Home
RefSet Tablet User Manual Contents
Contents
1. Shift then Quit to exit refline and return to the main menu screen Refline Refline 1 2 Pt Increment Pt Increment 2 Auto Interval 1 000 Refline Pt Increment 4 Auto Interval 1 000 Auto Offset 0 000 Auto Height 1 500 At End Of Line Continue Slope Line 4 797 At End Of Line Continue AHoriz Line 4 756 Horiz Line 4 756 Ht 0 000 Ht 0 000 Ht 0 000 Auto Refline Screen Auto Hole Screen Auto Grade Screen Auto Grade Line Setout e Set up the refline start and end points using the design string points or use the Meas function to measure the points and then manually enter a grade in the Refline Selection screen to extend an existing grade line if no design is to be used eg ore drives e Auto then tap AGrade to turn on auto grade and go to the auto grade screen e Check the Auto Height setting and set to the refline height offset that is to be set out eg 1 500 for a grade line 1 5m above the design e Point the TPS at the wall at the approximate position to start the setout and then tap on Dist to start measuring and start the auto grade setout e The TPS will then move and setout the Height value that has been set in the Auto Height setting eg 1 500 to within the AGrade Height Accuracy set in the refline configuration eg 0 025m near the start position e When the refline has been setout the TPS will beep and flash the guide light to indicate that the auto
2. AUTO RING SETOUT BY REF 10 AUTO RING SETOUT BY RING SPACING ccccccccccccessssssssesseeseessesesseeeseesees 11 AUTO RING SETOUT BY REF LINES 12 5 REFLINE CONFIGURATION SETTINGE cccssssccsssssccsssssccesssccsessseeces 13 6 SE VOUW wiccecccissssessssscsussecsdsvssvsssensccessneessssevsesesctesssoscecsssessesssteaces lt uatadcssassosesstvesss 14 AUTO SETOUT E 14 7 SETOUT CONFIGURATION SETTINGS RefSet Program Installation and Setup GeoCom License Key Entry on TPS e From the TPS start screen e Select Tools then Licence Keys e Select Manual Entry of Key for Method e Arrow Down to Key and then enter the licence key e Press F1 CONT TPS Bluetooth Setup e From the TPS start screen e Select Config then Interfaces then GeoCOM Mode e Press F3 EDIT to edit the interface setup e Select Yes for the Use Interface setting e Arrow down to Port and select Port 3 BT e Press 5 DEVCE e Arrow down to RS232 GeoCOM e Press EDIT to edit the communication settings e Press F5 DEFLT to select the default settings which should be Baud Rate 19200 Parity None Data Bits Stop Bit 1 e Press F1 STORE to save the settings e Press F1 CONT then F1 CONT then F1 CONT to finish setup PC Bluetooth Setup TufTab a7230 with Toshiba Bluetooth Manager e Make sure the TPS is turned on e On the PC
3. Auto Accuracy set in the refline configuration eg 0 025m When the hole has been setout the TPS will beep and flash the guide light to indicate that the auto setout point has been reached The program will then change to the next refline by incrementing the refline start and end points using the Pt Increment value as when the NextLine button is tapped and will then setout the collar position of that hole Note The Pt Increment value is set to 2 when the AHole function is started To stop auto hole setout tap the Stop button To turn auto hole setout off tap the AHole button 10 Refline Pt Increment Rig Laser O S 1 000 Refline Refline Pt Increment Pt Increment Rig Laser O S Rig Laser 5 Ring Spacing Ring Number Ring RefPt 2 AHeight 1 970 Height 1 970 Ht 0 000 Ht 0 000 Ht 0 000 a ei nL ee ie Let ARing by Ref Points Screen ARing by Ring Spacing Screen ARing by Ref Lines Screen Height 1 970 Auto Ring Setout e The auto ring setout method can be set in the Refline Configuration and the setup of the data points for each method can be seen in the examples below e The Ref Points method needs a point for the start and end of the refline and reference points somewhere on each ring these points do not have to be on the centreline e The Ring Spacing method only requires a point for the start and end points of the refline however the start p
