Home

USER'S MANUAL

image

Contents

1. 8 9 Disarming aies AT 10 Resetting 5 nnne 10 Monitor an ue aevo Des oe o REL 11 EE 12 PUIG SS E 12 13 Medical 13 EXGIUGING ZoNe S uiii a 14 re 15 OPERATION by RADIO KEY 16 PROGRAMMINQ dea ek x cacti 17 Programming Options Table 17 User Code programming 18 Entry Exit Timer programming 18 Telephone Number programming 19 Monitoring Central 20 Monitoring Audible eere 21 Wireless Accessories 20 Remote Operation by Telephone 22 NESS ACCESSORIES i iiber Ive vict 24 Wireless Accessories 25 Troubleshooting nere 26 Iristallatlon iacit 27 OPERATION SUMMARY 28 Technical Manuals Online http www tech man com NESS 08 FEATURES 8 Fully programmable zones Any combination of hardwire or radio zones Fu
2. KEYPAD BEEPER SOUNDS Each key press 2 1 beep Valid command 444 3 beeps Mains Power is off or 2 L 9 L 10 beeps Panel Battery is low NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com OPERATION This section describes the operation of a typical control panel installation Keep in mind that your installation may vary depending on the selected options and equipment The operating instructions which follow will cover the most common options Consult your installation company if you require further information All control panel operations are controlled by the D8 LED or LCD keypad except if an optional key switch or radio control equipment is installed OPERATING RULES Generally the panel will be Disarmed Armed or Monitor modes provide different levels of security for your premises when you are home or away Three other temporary modes Program Memory and Exclude allow you to perform various operations The panel will automatically exit from these temporary modes if you do not press any buttons on the keypad in a 4 minute period If you make a mistake while entering any codes press the Enter or E button and start again When you are required to enter your access code you are given five opportunities to enter it correctly After the fifth invalid attempt the alarm is activated requiring the correct code to silence the alarm This prevents anyone tryin
3. 7 or User Code C ENTER The Armed light will turn on eave the premises within the Exit Delay Time 3 beeps will sound at the end of Exit Delay Time The control panel must be Armed prior to vacating the premises in order to detect intruders Ensure that the panel is not in Program Memory or Exclude modes Note If the panel is already in alarm you must first silence the alarm before you can Arm If something is wrong when Arming the control panel the normal 3 beeps will be replaced by other warnings J 10 10 beeps means Mains Power is turned off or the Backup Battery is low a One long beep indicates an invalid entry or an alarm is outstanding and needs to be reset by entering your User Code first NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com OPERATION LCD KEYPAD The Not Ready light must be off Press CARM E ae Or User Code The 5 ARMED icon will turn on eave the premises within the Exit Delay Time 3 beeps will sound at the end of Exit Delay Time SIREN WARNING At the end of the exit time all zones should be Sealed If any are Unsealed the siren will sound for 2 seconds as a warning to indicate that those zones have been automatically excluded For maximum security you should return Disarm check the premises and then Arm again Continual warnings could mean that a detector
4. Only the zones which have been programmed by your installer as Monitor zones will be Armed If an alarm occurs while in Monitor mode entering User Code will silence the alarm This will also Disarm the panel so remember to enter monitor again if needed By using the optional Radio Keys you can enter Monitor Mode by pressing the OFF button twice within 4 seconds Your installer must enable Radio Key Monitor Arming for this to work OPERATION KEYPAD PANIC LED KEYPAD Press Both keys together Or C Panic User Code ENTER Or C PANIC ENTER If Keypad Panic Shortcut has been enabled by your installer The keypad PANIC function may have been programmed to be either AUDIBLE activates siren or buzzers or SILENT If your system is monitored by a Central Station sends a PANIC report by dialler If PANIC reports have been enabled by your installer LCD KEYPAD Press C D C 2 Both keys together Or C 2 User Code CE or If Keypad Panic Shortcut has been enabled by your installer PANIC cannot be used while the panel is in Program Memory or Exclude mode Note Your installer may have installed a separate PANIC button To activate the panic alarm simply press that button KEYPAD DURESS ALARM LED KEYPAD Press 9 User Code Disarms and sends a Duress Alarm report by dialler 1 If your system is monitored by
