b 3 Time indicator Indicating the time of day e g 7 00 h or 19 00 h 4 Normal room temperature Here you set the room temperature you require when you are at home Recommendation 19 21 C 5 Reduced room temperature Here you set the room temperature you require at night or when you leave the house for a few hours or for the weekend Guide value 10 15 C 6a Start of the normal heating program in the morning The time to be set here should be about 2 1 hour prior to the time you usually get up This is the time when normal heating starts red 6b End of the normal heating program in the evening The time to be set here should be about 2 1 hour prior to the time you usually go to bed This is the time when reduced heating starts blue Siemens Building Technologies HVAC Products RAV91 2 6 Overriding of the normal heating program in the evening 7a Start of override function The time to be set
4. here should be about 12 hour prior to the time you go to work This is the time when reduced heating starts blue 7b End of override function The time to be set here should be about 1 hour prior to the time you usually get home from work This is the time when normal heating starts red 8 Overriding of the normal heating program YES or NO Selection of the automatic overriding function 8a Blue section pulled out Normal heating program is overridden for weekdays 8b Blue section pushed back Normal heating program is not overridden for Saturdays Sundays or holidays 9 Selection of the heating program The heating program is selected here according to the symbols 9a Position clock means Operation of the heating system according to the automatic time switch program set with the sliders 6a 6b 7a and 7b From red to blue on normal room temperature From blue to red on reduced room temperature 9b Position sun means This position provides continuous normal room temperature 4 The automatic heating program according to the time switch is inoperative 9c Position moon means This position provides continuous reduced room temperature 5 The automatic heating program according to the time switch is inoperative Siemens Building Technologies HVAC Products RAV91 3 6 9d Position readiness means This position provides no heating but the heating system is ready to operate Also it
5. re to 18 C and you reduce your heating costs by 6 to 7 percent When you sleep you lie in your warm bed So why should you maintain normal room temperature Reduce the temperature at night 5 to perhaps 12 C or 15 C If you leave the house for more than two hours when you go shopping for example set your heating system to reduced operation 10 If you are absent for several days e g holidays weekends you should set your heating system to frost protection operation 9d Check if your heating system does not switch too early to normal temperature and too late to reduced temperature If necessary change the switching times 6a 6b 7a 7b Renewing the room air by having the windows slightly open is expensive so don t do it Renew the room air by opening the windows fully but only for short periods of time If you don t have the thermostatic radiator valves in your house it s time to fit them because they reduce the consumption of heat Contact your heating installer and ask for RADIAGYR During the warm season when heating is not required you should switch off your heating installation on the room unit 17 Did you know That with CHRONOGYR you can heat less at night i e the room temperature can be reduced 5 That you can also heat less during the day if you are a working couple 5 7 That CHRONOGYR operates your heating system fully automatically according to a pre selected program 6