1. the remote control outputs will turn the Maximizer on Selecting both switches at the same time is not harmful If both switches are selected the state is ALWAYS OFF If neither are selected the state is ALWAYS ON 13 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 7 1 7 2 OPERATING GUIDELINES Ensure that the Maximizer is switched OFF before making any electrical connections or closing any Input and Output Circuit Breakers CONFIGURING THE UNIT The output voltage is configured using the 3 numerical switches as outlined in Section 5 4 Set the type of battery being used flooded lead acid sealed lead acid and the type of solar panel array in use using the piano dipswitch USING THE ONBOARD LCD METER MODULE The onboard LCD Meter Module can be used for operational onsite diagnosis of the Maximizer performance The 4 position slide switch to the right of the meter module switches between the available measurements The 2 position toggle switch to the left of the meter changes the output range of the meter Input Volts Displays the input voltage being fed into the the Maximizer To read PV Open Circuit Volts turn the Maximizer OFF To read Vmp Max Power Volts or TURBINE SET POINT VOLTS turn the unit ON but without the BATTERY 10096 LED being lit up i e with the Maximizer not regulating Output Amps
2. 03 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd MOUNTING LOCATION If possible the Maximizer should be mounted vertically on a wall or similar with the meter at the top to maximize convection cooling If the Maximizer is to be mounted in a cabinet ensure that the cabinet is large and adequately ventilated Do not mount the unit anywhere that airflow is restricted Never mount the unit in a sealed enclosure it will overheat Power transfer efficiency through the Maximizer will be better the cooler the unit is kept Do not mount the unit where rain or direct sunlight can reach the unit or where moisture condensation can affect the unit The cables should always route down out of the Maximizer so that moisture condensation on the cables drips away from the electronics The Maximizer should be mounted out of reach of children ENCLOSURE When supplied in an optional high quality IP66 enclosure the Coolmax Maximizer ships with additional mounting brackets with screws for fitting directly to the bottom of the enclosure using pre threaded holes The mounting brackets are simple to install and the bracket can be bolted onto the mounting surface in a variety of configurations Note that the screw should be tightened firmly to avoid having the bracket rotate during installation The enclosure must be provided with protection from rain and direct sunlight Figure 5 2 The mounting bracket fastened t
3. Displays the total MPPT output current Changing the range setting while in this mode has no effect Battery Volts Displays the output voltage battery voltage or motor voltage depending on the MPPT s application Batt Amps Displays the battery current positive current means the battery is charging and negative current means the battery is discharging Changing the range setting while in this mode has no effect Unless the DC Load Option or Turbine Load Dump Option is enabled in your particular MPPT and a load connected to terminals 5 amp 6 this setting will always read the same as the Output Amps setting PV ARRAY CONFIGURATION NOTES OPTIMAL PV ARRAY CONFIGURATION A Maximizer runs at peak efficiency when connected to a PV panel with the minimum recommended open circuit voltage specified in its datasheet The losses in the Maximizer rise a little the more the Maximizer has to step down from the PV Max Power Voltage to the Battery Bank Voltage The input open circuit voltage Voc must be above a certain minimum for the Maximizer to run Note The minimum input voltage of the Maximizer changes depending on the nominal voltage of the battery pack in use The rule of thumb is Voc gt 1 65 x Vnom Check the datasheet for a graph to show the minimum input voltage depending on battery pack voltage 14 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australi