5. P28E 60 seconds 1 to 99 sec Up to 15 digits NOTE The Entry Delay 2 timer programs in 10 second intervals Example if a value of 6 is programmed the time is 60 seconds NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com PROGRAMMING PROGRAMMING USER CODES LCD KEYPAD LED KEYPAD Press CP Master Code 2 Enters Program Mode The PROGRAM light will be on Press P Option No CE i The two digit option number for the code to be programmed The existing code if any will be displayed dad Q Press NEW cone NEW CODE E Enter the new code twice The new code will be displayed Press P E To exit Program Mode Press Master Code Enters Program Mode The PROGRAM light will be on Press Option The two digit option number for the code to be programmed The existing code if any will be displayed Q Press NEW CODE J NEW CODE ddd Enter the new code twice The new code will be displayed 22 Press Poo ENTER To exit Program Mode EXAM PLES The panel must be in Program Mode Program light ON To program User Code 1 The Master Code to be 1234 P11E 1234 E 1234 E To program User Code 2 as an ARM ONLY code to be 5678 P12E ARM E 5678 E 5678 E When an Arm Only code is displayed the ARM light or icon is displayed
6. Press NEW TELEPHONE NUMBER The new telephone number will be displayed dd Press Procrav C ENTER To exit Program Mode Press NEW TELEPHONE NUMBER E The new telephone number will be displayed Q Press P E m To exit Program Mode EXAM PLES The panel must be in Program Mode Program light ON To program the Follow Me Telephone Number to be 9123 1234 POOE 912341234 E To DELETE the Follow Me Telephone Number POOE MEMORY E Fora list of option numbers see the Programming Options Table on page 17 To enter PROGRAM MODE To exit PROGRAM MODE Master Code ENTER ENTER P Master Code E P E NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com MONITORING CENTRAL STATION MONITORING TELEPHONE LINE MONITORED PREMISES MONITORING STATION CENTRAL STATION MONITORING The D8 control panel has an on board digital dialler which can send detailed alarm messages to a Central Monitoring Station The digital messages can include information about the zone or zones which caused the alarm tamper alarms low battery or mains failure reports and it can also by user number identify the users who Arm and Disarm the system Central Station Monitoring is highly recommended and is the most effective method of monitoring your D8 alarm system For further information about 24 h
7. followed by the digits of the code PROGRAMMING TIMERS LED KEYPAD LCD KEYPAD Press rocram Master Code ENTER gt P Press P Master Code pe Enters Program Mode The PROGRAM light will be on Enters Program Mode The PROGRAM light will be on JJJ Press Option No ENTER Press P Option No CE The existing time will be displayed The existing time will be displayed ddd dad Press NEW TIME ENTER Press NEW TIME The new time will be displayed The new time will be displayed dad 22 Press rocr _ ENTER Press P E To exit Program Mode To exit Program Mode EXAM PLES The panel must be in Program Mode Program light ON To program Entry Delay Time1 to be 15 seconds P26E 15 E To program Exit Delay Time to be 40 seconds P28E 40 E KJ NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com PROGRAMMING PROGRAMMING THE FOLLOW ME TELEPHONE NUMBER LED KEYPAD LCD KEYPAD Press CP Master Code Enters Program Mode The PROGRAM light will be on Press P Option No CE E The existing telephone number if any will be displayed ddd Press Master Code Enters Program Mode The PROGRAM light will be on Press Option No 22 The existing telephone number if any will be displayed JJ
8. D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com NESS RADIO KEY PENDANT Fully waterproof pendant style transmitter can be used as a portable wireless Panic button Supplied with a neckchain as well as wristwatch straps Ideal for use as a medical alarm for the elderly or infirm Central Station Monitoring is especially recommended when used for medical alarm purposes Includes long life lithium battery NESS RADIO REED SWITCH Ness Radio Reed Switch for wireless door and window protection Includes long life lithium battery NESS RADIO KEY 3 BUTTON Fully waterproof ultra slim 3 button Radio Key for remote control of the control panel With separate buttons for ON Arm OFF Disarm and PANIC functions Includes long life lithium battery NESS RADIO SMOKE DETECTOR Radio Smoke Detector using lonisation smoke detection technology With on board sounder A single battery powers the smoke detector and the transmitter Includes 9V lithium battery TROUBLESHOOTING SYMPTOM Zone light on or long beeps when Arming 10 beeps from keypad MAINS light flashing BATTERY light flashing 1 long beep from keypad 2 second siren at the end of Exit Delay time Strobe light is flashing Siren sounds while the panel is Disarmed EXCLUDE light is flashing TAMPER light flashing ALARM MEMORY light is flashing Cannot enter Program Mode POSSIBLE CAUSE One or more Zo
