Home

HUE-800 manual_v1.00_8-8

image

Contents

1. H ye V7 Lt Yi Wie Fault Bottom Panel of the 8 port 10 100BaseTX Industrial Switch Wiring the Power Inputs Please follow below steps to insert the power wire 1 Insert the positive and negative wires into the V and V connector on the terminal block connector 2 Totighten the wire clamp screws for preventing the DC wires to loose NOTE The wire range of terminal block is from 12 24 AWG LED Indicators There are several diagnostic LEDs located on the Front panel of the industrial switch They provide real time information of system and optional status The following table provides description of the LED status and their meanings for the switch When the industrial switch has power input s the LED will light on No any power inputs Power on No power inputs Power on No power inputs an The port is linking with its link Green partner The port is transmitting or receivin LNK ACT port 7 amp 8 Blinks oe EE 9 packets from the TX device No device attached The port is operating in full duplex mode Collision of Packets occurs in the FDX COL port 7 amp 8 Blinks port The port in half duplex mode or no device attached The port is operating in full duplex mode Blinking Collision of Packets occurs Orange The port is in half duplex mode or Port 1 6 LED no device is attached Indicator A network device is detected Blinking The port is tr
2. industrial switch 4 Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall 5 Toremove the wall mount plate reverse steps above Converter Hardware Installation In this paragraph we will describe how to install the 8 port 10 100Base T X Industrial Switch and the installation points for the attention 100Base TX Ethernet Cats 5 UTPYSTP cable Data collect server Human Management Interface ee FEFEFE Enterprise Switch Industrial fl Industrial Industrial f Switch JE Switch Switch amp ul Bt 1 p Programmable logic controller 100Base TX Ethernet Cat3 5 UTP STP cable Distribute 1 0 control system yo Field Automatic device Field Automatic device Field Automatic device Installation Steps 1 Unpacked the Industrial switch 2 Check the DIN Rail is screwed on the Industrial switch If the DIN Rail is not screwed on the Industrial switch Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial switch then please refer to Wall Mount Plate Mounting section for wall mount plate installation 3 To hang the Industrial switch on the DIN Rail track or wall please refer 12 to the Mounting Installation section Power on the Industrial switch How to wire the power please refer to the Wiring the Power Inputs section The power LED on th
3. 8 port 10 100BaseTX Industrial Switch User Manual Rev 1 00 8 August 2006 Content MOAN 1 FU 1 Package Contents r rrnrarrnranrnrnnnnonnnrennnnennanennnnenne 1 Hardware Description arrnarrnnrnarrnnrnnnennrnnnnnnn 3 Physical Dimension vaere 3 FONG ANO EE EE EE 3 BOOM WICW undere adksa aedi 4 Wiring the Power Inputs cccscceeeseeeeeeseeeeeeeees 4 EE DANOICATO EEE EEE EE 5 PON rer E EE 7 CNS 8 Mounting Installation rrnnrrnrrnrrnernnrnnnvnnrnnnnnn 9 DIN Ral WIQUPTING Warner 9 Wall Mount Plate Mounting rrnarnnnrnnnnnnrnnnvnnrnnnr 11 Hardware Installation rrrnrrnnrnnnrvarevnnennnenen 12 Troubles Shooting rrarrnnrnnnrnnrvanrnnrnnnrnnrnnnennn 14 Technical Specification rrarrrarenerererrnnrnnerr 15 Introduction The 8 port 10 100BaseTX Industrial Switch is a cost effective solution and meets the high reliability requirements demanded by industrial applications It provides the redundant power inputs that prevent the power failure Features 8 port 10 1001 X unmanaged industrial switch Conforms to IEEE 802 3 10Base T 802 3u 100Base TX 100Base FX Store and Forward switching architecture RJ 45 port support auto MDI MDI X function 1Mbits Embedded memory IEEE 802 3x flow control support gt Flow control on full duplex gt Back pressure on half duplex Wide range redundant power design 2K MAG address table DIN rail and
4. ansmitting or receiving Green packets from the TX device No device is attached Ports RJ 45 ports Auto MDI MDIX 8x 10 100Mbps auto sensing port for 10Base T or 100Base TX devices connection The UTP ports will auto sense for 10Base T or 100Base TX connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling See figures for straight through and crossover cable schematic mE RJ 45 Pin Assignments Pin umber Aesaet ee ee NOTE and signs represent the polarity of the wires that make up each wire pair All ports on this industrial switch support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name EE Receive Data plus RD Transmit Data plus TD Receive Data minus RD Transmit Data minus TD Transmit Data plus TD Receive Data plus RD ae Transmit Data minus TD Receive Data minus RD Switch Router or PO 3 TD 3 RD 6 TD 6 RD KD TD 2 kD 2 TD Straight Through Cable Schemat