4. IN or OUT of circuit or to control an external load dump relay and alternative load dump resistor They no longer indicate a LOW BATTERY State on Micro Turbine Maximizers Setting the Turbine Operating Set Point Voltage Switch the Maximizer ON at both ON switches and select the LCD Multi Meter to read BATTERY AMPS For Wind Turbine MaximizerS using the AERL 3 PHASE TURBINE RECTIFIER BOARD fitted with the Turbine Lock Down Switch unlock the Wind Turbine by opening this switch if not already open For u Hydro units turn the water feed fully ON to the Turbine Trim pot T is factory set during testing for a Maximizer Input Volatge of 100V as a typical Turbine starting set point Slowly adjust clockwise to raise anti clockwise to lower the 20 turn SET TURBINE TRIMPOT T located just below the BATTERY LOW 10096 LEDS until the maximum BATTERY AMPS value is reading on the LCD meter The Turbine is now running at it s 10096 Maximum Output Power for the given water flow or wind speed This T Voltage Setting can be re optimised or checked at any time to yield maximum charging current but is best left set for typical seasonal location condition TROUBLESHOOTING LOW BATTERY LIGHT OFTEN COMES ON This could indicate that the PV system is underpowered never reaching a full 10896 equalise value The battery life will be severely compromised in this situation The more often the LED comes on the more power should be added t
5. USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd AERL CoolMax Maximizer User s Manual 1 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd Bb UU N HM 5 2 5 3 5 4 5 5 5 5 1 5 5 2 WNE TABLE OF CONTENTS OVer Vi Wesconcnnncnnconcnnncnnrnncnnnrnnrnnnnn a S aa a Ma E a a a a b a i a a a a a a a a a a a m a E aa 3 Maximizer LayQUt oococccncconconccnccnncancnncnnnrnnrnncnnnrnnrnncnnnrnnennrancannrnnnrnnnnrnnneranananass 4 Safety Precautions ccccccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeaeeasuaeeeaeeaeeaneeeageeeaaeeeeeeueaeee 6 Circuit BreakerS ooocmccooconoconconnnancnnrnncnanannrnncanonnnennrnnoranrnnennnrnnrnnenncanaranrnnannnananas 6 installati n so e a a a a a aea a aaa Ea a an a a aaa ai 8 MOUNTING iii cou n EKTA a A dane dad 8 cladis PE 8 COMME CU ONS e e DE 8 Setting the Nominal Battery Voltage Using Numerical Dials sssss 9 Advanced Float Voltage Setup sssssssssssssse mme rennen rens 10 Setting Nominal Battery Voltage Using Numerical Dials 10 Adjusting the Float Trimpot 2 isset sa eee enema aa aaia de Vae dave ia kun 11 Battery Charging Setup medad a ede du de ER duos da cd dla 11 Temperature Compensation ssssssssssseseee nemen nenne nnnm
6. V 0 6 0 84V 0 7 2 10 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 6 4 6 4 1 ADVANCED FLOAT VOLTAGE SETUP This section caters to users wanting more control over the output voltage of the Maximizer The float battery voltage is set using the numerical switches and the float trimpot positions 5 amp 6 on the Maximizer diagram in Section 2 In typical applications the numerical switches set the nominal pack voltage while the float trimpot adjusts the percentage above nominal that the pack will actually float when fully charged Example A 12V nominal flooded lead acid battery is fully charged at 2 35 2 x 12 14 1V The numerical switches would set the 12V while the float trimpot controls the 2 35 2 fully charged percentage Setting Nominal Battery Voltage Using Numerical Dials HV users Offset 24V Take the nominal voltage of your pack and subtract 24V Dial this number into the numerical dials Example You have 12 batteries in series all of which are 12V batteries giving you a nominal battery pack voltage of 144V Now subtract the offset 144 24 120 So dial 120 into the numerical switches The switches should read MV users Offset 12V Take the nominal voltage of your pack and subtract 12V Dial this number into the numerical dials Exampl
7. XIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 3 SAFETY PRECAUTIONS WARNING THE DC VOLTAGE LEVELS AT WHICH THE MAXIMIZER CAN OPERATE CAN BE POTENTIALLY LETHAL IF HANDLED WITHOUT ADEQUATE CAUTION INSTALLATION MUST BE CARRIED OUT ONLY BY A QUALIFIED ELECTRICIAN AND ALL APPLICABLE SAFETY CODES ADHERED TO DO NOT EXCEED THE CURRENT AND VOLTAGE RATINGS LISTED IN THE DATASHEET TO DO SO IMMEDIATELY VOIDS THE WARRANTY In particular the PV Input Open Circuit Voltage and Power rating must not be exceeded Note The power rating of the Maximizer varies depending on Vnom nominal battery voltage and Vmp peak power voltage of solar panels available from panel datasheet Check the charts in the datasheet to find an approximate power rating at your desired operating point Not being aware of the power rating at your operating point can lead to premature failure Always ensure that the Maximizer On Off switch is set to off and the Maximizer Off switch on the Piano switch is depressed before making or breaking any connections Never touch the Maximizer while the input OR output breakers are closed This includes when the Maximizer is switched off on the PCB Switching off the Maximizer does not isolate the Maximizer and any part of the circuitry may have lethal voltages present Always measure the PV Open Circuit Voltage and Polarity and Battery Polarity befo
8. an Energy 24 May 2010 Research Laboratories Pty Ltd 8 2 8 3 PV INPUT BLOCKING DIODE A PV Input blocking diode should not be used as long as the open circuit voltage of the PV array is within the range specified by the datasheet for the appropriate Maximizer model and battery voltage The idea of the blocking diode is to prevent night time reverse leakage from the battery into the PV array However the diode introduces power wastage during operation which outweighs the leakage resulting in a net power loss PV MODULE POWER RATING AND MOUNTING CONSIDERATIONS The nominal power output rating of a particular PV Module is specified bt the PV Module Manufacturer at One Sun 1000W sq m of sunlight radiation and 25 degees Celcius PV Module Maximum Power Voltage and consequently maximum power falls off by 496 per every 10 degrees celcius that the PV panel rises above this 25C specification so typical panel temperatures on a hot summers day of 65C will result in a panel power derating of 1696 of the manufacturers rating It is best to mount the PV Array in a way that the hot air behind the panels can easily escape via the natural breezes or convection So don t mount the PV Array flat against the roof surface but ensure there is at least 400mm spacing below the panels Small gaps 20 30mm left between adjacent panels are also a good idea to let out the hot air from the sides NOTE Around 80 of the sun light energy falling on th
9. e You have 4 12V batteries in series giving you a nominal battery pack voltage of 48V 48 12 36 So dial 36 into the numerical switches The switches should read 11 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 6 4 2 Adjusting the Float Trimpot Maximizers have the default 10096 battery float voltage set to 2 35V 2V before shipping This value can be adjusted using the trimpot labelled Battery 10096 Float near the piano dipswitch NOTE This float voltage should not be adjusted without good reason The voltage can only be adjusted when the Battery 100 LED is ON Adjustment Procedure 1 Set the switch next to the built in LCD meter display to battery volts 2 Adjust the battery float trimpot clockwise higher 3 The voltage will move very slowly so the adjustment should be made patiently over several minutes As a guideline for adjustment the battery float voltage changes by about 196 of nominal voltage for one complete turn on the trimpot So if the nominal voltage is 48V one turn of the trimpot will adjust the float voltage by roughly 0 48V 6 5 BATTERY CHARGING SETUP The batteries are charged using a 108 of Final 10096 Float Voltage Automatic Equalise Voltage Anti Sulphation charging profile The default setting for Maximizers is for 2 35V 2V flooded lead acid batteries For sealed
10. e Product is not covered for damage occurring due to failure on the part of the customer to operate the product in accordance with the technical specifications as listed in the Product Datasheet The Product is not covered for damage occurring due to lightning The Product is not covered for situations where it is used in a manner not specifically outlined in the Product Manual If any provision in this document is invalid or unenforceable this document will remain otherwise in full force apart from such provision which will be deemed deleted 20 of 20
