Home

LP Morgan Dipper User Manual - Herma Projection Screen

image

Contents

1. Front of projector LP Morgan Installation Instructions 17 LP Morgan Dipper Manual Projector installation First ensure that the Dipper is operating correctly and that the projector cables are properly secured Open the Dipper and insert the triangular projector plate into the slot in the rear of the Dipper Attach it to the front using the supplied M6 bolts and springs washers These bolts will also give you Yaw and Tilt adjustment to align your image on the screen while the centre M8 bolt provides Pan adjustment The springs will ensure that the projector is held still during motion Do not install the projector plate without springs Longer cap screws and extra springs are supplied if you need extra downwards tilt M6 x 75 Cap Screws M6 x 90 Cap Screws Tilt Yaw 18 LP Morgan Installation Instructions LP Morgan Dipper Manual Accessories The following Dipper accessories are also avilable from LP Morgan Contact your local retailer for pricing information Triggering From Projector HER20HD12V 12 volt trigger unit for projectors with a 12 volt trigger output e Often used also with LPM43SCR12V Screen 12V Trigger HER20HD12V and LPM48HDSCRTRIG Trigger Unit for Projectors without a 12 Volt Trigger e Uses current sensing to detect when the projector is on Triggers a screen as well e Includes an IR repeater kit Infra Red Remote Control HER
2. Wall switch 24V Power supply The Dipper is supplied with a unique control unit that can be adapted to just about any installation requirement It operates via dry contacts but can be easily upgraded to a 12V trigger infra red remote control or even RS232 A maintained single pull single throw switch a normal light switch comes supplied as standard or alternatively you can use a single relay Open circuit is up close circuit is down You do not need to be a qualified electrician to wire the Dipper as alll circuiting is 24V however Herma will not accept responsibility for damage incurred by faulty or incorrect wiring The power supply and motor are pre wired so all you need to do is attach the relay or motor cable and switch as shown in the following diagram The switch needs to be wired into the Switch Up and Common terminals 14 LP Morgan Installation Instructions LP Morgan Dipper Manual Wiring diagram Do not under any circumstances connect 240 VAC to any of these terminals 24V Positive 24V Negative Motor blue Motor brown Switch down not used Switch up in standard configuration Cable management Every projector has slightly different cable exit positions and because of this the Dipper does not have a dedicated cable exit hole Instead we recommend you drill a hole in an appropriate place on the top timber panel Make sure to leave enough slack in the cable to accou
3. the Dipper itself through the four mounting holes using the threaded rods Threaded rod and nuts You can use the nuts to adjust the height of the Dipper once installed so you can get it exactly flush with the ceiling LP Morgan Installation Instructions 11 LP Morgan Dipper Manual Ceiling fastening trussed ceiling For some ceilings you will need to construct a support structure for the Dipper to rest in this can be as simple as two appropriately spaced bearers at the right height See the previous pages for the relevant dimensions Screwed straight into bearers Allow yourself some way to easily adjust the height of the Dipper once installed so you can get it exactly flush with the ceiling 12 LP Morgan Installation Instructions LP Morgan Dipper Manual Face plate installation Once the Dipper frame is install you should attached the face panel It is recommended that you paint the face panel to match the room before installing it M4 Washer 1 Insert 4 x countersunk bolts washers M4 CS Bol and springs as shown through face NN z panel from the underside Stick Pad 2 Adjust the level so that it is exactly flush with the underside of the ceiling 3 Once full adjusted cover holes with stick pads for more information refer to Page 9 LP Morgan Installation Instructions 13 LP Morgan Dipper Manual Electrical installation Protective enclosure Control unit
4. 20HDIRKIT Infra Red remote control and receiver RS232 Integration LPM43MULTI RS232 Interface for both Projector Mount and Screen Controls LP Morgan Installation Instructions 19 LP Morgan Dipper Manual Maintenance and troubleshooting The unit has stopped working and won t go up or down Check that all the terminations are secure that the power supply is plugged in and that the cables are free from damage A light on the power supply indicates power if it is off then the power supply may be damaged Open the black plastic enclosure to expose the control board Switch the power off and on You will see a LED flash on the circuit board which indicates power and that the circuit board is operating correctly Close the Switch Up and Common terminals on the control board refer to page 15 for a wiring diagram If the unit does not move but you hear a clicking sound then the motor may be damaged Contact Herma for advice If you have been repeatedly operating the Dipper the motor may have reached a thermal cutout and won t operate Wait five minutes for it cool and try again If you have integrated the Dipper into a control system eg projector triggering IR repeating Crestron AMX etc then the problem is most likely with the control system Check that the right signal is getting to the Dipper Use the wall switch close the Switch Up and Common te