9. INEZ DS NESS D8 ALARM CONTROL PANEL AND DIALLER MADE AUSTRALIA UM USER S MANUAL NESS D8 CONTROL PANEL V4 USER S MANUAL REVISION 1 A 12 00 INC GST Versions commencing November 2001 Technical Manuals Online http www tech man com Australia s largest designer and manufacturer of high quality security products N55 NESS SECURITY PRODUCTS Australian Communications Authority TELECOMMUNICATIONS COMPLIANCE Quality Endorsed Company ISO9001 LIC No QEC2074 NSW Head Office only INEJ Ness Security Products Pty Ltd WWW NESS COM AU HEAD OFFICE Ness Security Products Pty Ltd ACN 069 984 372 4 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph 61 2 8825 9222 Fax 61 2 9674 2520 ness ness com au SYDNEY 02 8825 9222 MELBOURNE 03 9878 1022 BRISBANE 07 3343 7744 ADELAIDE Aquavia Controls 08 8277 7255 PERTH 08 0328 2511 NEW ZEALAND NFS NZ 64 9 573 0401 D8 V4 USER MANUAL Revision 1 November 2001 Document Part Number 890 264 For products 100 191 D8 LED Control Panel V4 100 688 D8 LCD Control Panel V4 2001 Ness Security Products Pty Ltd ABN 28 069 984 372 D8 V4 User revi pmo231001 Specifications may change without notice Technical Manuals Online http Awww tech man com CONTENTS qe MT T 4 Jail eres re nep 5 KOYDA MER REM 6 KEY Dad IndiealOES dude eine certae 7 OPERATION by KEYPAD
10. These options can only be accessed from Program Mode User Codes may need to be re programmed if a person has forgotten their code to give a new user access to the system or to give someone temporary access User Codes 2 15 can be set as Arm Only Codes These codes can Arm but cannot Disarm the panel Useful for assigning to cleaners tradesmen etc You may need to change the Entry and Exit timers if you find the delays are too long or short PROGRAMMING OPTIONS TABLE If Audible Monitoring is programmed by your installer the Follow Me Telephone Number is the telephone number the dialler will call in the event of an alarm If your Ness D8 panel is monitored by a Central Station the Follow Me number is ignored For all other programming changes talk to your installer The panel will automatically exit Program Mode is no buttons are pressed within a 4 minute period FACTORY DEFAULT MASTER CODE IS 123 FACTORY OPTION OPTION No DEFAULT 8 PROGRAMMED User Code 4 User Code 5 User Code 6 User Code 7 User Code 8 User Code 9 User Code 10 User Code 11 User Code 12 User Code 13 User Code 14 P24E P17E 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits 3 to 6 digits User Code 15 P25E 83to6 digits Entry Delay 1 P26E 20seconds 110 99 sec Entry Delay 2 Follow Me Telephone No 10 to 990 sec Exit Delay
11. a central monitoring station 2 If Duress Alarm Report has been enabled by your installer Duress Alarm can be programmed to sound the RESET output 1 By default Duress Alarm does not sound the RESET output Digits 5 6 amp 8 in front of the user code can also be used trigger the Duress alarm LCD KEYPAD Press 9 User Code Disarms and sends a Duress Alarm report by dialler 1 If your system is monitored by a central monitoring station 2 If Duress Alarm Report has been enabled by your installer Duress Alarm can be programmed to sound the RESET output 1 By default Duress Alarm does not sound the RESET output Digits 5 6 amp 8 in front of the user code can also be used trigger the Duress alarm A DURESS alarm can be triggered to alert the Central Station that you are being forced to Disarm the panel against your will DURESS alarms are only used if your system is monitored by a Central Station DURESS 15 NORMALLY NOT ENABLED TO ENABLE THE DURESS FUNCTION CONSULT YOUR INSTALLER To Disarm and send a DURESS alarm prefix your User Code with one of the digits 5 6 8 or 9 when Disarming E NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com LED KEYPAD Press sounds the siren Fire Alarm siren sound 1 If Keypad Fire Alarm has been enabled by your installer Sends a Fire Alarm report by dialler 1 If your system is
12. is faulty and may have to be manually excluded If the auto exclude option is disabled the siren will sound for the duration of reset time if a zone is Unsealed at the end of exit time OPERATION DISARMING LED KEYPAD Enter the premises through a delay zone Press User Code 20 The Armed light will turn off When you enter the protected premises through a delay zone the keypad responds with regular beeps as a reminder to Disarm You then have your programmed entry delay time to Disarm the panel by entering one of your user codes If the panel is not Disarmed by the end of the entry delay time an alarm will occur By using the optional radio keys you may Disarm your system from within your premises RESETTING ALARMS Your panel can be reset and the alarm silenced by the same key sequence as Disarming the panel If you arrive at your premises and find the strobe light flashing if installed reset the panel as above To check the cause of the alarm you can view the alarms in memory by entering Memory Mode LCD KEYPAD Enter the premises through a delay zone Press User Code E JJ The 5 ARMED icon will turn off or from outside your entrance door There is also the option to Chirp the outside siren three times and to flash the strobe light for two seconds as an indication that you have Disarmed your system If you make a mistake in entering you