11. e solar cells is converted directly into heat not electricity and heat is the power output enemy of PV modules 15 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 9 2 9 2 1 SPECIAL APPLICATION GUIDELINES WATER PUMPING APPLICATIONS Note All Battery models can be used for water pumping applications Select the pump motor drive ratio such that the output motor current is minimised for maximum pumping system performance Never exceed the Maximizer Output Current Rating for pumping nor the DC Motor Name plate Current Rating Always fit a motor circuit breaker with a trip current no greater than the Maximizer OUTPUT AND OR motor current ratings DO NOT use LOW VOLTAGE DC MOTORS if a higher voltage PV Array configuration will allow the use of a higher voltage lower current motor types For example don t use a 24V motor with 12 PV modules configured 3 in series 4 in parallel when a 60V or 90V motor could be used with a more efficient 6 in series 2 in parallel PV module configuration Ideally the Motor PUMP Pulley Drive Ratio is selected usually in the field at Mid Day Peak PV Output so that the DC Motor is operating at 110 120 of it s name plate voltage rating This ideal drive ratio results in maximum overall system operating efficiency and easy early morning starting of the pump motor Use the buil
12. he Product will conform to the technical specifications contained in the Product Datasheet at the time of dispatch of the Products to the Customer If the technical specifications as contained in the Product Datasheet are not met AERL will repair replace the Product or refund the amount paid by the Customer in relation to the Product at the Customers option AERL is under no obligation to provide assistance or advice to the Customer in relation to the technical specifications The Products must be installed in strict accordance with the Installation Recommendations listed in this Manual In no event will AERL be liable for a any loss or damage which the Customer suffers arising from or caused or contributed to by the Customer s negligence or the negligence of the Customer s agents or servants and b special indirect or consequential loss or damage as a result of a breach by the Customer of these Standard Terms including without limitation loss of profits or revenue personal injury death property damage and the costs of any substitute Products which the Customer obtains The Product is not covered for damage occurring due to water including but not limited to condensation moisture damage and other forms of precipitation The Product is not covered for damage occurring due to the Product being incorrectly installed or installed in a manner not in accordance with the Installation Recommendations listed in the Product Manual Th
13. hne eren nnne nnn 11 Low Battery Detection and Relay Alarm ssssssseememmee 12 Remote Control aiii iaa ia 12 Operating GuidelineS ooococconcnnocnnconcnnncnncancnnnnnnenncancrnnenncannrnnrnnennnrannnnnnnranannas 13 Configuring the UnlEiiaiaica iaa e 13 Using the Onboard LCD Meter Module sssssemmm HH 13 PV ARRAY CONFIGURATION NOTES sssseersssssssnnn nnnm nnne n nnn 13 Optimal PV Array Configuration sssssssssssseseeeneene mene mener nennen 13 PV Input Blocking Diode ree e cod ET REN RENE QR Ds 14 PV Module Power Rating and Mounting Considerations sseeeseess 14 Special Application Guidelines eeeseeeeeeeeesesse nennen nnne nnne nnne 14 Water Pumping Applications sssssssm Hem nennen 14 Micro Turbine Maximizers ssssssessesen mene nennen nnne rhe Ennn 15 Selecting the Load Dump Regulation Power Resistor oocccooccccncccnnccncnconnconcnnncnncns 15 Low Battery Circuitry on u Turbine Units ssssssssee mee 16 Setting the Turbine Operating Set Point Voltage sssssse 16 TroubleshootinQ omcconccnocancnncnnccnnranenncnnoranrnncnnnrnnrnnennnrnncrnnnrrnanrrnnnnrnnananancanans 17 Low Battery Light Often Comes On ssssssssseee mener nennen 17 Unit Does Not Charge the Battery sssssssssssssseeeme eene nnne 17 Battery Bank Using Excessive Water Electrolyte ooo