4. refline by incrementing the refline start and end points using the Pt Increment value as when the NextLine button is tapped and will then setout the Laser Line position of the next ring Note The Pt Increment value is automatically set to 2 when the ARing by ref lines function is started To stop auto ring setout tap the Stop button To turn auto ring setout off tap the ARing button 13 5 Refline Configuration Settings EDM Program Start Measure Auto Accuracy ARing Height Acc AGrade Height Acc Auto Wait secs Auto Interval ARef S O Offset AGrade S O Height Auto End Of Line Auto Ring Method Rig Laser O S Ring Spacing The EDM program to use in refline RL TRK Reflectorless tracking RL STD _ Reflectorless standard Start distance measuring when refline starts Sets the accuracy at which points are setout in auto modes eg if set to 0 025 the TPS will get the points to within 25mm before moving to the next point Sets the accuracy at which the Height is setout in the ARing mode eg if set to 0 200 the TPS will setout the laser lines to within 200mm of the Height of the first laser line setout Sets the accuracy at which the Height is setout in the AGrade mode Sets the time the TPS will stop on an auto setout point eg if set to 5 the TPS will wait 5 seconds after it sets out a point before it moves on to the next point Sets the interval between setout points in the ARef and AGra
5. tap on Start Bluetooth Bluetooth Settings e Tap on the New Connection button or tap on Bluetooth Add New Connection e Select Custom Mode and tap on Next e When the TPS has been discovered it will appear in the list as lt Instrument Type Serial No eg lt TCRA1201 R1000 260099 e Select the TPS icon in the list and then tap on Next e Enter the Bluetooth Passkey PIN as 0000 then tap on OK e Select Serial Port at Please choose the service to use and tap on Next Check that the COM port is between COM1 to COM8 if not unselect Use default port and then select a COM port between COM1 to COM8 Make sure Auto Connect is selected and tap on Next Tap Next to finish COM port setup Leave the Connection Name as is and tap on Next and then Finish Select the TPS icon in the Bluetooth Settings and then tap on Bluetooth Connect to connect to the TPS this should only have to be done once if Auto Connect was selected in the step above PC with Windows7 Bluetooth Manager Make sure the TPS is turned on On the PC click on Start Control Panel Hardware and Sound Devices and Printers Click on Add a device When the TPS has been discovered it will appear in the list as lt Instrument Type Serial No eg lt TCRA1201 R1000 260099 Select the TPS icon in the list and then click on Next Enter the Pairing code as 0000 then click on Next and then Close After the device has been successfully installed s
6. ve values move the laser lines forward along the refline ve values move the laser lines back along the refline in the example above it would be set to a negative value Check the Ring Spacing setting on the auto ring setout screen and set to the distance between the rings On the auto ring setout screen select the Ring Number of the ring to setout The numbering of the rings starts from the start point number and increases towards the end point for the number of rings between the start and end point in the example above the ring numbers would start at 1 and go to 5 Point the TPS at the wall at the approximate position of the ring Tap on Dist to start measuring and to start the auto ring setout The TPS will then move and setout the ring laser line position by getting the Laser Line value on the auto ring setout screen to zero to within the Auto Accuracy set in the refline configuration eg 0 025m it will also setout the same Height value as the start point to within the ARing Height Accuracy set in the refline configuration eg 0 2m 12 When the ring laser line has been setout the TPS will beep and flash the guide light to indicate that the auto setout point has been reached The program will then increment the Ring Number value by the Pt Increment value and then setout the laser line of the next ring in the example above if the Pt Increment is set to 1 the Ring Number will increment to 2 and setout the laser line of ring 2
7. PS will then move and setout the ring laser line position by getting the Laser Line value on the auto ring setout screen to zero to within the Auto Accuracy set in the refline configuration eg 0 025m it will also setout the same Height value as the start point to within the ARing Height Accuracy set in the refline configuration eg 0 2m When the ring laser line has been setout the TPS will beep and flash the guide light to indicate that the auto setout point has been reached The program will then increment the Ring RefPt value by the Pt Increment value and then setout the laser line of the next ring in the example above if the Pt Increment is set to 1 the Ring RefPt will increment to 3 and setout the laser line of ring 2 the Pr Increment can be set to ve values to decrement the Ring RefPt values Note The Pt Increment value is automatically set to 1 when the ARing by ref points function is started To stop auto ring setout tap the Stop button To turn auto ring setout off tap the ARing button Auto Ring Setout by Ring Spacing Set up the refline with the start and end points in the example above the start point would be 1 and the end point would be 2 the start point needs to be located on the first ring and if possible needs to have the same number as the first ring Tap Auto then tap ARing to turn on auto ring setout and go to the auto ring screen Check the Rig Laser Offset setting on the auto ring setout screen