13. ALARM CONTROL PANEL Telephone S Lr ZONE ASSIGNMENT 2 P26E ENTRY DELAY TIME 1 Seconds m Es 19e E ja m E Ss P27E ENTRY DELAY TIME 2 Seconds ud amp 5 m cc C d LLL a E o P28E EXIT DELAY TIME Seconds c cr X 05625 25 ine 2H Z lt 9 4 U P29E SIREN RESET TIME Minutes M M A cn oo T Q e T N LO N i te i i i N a a RADIO KEY CODE OPTION No CODE HOLDER CODE Y N dresses 1 User Code6 UerCodez ___ User Code8 LLL User Code 10 P20E ora UserCodei Pag fT User Code15 Pa ___ 2001 Ness Security Products NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com OPERATION SUMMARY OPERATION Ma LCD KEYPAD WDR GT Or User Code a User Code User Code User Code Q 90 2 Or User Code User Code Press twice within 4 seconds P69E 5E must be ON MONITOR MODE Both keys together Cx Cox 2 Both keys together or CED User Code CX User Code Cog Q _ __ Keypad Panic Shortcut Keypad Pan
14. DIO AFE er MONITOR BATTERY MAINS EXCLUDE PROGRAM LINE Not Ready light Not Ready buttons 135 ARM button MONITOR button EXCLUDE button MEMORY button PROGRAM button ENTER button Protective flap not shown The Not Ready light is on when the panel is not ready to Arm i e a zone is unsealed there may still be movement in the premises or a door or window left open DISPLAY TEST LCD Keypad only To display all the keypad icons press and hold the E button for at least 2 seconds All the icons will be on whilst the E button is held down Display Test can be activated at any time either in operating mode or any program mode NESS 08 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com KEYPAD INDICATORS STATUS e OFF O ON CX FLASHING LED KEYPAD LCD KEYPAD Zone is sealed Zone is unsealed Zone is unsealed or Power fault READY or System is Armed Ready to Arm or phone line fault Monitor Mode Zone alarm J m I IR E The panel s backup T Receiving radio sianal Indicates that a Radio Key or O RADIO RADIO And in Mos Mode other radio device has low battery alarm from a radio device low battery Phone line fault LINE LINE Dialler is on line PROGRAM PROGRAM User Program Mode Installer Program Mode UJ E x z U rri 20 gt
15. IO KEY OPERATION NESS RADIO KEY 3 BUTTON The optional Ness Radio Key allows you to Arm Disarm and activate PANIC The Radio Key can also Arm Monitor Mode if this has been enabled by your installer ARMING Press the ON button The keypad will give 3 beeps The outside siren will give 1 chirp If enabled by your installer The strobe light will flash briefly DISARMING Press the OFF button The keypad will give 3 beeps The outside siren will give 3 chirps If enabled by your installer The strobe light will flash briefly ARMING MONITOR MODE Press the OFF button twice within 4 seconds The keypad will give 9 beeps The outside siren will NOT chirp The strobe light will flash briefly PANIC Press and hold the PANIC button for at least 4 seconds The siren and strobe will activate If enabled by your installer The dialler will report a Panic alarm If enabled by your installer Q and if your system is monitored by a central station Press the OFF button to reset a Panic alarm The Ness Radio Key is optional and is not supplied with any Ness control panels as standard Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com PROGRAMMING Various system options as listed below can be programmed by the user
16. USER MANUAL Technical Manuals Online http www tech man com INTRODUCTION The Ness D8 micro computer based 8 zone control panel is the heart of your security system to which all your detection devices connect Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises Detection devices may be connected to the D8 control system directly by cabling or with optional wireless Radio devices Detection devices called Passive Infra Red Detectors or P J R s for short can detect the movement of an intruder by sensing their body heat PI R s are used to cover various critical areas of your premises where an intruder may enter or trespass Another detection device used is called a Reed Switch Reed Switches are attached to windows and doors to detect if a window or door has been opened A Reed owitch consists of a magnet which is normally attached to the moving part of a window or door and the Reed switch which mounts to the door or window frame The panel is Armed when it is set to detect an intruder At other times it is Disarmed Normally a zone is considered Sealed Activation of a detection device will cause the zone to be Unsealed and may cause an alarm Detectors such as fire detectors and panic buttons must be able to generate an alarm at all times regardless of the panel setting A zone with this assignment is called a 24 hour zone Some detection d
