        SL6E CD OPERATING INSTRUCTIONS
         Contents
1.  C for RUN and 4  C for END    Factory Test    To run the factory test  hold the SELECT button when first applying power  the unit will perform  a series of self diagnostic functions with the pump running    If there are any faults they will be reported on the display before the unit restarts into normal  operation        Note  that this will force all settings to a factory default state  Re enable time clock if required  also set the Pump Load value  temperature limit and operating mode to their required settings     
2.  ingress    Any excess cable should be removed and re fitted ensuring that the wire ends are tinned  with solder     SL6E CD INSTALLER SETTINGS    PUMP LOAD SETTING      IMPORTANT     The controller will not operate and will display a     INSTALLER MUST SET PUMP LOAD    message  The correct Load setting is required for this  controller to pick up a pump which is failing to prime  After setting the load values test by  starting the solar pump in Manual Mode and ensure that the solar pump will switch off if the  filtration pump fails to provide water    Filtration Pump Load Automatic Setting  There are 2 methods for setting the load detection of  the filtration pump  For automatic setting ensure the filtration pump is operating and primed   Then simply hold the UP button then press SELECT  the unit will then display the pump   s load  value and automatically sets the threshold levels and returns to automatic operation  if the  current draw of the filtration pump drops below this level then the solar pump is forced to  switch off    Advanced Settings  To select the advanced settings  hold the DOWN button then press SELECT    Filtration Pump Load Manual Settings  If setting the load value  please ensure your filtration  pump is connected to the auxiliary power socket  right hand side  and that the filtration pump  is primed and if it   s a variable speed pump ensure the filtration pump is operating at the  required speed  After releasing the SELECT button the LOAD xxx value is di
3.  this will most likely occur  at night and therefore requires the filtration to run at night  and will attempt to cool the pool to 1  C above  the temperature limit  Normal heating will occur the next day if the pool drops below the set temperature  limit by 1  C    Settings mode is for setting the unit into time clock operation    When you select this option you will be asked if you wish to use the clock feature  CLK  ON OFF   If you  select OFF then the controller will not work as a time clock model and will allow the solar pump to run  whenever there is solar heating available and if the filtration pump is operating  If you select ON you will be  prompted to set the time of day  the controller will work in time clock mode and the solar pump is  prevented from starting outside of the set hours  Unless tropical mode is selected   Set the time of day in  24 hour format  note there is an AM PM indication to avoid incorrect settings  Seconds are automatically  set to zero  Once the time is set select the START hour from 6am till noon  default is 9am which means the  solar pump cannot start before 9am  Now select the END hour from 15  3pm  till 21  9pm   default is 19   7pm  which means the solar pump will stop at 7pm     SL6E CD INSTALLATION INSTRUCTIONS    CONTROLLER  Find a suitable location to mount the control box  The controller should be  installed out of direct weather and no closer than 3 meters from the water   s edge  Lift up the  two mounting tabs and use two appropr
4. NOTES    1  Ifa sensor fault is detected the controller will display which sensor failed  POOL and or ROOF  and  the type of failure    2  After a power outage all configurable items are retained  amp  the clock  if used  will keep time for up to  14 days    3  Temperature sensors used with this unit is digital and is accurate to 0 5  Celcius  no calibration is  required    4  The sensor cable with the thin trace is the positive and is fitted to the right hand side of the plug  when looking at the plug screws  incorrect polarity will be displayed as a short circuit or reversed  fault    5  A filtration pump that uses too much current can bring up an OVERLOAD condition  Disconnect  power  amp  check the condition of the filtration pump  this will prevent the solar pump from running    6  When the auxiliary power socket detects the filtration pump starting it will perform a 3 minute  checking sequence that ensures there is suitable temperature  amp  water flow before the solar pump  will start  When the filtration pump is stopped the solar pump is also stopped    7  Pump load values displayed is relative to how much power is consumed by the pump  note that  variable speed pumps tend to display higher than expected values    8  Maximum rated output load for the 240V socket is 10 Amps   2400 Watts     WARRANTY    This range of product is covered by a limited 2 year warranty against component failure or faulty  workmanship from the date of installation  A faulty unit should be ret
5. and insulate this section  some  ambient differences can travel up the tinned copper wire and affect the sensor reading     The roof temperature sensor must be fitted into a small piece of solar collector or equivalent  and attached to the roof  The best location is within an arms length of the gutters edge of the  house or shed as long as the sensor end is not shaded and is on a roof of similar aspect of the  main collector  It must not be fitted on top of the solar collector or fitted to high points on the  roof like Ridge Capping as false readings will be detected    The sensor plug is to be fitted to the right hand socket marked ROOF  Keep in mind that it is of  the utmost importance to keep the roof temperature sensor cable as short as possible as this  will assist in the longevity of the sensor and controller in the event of electrical storm activity  and power surges    All temperature sensor cables must NOT be run parallel to power cables and should never be  cable tied to power cables  All cable run lengths should be less than 50m if possible  Cable ties  should be used to fasten the sensor cable to the cold water inlet pipe making sure that the ties  are approximately 10mm from PVC fittings  Cable ties should be tightened only firm  over  tightening can cause breaks in the outer PVC if not careful  If the cable is to be run under  ground a conduit must be used to protect the wire and there is to be no cable joins within   conduit ends must be sealed to prevent water