5. LP Morgan Dipper User Manual lomorgan www lpmorgan com au LP Morgan Dipper Manual Table of contents To the owner 3 Face plate installation Unpacking 4 Electrical installation Dipper views 5 6 Wiring diagram Part names and dimensions 7 Cable management Mechanical installation 8 Projector installation Ceiling opening g Accessories Ceiling space 10 Maintenance and Troubleshooting Ceiling fastening 1 suspended ceiling Warranty Information Ceiling fastening trussed ceiling lg ATTENTION Please read all of these instructions before you operate your Dipper for the first time Save these instructions for further reference A TOEN A Never operate the Dipper while the projector is still powered Information in this document is subject to change without notice Herma Technologies All rights reserved Trademarks used in this text Herma the Herma Logo Galleria LP Morgan and LP Morgan logo are registered trademarks of Herma Technologies Other trademarks and trade names used in this document remain the property of the relevant owners October 2011 Version 2 2 This document is protected against unauthorised copying electronic or otherwise 13 14 15 15 16 18 19 20 21 2 LP Morgan Installation Instructions LP Morgan Dipper Manual To the owner Congratulations on purchasing an Australian made LP Morgan Dipper motorised projector mount This innovative projecto
6. The Dipper comes with a 12mm undercoated MDF ceiling face plate and an aluminium ceiling trim It is recommended that you paint this panel before installing the Dipper in the ceiling In the case of a non plasterboard ceiling you may choose to fabricate your own ceiling panel eg from the same timber material as the ceiling itself to match It is recommended that you leave a 2mm gap around all edges of the Dipper s ceiling face plate Supplied is a plastic trim that you may use to finish off the edge of the hole The cutout dimensions given below assume that you will use this ceiling trim Cutout required Cutout required Face Panel f i z Dipper Size Lx W without ceiling trim with ceiling trim Lx W Lx W Medium 400 x 400 405 x 405 430 x 430 Large 500 x 500 505 x 505 530 x 530 All measurements are in milimetres LP Morgan Installation Instructions 9 LP Morgan Dipper Manual Ceiling space The following diagrams show the position of the ceiling cutout in relation to the Dipper frame and the space required above the ceiling Length Width Height Front Gap Rear Gap Dipper Size EP O w B L1 L2 Medium 650 405 355 32 212 Large 830 505 430 27 297 All measurements are in millimetres 10 LP Morgan Installation Instructions LP Morgan Dipper Manual Ceiling fastening suspended ceiling For suspended ceilings you can suspend
7. including Supply mounting bolts and spacers Wall Switch and Architrave Spring Bolts Washers Mount Cardboard Dust cover When unpacking the Dipper please hancle all parts with care Do not destroy the folded inner box when unpacking as it is the dust cover for this unit 4 LP Morgan Installation Instructions LP Morgan Dipper Manual Front view closed position ca en 7 Dipper Overall Face Panel v a Width Width E D1 D3 Medium 405mm 400mm Large 505mm 500mm Front 3D view Main Frame Skyhook Plate Mounting Tabs Face Panel LP Morgan Installation Instructions 5 LP Morgan Dipper Manual Top view closed position Cc D o D D2D1 7 an ep K ly o z y C1 C3 gt lt C2 Dipper Front Overall Rear Overall Mounting nia mounting Length mounting Width hole Width ze hole C1 C2 hole C3 D1 D2 Medium 15 6500 50 405 380 Large 15 830 40 505 480 All measurements are in millimetres 6 LP Morgan Installation Instructions LP Morgan Dipper Manual Part names and dimensions When installing the Dipper be sure to allow access for future maintenance requirements of the
8. lacement Equipment must be returned to Herma in suitable packing to prevent damage in transit Herma will not accept any responsibility for damage to the equipment caused by inadequate or unsuitable packing or for any damage howsoever caused whilst the goods are in transit Herma Technologies shall not be liable for any injury loss or damage direct or consequential arising out of the use of misuse of or inability to use the equipment This Warranty does not cover any product which has been subjected to misuse abuse neglect accidental or intentional damage improper voltage or any alteration which affects the reliability or performance of the equipment not attributable to faulty manufacture parts or labour and without limiting the generality of the foregoing This Warranty does not cover any product where usage adaptation or installation are not in accordance with our written installation and operating instructions Warranty Period Two years from date of purchase LP Morgan Installation Instructions 21 For more information on our range of products please visit www pmorgan com au or contact your local LP Morgan Retailer Factory 4a 6 Albert Street Preston Vic 3072 Phone 61 3 9480 6233 Fax 61 3 9480 6533 Email info herma com au www lpmorgan com au lp morgan October 2011 Version 3 1