8. RefSet Tablet Automatic Reference Line and Setout Program For User Manual Version 1 3 Leica 1200 TPS Justin Gardner 2011 www refset com au Contents 1 REFSET PROGRAM INSTALLATION AND SETUD cccccccsssssssscccseeees 2 GEOCOM LICENSE KEY ENTRY ON TPS 0 00 ccc cccccecccccccccccecssesscesecesessssssesseesens 2 TPS BLUETOOTH SETUP 2 PC BLUETOOTH SETUP 2 TufTab a7230 with Toshiba Bluetooth 2 PC with Windows7 Bluetooth Manager 0 0 0 0cc cece eee eeeecscee ce teceesaeeesseeseetaseeeseeeeeeeaes PC with WindowsXP Bluetooth REFSET TABLET INSTALLATION ON TABLET PC REFSET TABLET KEY FILE INSTALLATION ON TABLET 4 2 REFSET PROGRAM 5 3 REFSET PROGRAM OPERATION sssccssssssccsssscccsssscccesssccscssseccscsssceeesss 6 PROGRAM STARTUP 6 REMOTE CONTROL OPERATION 00 cccccccccssssscscccsesssssscesecsseesesssessesveeesssneesees 6 4 REFLINE 7 AUTO GRADE LINE 8 AUTO REELINE SETOUT 9 AUTO HOLE SETOUT 9 AUTO RING SETOUT oe cc ices svesscscscccdsseouebedecscacessssentecedosesseestiesededecesdencnendedexboesee 10
9. Tablet Installation on Tablet PC Extract the Install_RefSet_Tablet exe file from the zip file into any folder on the Tablet PC In Windows Explorer on the Tablet PC double tap on the Install_RefSet_Tablet exe file RefSet Tablet will then start to install Tap on Yes at the User Account Control screen to allow the program to install Follow the instructions to install the program to the hard disk An icon to start RefSet Tablet is placed on the desktop and in the Start menu RefSet Tablet Key File Installation on Tablet PC Copy the RefSet_ serial number key file to the Program Files RefSet RefSet Tablet folder on the Tablet PC Repeat the procedure for other key files for each TPS if multiple instruments will be used with this Tablet PC 2 RefSet Program Configuration e Start RefSet Tablet e Tap or select Program Configuration e COM Port Set to the same as that set in the Tablet PC in the PC Bluetooth Setup eg COM7 e Comms Settings Baud Rate Parity Data Bits Stop Bit Set to the same as that set in the instrument in the TPS Bluetooth Setup eg 19200 None 8 1 e Data File Type Set to the type of data point file to use in RefSet STR Surpac string file GSI Leica gsi data file Data Folder Set to the path name of the folder of data point files This can either be on the Tablet PC or on a memory card The Data Folder must have two subfolders Data Surpac string files folder GSI Leica gsi data files folder This is the
10. de modes The default Auto Offset value to setout in auto refline mode The default Auto Height value to setout in auto grade mode Sets the behaviour of the auto setout mode when the end of the refline is reached in the ARef and AGrade modes Stop Stops auto setout at the end of the refline Continue Continues auto setout past the end of the refline Next Line Increments to the next refline at the end of the current refline The ring setout method in auto ring mode The default Rig Laser O S value in auto ring mode The default Ring Spacing value in auto ring mode 14 refset_test Point ID Point ID Pt Increment Pt Increment 4 AHZ 0 00 02 AHDist 3 439 Away 2 063 Cut Height 2 063 Cut 101 634 95 205 98 400 0 000 Ht 0 000 Setout Selection Screen Polar Setout Screen Ortho Setout with Auto on 6 Setout With RefSet Tablet connected to the TPS Tap Setout on the main menu screen The Setout Selection screen will then be shown Select the Data Job to use from the list Select the Point ID from the list OR To enter the point coordinates from the keyboard tap Input and then enter the coordinates for the point then tap Cont the new point will then be stored in the data file To start the point setout tap Cont The TPS will then turn towards the setout point if Auto Posit is set to Y in the setout config and will start measuring if Start Measure is set t