14. lead acid batteries also depress the appropriate switch on the piano dipswitch to set the float level to 2 3V 2V lead acid cell Press down the 3 Piano Dip Switch marked THIN FILM SILICONE if the PV Panels being used are of the Amorphous Thin Film type Press down the Fourth Piano Dip Switch marked SUNPOWER SILICONE if the PV Panels being used are the high performance SUNPOWER BRAND This setting is also suitable for GaAs Panels IMPORTANT To avoid overloading the Maximizer pay attention to the warnings given in Section 3 As mentioned in Section 3 it is important to avoid connecting the Maximizer to a PV Array if its power rating exceeds quoted power rating of the Maximizer for that given battery bank voltage To do so will overload the current handling capabilities of the product most likely cause damage to the board and void the warranty 6 6 TEMPERATURE COMPENSATION If precise battery case temperature compensation is required unscrew the Thermistor from 13 amp 14 and solder it to a suitable light 2 core cable and adhere the thermistor to the battery case with neutral cure silicone rubber adhesive Connect the other ends of the two core cable back into the thermistor terminal block 13 amp 14 12 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 6 7 6 8 If the Temperature Compensation Feature i
15. meter that the input voltage is sufficient to power the Maximizer If the input voltage is below the minimum input voltage of the Maximizer the unit will not power up Note The minimum input voltage of the Maximizer changes depending on the nominal voltage of the battery pack in use The rule of thumb is Voc gt 1 65 x Vnom Check the datasheet for a graph to show the minimum input voltage depending on battery pack voltage Email techsupport aerl com au with the details of your set up problem description and Maximizer model BATTERY BANK USING EXCESSIVE WATER ELECTROLYTE The battery bank is lightly loaded compared to the input PV power and rarely comes off FLOAT voltage Solution Press the 5th Piano Dipswitch marked Sealed Batts to drop the FLOAT voltage by 2 596 BLOWN FUSE The fuse must be replaced with a 500VAC 30A 3AB size fuse These are available directly from Digikey www digikey com order code F3260 ND Alternative contact AERL to have a replacement sent out 19 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 11 1 10 WARRANTY INFORMATION AERL warrants that the Product will be free from manufacturing defects for a period of 24 months from the date of dispatch of the products by AERL to the customer The Products technical specifications are contained within the Product Datasheet T
16. ndicated on the board Reversing polarity of input or output will cause damage to the Maximizer Install circuit breakers as described in Section 4 Check the polarity of the input and output with a multimeter before switching on the Maximizer Do not touch the Maximizer PCB when live wires are connected to the input or output terminals even if the Maximizer is switched OFF lethal voltages are still present in the circuitry on the PCB 9 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 6 3 SETTING THE NOMINAL BATTERY VOLTAGE USING NUMERICAL DIALS The three numerical dials are used to set the nominal battery voltage Located at position 6 on the Maximizer diagram in Section 2 Refer to the quick reference tables below to get the appropriate setting for your battery pack Users wanting to make fine adjustments to their battery float voltage should refer to Section 5 5 Quick Reference Guide for Setting Float Voltages HV Units Nominal HV Units Voltage Numerical Dial Setting 2 4 48V 72V 96V 108 120V 144V 168V e e oljoljojlolo AIN OJOJ NI A 25 ojlo nsN co Quick Reference Guide for Setting Nominal Voltages MV Units Nominal MV Units Voltage Numerical Dial Setting 12V 0 0 0 24V 0 1 2 36V 0 2 4 48V 0 3 6 60V 0 4 8 72
17. o the PV array Solution Add more PV modules to the array to increase the power output If the array is sufficiently powerful but the LED is still very often on check that the Maximizer is set up for the correct voltage of the battery pack See section 5 5 for adjusting the battery float voltage Also check that the Maximizer is charging the battery by checking the output current on the LCD meter and if the Maximizer is not functioning continue to 10 2 18 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 10 2 UNIT DOES NOT CHARGE THE BATTERY 10 3 10 4 If Temperature Compensation is not being used default setup ensure that the switch marked Temp Comp OFF switch number 9 is pressed down Not doing so may cause the unit to behave strangely If this is not the cause of the problem check the following All connections to the Maximizer are secure and screw terminals are done up tight Check the integrity of the blue circular MOVs These are surge protectors and will fail destructively in the event of circuit overload This could indicate a fault with the unit and it should be returned for repair Check the integrity of the large crowbar diodes located below the main inductor winding These fail destructively if a reverse polarity is applied The unit will need to be returned for repair Check with a multi