17. detector becomes faulty and cannot be Sealed when arming the panel then its zone may be Excluded so that it does not generate alarms When zones have been Excluded the EXCLUDE light flashes continuously while the panel is Disarmed and also when Armed Zones can only be Excluded when the panel is Disarmed NOTES LCD KEYPAD Press cuve E ee Or User Code ge 2 EXCLUDE icon will turn on Enter the zone number of the zone s to be Excluded Zone No E Zone No E The zone light of each Excluded zone will turn on Press E to exit Exclude mode Q The Z EXCLUDE icon will flash continuously Zone Exclude IS not permanent Excluded zones are automatically INCLUDED next time the panel is Disarmed Zones can be manually included by the same method as Excluding Simply use the ZONE NUMBER E sequence to turn OFF the zone lights to be Included EXCLUDE E works only when the panel is Disarmed EXCLUDE User Code E works in any state EXCLUDE User Code E can only exclude the zones in the Area assigned to that code EJ NESS 08 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com OPERATION VIEWING EVENT MEMORY LED KEYPAD ddd Press ENTER or User Code The Memory light will turn on Q Press The most recent event will be displayed Press The next m
18. ed by low tone PRESS 0 To prepare the 08 3 beeps PRESS User Code 4 to authorise the next command 3 beeps PRESS 1 st to Arm the panel 3 beeps PRESS to finish and hang up AUDIBLE FEEDBACK JJ 3 BEEPS The User Code is valid Successful Arming or Disarming An Auxiliary output has been turned ON J 11046 BEEP D8 is already Armed nvalid code Try again 1 SHORT BEEP An Auxiliary output has been turned OFF SUMMARY OF TELEPHONE COMMANDS 0 Prepare to receive commands 1 st Arm Areas 2 st Disarm Areas 3 st Turn Aux 1 Output ON or OFF 4 st Turn Aux 2 Output ON or OFF s Finished hang up NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com NESS ACCESSORIES MADE AUSTRALIA p C 5 100 021 100 226 100 210 100 048 Quantum Quantum Quantum Quantum 360 Plus Dual MOTION DETECTORS Ness manufactures a range of high quality and efficient motion detectors including passive infra red detectors dual technology microwave and infra red devices as well as ceiling mounted 360 detectors All Ness detectors are designed using the most modern technology and techniques that ensure superior reliability and performance PET AWARE DETECTORS The Ness Quantum Pet Aware PIR and Pet Aware DUAL are able to discriminate between household pets and unwanted
19. erimeter protection NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com WIRELESS PRODUCTS RADIO ACCESSORIES Ask your installer about the range of Ness radio devices for the optional extra convenience of wireless remote control and wireless detection Operating your Ness security system can be as convenient as opening your car door The Ness Radio Key provides the benefits of separate ON OFF and PANIC buttons in a slim waterproof remote control MADE AUSTRALIA Ness radio products require a Ness Radio Interface 100 200 to be fitted to the control panel NESS RADIO KEYPAD A unique fully portable radio ua keypad The Ness Radio Keypad v provides totally wireless Arming Disarming of the Ness 08 016 amp 024 control panels Also operates Monitor mode and Panic when used with the Ness D16 D24 panels The Ness radio Keypad is suitable for use as a portable keypad or for adding an extra keypad in areas where it is not possible to install wires NESS RADIO PIR Ness Radio PIR Passive Infrared motion detector for 1 wireless motion detection Can be used in combination with Ness hardwired detectors in areas where it is not possible to install wires Includes long life lithium battery Also available the 100 663PET radio Pet Aware model which detects humans but is immune to household pets NESS
20. evices may be required to generate an alarm or warning only when the panel is Disarmed A zone with this assignment is called a Day zone Before leaving the premises you must Arm the panel to enable it to detect intruders and generate an alarm After arming the panel will ignore detectors during the Exit Delay Time to enable you to depart without triggering an alarm NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com Arming the system may be done through the keypad or with the use of optional Radio Keys for Arming by remote control from outside the premises When you enter the premises the panel will ignore selected zones for the Entry Delay Time and will not alarm unless you don t Disarm the panel during this allowed time Disarming the system may be done by keypad or with the use of optional Radio Keys Monitor mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home If you wish to split your alarm system into two areas with access limited to each area by code numbers then Area operation is used Radio Keys can also Arm and Disarm Areas The control panel housing and the covers over external sirens are protected by tamper switches to detect someone attempting to disable the security system Activation of these switches will cause an instant tamper alarm If a detector becomes faulty you ca
