Brief operating instructions.
Contents
1. Do not fill the central hole A mouthwash glass drain 15 KaVo Primus 1058 S TM C G Instrument rinsing programme Control element display only in conjunction with the intensive disinfection kit Press the LP AP button AP LEDs flash for 4 seconds While they are flashing press the Spray button Place the sterilisation attachment on the ceramic bowl or insert it in the glass bowl COMFORTbase Place the instruments in the sterilisation set on the spittoon Press the foot pedal to display the time for rinsing the instruments and triple or multifunction handpiece The standard value for rinsing program is 02 00 00 minute per instrument Adjust the time with the Chair up and Chair down keys from 0 00 to 8 30 minutes Start the instrument rinsing program Press the Spray key when turning on the device again e g on the following day The spray air LED flashes yellow wasn the spray water LED flashes green A power LED flashes green and service LED flashes yellow Set down the instruments End of the instrument rinsing program Y 7 p p Ae Be x ge G amp Ooi SN p syr p 2 PA can be immediately terminated by pressing End the rinsing program The rinsing program 4 the Spray key again or turning the device off and on 16 KaVo Primus 1058 S TM C G Intensiv sterilisation optional Control element display Start intensive sterilisation without an au
2. E123 COMFORTdrive 200 XD D J with installed Memospeed Level 1 2 3 0 2 2 3a pooiers Motor Remove motor PIEZOlux a N Press level preselection key minimum 000 until a signal is heard minimum 400001 4 Set the intensity using the pr minimum lt maximum plus key and minus key xx vv motor maximum 000 Minimum mode j maximum 40000 aT K motor 400 min KL motor 2000 min Maximum mode y K motor and KL motor 40000 min NN minimum 1 0 PIEZOlux COMFORTdrive 200 XD minimum 1600 al BI Minimum 1 Maximum 10 The step size is 0 25 E123 EE COMFORTdrive 200 XD Min 1 30 000 min N Max 10 200 000 min maximum LO Storage maximum 10 00 lt a Press level preselection key until a signal is heard E123 e sezay KaVo Primus 1058 S TM C G ON OFF functions of heating Control Display and cold light on the multi function handpiece Setting on dentist s element Remove multifunction handpiece mf syringe from the holder BEHR HET Holder switch is operated Press spray preselection key or press spray preselection key on the multifunction foot control for multifunction handpiece on dentist s element are preselected Storage 7 gt a Press LP AP key with instrument ED picked up until a signal is heard LED lights up heating and cold light Y Lil Cold light intensity is constant 10
3. KaVo Primus 1058 S TM C G ON OFF functions of heating Control Display and cold light on the multi function handpiece Setting on Comfort assistant s element Remove multifunction handpiece mf assist from the holder TEHE HEE Press air or water key on the multifunction handpiece briefly Press spray preselection key or press spray preselection key on the multifunction foot control LED lights up heating for multi function handpiece on assistant s element is preselected Press cold light preselection key LED lights up cold light for multi function handpiece on assistant s element is preselected Storage Lil Cold light intensity is constant Press LP AP key with instrument picked up until a signal is heard 11 KaVo Primus 1058 S TM C G Setting the time OD S Press clock key until a signal is heard Set hours by means of the plus key set hovr3 and the minus key DE ULE D J Press clock key again briefly set minutes 08 01 00 Set minutes Press clock key again briefly Set seconds to zero set seconds s n 08 01 00 8 Timer Timer start Press timer key The set time starts to run After the time has elapsed a signal is heard Saving Press clock key until a signal is heard OD J Setting the timer Press timer key until a signal is heard Set desired time using the plus key and the minus key Max 8 minutes 3
