Contents
1. 12 At walipad A All room sensor failure 13 Water pump float switch failure 14 Low safety thermostat failure 15 Communication failure 16 Hydronic pump switch failure 17 Page 10 Troubleshooting Air Conditioner Doesn t Operate 1 Check there is power to the air conditioner There is no power if the SAT 1 s screen is blank 2 Check the SAT 1 is on i e the LCD display is on 3 Check if symbol is displayed If so checked that you are in the switch on period or alter the timer settings refer to page 6 Reduced Cooling or Heating 1 Check the SAT 1 is not in the SLEEP mode refer to page 6 2 Check to see if the air filter if any requires cleaning 3 Check if any doors or windows are opened 4 Check that there are no obstacles in front of the outdoor unit No Cooling or Heating Check that the correct operating mode has been selected Auto Cool Heat The preset temperature may have been set too high or too low If the set temperature appears okay call for service Timer is Not Correctly Triggered Check the clock is set to the right time day light saving and the timer has been correctly programmed Loss of Settings If the SAT 1 fails to retain the preset timer settings when the power supply is off then check the battery to see if it needs replacing If the battery is flat low or missing the LCD display will still operate however the clock will reset to 0 00 SUN settings The battery is
2. Off button Press once to start operation Press again to stop operation To select day of week Sunday to Saturday Or used in weekly on off timer programming to select day of week Timer button Press to activate on off timer programming mode Room temperature setting button Fan speed button Press to select low medium high or auto fan speed Time setting button To adj ust the RTC setting or used in on off timer programming to adjust timer setting Mode button Press to select cool fan dry heat or auto operation mode Page 4 Sleep butto Swing button Timer cancel button To cancel on off timer setting in timer programming mode n Press once to select sleep mode Press again to cancel sleep mode Operation On Off Starting Operation as When the unit is turned off press the button The backlight and the system are turned on Bypass Operation To activate the air conditioner outside any pre set times follow the instructions in page 7 Stopping Operation When the unit is turned on press the 27 button The system is turned off Room Temperature Adjustment Normally the display will show the current room temperature not the preset temperature Set the temperature of your choice by pressing the or ES buttons The preset temperature will appear Each push will change the temperature by 1 C
3. Setting Clock TIME A A a Press a or TIME button to enter clock set mode clock symbol flashes TME N b Press Y or TIME button to increase or decrease the clock setting in 1 minute Hold down the button to change the setting at a faster speed C Day N c Press button to change the set day Setting 7 Day Timer The timer can be set to turn on and off two sessions per day and one regular session per week On or Off Timer Setting TIMER RU a Press button to select on timer or off timer If on timer is selected ON symbol and set day flashing If off timer is selected OFF symbol and set day flashing b There are 2 sessions of on or off timer available per day Press or LD button to select session 1 P1 or session 2 P2 The selected session is indicated on the temperature display area as P1 or P2 Cary c Press gt button to change the set day of the on or off timer d If the selected timer for the set day is empty timer display area shows a otherwise the on or off timer setting will be shown TIME GN ap e Press w or TIME button to change the on or off timer setting Hold down the button to change the setting at a faster speed f Symbol lights up to indicate there is on or off timer being set CANCEL g Press 7 key to cancel the current on or off timer being set timer display area shows h Repeat step a to e until the desired ti
4. located at the rear of the SAT 1 Separate the thermostat body from the wall mounting plate by removing the screw attaching both pieces as picture below F Use screw driver to ER 20 p SB remove the locking Remove the back cover screw Insert the battery into the battery holder Remove and check the battery If necessary replace with a lithium CR2032 cell battery Page 11 Keypad Will Not Respond Check to see if key lock symbol wO is displayed Refer to page 7 for unlocking procedure Remote Control Doesn t Operate 1 Check the batteries in the remote control aren t flat 2 The infra red remote control must be pointed directly at the SAT 1 wall thermostat plaque in order for its signal to be received 3 If there is no light or beep from the wall plaque when the remote controls buttons are pressed consult your installer to ensure the wall plaque has been set up correctly for remote control use Page 12 temperz AUCKLAND Temperzone Ltd Phone 0 9 279 5250 Fax 0 9 275 5637 SYDNEY Temperzone Australia Pty Ltd Phone 02 8822 5700 Fax 02 8822 5711 SINGAPORE Phone SNG 6733 4292 Fax SNG 6235 7180 Your local service agent is 2742 02 08
