Home

Operating Instructions Energy Monitor

image

Contents

1. Operating Instructions Energy Monitor A w ff Time hour kwh Remai s on of ur emain n T T2 a Li Li Total Price 5 8 8 B 8 TIME M ooe 3 4 Front Panel Description 1 LCD display 2 V AC Voltage A AC Current W Watt Select button 3 MODE Power on button 4 230V AC supply power 1 indication 5 Load power plug 2 6 SET CLR Reset exit button 3 7 TIME display button 8 Set DOWN button 9 Set UP button 5 Note Tilt battery compartment are on rear of unit 5 LCD Display 1 The above figure shows the actural voltage current active power values of current metrical as follows 1 ppan 2 Middle figure show the time of the electric energy meter billing current time T1 T2 s time and general energy consumption as follows 3 The following figures are used to display current total electricity billing and price setting and can be budgeted the total cost by every day every month year as follows 3 988 85 These operating instructions belong to this product They contain important imformation for operation and handling They must be observed even if the product is passed on to a third party In this regard keep these operating instructions for future reference 1 Introduction With the Energy Monitor you have acpuired a measurement device created according to the most current state of the art You are now able to determine power costs of your power loads in the easiest way The Ene
2. ground wire The connected load may mot exceed 3000W 13A The recommended operation temperature is between 10 and 40 C High temperatures especially during measurement of large power loads lead to danger of overheating and can thereby permanently destory the Energy Monitor B Display current time setting e Press TIME button into current time mode e Press SET CLR button into setting mode Hour or Minute digital will flash display When Hour or Minute digital will flash display press UP or DOWEN button setting time e Again press SET CLR button the Energy Monitor into normal display current time when Hour or Minute digital will Static display C Display the electricity consumption of electric energy billing explorer and the setting of time and billing e Press MODE button between LCD display on and hour e Press MODE button between LCD display on and kwh that mean the total power consumption at this time press the SET CLR key will clear all data e Press MODE button between LCD display Time mean the time of current total power consumption at this time press the SET CLR button to set the starting point of electricity time e Press MODE button between LCD display display T1 and Time mean the start time of T1 now press the SET CLR button to set the starting point of T1 electricity time e Press MODE button between LCD display display off T1 and Time e
3. voltage 230V AC 50Hz alternating voltage AC Max connected power 3000W 3kW Max current 13A Via protected contact plug outlet Blinking display at approx 3000W Caution More than 3000W will destroy the device 1 1W typical max 2 and 2W for Measurements up to 2500W max 4 for measurements over 2500W 10 to 40 C two 1 5V AAA batteries When has not turned on 230V AC power supply the Energy Monitor appliance automatic close down s time probably is 5 seconds Tariff setting range 0 01 to 99 99 Power load display 1 to 3000 kwh Voltage measurement 1V Current measurement 0 01A Input Output Overrun display Tolerance Working temperature Battery type Auto power off Active and apparent power 1W Energy kwh and costs Total 0 01 Dimensions L x W x H approx 140 x 72x 43mm Weight 214g 11 Liability exclusion e Manufacturers and distributotors take no responsibility for incorrect measurement values or the results of such values e This product may not be used for medical purposes or published information e This desice has been developed as an indicator for current usage and energy costs Despite the high accuracy of the device it is not to be used official calculation between power providers and users e The technical data of the device can be changed without prior notice e The product is not a toy keep it away from children e These instruction or declarations may only be reproduced with the perm
4. ission of the manufacturer mi Rev 090630
5. rgy Monitor meets with the safety and corresponds with the repuirements of valid European and nationa guidelines The conformity was proven and the corresponding declarations are available from the manufacturer In order to maintain this condition and ensure safe operation you as the user have to observe this operating manual 2 0peration The measurement range of the energy Monitor extends from 50 to 3000W If values fall below or exceed these limit values exact measurements are no longer possible Also the device could be overloaded and thereby destroyed The Energy Monitor has been developed for monitoring and measuring electrical loads Although the Energy Monitor is very accurate it is not officially certified for usage by power companies and users for measuring power expenditures e The Energy Monitor is only certified for operation at 230V AC The maximum power of any connected load may not exceed 3000W max current 13A 6 Properties e Monitoring of voltage current active power display Max value recording of voltage current active power e Display of used energy and accrued power costs e Cost forecast 7 Connection operation settings Before you connect the Energy Monitor to an outlet or power load the desired power tariff must be set Note when has not turned on the AC230V electric power supply presses MODE key to be possible starting to carry on the function establishment A Display of supply voltage load c