11. e TPS Wait until the TPS has finished its startup sequence Tap Retry on the Check Connection screen in RefSet Tablet The program should then reconnect to the TPS Continue with the program operation Note During operation the TPS is controlled by RefSet Tablet any settings changed on the TPS by the operator eg changing the EDM Mode changing the Reflector Ht will be overridden by the settings in RefSet Tablet to change these settings make the changes in RefSet Tablet At the end of the survey tap Quit to disconnect from the TPS and exit RefSet Tablet Remote Control Operation During both the Refline and Setout programs the TPS may be turned remotely to point it at a specific position In the Refline or Setout program tap Shift then Remote to enter the remote mode Tap the direction buttons to move the TPS in that direction each tap of the button will increase the speed of the TPS movement tap the opposite direction Left Right Up Down Back Stop button to decrease the speed of the TPS Tap Stop to stop the TPS at the required position Tap Back to return to the Refline or Setout program 4 Refline e With RefSet Tablet connected to the TPS e or select Refline on the start menu screen e Refline Selection screen will then be shown e Select the Data Job to use from the list e Select the Start Point and End Point of the refline from the lists OR Select either t
12. elect the TPS icon in the list of devices and then right click and select Properties Select the Hardware tab Check that the COM port is between COM1 if not click on Properties and then click on Change Settings Select the Port Settings tab and then click on Advanced Select COM Port Number between COM1 to COM8 Click on OK and then OK and then OK PC with WindowsXP Bluetooth Manager Make sure the TPS is turned on On the PC click on Start Control Panel Double click on Bluetooth Devices Under the Devices tab click on Add Select My device is set up and ready to be found and then click on Next When the TPS has been discovered it will appear in the list as lt Instrument Type Serial No eg lt TCRA1201 R1000 260099 Select the TPS icon in the list and then click on Next Select Use the passkey found in the documentation and enter the passkey as 0000 then click on Next Check that the Outgoing COM port number is between COM1 to 8 and click on Finish and then OK If the port is not between to 8 in the Control Panel double click on System then select the Hardware tab and click on Device Manager Double click on the Ports COM amp LPT to display COM ports Double click on the current COM Port assigned to the TPS Select the Port Settings tab and then click on Advanced Select COM Port Number between COM8 Click on OK and then OK and then close the Device Manager RefSet
13. he Start Point or the End Point list box To enter the point coordinates from the keyboard tap Input and then enter the new Point ID and coordinates for the selected point then tap Cont the new point will then be stored in the data file To measure a point tap Meas then at the Measure Point screen enter the new Point ID and then point the TPS to the point to measure and make sure a distance has been measured then tap Cont the new point will then be stored in the data file e To manually enter a grade for the refline select Y for Enter Grade then enter the grade to use eg 50 for up at 1 in 50 or 50 for down at 1 in 50 The refline will then go from the start point elevation towards the end point at the entered grade e display the refline details and the start end point coordinates tap on Info e To start the refline measurement tap Cont Offset Horiz Line Slope Line Height Height Refline Selection Screen Main Refline Screen Showing Start Point selected for Input or Meas e Tap NewLine to return to the Refline Selection screen to enter new refline points e Tap NextLine to go to the next refline by incrementing the refline start and end points by the Pt Increment value eg if Pt Increment is then refline will change from 1 2 to 2 3 if Pt Increment is 2 then refline will change from 1 2 to 3 4 if Pt Increment is 1 then refline will change from 2 3 to 1 2 e