18. o the bottom of the IP66 enclosure 8 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 5 3 BARE PCB Mounting the bare PCB version of the Coolmax Maximizer should be performed using the supplied M5 bolts and spacers If possible the Maximizer should be bolted onto a flat mounting plate which can then in turn be mounted in the desired location Always keep the minimum space behind the board as set by the spacers to avoid short circuits caused by materials touching the back of the PCB 6 INSTALLATION 6 1 EARTHING AERL recommends that the Maximizer be utilized in a floating system no earthing whenever possible For very exposed systems it is recommended that a lightning conductor be provided nearby to prevent damage to PV equipment batteries and the Maximizer For systems using Sunpower PV arrays it is necessary to provide a positive earth for the array This can be implemented by connecting the Earth Stake bottom left corner of the Maximizer directly to earth If a negative earth is used for the batteries or DC system do not earth the array If a negative earth is used for either the batteries or DC system never earth the Maximizer via the Earth Stake 6 2 CONNECTIONS Ensure that the Maximizer is switched OFF Use appropriately rated wire to connect PV input and battery bank output Polarity is i
19. ocococcconiccccocccoccnnnnnccnnnnnncnos 18 zlhggUri ce em PLE EE 18 Warranty InformatiON cmccocccoccnncnnnononancnnnancnnnrnnenacanoranrnnenanrnnnrnnnnrnnnnannnnanananas 19 2 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 1 OVERVIEW The AERL Coolmax Maximizer is a high efficiency buck only common positive peak power point tracker It employs a tracking strategy which has been proven to be highly robust immune to local extrema and results in power losses of less than 0 5 over the whole operating temperature range of a PV Array The versatility of the Coolmax Maximizer makes it an ideal choice for battery charging pumping DC motors and other solar powered applications The Maximizer range can also be used for Micro Turbine uTurbine applications including hydro and wind using a fixed turbine voltage set point to approximate the peak power voltage Additional features include High 98 99 operating efficiency Smart multi stage battery charging profile Support for active temperature compensation Compatible with all types of solar cells and battery arrays Onboard meter module for performance monitoring Passive cooling no moving parts results in highly reliable operation to 50 C Rugged protective enclosure with easy access door optional Support for low battery alarm or automatic low batte
20. odule toggle HV only 4 LCD meter Displays input voltage output voltage output current battery module current 5 Battery 100 Adjusts battery 100 float level Float adjustment trimpot 6 Battery Used for setting the nominal battery pack voltage Can be nominal used for speed control in pump motor applications voltage dials 7 Metering mode Choose between metering input voltage output voltage switch output current battery current 8 Piano dipswitch 1 Set up the Maximizer for sealed batteries different types of solar arrays 2 Turn Temperature Compensation on or off 3 Control whether the Maximizer is On by default or Off by default for remote control 9 Low battery Provides normally closed and normally open outputs which alarm are activated when low battery LED comes on This can be used for a remote alarm system or for genset control to charge the batteries Genset control 10 Temp comp Attach PTC thermistor to battery pack with wires into the sensor header header 11 Remote control Terminals of header can be linked for remotely controlling the header Maximizer Can be used as input from a sensor such as float switch in pumping applications 12 Battery fuse Protection against reverse connection of the batteries amp overcurrent situations 13 PV input Input from solar array terminal 14 Battery pump Output to batteries pump motor DC motor output terminal 5 of 20 USER S MANUAL COOLMAX MA