21. g to guess your code by entering random numbers AREA OPERATION Area Partitioning allows the 8 zones to be split into two partitions Area1 and Area2 The panel then effectively operates as two separate systems sharing only the siren outputs and dialler USER CODE ASSIGNMENT A User Code assigned to an Area can Arm and Disarm only that Area User Codes assigned to both Areas will operate both Areas simultaneously COMMON AREA ZONES Zones assigned to both Areas are Armed only when Area1 and Area2 are both Armed This allows the Common Area zone s to be shared by both Areas For example Office A and Office B operate as separate areas but the entrance foyer used by both offices is assigned to both areas meaning it will automatically Arm when both Areas have Armed The Common Area then automatically disarms when either Area1 or Area2 Disarms OPERATION Arming and Disarming is carried out as normal from a single keypad or separate keypads installed in both areas or by Radio Key Area operation only applies to zones when they are in the Armed state This means that Day 24hr and Monitor zones are independent of the area operations Note Area partitioning is in addition to Monitor Mode Any zone may be allocated to any area NESS 08 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com LED KEYPAD The Ready light must be on Press CED
22. human intruders allowing you PET AWARE we to secure your home DETECTORS with your pets indoors CCTV The Ness range of Closed Circuit TV equipment includes Dome cameras B W or Colour cameras Miniature hidden cameras Monitors even digital video recorders and remote telephone video systems QUANTUM 15m passive infra red detector with selectable pulse count suitable for domestic and commercial installations PetAware model available QUANTUM PLUS 15m passive infra red detector with selectable pulse count temperature compensation and downward looking creep zones QUANTUM DUAL 15m combination microwave and passive infra red detector This combination of detection technologies virtually eliminates the possibility of unwanted alarms but faithfully detects humans PetAware model available QUANTUM 360 Ceiling mounted 360 passive infra red detector with selectable pulse count and sensitivity Provides 8 metre coverage mounted at standard 2 4 metre ceiling height SIRENS The range of warning devices includes horn speakers polytough siren covers internal screamers and satellite sirens with their own battery backup SWITCHES A variety of switches are available for protecting doors and windows The line up includes surface and flush mount reed switches emergency buttons roller door reed switches and the unique Nessensor vibration sensor for highly effective p
23. ic Shortcut Of ENTER must be ON P62E 4E C D E must be ON 62 4E Press and hold for 4 seconds P68E 3E amp 4E must be OFF User Code C User Code KEYPAD DURESS x x To Disarm and report a Duress Alarm add of the digits 5 6 8 or 9 before the User Code when Disarming EXCLUDING ZONES User Code OF User Code CE Zone No Enter the zone numbers Zone No E Enter the zone numbers Zone No to be Excluded Zone E o be Excluded To Exelude E To exit Exclude mode E ALARM MEMORY User Code or User Code E Press repeatedly to display the last press repeatedly to display 30 events the last 30 events To exit Memory mode E To exit Memory mode NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com
24. ing the Follow Me Telephone Number AUDIBLE MONITORING SEQUENCE When triggered by an alarm the D8 will dial the programmed telephone number s and output the audible message for 45 seconds or until it is acknowledged ACKNOWLEDGING THE ALARM The person receiving the call can then acknowledge the alarm by pressing the key on their telephone Press the st key for atleast 2 seconds during pauses in the audible message If the alarm is not acknowledged the keypad s LINE light will flash continuously until the panel is next Armed REMOTE OPERATION OPERATING THE D8 BY TELEPHONE The D8 will allow a user to call in to the panel using a standard DTMF telephone and remotely Arm or Disarm all areas and also turn on or off Aux 1 and Aux 2 To ensure security of operation a user can only carry out remote operations after entering a valid user code WHAT S NEEDED Atelephone with DTMF tones A Valid User code programmed in the D8 The D8 to be connected via Mode 3 socket to a working telephone line at the installed premises You need to know the telephone number of the line that the D8 is connected to NOTES SEQUENCE OF OPERATION 1 Phone the D8 telephone number and listen for the required number of rings ring ring ring ring and then hang up Wait 10 seconds and then call the number again within 50 seconds The D8 will answer the second call immediately sound a beep for 2 sec