14. n When the refline has been setout the TPS will beep and flash the guide light to indicate that the auto setout point has been reached The TPS will then move along the refline at the set Auto Interval value eg 1 0m intervals and setout each interval At the end point of the refline the auto setout function will respond according to the setting in End Of Line on the auto refline screen If set to Continue the auto setout will continue past the refline end point If set to Stop the auto setout will stop near the refline end point If set to Next Line the auto setout will stop near the refline end point then will change to the next refline by incrementing the refline start and end points using the Pt Increment value as when the NextLine button is tapped auto refline setout will then continue using the new refline and setout the Auto Offset value To stop auto refline setout tap the Stop button To turn auto refline setout off tap the ARef button Auto Hole Setout Set up the refline start and end points to be the collar and toe points of the drill hole Tap Auto then tap AHole to turn on auto hole setout and go to the auto hole screen Point the TPS at the wall or backs at the approximate position of the hole Tap on Dist to start measuring and to start the auto hole setout The TPS will then move and setout the hole collar position by getting the Offset and Ht values on the auto hole setout screen to zero within the
15. o Y in the setout config Tap NewPt to return to the Setout Selection screen to enter a new setout point Tap NextPt to go to the next point by incrementing Point ID by the Pt Increment value Tap Shift then Pos2D or Pos3D or PosPP3D to position the TPS telescope back to the setout point the positioning method is set by the Posit Mode setting in the setout configuration and has three modes Tap Shift then Disp to toggle the setout mode between Polar and Ortho Tap Shift then Quit to exit setout and return to the main menu screen Auto Setout Tap Auto to turn on auto setout mode If distance measuring is not active tap on Dist to start measuring and start the auto setout The TPS will then setout the point ie get the HDist to zero to within the Auto Accuracy set in the setout configuration eg 0 025m When the point has been setout the TPS will beep and flash the guide light to indicate that the auto setout point has been reached 15 e The program will then change to the next setout point by incrementing the Point ID using the Pt Increment value as when the NxtPt button is tapped and will then setout the position of that point e stop auto setout tap the Stop button e To turn auto setout off tap the Auto button 7 Setout Configuration Settings e Default Mode The default setout display mode Polar Display shows 5 HDist and Height Ortho Display shows Length Cross and Height e EDM Program The EDM p
16. oint needs to be on the first ring and the ring spacing needs to be consistent for the entire ring markup The point number of the start point should also match the ring number of the first ring if possible e The Ref Lines method needs two points for each ring line and needs to follow a consistent numbering system eg all the start points to the right of the refline and all the end points to the left of the refline Ring 5 Ring 5 10 Rings 9 Ring 4 Lines Ring 4 8 Ring4 7 Ring 3 Ring 3 6 Ring 3 5 rs Ring Spacing Ring 2 Ring 2 4 Ring 2 3 Ring 1 Rig L Ring 1 2 Ring 1 1 ig Laser 1 ARing by Ref Points ARing by Ring Spacing ARing by Ref Lines Auto Ring Setout by Ref Points e Set up the refline with the start and end points in the example above the start point would be 1 and the end point would be 7 e Tap Auto then tap ARing to turn on auto ring setout and go to the auto ring screen 11 Check the Rig Laser Offset setting on the auto ring setout screen ve values move the laser lines forward along the refline ve values move the laser lines back along the refline in the example above it would be set to a negative value On the auto ring setout screen select the Ring RefPt of the ring to setout in the example above set it to point 2 to start setting out the rings at ring 1 Point the TPS at the wall at the approximate position of the ring Tap on Dist to start measuring and to start the auto ring setout The T
17. rogram to use in setout RL TRK Reflectorless tracking RL STD _ Reflectorless standard e Start Measure Start distance measuring when setout starts e Mode Method of positioning the TPS telescope 2D Setout point using horizontal coords only 3D Setout point using horizontal and vertical coords PP3D Setout point using horizontal coords and vertical coord of previous point Auto Position the TPS telescope when setout starts Auto Accuracy Sets the accuracy at which points are setout in auto modes eg if set to 0 025 the TPS will get the points to within 25mm before moving to the next point Auto Wait secs Sets the time the TPS will stop on an auto setout point eg if set to 5 the TPS will wait 5 seconds after it sets out a point before it moves on to the next point