5. temperature display area Letter H indicates hour setting b Press dj c Press CANCED button will cancel the bypass timer setting d System will exit from bypass setting 3 seconds after last key press If Bypass timer is set the display will alternate between temperature and number of countdown hours left e g 8H and the room temperature Upon Bypass timer countdown reaching zero a If the On or Off timer settings are nil system will switch off b If there is On or Off timer available the unit will continue to operate if the time span of the On or Off timer allows it to be on At an undefined region or off time span the unit will switch off E2 to set the bypass timer setting anywhere from 0 to 9 hours Ca To terminate the bypass timer before chosen time has finished press button to cancel the setting and turn off the air conditioner Buzzer Buzzer beeps in response to a valid button press or wireless signal reception It beeps twice when the system is turned on otherwise beeps once to all other valid acknowledgements Backlight Backlight colour changes according to the operating mode setting Operating Mode Backlight Colour Cool Blue Fan Yellow Dry Pink Heat Reddish orange Auto Light violet a The colour changes to red whenever there is system fault Whenever the fault is cleared backlight colour will return to original b If the unit is on backlight wi
6. Temperature can set within the range 16 C 30 C During Fan mode the temperature can not be set Mode Selection Press the PE button to switch operation between Cool Fan Dry Heat and Auto The display shows which mode is selected at any one time Cool If the room temperature is too warm the air conditioner cools the room until it reaches the set temperature Dry If the atmosphere in the room is very humid or damp use this mode to both reduce the humidity and cool until the room is near the set temperature Heat If the room temperature is too cool the air conditioner warms the room until it reaches the set temperature reverse cycle systems only Auto The air conditioner will automatically cool or heat the room until it reaches the set temperature reverse cycle systems only Fan If the atmosphere in the room is stale use this mode to circulate the air in the room without changing the overall room temperature Fan Speed Selection Press 2 button to select Auto High Medium or Low speed Auto The SAT 1 will automatically select the most suitable fan speed to maintain set temperature High Medium Low A choice of three manually selected fan speeds are available Swing Activation This function is only applicable to systems with under ceiling indoor units Press button to activate the air louver sweep function or to set the louver at a preferred angle Page 5 Time Functions
7. Y tempe zone SAT 1 Thermostat kG OKA ZS FAN DRY HEAT AUTO a Ju Oo A SLEEP SWING ZONE o a SUN MON TUE WED THU FR SAT T HEATER OOO ie 7 EF 7 a N TIMER ZEN ZON E D 3 CAN CED USER S OPERATING INSTRUCTIONS a ai e nakua soeke nowa aladation and will therefore be inacii Page rience Ri eer ae 3 Features Summer 3 Display EE 4 Operation EE 5 Remote Control option me 9 Error Code Display reer eee 10 Troubleshooting mm 11 Contact for Service back page Introduction Your temperzone air conditioner is supplied with a SAT 1 wall thermostat This thermostat has been designed to maintain a high level of comfort for room occupants Emphasis has been placed on providing controls that are easy to use despite the sophisticated microprocessor system that runs it Use of the Auto and Timer function settings allows you to set it and forget it Features Summary eCool Dry Fan modes Heat Auto modes Reverse Cycle Systems only Backlighting display with different colour indicating different mode of operations eAuto High Medium Low fan speed selection e Temperature setting range from 16 C to 30 C Room temperature display Real time clock 7 days programmable Start Stop timer that programs the unit to two start stop sessions per day Bypas
8. erature to provide a more confortable sleep ie for use in bedrooms Swing Press to activate or deactivate the air louver sweep function NB This function is only applicable to systems with under ceiling indoor units Clock Pres down or up button for Page 9 2 seconds to activate The current clock setting will decrease or increase at minute intervals on each press The speed of interval updating increases after 4 seconds of continuous key press It will update at high speed after 6 seconds of continuous key press Error Code Display 1 Should there be any fault happen with the main board the relevant error code will be shown on the error display area and symbol ERR will light up 2 If there are multiple faults happening at the same time the error codes will be shown one after another 3 The error codes are Fault Error code Remarks Room sensor 1 failure 1 Main board AD3 Room sensor 2 failure 2 Main board AD4 Room sensor 3 failure 3 Main board AD5 Room sensor 4 failure 4 Main board AD6 1 indoor coil sensor failure 5 Main board AD1 1 outdoor coil sensor failure 6 Main board AD2 1 insufficient of refrigerant 7 1 compressor overload 8 1 low pressure failure 9 1 high pressure failure 10 Room sensor 5 failure 11 At walipad B Room sensor 6 failure