9. nt for the motion of the Dipper during operation LP Morgan Installation Instructions 15 LP Morgan Dipper Manual Projector installation The Dipper uses the LP Morgan Skyhook projector mount system The parts kit contains e 4x long Skyhook arms e 4x M4 4x M5 amp 4 x M6 mounting bolts e 4 X springs Determine which size mounting bolts suit your projector and set others aside They are no longer required If your projector has only 3 mounting holes remove one of the adjustable arms Undo the M8 Nyloc nut remove an arm and replace the nut Before connecting the L Skyhook spread out the arms so each end is over one of C L 7 the mounting holes If you C feel it necessary this is an appropriate time to remove 12 one or two of the short arms and replace with the supplied optional longer arms 0 0 Front of projector 16 LP Morgan Installation Instructions LP Morgan Dipper Manual Connect the Skyhook to projector Fit the springs between the arms and the projector and tighten the mounting bolts so that the projector is parallel to the triangular plate Move the position of the triangular plate over the centre of the projector adjusting the unit so that the edge with the two holes aligns with the front of the projector Tighten the mounting bolts The projector and skyhook system is ready to be inserted into the Dipper
10. r mounting system is a novel and secure way to mount your projector out of sight when not in use giving you maximum enjoyment and a truly cinematic experience Please take a moment to review this manual as it will ensure you many years of trouble free service from your new Dipper On Safety Check that the operating voltage of your unit is identical with the voltage of your local power supply If voltage adaptation is required consult with qualified an electrician Should liquid or solid objects fall into the unit unplug and have it checked by qualified personnel before operating it further To disconnect the cord pull it out by the plug Never pull the cord itself The power supply should be near the unit and easily accessible The unit is not disconnected from the AC power source as long as it is connected to the wall outlet even if the unit has been turned off Do not place your hand or other objects near the trapdoor during operation The Skyhook projector mount must be used for installation with the Dipper On Cleaning To keep the unit looking new and clean a dust cover is supplied If cleaning is necessary use a soft cloth and mild detergent solution Never use strong solvents such as thinners benzene or abrasive cleaners LP Morgan Installation Instructions 3 LP Morgan Dipper Manual Unpacking the Dipper Control Unit Protective Enclosure LP Morgan Skyhook Projector 24V Power Mount System
11. rminals to test the unit I can t get enough downwards tilt on my projector We have supplied long 75mm and extra long 95mm M6 caps screw bolts if you need to angle the projector further down Use the extra springs also supplied to keep the Skyhook plate tightly secured 20 LP Morgan Installation Instructions LP Morgan Dipper Manual Warranty Information Keep your original receipt for warranty Please fill out the online warranty form in order to qualify for the manufacturer s warranty http www pmorgan com au owners html The warranty covers defects in workmanship and materials provided this product has been installed in a normal environment and maintained according to the written instructions Herma warrants the product against loss of usefulness discolouration or deterioration of optical quality within the warranty period as a result of manufacturing or material defects This warranty applies only within Australia Please return your goods to the place of purchase for all warranty claims Conditions Any equipment replaced pursuant to the terms of this warranty shall be retained by Herma All costs related to de installation and re installation of the product covered by this warranty are not the responsibility of Herma Technologies Herma will not be responsible for any consequential damages during or following installation procedures Herma is not responsible for any freight costs relating to repair or rep
12. unit Wherever possible allow access to the ceiling cavity other than through the Dipper s hole so that you can access the projector should the power supply fail Side view Biber Front Rear Overall Face Plate Face Plate Face Plate ah Mount Mount Height to Front Length to back Tabs A1 Tabs A2 A3 B1 B2 B3 Medium 125 205 355 35 400 215 Large 125 175 430 30 500 300 All measurements are in milimetres LP Morgan Installation Instructions 7 LP Morgan Dipper Manual Mechanical installation The first crucial step like any projector installation is to determine where to put the Dipper in the ceiling The Dipper should be installed so that the projector lens is centred horizontally to the screen The distance from the screen depends on the projector s throw distance Calculate the maximum and minimum throw distances for the projector and place the Dipper somewhere in between It is better for the projector to be closer to the screen but don t place it at the extreme end of your calculation Allow some room to adjust the zoom in either direction Screen Projector center Screen center Lens center Throw Distance Note When aligning the Dipper make sure that the projector lens is centred on the screen which is not necessarily the projector centre 8 LP Morgan Installation Instructions LP Morgan Dipper Manual Ceiling opening

Download Pdf Manuals

image

Related Search

Related Contents

  Nespresso  Panasonic TY-EW3D10 stereoscopic 3D glasses    LITMA6P8 ARC 120A Manual (REV  取扱説明書(PDF形式)  Foxit Reader User Manual  Clic & Surf - Documentation d`installation et de configuration  Sunrise Medical Guardian Easytrack System 900-0880 User's Manual  Axis Communications 241S Network Card User Manual  