21. raphs will explain the load dump regulation technique and how to arrive at the value for the load dump regulation power resistor The Micro Turbine Maximizers use a very different Battery Regulation method than the PV Maximizers which simply unload the PV panels to limit the power flow to the battery bank once it reaches the 108 of Float Equalise Level and subsequently drops to the 10096 FLOAT FULL battery voltage level The DUMP LOAD method ensures that the Turbine remains always fully loaded and does not run away to high open circuit voltages that may damage the Turbine and or Maximizer once the battery bank is FULL Instead of the 10896 equalise level the Float Trimpot F is set to the top or final battery equalise level at which point the DUMP LOAD is switched in and cycles the battery bank down approximately 1296 in terminal voltage and is then switched out again This BATTERY FULL cycling automatically repeats itself as long as the Turbine is outputing more power than is required to keep the battery at the FULL Voltage pre set via the 100 Float Trimpot F EXAMPLE With a PV System charging a 48V Battery Bank where F is typically set to 56 5V 2 35V cell giving a 10896 battery equalise voltage of 60 4V On a Turbine System F is typically set to 59 0V 2 46V cell and cycles between this voltage and 52 0V 2 16V cell while in the cyclic DUMP LOAD BATTERY REGULATION MODE The Turbine Load Dump Resistor must be selected
22. re closing the circuit breakers and making the final connection to the Maximizer CIRCUIT BREAKERS ALWAYS FIT DC RATED INPUT AND OUTPUT PROTECTION CIRCUIT BREAKERS DO NOT USE FUSES Always select at least 6kA rated breakers as these have a better DC arc quenching capability than the only slightly less expensive and more common 4kA breakers If available 8kA or 10kA breakers are the very best choice for DC systems AERL recommends the use of Siemans or similar brand 6kA MCBs as an inexpensive breaking solution Example Siemans Part No 5SJ62206KS Refer to figure 4 1 on the following page to determine the appropriate breaker types and wiring configuration for LV MV HV and XHV Maximizers For XXHV units a high voltage DC breaker will be needed 6 of 20 HV MAXIMIZERS PV Array Coolmax Maximizer HV Battery Bank IN OUT ae See sb MV MAXIMIZERS PV Array Coolmax Maximizer MV Battery Bank of tor No ial oa I Paws PV Array Coolmax Maximizer XHV Battery Bank IN OUT NS P up a ra Siemans 6kA 20A Triple Pole MCB Figure 4 1 Recommended breaking configuration for LV MV HV and XHV Maximizers USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs 5 2 AERO1 0
23. ry switch off circuit Note For convenience this user s manual is oriented towards solar Maximizers being used to supply a battery pack For those supplying a DC pump or using the uTurbine version of the Maximizer the majority of the information is still relevant and it is still recommended to become familiar with the contents of the manual Section 9 details the critical information specific to operating the Maximizer with a DC pump or using the uTurbine version of the Maximizer 3 of 20 aerl Australian Energy Research Laboratories Pty Ltd 2 MAXIMIZER LAYOUT aer MAXIMIZER FOR THE PERFECT MATCH PV WIND amp MICRO HYDRO 3E336755 GC 2 94V 0 low ooo BATTERY IS FUSED evse nasao ALWAYS MOUNT ON A VERTICAL SURFACE ec oe O Cy ooo o s USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 24 May 2010 DANGER HIGH DC VOLTAGES m he JEMP CON 4 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 24 May 2010 aerl Australian Energy Research Laboratories Pty Ltd Position Name Function 1 LED status Low battery light activates at 10 5V 12V battery voltage indicators inaicato 100 full light activates when batteries have finished auto equalize 2 On Off switch Switches Maximizer on off Meter range Choose between high and low range output for meter m