4. 0 seconds D lt a at OJ Press timer key until a signal is heard KaVo Primus 1058 S TM C G Handling function keys Control Display Select the function using the plus prog ram F1 00 and minus keys bell relais 1s Setting a function Press key F1 or F2 until a signal is heard Save the function Press key F1 or F2 until a signal is heard Calling up the function The saved function is triggered if the F1 or F2 key is pressed briefly Lil 14 functions are preprogrammed 13 KaVo Primus 1058 S TM C G Hydroclean function Control Display Calling up function Press LP AP key Preparation LEDs flash for about four seconds Press the key bowl rinse The Hydroclean function is started L Press again for switching off the function i This function activates the suction machine and causes the suction lines from filter housing to separation system to be flushed with clean water fully automatically for approx 150 seconds Bowl rinsing is switched on and off several times 14 KaVo Primus 1058 S TM C G Refilling Oxygenal Control Display When a tone is heard at one second intervals J I J 10 tones the storage tank is empty a 0 10 sec 20 sec Remove mouthwash glass filler and cover Fill with one bottle of Oxygenal max 1 litre When a tone is heard at one second intervals 10 tones the storage tank is full Stop refilling immediately
5. KaVo PRIMUS 1058 S TM C G Brief operating Instructions KaVo Dental Excellence KaVo Primus 1058 S TM C G They do not replace the standard operating instructions which form part of the delivery It is essential to consult the standard operating instructions in order to avoid faults and damage These brief operating instructions cover only the essential control functions Patient s chair Control Save automatic position Set desired chair position using keys or f using multifunctional foot NA control when instruments are 1 replaced in the holder Press key LP AP briefly ED LEDs flash for about 4 seconds f w y L AN w A w Press required key for about 4 NAN NA NA NA 1 SP 0 2 seconds until a signal is heard Assignment of the AP keys on the multifunctional foot control Keep foot switch and AP key depressed and also press desired key on the dentist s or assistant s element until a signal is heard iv A P QO tO SS 2 KaVo Primus 1058 S TM C G Dental chair Control Call up automatic position amp Assistant s element and 0 Comfort assistant s element Press LP AP key briefly LEDs flash for about four seconds During this time press desired key AP briefly Standard assistant s element Press joystick briefly LEDs flash for about four seconds During this time move joystick in the appropriate direction Or with instrument removed cal
6. after the rinsing process This function is necessary when intensive sterilisation has Lil already started and the treatment unit has to be used for example in emergencies in hospitals etc After intensive sterilisation the oxygenal concentration is higher The automatic rinsing process duration about 6 min may therefore not be terminated After the rinsing process the concentration is normal 18 KaVo Primus 1058 S TM C G Warnings Display Safety cut outs A safety cut out Is active if one of the LEDs of the automatic position keys flashes Assignment Backrest SP fe Seat ae Underside chair parallelogram Vacu Stopp Stirrup on multifunction foot control Assistant s element AP1 Patient s part swivelled over AP2 the patient s chair Microswitch Dentist s element C APO NA i The safety cut outs immediately stop the respective chair movements KaVo Primus 1058 S TM C G Further warnings Display Oxygenal tank empty signal tone is heard at ten second intervals Oxygenal tank full Ten signal tones at one second intervals Amalgam separator signal is heard Ev The Service LED flashes ER This only indicates a fault in the amalgam 2 separator Detailed information is given on the display of the amalgam separator and in the associated operating instructions Bowl suction valve overfilled Service LED flashes for 10 seconds w Emergency off switch fo
7. ax 49 7351 56 1488 www kavo com
8. l up automatic position For safety when the spittoon is swivelled in the Lil chair movement is limited 3 KaVo Primus 1058 S TM C G Choose dentist s level 1 2 When instruments are set down Switching on the multifunction foot control Keep the foot switch depressed and additionally operate the stirrup switch or Switching on the Memospeed control Keep level preselection key depressed until a signal is heard Dentist s level 1 Dentist s level 2 Control Display E123 a lt r Ij Le Le KaVo Primus 1058 S TM C G Instruments Control Display Set cooling state Remove instrument V or i Tar Cooling state Spray Y w X Storage without installed Memospeed Press LP AP key with instrument picked up until a signal is heard Storage with installed Memospeed Press level preselection key Ze J with instrument picked up until a signal is heard KaVo Primus 1058 S TM C G Instruments Control Display Set cold light on off and cold light intensity Remove instruments Press cold light preselection key briefly Cold light On Q Intensity without installed Memospeed min max 1 2 3 4 5 6 7 8 9 10 Keep cold light preselection key depressed J pi 1x gt 10x Storage Press LP AP key with instrument S J picked up until a signal is heard KaVo Primus 1058 S TM C G Setting the cold light Control Display in