5. e Industrial switch will light up Please refer to the LED Indicators section for meaning of LED lights Prepare the twisted pair straight through Category 5 cable for Ethernet connection Insert one side of Category 5 cables into the Industrial switch Ethernet port RJ 45 port and another side of category 5 cables to the network devices Ethernet port RJ 45 port ex switch Pc or Server The UTP port RJ 45 LED on the Industrial switch will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning NOTE Be sure the connected network devices support MDI MDI X If it does not support then use the crossover category 5 cable When all connections are all set and LED lights all show in normal the installation is complete Troubles shooting m Verify that you are using the right power cord adapter DC 12 48V please don t use the power adapter with DC output bigger than 48V or it will burn this converter down m Select the proper UTP able to construct your network Please check that you are using the right cable use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1009 Category 3 4 or 5 cable for 10Mbps connections or 1000 Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet m Diagnosing LED Indicators the Switch can b
6. e easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions m IF the power indicator does not turn on when the power cord is plugged in you may have a problem with power cord Than check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance m If the Industrial switch LED indicators are normal and the connected cables are correct and the packets still cannot transmit Please check your system s Ethernet devices configuration or status Technical Specification The 8 port 10 100BaseTX Industrial Switch technical specification is following IEEE 802 3 10Base T Ethernet Standard IEEE 802 3u 100Base TX Fast Ethernet IEEE802 3x Flow Control and Back pressure Technology Store and forward switching architecture 14 880 pps for Ethernet port Transfer Rate 148 800 pps for Fast Ethernet port MAC address 2K MAC address table Memory Buffer 1 Mbits m Port 7 amp 8 Link Activity Green Full duplex Collision Orange E Port 1 6 Two LED indicator Green Orange m Per unit Power Green Power 1 Green Power 2 Green 10Base T 2 pair UTP STP Cat 3 4 5 cable EIA TIA 568 100 ohm 100m Network Cable 100Base TX 2 pair UTP STP Cat 5 cable EIA TIA 568 100 ohm 100m Back plane 1 6 Gbps 12 48 VDG Redundant powe
7. ic Switch Switch 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD Cross Over Cable Schematic Cabling Use the four twisted pair Category 5 cabling for RJ 45 port connection The cable between the converter and the link partner switch hub workstation etc must be less than 100 meters 328 ft long Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the below steps to hang the industrial switch Rear Panel of the switch 1 Use the screws to screw on the DIN Rail on the industrial switch 2 To remove the DIN Rail reverse the step 1 1 First insert the top of DIN Rail into the track ME l y 2 Then lightly push the button of DIN Rail into the track 3 mil s HELE 3 Check the DIN Rail is tightly on the track 4 To remove the industrial switch from the track reverse steps above Wall Mount Plate Mounting Follow the below steps to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rear panel of the industrial switch 3 Use the screws to screw the wall mount plate on the
8. r with polarity Power Supply reverse protect function Power consumption 4 6 Watts Packet throughput 1 19Mpps 64bytes 8TX ability Provides DIN rail kit and wall mount ear for 3 way install Operation OC to60C 82F to 140 F Temperature Operation or 5 to 95 Non condensing Humidity Storage 40 to 85 Temperature Ambient Relative 5 to 90 non condensing Humidity IP 30 54 mm W x 135 mm H x 105mm D FCC Class A CE EN6100 4 2 CE EN6100 4 3 CE EN 6100 4 4 CE EN6100 4 5 CE EN6100 4 6 Safety UL cUL CE EN60950 IEC60068 2 32 Free fall IEC60068 2 27 Stability testing Shock IEC60068 2 6 Vibration
9. wall mount design Easy configuration design Power polarity reverse protect Package Contents Please refer to the package content list below to verify them against the checklist m 8 port 10 100BaseTX Industrial Switch m One DIN Rail Screwed on the switch 1 m One wall mount plate and six screws m User manual 5 6 q 9 4 f O 6 O qQ Wall Mount Plate Screws DIN Rail Compare the contents of your industrial switch with the standard checklist above If any item is damaged or missing please contact your local dealer for service Hardware Description In this paragraph we will introduce the Industrial switch s hardware spec port cabling information and wiring installation Physical Dimension The 8 port 10 100BaseTX Industrial Switch dimension W x H x D is 54mm x 135mm x 105mm Front Panel The Front Panel of the 8 port 10 100BaseTX Industrial Switch is showed as following figure LED Indicator FOX LHK COL a aa ACT y E P PFG P3 P4 P1 P Front Panel of the 8 port 10 100BaseTX Industrial Switch UTP Port 3 Bottom View The bottom panel of the 8 port 10 100BaseTX Industrial Switch consists one terminal block connector within two DC power inputs and one DC IN power jack for extra AC DC power adapter m E OO99000000000000 68 Ogqgoo0oo0o0oo0oo0o00000 0 GUU OO OG C UG OU OD OU DE IN PWR2 1A 24V PWRI es er Power Input DC 24v 12V 48V