25. ll radio supervision Contact ID Dialler Format Ultra Modern and Impact resistant Housing Ness Audible Dialler Format Follow Me Audible Dialler Option Separate 24 Hour Tamper input Single or Double Trigger Zones Hemote LED or LCD Keypads Max 3 Fully programmable via the system Keypad Eliminates the need for expensive programmers or Proms Inbuilt Vibration Sensor Analyser All programming data is permanently stored in a non volatile EEprom memory Windows based Up Down load Software allows remote programming and event status True Dynamic Battery Test every time the Panel is armed disarmed and every hour Area Partitionable 2 Areas Any Zone can be programmed to any area as well as common areas Comes complete with an AC plug pack and supports a 12V 7Ah battery to maintain systems security under all power supply conditions Monitor Mode Home Mode Outputs are separately fused with Automatic Reset Fuses Day Mode and Door Chime feature 30 Event Memory Supports 8 Radio Devices Radio PIRs Radio Reeds etc Supports 14 Radio Keys All inputs and outputs are heavily protected against lightning and high voltage supply transients An earth terminal is provided for extra protec tion 15 User Codes Arm only codes can be programmed Programmable Inputs to activate selectable Outputs Designed utilising the latest SMD Technology Simple to Program and Use ES NESS D8 V4 CONTROL PANEL
26. monitored by a central monitoring station 2 If Fire Alarm Report has been enabled by your installer KEYPAD FIRE ALARM OPERATION LCD KEYPAD Press 3 E sounds the siren Fire Alarm siren sound 1 If Keypad Fire Alarm has been enabled by your installer Sends a Fire Alarm report by dialler 1 If your system is monitored by a central monitoring station 2 If Fire Alarm Report has been enabled by your installer KEYPAD MEDICAL ALARM S LED KEYPAD LCD KEYPAD Press 2 Press 2 E Sends Medical Alarm report by dialler 1 If your system is monitored by a central monitoring station 2 If Medical Alarm Report has been enabled by your installer Medical Alarm does not sound sirens Sends a Medical Alarm report by dialler 1 If your system is monitored by a central monitoring station 2 If Medical Alarm Report has been enabled by your installer Medical Alarm does not sound sirens NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com OPERATION EXCLUDING ZONES LED KEYPAD ded Q Press ENTER Or User Code CA The Exclude light will turn on Enter the zone number of the zone s to be Excluded Zone Zone No The zone light of each Excluded zone will turn on Press to exit Exclude mode The Exclude light will flash continuously If a
27. n Exclude the associated zone so that it is totally ignored and cannot generate an alarm Including the zone will enable it to generate an alarm again The control panel is fitted with a rechargeable stand by battery to ensure your security system continues to operate if the mains power is interrupted This control panel automatically tests the battery every hour and whenever you Arm Disarm the panel Dynamic Battery test Whenever an alarm occurs it may be silenced with a User Code or by optional Radio Keys otherwise it will reset at the end of Alarm Reset Time All alarms are stored in memory and may be viewed at any time by entering Memory Mode KEYPAD The D8 control panel may be supplied with either the LED keypad 100 192 or the Ness LCD Keypad 100 667 The keypad provides important visual and audible indications and is the main interface for operating and programming the D8 control panel I 105mm LED KEYPAD Zones 1 2 3 4 5 6 7 8 O Reedy O Armed O Arm 2 O Memory O Mains O Exclude O Battery O Tamper O Radio O Line O Program MEMORY button PANIC buttons ARM button Cz MONITOR button EXCLUDE button PROGRAM button ENTER button Protective flap not shown 150mm 90mm LCD KEYPAD T Backlit LCD LT 2 3 45 6 4 8 icon display 9 10 11 12 13 14 15 16 v amp mM 1 READY ARMED ARM2 ALARM TAMPER RA
28. ne Detection Devices e g PIR Reed Switch may be Unsealed The mains power may be off Or the panel s backup battery may be low 0r a Radio Device battery may be low Invalid keypad entry zone was Unsealed at the end of Exit Delay time There has been an alarm A 24 hour zone has been triggered E g Siren Tamper Box Tamper Panic Button A zone s has been Excluded The 24 hour Tamper input has triggered There are alarms in memory The panel is Armed Only the Master Code can enter Program Mode REMEDY Close door or window find the cause of movement Make sure the plug pack is plugged in and the power point is turned on Call your installer Press E button and try again Disarm the panel and check all zones Reset the alarm by Disarming the panel and check the Alarm Memory Reset the alarm by Disarming the panel and call your installer Call your installer To clear the ALARM MEMORY light view the Alarm memory otherwise the light will clear next time you Arm the panel Disarm the panel before attempting to enter Program Mode Try again using the Master Code NESS D8 V4 CONTROL PANEL USER MANUAL GRE Manuals Online http www tech man com INSTALLATION RECORD INSTALLATION RECORD Installation Company D od 8 Telephone DIALLER SECURITY ALARM PANEL ZONES DEVICE 5 21 DESCRIPTION Entrance bedroomt etc NESS D8 Monitoring Company