6. iate screws to mount the control box to the wall   keeping in mind that the power cable is 1 8m long and should be plugged directly into a general  power outlet  not into an extension lead  Do not drill through the box     SOLAR PUMP  The solar pump plugs into the left side 240Vac socket marked as PUMP  Note  that the solar pump can only operate when the auxiliary power socket uses sufficient power to  trigger the current detection circuit  this detection trigger point can be adjusted  see Installer  Settings      FILTRATION PUMP  An loniser Chlorinator or equivalent pump timer is to be plugged into the  right hand side 240V socket  auxiliary  located under the POOL  amp  ROOF sensor inputs  the  filtration pump plugs into the loniser Chlorinator pump socket     TEMPERATURE SENSORS  The pool temperature sensor must be fitted into the suction line of  the filtration pump  as close to the pool as practical  preferably in a position out of direct  sunlight  It is recommended that a 14 5mm hole be drilled in the PVC pipe  this can be carried  out using a Dontek PDO1 grinding drill or a small pilot hole can be drilled and a 14 0mm drill bit  used spinning in a counter clockwise direction to minimize the chance of shattering pipe  Insert  the grommet into the pipe and gently push in the black sensor barb  The green sensor plug is to  be fitted to the plug socket marked POOL  in some cases there is some benefit to cable tie  30cm of wire from the pool temperature sensor to the pipe 
7. splayed for 5  seconds  take note of this value  When the LCD screen displays RUN  gt xxx it indicates the  minimum load required to allow solar to run  set this value 10  lower than the displayed LOAD  value and press SELECT  The next value to adjust is TRIP gt  this is the overload value  when the  filtration pump draws too much power  e g  a variable speed pump operating too fast  then the  solar pump is stopped   Default is a RUN  gt 20 and trip  gt 99    Once the Advanced settings have been adjusted all the above settings will be saved and the unit  will restart  Re adjust the temperature limit if required    Adjustable differential  Special note  Adjusting these values to any setting other than the  defaults may adversely affect the performance of this controller  To adjust the differentials hold  the UP button while applying power to the unit  The first item prompted is to set the solar gain  start temperature  RUN   x  this setting allows the pump to start if the roof temperature  exceeds the pool temperature by this value  adjust with the UP DOWN button  press SELECT to  accept  Next you will be prompted to set the differential hysteresis  END   x  which turns the  pump off when roof temperature is less than the pipe temperature plus this value  adjust with  the UP DOWN button  press SELECT to accept  Default values are 8   for RUN and 4   for END   these are the optimal values for maximum efficiency  some coastal locations may benefit from  a reduced run value of 6 
8. urned in the first instance to the  dealer from which the unit was purchased    Damage to the unit due to misuse  power surges  lightning strikes or installation that is not in accordance  with the manufacturer   s instruction may void the warranty    Warranty does not cover travel costs to or from installation site    If the power cord is damaged  do not use the controller  return the unit to the supplier for repair     Customer Record   To be retained by the customer     Dealer Installer Name       Serial Number       Date Installed       For service assistance phone SUNLOVER HEATING    VIC 03 9887 2131  NSW 02 9838 0000  QLD 07 5597 7360   Factory 6 Unit 2  62 Parkhurst Drive  7 9 Activity Crescent  20 22 Foundry Road   Knoxfield 3153 Molendinar 4214 Seven Hills 2147  Victoria Australia Queensland Australia NSW Australia    www sunloverheating com au  SL6E CD Instruction rA6 doc        P    _ Sunlover  LYS heating    SL6E CD OPERATING INSTRUCTIONS    DESCRIPTION  The SL6E CD is a premium automatic solar controller with temperature adjustment  manual   winter and tropical mode features  This unit is fitted with current detection on the auxiliary power socket   the solar pump can only operate if the current load on the controllers auxiliary socket is within a certain  range  e g  filter pump is operating and primed      TEMPERATURE LIMIT    To adjust the pool limit simply press the UP button to increase or the DOWN button to decrease the desired  temperature  The controller 
9. will automatically choose to run the pump based on solar gain  i e  sun shining   amp  roof is hot   once the pools desired temperature is exceeded by    C the pump is stopped until the pool  temperature drops    C below the temperature limit setting     MODE of operation    Pressing the SELECT button once will display the current mode of operation  pressing it again or holding it  will select the next available mode of operation    The available modes are SUMMER  MANUAL  WINTER  TROPICAL and SETTINGS     Summer mode is the normal operating mode for heating the pool    Manual mode is for testing the pump installation on a cold or cloudy day  Once manual mode is selected  the pump will start if it has been off  or stop if it has been on  running   After 30 minutes manual mode will  time out and return to the previous operating mode  Note that Manual ON requires an operating filtration  pump in the auxiliary power socket    Winter mode of operation is for off season maintenance or if pool heating is not required  AWAY MODE    This is a better option than turning off the controller as it will flush treated pool water through the solar  system as well as prolong pump bearing and mechanical seal life  The pump will run for 3 minutes once a  day 3 minutes after the filtration pump has started    Tropical mode of operation is for situations where the pool water overheats due to direct heating from the  sun  When the roof is 4  C cooler than the pool temperature  the pump is started 
    