18. same folder structure as on the Leica CF data cards used in the TPS Log Setout Data Set to Y to save the automatic setout points to a log file The points setout in all automatic modes will be saved to this file which will be saved in a folder named Log under the Data Folder e Log File Type Set to the type of log file to save the automatic setout point data to STR Surpac string file CSV Comma separated text file 3 RefSet Program Operation Program Startup Turn on the TPS Setup the TPS using the normal station setup procedures eg Resection etc When station setup is complete TPS can be left in any screen display Turn on the Tablet PC Start RefSet Tablet on the Tablet PC Tap or select Connect to TPS When the connection is made the menu will change to Disconnect from TPS and the TPS will beep once and display a connected icon next to the Bluetooth icon If no connection is made Unable to Connect to TPS will be displayed if this occurs Check TPS is still on if not restart TPS and try to connect again If TPS is still on then select Quit in RefSet Tablet and then restart RefSet Tablet and try to connect again If there is still no connection then select Quit in RefSet Tablet and then shut down and restart the PC and try to connect again If during operation the TPS switches off eg flat battery No Connection to TPS will be displayed in RefSet Tablet if this occurs Replace the battery on the TPS and turn th
19. setout point has been reached e The TPS will then move along the refline at the set Auto Interval value eg 1 0m intervals and setout each interval e At the end point of the refline the auto setout function will respond according to the setting in End Of Line on the auto grade screen If set to Continue the auto setout will continue past the ref line end point If set to Stop the auto setout will stop near the ref line end point If set to Next Line the auto setout will stop near the ref line end point then will change to the next refline by incrementing the refline start and end points using the Pt Increment value as when the NextLine button is tapped auto grade setout will then continue using the new refline and setout the Auto Height value e To stop auto grade setout tap the Stop button e To turn auto grade setout off tap the AGrade button Auto Refline Setout Tap Auto then tap ARef to turn on auto refline setout and go to the auto refline screen Check the Auto Offset setting and set to the refline offset that is to be set out eg 0 000 for the centreline Point the TPS at the wall or backs at the approximate position to start the setout and then tap on Dist to start measuring and start the auto refline setout The TPS will then move and setout the Offset value that has been set in the Auto Offset setting eg 0 000 to within the Auto Accuracy set in the refline configuration eg 0 025m near the start positio
20. the Pr Increment can be set to ve values to decrement the Ring Number values Note The Pt Increment value is automatically set to 1 when the ARing by ring spacing function is started To stop auto ring setout tap the Stop button To turn auto ring setout off tap the ARing button Auto Ring Setout by Ref Lines Set up the refline with the start and end points of the first ring in the example above the start point would be 1 and the end point would be 2 Tap Auto then tap ARing to turn on auto ring setout and go to the auto ring screen Check the Rig Laser Offset setting on the auto ring setout screen ve values move the laser lines to the right of the ring ve values move the laser lines to the left of the ring in the example above it would be set to a negative value Point the TPS at the wall at the approximate position of the ring Tap on Dist to start measuring and to start the auto ring setout The TPS will then move and setout the ring laser line position by getting the Laser Line value on the auto ring setout screen to zero to within the Auto Accuracy set in the refline configuration eg 0 025m it will also setout the same Height value as the start point to within the ARing Height Accuracy set in the refline configuration eg 0 2m When the ring laser line has been setout the TPS will beep and flash the guide light to indicate that the auto setout point has been reached The program will then change to the next
Download Pdf Manuals
Related Search
Related Contents
8-Port 10/100Mbps 802.3af / 802.3at PoE + 1 Ensemble de caches Pitot et statiques - Aéro User Interfaces for Applications on a Wrist Watch User Manual PDF マイナンバー安心セットカタログ - 日本電気 Philips Layered protective case DLM4348 48-981型 取扱説明書 保証書付 樹脂管用温水プラグ〔流量可変型〕 Gazette n°3 - Mathématiques académie de Rouen the user manual - The Race for the White House User Manual - Infosystem Technology Corporation, Ltd. Copyright © All rights reserved.