Home

USER MANUAL

image

Contents

1. gt o WAMI INDUS TRIES SWAMP MS8 MK2 USER MANUAL Featuring genuine Neutrik NC3FAAH connectors MIC LINE SPLITTER SX XLR IN 16X XLR OUT Taking care of your MS8 MK2 Use the SWAMP MS8 MK2 to split eight balanced low impedance microphone signals into sixteen balanced low impedance microphone signals eight pairs Each channel of the MS8 MK2 provides one direct output and one transformer isolated output from a single microphone Applications include sending the direct outputs to the main or FOH Front Of House mixer and the second outputs being outputs being sent to a monitor or recording mixer The direct outputs pass phantom power from the main mixer to the microphone for use with condenser microphones SPECIFICATIONS NOTE All measurements made from TRANSFORMER ISOLATED MICROPHONE OUTPUT with PAD SWITCH out off and 150 Ohm balanced source feeding MI CROPHONE INPUT and 1K Ohm load connected to e FREQUENCY RESPONSE e TOTAL HARMONIC DISTORTION The SWAMP MS8 MK2 includes a ground lift switch on each isolated output to reduce noise due to ground loops between connected equipment For versatility the MS8 MK2 also features an attenuator pad switch on each input that can be used to connect pre amplified signals to the two microphone level outputs on each channel Typically pre amplified signals would originate from instrument preamplifiers mixers keyboards etc Rack mounting ears are reversible for Flexibil
2. smoke machines Handling To prevent damage to the controls and cosmetics avoid rough handling and excessive vibration Protect the controls from damage during transit Use adequate padding if you need to ship the unit To avoid injury to yourself or damage to the equipment take care when lifting moving or carrying the unit Servicing Refer servicing to qualified technical personnel only
3. ity in system cabling The 19 1U black all steel case and its all passive design allow the SWAMP MS8 MK2 to provide years of trouble free service TRANSFORMER ISOLATED MICROPHONE OUTPUT to simulate a typical real world microphone and mic preamplifier 20 Hz to 20K Hz 0 25 dB 15 dBu 3 dB at approximately 165K Hz Less than 0 26 from 20 Hz to 20K Hz at 15 dBu input Less than 0 1 from 45 Hz to 20K Hz at 15 dBu input 0 002 Typical at 1K Hz 15 dBu input e PHASE RESPONSE e INPUT IMPEDANCE 150 Ohms Less than 10 degrees at 20K Hz ref 1K Hz Greater than 1 1K Ohms at 1K Hz Typical driving source impedance is USAGE Connect low impedance dynamic or condenser microphone to any MICROPHONE INPUT on the SWAMP MS8 Mkz2 Alternatively connect line level signal to any MICROPHONE INPUT and engage corresponding front panel INPUT PAD switch Conned corresponding DIRECT MICROPHONE OUTPUT to mic input on main mixer switch phantom power on at mixer if desired Connect corresponding TRANSFORMER ISOLATED MICROPHONE OUTPUT to mic input on secondary mixer or recording system Set GROUND switches to LFT or GND Use whichever setting provides lowest noise performance NOTE The chassis ground connects to the Channel One input ground only in order to reduce the possibility of channel crosstalk through chassis ground To provide the noise shielding benefit of the chassis enclosure when the 58 is not mounted in a gr
4. ounded rock system be sure to use the Channel One input when using fewer than eight channel input connections IMPORTANT SAFETY INSTRUCTION READ FIRST A b This symbol wherever it appears alerts you to important operating and maintenance instructions in the accompanying literature Please read the manual Read instructions Retain these safety and operating instructions for future reference Heed all warnings printed here and on the equipment Follow the operating instructions printed in this user guide Do not open There are no user serviceable parts inside Refer any service work to qualified technical personnel only Moisture To reduce the risk of fire or electrical shock do not expose the unit to rain moisture or use in damp or wet conditions Do not place container of liquid on it which may spill into any openings Environment e OUTPUT IMPEDANCE Less than 255 Ohms at 1K Hz Typical output load impedance is 1K Ohms e COMMON MODE REJECTION RATIO Greater than 105 dB 60 Hz Greater than 80 dB 3K Hz e VOLTAGE INSERTION LOSS Approximately 2 dB at 1K Hz e MAXIMUM INPUT LEVEL FOR 1 THD 1 4 dBu at 20 Hz 3 5 dBu at 30 Hz 9 4 dBu at 50 Hz e DIMENSIONS 1 75 H x 19 W x 3 75 D 44 5mm x 482 6mm x 95mm e WEIGHT 3 75 Ibs 1 7 ko Ref O dBu 0 775 VRMS Protect from excessive dirt dust heat and vibration when operating and storing Avoid tobacco ash drink spillage and smoke especially that associated with

Download Pdf Manuals

image

Related Search

Related Contents

BlomURBEX™ ArcMap Plug  Knoll GSZ67 User's Manual  Unidad de trans- misión  ダウンロード(PDF 0.37 MB)  Engineered Carbon Dioxide (CO2) Fire Suppression Systems  Operating Instructions  113565 62 ind 04.QXD:Notice_Tirfor_2004_G2  Cultures légumières  desenvolvimento sustentável em áreas urbanas de génese  Whirlpool GD8200Y User's Manual  

Copyright © All rights reserved.
Failed to retrieve file