9. ll turn off 30 seconds after the last button press c If the unit is off any button press will turn on the backlight and the screen display The backlight will turn off 10 seconds after last button press Once the backlight is turned on setting can be done the same way as when the system is on Page 8 Remote Control option Operation A beep will sound when the wall plaque receives a signal from the hand held infra red remote control The IR remote control must be pointed directly at the SAT 1 wall thermostat plaque in order for its signal to be received di KU Fan Set Temperature Clock EERE Adjust Set Temperature Press down or up button to decrease or increase the desired room temperature Heat Signal gt pa x A al bk Sleep t Sp AUTO d ail BE aiB BBm sor Note A temperature can not be set in Fan mode Mode Press this button will advance the mode in the following sequence Cool Dry Fan Heat Auto Fan Press this button will advance the fan speed as follows Auto Low Medium High Under Fan mode only low medium and high are available Under Dry mode fan speed will be inhibited and will not be displayed AN ON PM OFF Swing On Off _ Press to switch on or off the air conditioner Sleep Press to activate the energy saving Sleep function which automatically adjusts the temp
10. mer for each session and each day have been set i System will save and exit timer settings 6 seconds after last key press j In non timer set mode hold down Com key for 5 seconds will cancel all the on or off or override timer being set Page 6 Example Two sessions of on and off timer per day being set as follow P1 on timer 0800 P1 off timer 1200 P2 on timer 1300 P2 off timer 1700 If current time is 0730 hrs it will remain as last state At 0800 hrs it will turn on the unit using P1 on timer At 1200 hrs it will turn off the unit using P1 off timer At 1300 hrs it will turn on the unit using P2 on timer At 1700 hrs it will turn off the unit using P2 off timer Pressing on off button to on off the unit will bypass the control of current event The second event will take over upon expiry of current event Example If user turns off the unit at 1000 hrs it will remain off until 1300 hrs at which time control is taken over by timer P2 Sleep Activation GL EEP Press button to activate the sleep option This option saves energy by altering the set temperature over a two hours period Example uses In Summer before going to bed at night with the cool mode set pressing the GL EEP button gradually raises the set temperature by 2 degrees to compensate for a person s lower metabolism when sleeping In Winter with the heat mode set pressing the SLEEP button gradually lower the
11. s function enables user to bypass the on off button and any user programmed times for immediate operation of the air conditioner Battery backup In the event of a power failure a backup battery will maintain the real time clock and the integrity of the control s data When power is resumed returned switched on again the unit will automatically restart using the last settings Key lock function prevents unauthorized personnel from changing the settings of the wall thermostat Sleep function Air swing function Zone control option Buzzer beeping to acknowledge valid key entry or wireless remote handset reception elnfra red remote controller option Page 3 Display Tem Display set or room Day display area perature display area emperature Display day of week SUN MON Monday WE Wednesday THU SAT Infra red reception To receive wireless handset signal Sunday TUE Tuesday FRI Thursday Friday Saturday Operation display Fan speed displa de AUTO Auto fan de de o Low y o OU Medium d ua 2 0 Key lock Timer display area Dislay on off timer or real time clock RTC 5 ON On timer O OFF Off timer Day button ER Op UNIT amp OO L Error display area Display error code ERR Error display On
12. set temperature by 3 degrees to compensate for heavier winter bedding The sleep option is only available for Cool Heat and Auto modes Zone Control option If your air conditioning installation has zones installed i e dampers select the zones to be turned on using the appropriate Zone button Zone 1 is always assigned as master zone Each zone can be individually turned on or off However zone 1 can only be turned off provided there are two other zones turned on Key Lock This feature protects the control being tampered with by children or unauthorized persons A To activate hold down TIME and lt d MODE buttons for 3 seconds key lock symbol TO will light up When th the key lock is active button can be used to on or off the system Di or gt button can be used to program the Bypass timer refer below o S ED can be used to cancel the Bypass timer Other buttons are ignored K A c NI d Page 7 To cancel the key lock hold down TIME af MODE 4 buttons for 3 seconds key lock symbol TA Bypass This feature provides a quick on demand alternative to the pre programmed type of use Bypass operation permits the user to start the air conditioner will no longer be displayed aly immediately bypassing the button and any programmed session times Bypass is initiated by oC xX fl a Hold down J or E 1 button for 3 seconds will be shown at the
Download Pdf Manuals
Related Search
Related Contents
GW 40 251 GW 40 261 GW 40 271 GW 40 256 GW 40 Installation and Operating Instructions for Asustor AS5004T WaWi Handbuch 『防護柵の設置基準』の主な改訂点 K & S ELETROELETRÔNICA KESSP 広報おち2015-3月号〔PDF〕 Behringer U-Control UMA25S Brochure Installation Guide FX1 MIDI Footcontroller User Manual (Rev. 4) Copyright © All rights reserved.