9. r bowl suction valve is operated Water for bowl rinse and mouth A wash glass filler is switched off 20 KaVo Primus 1058 S TM C G Functions on multifunction footcontrol Function with instruments removed Function with instruments placed in holder or instrument removed and stirrup switch pressed once Stirrup carrying handle with switch for safety cut out Cross switch for operating the patient s chair preselection counterclockwise Patient s chair Patient s chair automatic automatic postion postion Spray Air blast preselection Foot switch for activating and for speed intensity regulation of the instruments Chair functions are switched off again by operating the foot switch 21 KaVo Primus 1058 S TM C G 22 KaVo Primus 1058 S TM C G Memospeed Display Level switching Saving Minus Plus Timer Time Function 1 Function 2 Dentist s unit Seat up Automatic X ray viewer Mouthwash position 0 glass filler Last position Dentist s level 2 Automatic position Bowl flush Service LED preselection Saving SEE WA lt Ye Dentist s level 1 Unit On indicator Backrest down Backrest up Spray preselection Treatment position 1 Treatment position 2 Seat down Instrumenten light R L motor rotation Rinse position direction 23 1 001 6813 En 20090311 05 en KaVo Dental Excellence KaVo Dental GmbH D 88400 Biberach RiB Telefon 49 7351 56 0 F
10. tensity Level E 1 2 3 with installed Memospeed Remove instruments E123 Press level preselection key sg until a signal is heard ET23 lt r Press level preselection key 2 x briefly The cold light intensity can be set in 10 steps using the plus key or the minus key Storage Press level preselection key until a signal is heard E123 J KaVo Primus 1058 S TM C G Speed setting turbine Control Display with installed Memospeed Level 1 2 3 Remove instrument Press level preselection key E123 pr until a signal is heard It is possible to switch between maximum and manual mode using the plus key and the minus key Maximum mode The turbine is always operated at maximum speed at every position of the foot switch turbine maximu 1 D gt a turbine manuell 1 Manual mode A speed between 160 000 min left stop and 300 000 min right stop can be selected by means of the foot switch on the multifunction foot control Storage Press level preselection key E123 J until a signal is heard r IC Setting the Motor reverse Remove motor from the support Press motor reverse key or press motor reverse key on the multifunction foot control LED lights up Motor reverse has been preselected Saving Press LP AP key with instrument picked up until a signal is heard KaVo Primus 1058 S TM C G Speed setting motor Control Display Intensity setting PIEZOlux
11. tomatic request Press the button when the instruments are mounted until you hear a beep and the LED flashes once every second Place the instruments in the sterilisation set on the spittoon Start the function Press the key Intensive sterilization runs automatically End of intensive sterilisation de Request for intensive i disinfection LED flashes at two second intervals 1 o COMFORTbase N SP After rinsing the instruments with a high oxygenal concentration the start of the dwell time is signalled with a 4 second beep The dwell time is 30 min During this time the device can be turned off After intensive sterilisation is over the Device ON LED and the service LED flash After placing the instruments in their holders the device is ready to operate KaVo Primus 1058 S TM C G Skip exposure phase Control element display Function Intensive sterilisation occurs in sim NA step 7 4 5 before the dwell time 1 Turn the device off and on The intensive sterilisation switches to step 3 6 The automatic rinsing process starts Set down the instruments after the rinsing process AS Intensive sterilisation is in step 4 e dwell time Simultaneously press and J hold the intensive sterilisation key and hydrocolloid key Simultaneously press the foot button W until you hear a signal The intensive sterilisation switches to step 3 6 Ui Set down the instruments
Download Pdf Manuals
Related Search
Related Contents
White Rodgers 37-6658D User's Manual Apex dBQ-Zero - manuel d`utilisation USER GUIDE - Ultimate Ears iGuard IP-390E-QG トラクタユニットをプリンタ本体の前方に取り付ける (TDI) 1983-2007 - HES Samsung SMART CAMERA NX200 Керівництво користувача Samsung Galaxy Core Dual Sim Lietotāja rokasgrāmata AMX V2-LICENSE-LIVEUSER Copyright © All rights reserved.