6. s correctly has been stored for a long period under unfavourable conditons or has been placed under heavy stesses in transport If the long time does not use please take the Energy Monitor internal batteries preservation in the dry place e Press MODE button between and following LCD screen display kwh and Day show that according to the unit price you setting you can buget total cost of electricity by day e Press MODE button between and following LCD screen display kwh and Month show that according to the unit price you setting you can buget total cost of electricity by month e Press MODE button between and following LCD screen display kwh and Year show that according to the unit price you setting you can buget total cost of electricity by year e The specific set ways as follows The total electricity consumption in the medium screen hour The total cost of electricity under Screen Total Press MODE The total electricity consumption in the medium screen kwh the total cost of electricity under Screen Total Press SET clear 0 Press MODE The current time in the mediun screen Time the total cost of electricity unde Screen Total Press SET into time setting press UP DOWN adjust press SET affirm Press MODE The strating time of T1 in medium screen Press SET into the strating time on the total cost of electricity under lof T1 s setting press UP DOWN Screen Total adju
7. screw of the battery compartment and remove the battery compartment e Remove the used batterty from the Energy Monitor and replace it with two new 1 5V AAA batteries Observe correct polarity when inserting the battery e Replace the battery compartment cover and refasten the screw 9 Additional notes The connected loads should be operated as normal when producing the cost forecast if an exact cost forecast is to be made per week month year for a power load we recommend leaving the energy monitor connected to the load for at least one day The energy monitor can thereby calculate an average power load and accrued costs more accurately The longer the Energy Monitor is connected the more accurate is the cost forecast The power supply on a power net is never constant and varies from place to place For example a voltage fluctuation of 1 per second for a calculated cost forecast over 5 minutes will never be as accurate as a cost forecast taken 3 hours Some devices use more current than others immediately after switching on The current usage decreases the longer the device is use warm up phase 10 Maintenance e Regularly inspect the Energy Monitor for damage e For cleaning the device and LCD only use a dry soft cloth Do not use any cleaning solutions e Never immerse the device in water e Maintenance or repairs may only be performed by a technician familiar with associated regulations Technical data Operating
8. st press SET affirm Press MODE The ending time of T1 in medium screen Press SET into the ending time off the total cost of electricity under _ Iof T1 s setting press UP DOWN Screen Total adjust press SET affirm Press MODE The total electricity of T1 in medium screen in the under screen Total Press MODE kwh The total electricity consumption gt Press SET into the cost of T1 s setting Price press UP DOWN adjust press SET affirm The total electricity of T2 in medium screen kwh the total cost of electricity under Screen Total Press MODE Daily Budget of current total power consumptionat current power in medium screen daily budget of current total cost of electricity under screen Press MODE monthly Budget of current total power consumptionat current power in medium screen monthly budget of current total cost of electricity under screen Press MODE yearly Budget of current total power Consumptionat current power in medium screen yearly budget of current total cost of electricity under screen Press SET into the cost of T2 s setting Price press UP DOWN adjust press SET affirm 8 Replacing the battery When the LCD loses contrast immediately replace the battery of the device The Energy Monitor requires two 1 5V AAA batteries For replacing the battery proceed as follows e Turn the
9. urrent load active power values e Immediately after the Energy Monitor is plugged into an outlet the supply voltage load active power and present current consumption of the connected loads is displayed in the LCD e Press the V A W button select to display of supply voltage load current load active power values When supply voltage gt 250V AC Load current gt 13A Load active power gt 3000W LCD will display OL and flash alarm e Operation of the Energy Monitor is only pemitted in interior spaces and dry environments Usage in the open air is strictly forbidden e Always observe the declarations on the identification labels of connected power loads Another use than the one described above leads to damages to the product and is also associated with dangers like short circuit fire electric shock etx The entrie product may not be converted or modified The safety instructions must be strictly observed 3 Safety instructions We will not assume any liability for damages to items or persons caused by improper handling or non com pliance with the safety notices Any warranty claim will become null and void in such cased It must be observed that the conductive ground wire is not broken as this can plse lethal danger in the event of a malfunction This device is not a toy and does not belong in the hands of children Only connect the Energy Monitor to certified protected comtact outlets 230V AC 50Hz 10 16A with a
10. xpress the end of time of T1 now press the SET CLR key to set the starting point of T2 electricity time e Press MODE button between LCD display display on T1 and kwh mean the electricity consumption of period T1 now press the SET CLR key to set the Price of Electricity of T1 e Press MODE button LCD between display on T2 that means power consumption of T2 now press the SET CLR button to set the electricity price of T2 time Avoid operating under adverse environmental temperatures and near flammable gased vapours and dust For reasons of safety never allow the device to be operated when wet or in a damp environment When cleaning or servicing the device must be disconnected from everysource of operation volatge Condesers in the device may still be charged even if the device was disconnected from all voltage sources In schools training facilties hobby and self help workshops pualified personnel must supervise the operation of measurement units In commercial institutions make sure you observe the accident prevention regulations of the commercial trade organization for electric installations Do not insert needles metals or any oteh objects into the device If it has been ascertained that safe operation is no longer possible take the device out of opertation and secure it against accidental reactivation It can be ascertained that safe operation is no longer possible if the devive shows visible damage no longer work