29. onds then after a pause it will sound a lower frequency tone The D8 is now ready to receive telephone commands Press the 0 button on the telephone This tells the D8 that telephone commands will follow It will respond with either 3 beeps if all OK One long beep means try again Now enter a valid User Code that is normally used for Arming or Disarming the D8 followed by the s button The D8 will respond with 3 beeps if it recognises the code or 1 long beep to signal the code was invalid and to try again Enter the required command See Summary Of Telephone Commands Press st to finish This tells the D8 to hang up Also hang up your telephone If the D8 does not receive commands for periods longer than 10 seconds it will assume that the call is finished and it will hang up f an alarm occurs which requires the 08 to dial out while attempting remote control the D8 will treat the alarm as a priority give a constant tone as a warning and then hang up When all remote control commands are finished press st to force the D8 to hang up 22 NESS 08 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com REMOTE OPERATION EXAMPLE ARMING THE D8 BY TELEPHONE Dial the D8 telephone number Listen for one double ring then hang up Wait 10 seconds then dial the D8 telephone number again The 08 will answer immediately and gives a 2 second beep follow
30. ost recent event will be displayed Press and so on up to 30 events Press to exit Memory mode The D8 Control Panel stores a comprehensive Alarm Memory including Arming Disarming Low Battery Mains Fail and Alarm events The memory is constantly upgraded and the last 30 events are always available for viewing This Memory display can only be selected while the panel is in the Disarmed state LCD KEYPAD Press Gis Or User Code eed The MEMORY icon will turn on Press The most recent event will be displayed Press The next most recent event will be displayed Press and so on up to 30 events Press E to exit Memory mode TO CLEAR THE MEMORY LIGHT The MEMORY light flashes continuously when an alarm has occurred as a reminder to view the alarm memory The MEMORY light stops flashing after the memory is viewed as shown above The MEMORY light is automatically cleared next time the panel is Armed MEMORY MODE EVENTS INDICATED BY KEYPAD LIGHTS LIGHT ALARM EVENT Zone lights 1 8 Zone alarm ARM Panel Armed no lights Panel Disarmed TAMPER Tamper alarm Siren cover panel etc EXCLUDE Panic alarm BATTERY Low Battery MAINS Mains power failure RADIO BATTERY ZONE RADIO BATTERY ARM NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com Radio Device battery low Radio Key battery low RAD
31. our monitoring contact your installer or Ness Security Products EJ NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com AUDIBLE MONITORING FIXED TELEPHONE MOBILE TELEPHONE MONITORED PREMISES TELEPHONE LINE The Primary and Secondary telephone numbers are normally only used for central station monitoring These numbers can only be programmed in Installer Program Mode The Follow Me Telephone Number replaces the Primary AND Secondary telephone numbers NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com AUDIBLE MONITORING The D8 can also be programmed to send audible messages to any telephone or mobile phone When programmed for audible monitoring the D8 calls a pre programmed number or numbers and sounds a series of beeps over the phone These beeps can identify the zone or zones which caused the alarm and well as several other alarm types FOLLOW ME TELEPHONE NUMBER The Follow Me Telephone Number is the telephone number to which the D8 sends alarm reports when Audible Monitoring is enabled The Follow Me Telephone Number can be changed by the user in User program Mode If the Follow Me Telephone Number is programmed the Primary and Secondary telephone numbers are ignored even if programmed When Audible Monitoring is enabled See page 19 for information on programm
32. r code then you must press enter and start again Five incorrect entries will cause an alarm f Entry Beeps are programmed on ALARMS DEFINITION Alarms may be caused by Azone has been triggered while Armed A Tamper has been triggered A PANIC button has been triggered All of these may cause your sirens and strobe to operate Various visual indications relevant to the alarm will be retained in the memory If this occurs Disarming your control panel will reset the alarm The cause of the alarm can be identified by entering the Alarm Memory Mode as described on page 15 KJ NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com OPERATION MONITOR MODE LED KEYPAD dd Press _ ENTER or User Code The Monitor light will turn on Only the zones which have been programmed by your installer as Monitor zones will be Armed Monitor mode allows you to Arm selected zones while others are ignored Typically perimeter zones doors and windows can be monitored while you are at home Your installer must program which zones will be active in Monitor mode The panel must be fully Disarmed before Arming in Monitor Mode NESS D8 V4 CONTROL PANEL USER MANUAL Technical Manuals Online http www tech man com LCD KEYPAD Press E a Or User Code E p icon will turn