24. s not required simply always press down the 2 Piano Dip Switch TEMP COMP OFF to take it out of circuit This also drops the Float and Auto Equalise Voltage Levels by approximately 196 LOW BATTERY DETECTION AND RELAY ALARM The low battery light will become lit at a voltage level of approximately 1 9V Lead acid cell A low battery isolated alarm relay changes state when the battery light is on The isolated contacts are accessible at screw terminals marked LOW BATT 6 7 and 8 on the bottom right corner of the board The relay contacts are rated at 1Amp 30V 30W with 1000V isolation The relay remains SET until the battery is once again charged and FULL a full 10896 charge equalise cycle is complete This means that the relay can be used for generator control REMOTE CONTROL The remote control header is a 2 way angled terminal block marked LINK ON OFF on the Coolmax PCB The terminals can be linked to either switch the Maximizer on or off There are two options for remote control Link for ON off by default Link for OFF on by default These options are selectable on the piano dipswitch using the DEFLT ON and DEFLT OFF buttons If DEFLT ON is selected the Maximizer will be on by default when the on off switch is switched on Linking the remote control outputs will turn the Maximizer off If DEFLT OFF is selected the Maximizer will be off by default even when the on off switch is switched on Linking
25. t in LCD Multimeter to set up this MOTOR VOLTAGE and then set to MOTOR AMPS to check the MOTOR CURRENT Never exceed the motor name plate current and Maximizer output current rating for pumping and always fit an output circuit breaker to protect the DC Pump motor from overload MICRO TURBINE MAXIMIZERS Overview The uTurbine series of Maximizers takes in rectified output of a turbine driven by hydro or wind power The uTurbine Maximizers cannot process AC power an appropriately rated diode rectifier must be used If required the uTurbine Maximizers implement overspeed protection for the turbine by switching in a load dump resistor or other load when the battery is too full to accept charge This load will need to be designed by the system installer and must be rated to dissipate the full power rating of the turbine The uTurbine Maximizers can and should be set to operate the turbine at a fixed voltage set point This allows the user to approximately determine a Maximum Power Point for the turbine for the typical wind speed water speed conditions that the turbine experiences 16 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 9 2 2 Selecting the Load Dump Regulation Power Resistor The load dump regulation power resistor needs to be connected to terminals marked DC Load on the Micro Turbine Maximizer The following parag
26. to match or exceed the expected Peak Turbine Output Power Use the simple formula V divided by Turbine Peak Power Load Dump Resistance where V is the Final FULL Battery Charge Voltage selected by the Battery 10096 Float Trimpot F For a 48V nominal Battery Bank with Viu 59V V 2 3481 For a Peak Turbine Power of say 1000W for example Load Dump Resistance 3 5 ohms For a Peak Turbine Power of 500W Load Dump Resistance 7 ohms Slightly lower than calculated resistance values can be used but not higher values as they will not fully load the Battery at peak Turbine power output Set the Built in Digital Multi Meter to read BATT AMPS to check that the load dump resistor current is a small negative value battery slightly loaded and discharging as expected so as to ensure correct cyclic battery regulation Confirm the cyclic regulation 17 of 20 USER S MANUAL COOLMAX MAXIMIZER Australian Energy Research Labs AERO1 003 ver 3 Australian Energy 24 May 2010 Research Laboratories Pty Ltd 9 2 3 Low Battery Circuitry on u Turbine Units 9 2 4 10 10 1 On Micro Turbine Units fitted with the Load Dump Option the Low Battery Circuitry is actually re calibrated to the voltage values listed above and used to switch the Load Dump power MOSFETs On amp OFF This means the isolated Low Battery STATUS Relay terminals 7 8 amp 9 can now be used to either monitor the status of the battery load dump resistor
Download Pdf Manuals
Related Search
Related Contents
Operation and Service Manual for HERMetic UTImeter Gtex 取扱説明書 Magellan 471 El Camino Real Santa Clara, CA. 95050 Ford 2007 Escape Automobile User Manual Accessing Documents in WebIntelligence InfoView XI 3.1 AlvariCRAFT for BreezeMAX TDD User Manual SOCIO 500 - Tecnomotor Manuel d`utilisation NASCAR Racing Version 1.5 Operation & Service Manual 001-104 Ducato MY FRA - Campingcar Copyright © All rights reserved.